Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST TENDERER | |
| 2 | L2₹19.5 L+₹2.0 L (11.5%)Rejected-Finance BLDG NO XI 74 NEAR VALLARAM KULLANGARA TEMPLE KUNHIMANGALAM KOVVAPPURAM PO KANNUR DIST KERALA 670309 | KANNUR | KERALA | 670309 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹24.1 L+₹6.6 L (37.8%)Rejected-Finance 50A 7B 5C UMARPUR NIWA DHOOMANGANJ PRAYAGRAJ UP | PRAYAGRAJ | UTTAR PRADESH | 211011 | L3 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
14 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Aditya Gorhe
GE Utility Bathinda Mil stn
REPAIR / MAINTENANCE OF STPS AT DIFFERENT LOCATIONS AT NORTH CAMPUS UNDER GE (UTILITY) BATHINDA.
2022_MES_569266_1
8686/2022-23/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Garrison Engineer Utility Bathinda
class E cat a ii
9 documents required · 9 mandatory
₹500
Garrison Engineer Utility Bathinda
₹40,000
Yes
25 Jan 2023
15 Dec 2022
16 Jan 2023
15 Dec 2022
14 Jan 2023
30 Dec 2022
Amount
Dewatering/bailing out raw sewage and scraching the inner surface of the open sewage collection tank of diameter 3.6 mtr at a depth of upto 6 mtr with the help of wire brush, steel patti and emery paper and removing any silt, sludge, raw material of sewage from the well with the help of any T & P as required and throwing it away 100 mtr from the STP complete all as directed. ( Pocket -01 & Pocket -08)
Dewatering/bailing out raw sewage and scraching the inner surface of the open sewage collection tank of diameter 3.8 mtr at a depth of upto 8 mtr with the help of wire brush, steel patti and emery paper and removing any silt, sludge, raw material of sewage from the well with the help of any T & P as required and throwing it away 100 mtr from the STP complete all as directed.(Pocket No:05)
Dewatering/bailing out raw sewage and scraching the inner surface of the open sewage collection tank of diameter 3.6mtr at a depth of upto 6 mtr with the help of wire brush, steel patti and emery paper and removing any silt, sludge, raw material of sewage from the well with the help of any T & P as required and throwing it away 100 mtr from the STP complete all as directed.(Pocket No:10)
Dewatering/bailing out raw sewage and scraching the inner surface of the open sewage collection tank of diameter 3.6mtr at a depth of upto 6 mtr with the help of wire brush, steel patti and emery paper and removing any silt, sludge, raw material of sewage from the well with the help of any T & P as required and throwing it away 100 mtr from the STP complete all as directed.(Pocket No:12)
Dewatering/bailing out raw sewage and scraching the inner surface of the open sewage collection tank of diameter 3.8mtr at a depth of upto 6 mtr with the help of wire brush, steel patti and emery paper and removing any silt, sludge, raw material of sewage from the well with the help of any T & P as required and throwing it away 100 mtr from the STP complete all as directed.(Jadunath STP)
Dewatering/bailing out raw sewage and scraching the inner surface of the open sewage collection tank of size 4.5mtr z 4.30 mtr x 7.50 mtr (depth), with the help of wire brush, steel patti and emery paper and removing any silt, sludge, raw material of sewage from the well with the help of any T & P as required and throwing it away 100 mtr from the STP. all as directed by Engineer-in-charge.(Ranjit/Govind Colony Sumpwell)
Dewatering/bailing out raw sewage and scraching the inner surface of the sewage collection tank of diameter 4.80mtr at a depth of upto 5 mtr with the help of wire brush, steel patti and emery paper and removing any silt, sludge, raw material of sewage from the well with the help of any T & P as required and throwing it away 100 mtr from the STP. all as directed by Engineer-in-charge.(Shivaji Enclave Sumpwell 1, 2 & 3)
Cleaning and removing sludge from walls /floor of one Nos Equilization tank & Treated water open tank of dia 5.5 mtr & 6.2 mtr with the help of wire brushes ,steel patti and emery paper and depositing where directed by Engineer - in - Charge at a distance 100 mtr away from outer wall of STP and white wash to walls complete all as directed.(Pocket No:10)
Cleaning and removing sludge from walls /floor of one Nos Equilization tank & Treated water open tank of dia 8.2 mtr & 4.4 mtr with the help of wire brushes ,steel patti and emery paper and depositing where directed by Engineer - in - Charge at a distance 100 mtr away from outer wall of STP and white wash to walls complete all as directed. (Pocket No:01 & 08)
Cleaning and removing sludge from walls /floor of one Nos Equilization tank & Treated water open tank of dia 5.5 mtr & 4.0 mtr with the help of wire brushes ,steel patti and emery paper and depositing where directed by Engineer - in - Charge at a distance 100 mtr away from outer wall of STP and white wash to walls complete all as directed. (Pocket No:012)
