| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹35.1 L+₹78,372.29 (2.29%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹36.9 L+₹2.6 L (7.65%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹37.0 L+₹2.7 L (7.94%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹37.7 L+₹3.5 L (10.1%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN L1 |
| Sl No | Description | Qty | Unit | SINGH CONST CO L7 | VIRINDER SINGH L13 | M/S SHREE RAM DUBEY AND SONS L3 | jyoti parkash sharma L1 | RAMAN CONSTRUCTION CO L4 | M/S IMRAN MAJID L11 | AKBAR FURNITURE HOUSE AND TIMBER MERCHANT L9 | JOGINDER SINGH L10 | khajuria builders L5 | PARDEEP SHARMA L14 | M/S R S Builders L12 | RAJ MOHD L8 | M/S Ashok Kumar Jaswal L6 | M/S SUSHEEL KUMAR Govt. CONTRACTOR L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavating in post holes (or similar holes ) each n. exc 0.5 cum in any type of soil getting out, returning filling in and ramming around in layers not exceeding 25cm complete all as specified and as directed. | 22 | Each | 80 ₹1,760 | 200 ₹4,400 | 100 ₹2,200 | 170 ₹3,740 | 200 ₹4,400 | 200 ₹4,400 | 100 ₹2,200 | 500 ₹11,000 | 80 ₹1,760 | 500 ₹11,000 | 200 ₹4,400 | 100 ₹2,200 | 90 ₹1,980 | 15 ₹330 Lowest |
| 2.00 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in any type of soil etc complete all as specified and as directed. | 586 | Sqm | 25 ₹14,650 | 15 ₹8,790 | 20 ₹11,720 | 35 ₹20,510 | 20 ₹11,720 | 100 ₹58,600 | 20 ₹11,720 | 200 ₹1,17,200 | 20 ₹11,720 | 200 ₹1,17,200 | 150 ₹87,900 | 50 ₹29,300 | 30 ₹17,580 | 5 ₹2,930 Lowest |
| 3.00 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out and getting out in any type of soil complete all as specified and directed. | 204.64 | Cum | 120 ₹24,556.8 | 200 ₹40,928 | 180 ₹36,835.2 | 120 ₹24,556.8 | 150 ₹30,696 | 200 ₹40,928 | 100 ₹20,464 | 200 ₹40,928 | 100 ₹20,464 | 350 ₹71,624 | 100 ₹20,464 | 150 ₹30,696 | 190 ₹38,881.6 | 90 ₹18,417.6 Lowest |
| 4.00 | Returning filling in including spreading leveling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and as directed. | 108.17 | Cum | 50 ₹5,408.5 | 30 ₹3,245.1 | 120 ₹12,980.4 | 55 ₹5,949.35 | 50 ₹5,408.5 | 300 ₹32,451 | 20 ₹2,163.4 Lowest | 200 ₹21,634 | 100 ₹10,817 | 150 ₹16,225.5 | 50 ₹5,408.5 | 80 ₹8,653.6 | 50 ₹5,408.5 | 50 ₹5,408.5 |
| 5.00 | Removing excavated material n exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed. | 96.47 | Cum | 50 ₹4,823.5 | 25 ₹2,411.75 Lowest | 150 ₹14,470.5 | 55 ₹5,305.85 | 50 ₹4,823.5 | 200 ₹19,294 | 30 