Cleaning and removing sludge from walls /floor of one No equalization tank of dia 8.20 meter and one No Treated water open tank of size 5.90 x 5 x 6.0 mtr with the help of wire brushes ,steel patti and emery paper and depositing where directed by Engineer - in - Charge at a distance 100 mtr away from outer wall of STP and white wash to walls complete all as directed.(Pocket No:05)
Cleaning and removing sludge from walls /floor of one Nos Treated water open tank of size 8.20 x 8.20x10mtr with the help of wire brushes ,steel patti and emery paper and depositing where directed by Engineer - in - Charge at a distance 100 mtr away from outer wall of STP and white wash to walls complete all as directed. (Jadunath STP)
Cleaning and removing sludge from walls /floor of one Nos Treated water open tank of size 10 x 10x 3.6mtr with the help of wire brushes, steel patti and emery paper and depositing where directed by Engineer - in - Charge at a distance 100 mtr away from outer wall of STP and white wash to walls complete all as specified and as directed by Engineer - in -Charge.( Ranjit/Govind STP)
Cleaning and removing sludge from walls /floor of one Nos Treated water open tank of size 6.4m x 4.4m x 4.4m with the help of wire brushes ,steel patti and emery paper and depositing where directed by Engineer - in - Charge at a distance 100 mtr away from outer wall of STP and white wash to walls complete all as specified and as directed by Engineer - in -Charge.(Jadunath STP)
Cleaning and removing sludge from walls /floor of one Nos Equilization tank of dimension 11mtr x 11mtr x 5mtr with the help of wire brushes, steel patti and emery paper and depositing where directed by Engineer-in-Charge at a distance 100 mtr away from outer wall of STP and white wash to walls complete all as specified and as directed by Engineer - in -Charge.(Ranjit/Govind Colony STP)
Cleaning and removing sludge from walls /floor of one Nos Equilization tank of dimension 7.40mtr x 5.30mtr x 4mtr with the help of wire brushes, steel patti and emery paper and depositing where directed by Engineer-in-Charge at a distance 100 mtr away from outer wall of STP and white wash to walls complete all as specified and as directed by Engineer - in -Charge.(Shivaji Enclave STP)
Cleaning,removing and bailing out stagnated sewage or sludge from walls/floor and any light particle with the help of wire brushes ,steel patti and emery paper from two Nos MBBR reactor inner surface of size 3.5 x 3.5 x 5.0 meter and taking out damaged and unbroken MBBR media without any damage and refilling it in each MBBR with old unbroken media cleaning of inner and outer surface of MS pipe placed in MBBR and removing any sludge particle from it to entire satisfaction of Engineer-in-Charge. (Pkt-01 & Pkt-08)
Cleanin,removing of sludge from walls/floor with the help of wire brushes ,steel patti and emery paper from two Nos MBBR reactor inner surface of size 2.8 x 2.8 x 5.0 meter and taking out damaged and unbroken MBBR media without any damage and refilling it in each MBBR with old unbroken media cleaning of inner and outer surface of MS pipe placed in MBBR and removing any sludge particle from it to entire satisfaction of Engineer-in-Charge.(Pkt-10)
Cleanin,removing of sludge from walls/floor with the help of wire brushes ,steel patti and emery paper from two Nos MBBR reactor of size 2.0 x 2.0 x4.30 meter and taking out damaged and unbroken MBBR media without any damage and refilling it in each MBBR with old unbroken media cleaning of inner and outer surface of MS pipe placed in MBBR and removing any sludge particle from it to entire satisfaction of Engineer-in-Charge.(Pkt-12)
Cleaning and removing of sludge from walls/floor of two Nos MBBR/FAB REACTOR of size 2.8 x 3.15 x 6.1 meter each with the help of wire brushes ,steel patti and emery paper and depositing where directed by Engineer - n - Charge at a distance 100 meter away from outer wall of STP including after cleaning painting to MS pipe two nos of size 200 mm dia , 6.1 m length each fixed in vertical position by using black bitumen paint and white wash to walls of MBBR/FAB REACTOR complete all as directed. (Pocket No:05)
Cleaning and removing of sludge from walls/floor of two nos MBBR/FAB REACTOR of size 4.8 x 4.8 x 6.1 mtr each with the help of wire brushes, steel patti/emery paper and depositing where directed by Engr-in-Charge at a distance of 100 mtr away from outer wall of STP including after cleaning painting to MS pipe two nos of size 300 mm dia, 6.1 mtr length each fixed in vertical position by using black bitumen paint and white wash to walls of MBBR/FAB REACTOR complete all as directed. (Jadunath STP)
Cleaning and removing of sludge from walls/floor of two nos MBBR/FAB REACTOR of diameter 6.20 upto the depth of 5mtr with the help of wire brushes, steel patti/emery paper and depositing where directed by Engr-in-Charge at a distance of 100 mtr away from outer wall of STP including after cleaning painting to MS pipe two nos of size 300 mm dia, 6.1 mtr length each fixed in vertical position by using black bitumen paint and white wash to walls of MBBR/FAB REACTOR complete all as specified and directed.(Ranjit/Govind STP)
Cleaning and removing of sludge from walls/floor of two nos MBBR/FAB REACTOR of size 4.40mtr x 3.70mtr x 6 mtr each with the help of wire brushes, steel patti/emery paper and depositing where directed by Engr-in-Charge at a distance of 100 mtr away from outer wall of STP including after cleaning painting to MS pipe two nos of size 300 mm dia, 6.1 mtr length each fixed in vertical position by using black bitumen paint and white wash to walls of MBBR/FAB REACTOR complete all as specified and directed.(Shivaji STP)
Cleaning and removing of sludge from walls/floor of tube settler tank of size 6.0 x 2.40 x 2.75 mtr each after taking out the tube settler media with the help of wire brushe/steel patti/emery paper and depositing wher directed at a distance 100 mtr away from outer wall of STP including taking out old rusted wire mesh of size 25 x 25 mm from tube settler media and cleaning the tube settler after all cleaning fixing wire mesh of same size with the tube settler and fixed in original position in the tube settler tank including painting to steel surfaces by using black bitumen paint and white wash to walls complete all as directed. (Pocket No:10)
Cleaning and removing of sludge from walls/floor of tube settler tank of size 4.5 x 1.75 x 2.75 mtr each after taking out the tube settler media with the help of wire brushe/steel patti/emery paper and depositing wher directed at a distance 100 mtr away from outer wall of STP including taking out old rusted wire mesh of size 25 x 25 mm from tube settler media and cleaning the tube settler after all cleaning fixing wire mesh of same size with the tube settler and fixed in original position in the tube settler tank including painting to steel surfaces by using black bitumen paint and white wash to walls complete all as directed.(Pocket No:12)
Cleaning and removing of sludge from walls/floor of tube settler tank of size 7.5 x 2.70 x 2.75 mtr each after taking out the tube settler with the help of wire brushe/steel patti/emery paper and depositing wher directed at a distance 100 mtr away from outer wall of STP including taking out old rusted wire mesh of size 25 x 25 mm from tube settler and cleaning the tube settler after all cleaning fixing wire mesh of same size with the tube settler and fixed in original position in the tube settler tank including painting to steel surfaces by using black bitumen paint and white wash to walls complete all as directed. (Pocket No:01 & 08)
Cleaning and removing of sludge from walls/floor of tube settler tank of size 8.0 x 3.5 x 2.75 mtr each after taking out the tube settler media with the help of wire brushe/steel patti/emery paper and depositing wher directed at a distance 100 mtr away from outer wall of STP including taking out old rusted wire mesh of size 25 x 25 mm from tube settler media and cleaning the tube settler after all cleaning fixing wire mesh of same size with the tube settler and fixed in original position in the tube settler tank including painting to steel surfaces by using black bitumen paint and white wash to walls complete all as directed. (Jadunath STP)
Cleaning and removing of sludge from walls/floor of tube settler tank of size 7.10 x 2.50 x 2.75mtr each after taking out the tube settler media with the help of wire brushe/steel patti/emery paper and depositing wher directed at a distance 100 mtr away from outer wall of STP including taking out old rusted wire mesh of size 25 x 25 mm from tube settler media and cleaning the tube settler after all cleaning fixing wire mesh of same size with the tube settler and fixed in original position in the tube settler tank including painting to steel surfaces by using black bitumen paint and white wash to walls complete all as directed. (STP-05)
Cleaning and removing of sludge from walls/floor of tube settler tank of size 7mtr x 5mtr x 4mtr each after taking out the tube settler media with the help of wire brushe/steel patti/emery paper and depositing wher directed at a distance 100 mtr away from outer wall of STP including taking out old rusted wire mesh of size 25 x 25 mm from tube settler media and cleaning the tube settler after all cleaning fixing wire mesh of same size with the tube settler and fixed in original position in the tube settler tank including painting to steel surfaces by using black bitumen paint and white wash to walls complete all as specified and directed.(Ranjit/Govind Colony STP)
Cleaning and removing of sludge from walls/floor of tube settler tank of size 4.40 x 4.10 x 3mtr each after taking out the tube settler media alongwith cleaning of clarifier contact tank of size 6.40 x 4.4 x 5.5mtr, with the help of wire brushe/steel patti/emery paper and depositing wher directed at a distance 100 mtr away from outer wall of STP including taking out old rusted wire mesh of size 25 x 25 mm from tube settler media and cleaning the tube settler after all cleaning fixing wire mesh of same size with the tube settler and fixed in original position in the tube settler tank including painting to steel surfaces by using black bitumen paint and white wash to walls complete all as specified and directed.(Shivaji Enclave STP)
Dewatering/bailing out stagnated secondary treated sewage and scraching the inner surface of the filter feed tank and chlorine contact tank of dimension 3.65 x2.4 x2.4 mtr with the help of wire brush, steel patti and emercy paper and removing any silt, sludge, raw material of sewage from the tank with the help of any T & P as required and throwing it away 100 mtr from the STP complete all as directed. (Pkt-01&08)
Dewatering/bailing out stagnated secondary treated sewage and scraching the inner surface of the filter feed tank and chlorine contact tank of dimension 2.0 x2.0 x1.9 mtr with the help of wire brush, steel patti and emercy paper and removing any silt, sludge, raw material of sewage from the tank with the help of any T & P as required and throwing it away 100 mtr from the STP complete all as directed. (Pkt-12)
Dewatering/bailing out stagnated secondary treated sewage and scraching the inner surface of the filter feed tank and chlorine contact tank of dimension 2.875 x1.8 x2.5 mtr with the help of wire brush, steel patti and emercy paper and removing any silt, sludge, raw material of sewage from the tank with the help of any T & P as required and throwing it away 100 mtr from the STP complete all as directed.(Pkt-10)
Dewatering/bailing out stagnated secondary treated sewage and scraching the inner surface of the filter feed tank of dimension 7.10 x 1.375 x 1.8 mtr with the help of wire brush, steel patti and emercy paper and removing any silt, sludge, raw material of sewage from the tank with the help of any T & P as required and throwing it away 100 mtr from the STP complete all as directed. (Pkt-05)
Dewatering/bailing out stagnated secondary treated sewage and scraching the inner surface of the filter feed tank and chlorine contact tank of dimension 8.0 x 1.75 x 2.0 mtr with the help of wire brush, steel patti and emercy paper and removing any silt, sludge, raw material of sewage from the tank with the help of any T & P as required and throwing it away 100 mtr from the STP complete all as directed. (Jadunath STP)
Dewatering/bailing out stagnated secondary treated sewage and scraching the inner surface of the filter feed tank of dimension 10m x 10m x 3.60m with the help of wire brush, steel patti and emercy paper and removing any silt, sludge, raw material of sewage from the tank with the help of any T & P as required and throwing it away 100 mtr from the STP. all as directed by Engineer-in-charge.(Ranjit/Govind colony STP)
Dewatering/bailing out stagnated secondary treated sewage and scraching the inner surface of the filter feed tank and chlorine contact tank of dimension 4.90m x 3.4m x 4m with the help of wire brush, steel patti and emercy paper and removing any silt, sludge, raw material of sewage from the tank with the help of any T & P as required and throwing it away 100 mtr from the STP. all as directed by Engineer-in-charge.(Shivaji Enclave STP)
Cleaning of existing DMF by opening the lid 500 mm dia and removing complete manually, remove water strainer and refix the same after necessary modification, cleaning and topping of media as required quantity of size 2.30m dia and height 1.65m complete all as directed. (Pocket No:01 & 08)
Cleaning of existing ACF by opening the lid 500 mm dia and removing complete manually, remove water strainer and refix the same after necessary modification, cleaning and topping of media as required quantity of size 2.30m dia and height 1.65m complete all as directed. (Pocket No:01 & 08)
Cleaning of existing DMF by opening the lid 500 mm dia and removing complete manually, remove water strainer and refix the same after necessary modification, cleaning and topping of media as required quantity of size 1.82m dia and height 1.60m complete all as directed. (Pocket No:10)
Cleaning of existing ACF by opening the lid 500 mm dia and removing complete manually, remove water strainer and refix the same after necessary modification, cleaning and topping of media as required quantity of size 1.82m dia and height 1.60m complete all as directed. (Pocket No:10)
Cleaning of existing DMF by opening the lid 500 mm dia and removing complete manually, remove water strainer and refix the same after necessary modification, cleaning and topping of media as required quantity of size 1.24m dia and height 1.60m complete all as directed. (Pocket No:12)
Cleaning of existing ACF by opening the lid 500 mm dia and removing complete manually, remove water strainer and refix the same after necessary modification, cleaning and topping of media as required quantity of size 1.24m dia and height 1.60mm complete all as directed. (Pocket No:12)
Cleaning of existing DMF by opening the lid 500 mm dia and removing complete manually, remove water strainer and refix the same after necessary modification, cleaning and topping of media as required quantity of size 2.4m dia and height 1.85m complete all as directed. (Pocket No:05)
Cleaning of existing ACF by opening the lid 500 mm dia and removing complete manually, remove water strainer and refix the same after necessary modification, cleaning and topping of media as required quantity of size 2.4m dia and height 1.85 m complete all as directed. (Pocket No:05)
Cleaning of existing DMF by opening the lid 500 mm dia and removing complete manually, remove water strainer and refix the same after necessary modification, cleaning and topping of media as required quantity of size 2.3m dia and height 1.85m.(Ranjit/Govind Colony STP)
Cleaning of existing ACF by opening the lid 500 mm dia and removing complete manually, remove water strainer and refix the same after necessary modification, cleaning and topping of media as required quantity of size 2.30m dia and height 1.85m.(Ranjit/Govind Colony STP)
Cleaning of existing DMF by opening the lid 500 mm dia and removing complete manually, remove water strainer and refix the same after necessary modification, cleaning and topping of media as required quantity of size 2.4m dia and height 3m.(Shivaji Enclave STP)
Cleaning of existing ACF by opening the lid 500 mm dia and removing complete manually, remove water strainer and refix the same after necessary modification, cleaning and topping of media as required quantity of size 2.4m dia and height 3m.(Shivaji Enclave STP)
Removing silt sludge and other raw material from kaccha drain with the help of JCB/Tractor and removing the sludge and depoisiting the same 50 mtr away from the starting edge of drain complete all as required at site .Note - All cost of T&P and other safety measures should be taken by the contractorwith out any extra cost complete all as directed. (STP-5) & Jadunath STP
Taking out mud, coarse sand, fine sand, grit and gravel from 06 Nos sludge beds and removing to a distance not exc 50 mtr fromouter edge of Sewage treatment plant. cleaning the filter media with water and restacking as per original complete all as directed. Note :- Cleaning of filter media, channels, drains etc shall be included in the quoted rate.
Taking out solid dry sewage waste from sludge beds of size 5.0x5.0x1.0 mtr and removing to a distance not exc 50 mtr from outer edge of Sewage treatment plant for further disposal complete all as directed.(Pocket No:10)
Taking out solid dry sewage waste from sludge beds of size 6.7x6.7x1.0 mtr and removing to a distance not exc 50 mtr from outer edge of Sewage treatment plant for further disposal complete all as directed. (Pocket No:01 & 08)
Taking out solid dry sewage waste from sludge beds of size 3.7x3.7x1.0 mtr and removing to a distance not exc 50 mtr from outer edge of Sewage treatment plant for further disposal complete all as directed. (Pocket No:12)
Taking out solid dry sewage waste from sludge beds of size 5.40 x5.40 x 1.0 mtr and removing to a distance not exc 50 mtr from outer edge of Sewage treatment plant for further disposal complete all as directed. (Pocket No:05)
Taking out solid dry sewage waste from sludge beds of size 5.60 x 5.60 x1.0mtr and removing to a distance not exc 50 mtr from outer edge of Sewage treatment plant for further disposal complete all as directed. (Jadunath STP)
Taking out solid dry sewage waste from sludge beds of size 4.7m x 5.35m x 1m and removing to a distance not exc 50 mtr from outer edge of Sewage treatment plant for further disposal complete all as directed.(Ranjit/Govind Colony STP)
Taking out solid dry sewage waste from sludge beds of size 5m x 3m x 2.1m and removing to a distance not exc 50 mtr from outer edge of Sewage treatment plant for further disposal alongwith additional Sludge Bed Tank of size 8.7m x 4.4m x 2.5m complete all as directed (Shivaji Enclave STP).
M&L for filling/laying the layer of naturally rounded graded gravel (white or yellow/grey/brownish) free from clay, dirt, vegetable and organic matter and should be hard, durable and superior quality of graded 50 mm first bottom layer of sludge bed in depths as per original pattern complete all as directed.
M&L for filling/laying sand free from clay, dirt, vegetable and organic matter over the second layer of rounded graded gravel of sludge bed in depths as per original pattern complete all as directed.
M&L for area cleaning under pumphouse premises as cutting/scraping of grass, unwanted trees, plant, levelling of earth surfaces, filling of digs etc complete all as directed. (Dimension of concerned area 60 m x 40m) .(Jadunath STP)
Supply and fixing in repair Cast Iron butterfly valves of size 100 mm dia complete all as directed. Make: LEADER / KIRLOSKAR / UPADHYA / L&T / ZOLOTO / NORMEX VALVES PVT LTD, PUNE.
Supply and fixing in repair Cast Iron butterfly valves of size 80 mm dia complete all as directed. Make: LEADER / KIRLOSKAR / UPADHYA / L&T / ZOLOTO / NORMEX VALVES PVT LTD, PUNE.
Supply and fixing in repair Cast Iron butterfly valves of size 50 mm dia complete all as directed. Make: LEADER / KIRLOSKAR / UPADHYA / L&T / ZOLOTO / NORMEX VALVES PVT LTD, PUNE.
Dismantling the electric induction motor AC 3 Phase, capacity up to 3.0 HP, 440 V, 1440 RPM, 50 Cycle of any make and type from the foundation and pump after disconnecting electric cable connection and earthing etc. and transportation to civil workshop for repair/rewinding, strip opening the motor and removing of defective burnt winding, rewinding the motor after cleaning the rotor and stator with super enameled copper winding wire of suitable turn and gauge as per the original with proper insulation including varnishing, providing all high grade material and class ‘B’ varnish for insulation, re-assembling the complete motor and installing at site with electric cable connection, earthing and testing the motor on full load at site after coupling the pump for its serviceability up to entire satisfaction of Engineer-in-charge.
All as per srl item No. 65 here-in-before but electric motor of capacity 4.7 HP to 5 HP.
All as per srl item No. 65 here-in-before but electric motor of capacity 7.5 HP to 8 HP.
All as per srl item No. 65 here-in-before but electric motor of capacity 10.0 HP to 11.9 HP
All as per srl item No. 65 here-in-before but electric motor of capacity 12.5 HP.
All as per srl item No. 65 here-in-before but electric motor of capacity 20 HP.
All as per srl item No. 65 here-in-before but electric motor of capacity 40 HP. Note for serial item No. 65 to 71 :- (i) Super enameled copper winding wire shall be measured and paid separately under appropriate item of this BOQ as supply only. (ii) Ball bearing if required shall be measured and paid separately under appropriate item of this BOQ as supply only. (iii) The T & P/vehicles etc.will be arranged by the contractor and the cost deemed to be included in the quoted rates. (iv) Any minor repairs such as re-matling/filling,grinding,welding and minor spares such as nuts,bolts,washers,'O' rings etc are deemed to be inclusive of the quoted rates.
Disconnecting the centrifugal/monoblock pumping sets of capacity up to 3 HP any make and model from motor and all water connections and removing/taking up from foundation transporting to civil workshop for repair/strip opening and repairing of pumping sets by changing defective/unserviceable parts such as bearing,shaft,impeller,bush,gland plate etc complete.Re-assembling including oiling greasing replacement of worn out nuts,bolts gasket etc,and installing in its original position at site making all connection ,commissioning and testing etc complete all as directed.
All as per srl item No. 72 here-in-before but centrifugal/monoblock pumping set of Capacity 5HP.
All as per srl item No. 72 here-in-before but centrifugal/monoblock pumping set of Capacity 7.5HP.
All as per srl item No. 72 here-in-before but centrifugal/monoblock pumping set of Capacity 10 HP.
All as per srl item No. 72 here-in-before but centrifugal/monoblock pumping set of Capacity 12.5HP.
All as per srl item No. 72 here-in-before but centrifugal/monoblock pumping set of Capacity 20HP.
All as per srl item No. 72 here-in-before but centrifugal/monoblock pumping set of Capacity 40HP. Notes for serial item No. 72 to 78: (i) Ball bearing shaft impeller bush gland plate & stuffing box packing etc replaced as per requirement shall be measured and paid separetly under appropriate item of this BOQ as supply only. (ii) The rates for minor repair of all other minor items essential for functioning the pump are deemed to be included in quoted rates. (iii) The T & P /vehicles etc will be arranged by the contractor and cost deemed to be included in the quoted rates.
Supply only steel distance pieces suitable upto 40 HP centrifugal/monoblock pumping sets complete all as directed. Make :- Kirloskar / As per Sample
Supply only gland plates with studs/ eye bolt suitable for centrifugal/monoblock pumping set of capacity up to 3 HP pumping set of any make complete all as directed.
Supply only gland plates with studs/ eye bolt suitable for centrifugal/monoblock pumping set of Capacity 5 HP pumping set of any make complete all as directed.
Supply only gland plates with studs/ eye bolt suitable for centrifugal/monoblock pumping set of Capacity 7.5HP pumping set of any make complete all as directed.
Supply only gland plates with studs/ eye bolt suitable for centrifugal/monoblock pumping set of Capacity 10 HP pumping set of any make complete all as directed.
Supply only gland plates with studs/ eye bolt suitable for centrifugal/monoblock pumping set of Capacity 12.5 HP pumping set of any make complete all as directed.
Supply only gland plates with studs/ eye bolt suitable for centrifugal/monoblock pumping set of Capacity 20 HP pumping set of any make complete all as directed.
Supply only gland plates with studs/ eye bolt suitable for for centrifugal/monoblock pumping set of Capacity 40 HP pumping set of any make complete all as directed.
Supply only carbon steel shaft high tensile strength with key suitable for centrifugal/monoblock pumping set of capacity up to 3HP. Make- Kirloskar, complete all as directed.
Supply only carbon steel shaft high tensile strength with key suitable for centrifugal/monoblock pumping set of Capacity 5 HP. Make- Kirloskar, complete all as directed.
Supply only carbon steel shaft high tensile strength with key suitable forcentrifugal/monoblock pumping set of Capacity 7.5HP. Make- Kirloskar, complete all as directed.
Supply only carbon steel shaft high tensile strength with key suitable forcentrifugal/monoblock pumping set of Capacity 10 HP Make- Kirloskar, complete all as directed.
Supply only carbon steel shaft high tensile strength with key suitable forcentrifugal/monoblock pumping set of Capacity 12.5HP. Make- Kirloskar, complete all as directed.
Supply only carbon steel shaft high tensile strength with key suitable for centrifugal/monoblock pumping set of Capacity 20HP. Make- Kirloskar, complete all as directed.
Supply only carbon steel shaft high tensile strength with key suitable for centrifugal/monoblock pumping set of Capacity 40 HP. Make- Kirloskar, complete all as directed.
Supply only cast iron impeller suitable for centrifugal/monoblock pumping set of capacity up to 3HP. Make- Kirloskar as per Sample complete all as directed by Engineer-in-charge.
Supply only cast iron impeller suitable for centrifugal/monoblock pumping set of Capacity 5HP. Make- Kirloskar
Supply only cast iron impeller suitable forcentrifugal/monoblock pumping set of Capacity 7.5 HP. Make- Kirloskar
Supply onlycast iron impeller suitable forcentrifugal/monoblock pumping set of Capacity 10 HP. Make- Kirloskar
Supply only cast iron impeller suitable for centrifugal/monoblock pumping set of Capacity 12.5 HP. Make- Kirloskar
Supply only cast iron impeller suitable for centrifugal/monoblock pumping set of Capacity 15 HP. Make- Kirloskar.
Supply only cast iron impeller suitable for centrifugal/monoblock pumping set of Capacity 40 HP. Make- Kirloskar
Supply only super enameled copper winding wire for rewinding the electric motors complete all as directed. Note :- Labour for motor winding shall be inclusive in respective items of rewinding.
Supply and fixing in repair ball bearing of DE & NDE for electric induction motor of capacity up to 3.0 HP complete all as directed.
Supply and fixing in repair ball bearing of DE & NDE for electric induction motor of capacity 5.0 HP complete all as directed.
Supply and fixing in repair ball bearing of DE & NDE for electric induction motor of capacity 7.5 HP complete all as directed.
Supply and fixing in repair ball bearing of DE & NDE for electric induction motor of capacity 10 HP complete all as directed.
Supply and fixing in repair ball bearing of DE & NDE for electric induction motor of capacity 12.5 HP complete all as directed.
Supply and fixing in repair ball bearing of DE & NDE for electric induction motor of capacity 20 HP complete all as directed.
Supply and fixing in repair ball bearing of DE & NDE for electric induction motor of capacity 40 HP complete all as directed. Make for serial item No. 102 to 108 :- SKF/NBC.
Lifting the submersible pump and motor of capacity upto 3 HP complete after disconnecting electric cable connection and transportating to civil workshop and back for repair and rewinding the submersible electric motor 3 HP by using PVC insulated copper conductor winding wire of suitable turn and gauge as per the original,reassembling the complete submersible pump and motor lowering including reconnecting the electric cable connection and testing complete all as directed.
All as per srl item No. 109 here-in-before but submersible pump and motor of capacity 3.5 HP.
All as per srl item No. 109 here-in-before but submersible pump and motor of capacity 4.0HP.
All as per srl item No. 109 here-in-before but submersible pump and motor of capacity 5.0HP
All as per srl item No. 109 here-in-before but submersible pump and motor of capacity 7.5 HP .
All as per srl item No. 109 here-in-before but submersible pump and motor of capacity 10 HP.
All as per srl item No. 109 here-in-before but submersible pump and motor of capacity 25 HP.
Supply and fixing in repair mechanical seal & oil seal for pumping set of capacity 1.5 HP to 1.5 HP complete all as directed.
Supply and fixing in repair mechanical seal & oil seal for pumping set of capacity 2 HP to 3.5 HP complete all as specified and as directed.
Supply and fixing in repair mechanical seal & oil seal for pumping set of capacity 4.0 HP to 5 HP complete all as directed.
Supply and fixing in repair mechanical seal & oil seal for pumping set of capacity 7.5 HP to 10 HP complete all as directed.
Supply and fixing in repair mechanical seal & oil seal for pumping set of capacity 12.5 HP complete complete all as directed.
Supply and fixing in repair mechanical seal & oil seal for pumping set of capacity 20 HP complete complete all as directed.
Supply and fixing in repair mechanical seal & oil seal for pumping set of capacity 25 HP complete complete all as directed.
Supply and fixing in repair mechanical seal & oil seal for pumping set of capacity 40 HP complete complete all as directed.
Supply and fixing in repair mechanical seal & oil seal for pumping set of capacity 60 HP complete complete all as directed.
Supply and fixing in repair Relay range of (1.6 -2.5 Amps ) for 1.5-2.0 HP starter(Dol/Star delta) complete all as directed.
Supply and fixing in repair fixing in repair Relay range (4.0-6.0 Amps ) for 3.0 HP starter(Dol/Star delta) ocomplete all as directed.
Supply and fixing in repair Relay range (5.5-8.0 Amps ) for 3.5 HP starter(Dol/Star delta) ocomplete all as directed.
Supply and fixing in repair Relay range (5.5-8.0 Amps ) for 4 HP starter(Dol/Star delta) ocomplete all as directed.
Supply and fixing in repair Relay range (5.5-8.0 Amps ) for 5 HP starter(Dol/Star delta) ocomplete all as directed.
Supply and fixing in repair Relay range (9.0-14.0 Amps ) for 7.5 HP starter(Dol/Star delta) ocomplete all as directed.
Supply and fixing in repair Relay range (14.0-22.0 Amps ) for 10 HP to 12.5 HP starter(Dol/Star delta) ocomplete all as directed.
Supply and fixing in repair Relay range (23.0-32.0Amps ) for 20 HP to 25 HP starter(Dol/Star delta) ocomplete all as directed.
Supply and fixing in repair Relay range (45.0-75.0 Amps ) for 40 HP to 60 HP starter(Dol/Star delta) ocomplete all as directed. Make for serial item No. 126 to 134: C & S/L & T/Equivalent
Supply only PVC copper winding wire as per exixting for submersible pump and motor complete all as directed.
Supply and fixing in repair Belts of suitable size B-56 for Air Blower electric motor complete all as directed.
Supply and fixing in replacement Belts of suitable size B-48 for Air Blower electric motor complete all as directed.
Supply and fixing in repair Belts of suitable size B-57 for Air Blower electric motor complete all as directed.
Supply and fixing in repair Belts of suitable size B-52 for Air Blower electric motor complete all as directed.
Supply and fixing in repair power Contactors 415 volts ,50 cycles,3 phase, MNX-A2 complete all as directed.
Supply and fixing in repair power Contactors 415 volts ,50 cycles,3 phase, MNX A1 complete all as directed.
Supply and fixing in repair power Contactors 415 volts ,50 cycles,3 phase MCX 33 complete all as directed. Make for serial item No. 140 to 142:- L & T/ Havells/ Siemens/BCH/Legrand/Indo Asian
Supply and fixing in repair ball bearing for Air blower of capacity upto 7.5HPcomplete all as directed.
Supply and fixing in repair ball bearing for Air blower of capacity upto 8.5 HP to 11.9 HP complete all as directed.
Supply and fixing in repair ball bearing for Air blower of capacity upto 15HP to 20 HP complete all as directed.
Supply and fixing in repair ball bearing for Air blower of capacity upto 25 HP to 40 HP complete all as directed. Make for serial item No. 143 to 146: SKF/NBC.
Supply only chlorine dioxide powder (SCK 10K) chemical for treatment of raw sewage treated water complete all as directed. Make: M/S Bharti Waters Pvt. Ltd. or equivalent.
S&F in repair flexible tyre coupling size TC -014 including making alignment of pump and motor complete all as directed. Make - Unitech
Supply only leather buffalow superior quality as per sample complete all as directed.
Supply only oil imeressed graphite gland packing off sizes of superior quality along with grease and cotton waste complete all as directed. Make - Champion
Supply only air compressor oil for air blower complete all as directed.
SS CONSTRUCTION
RS ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .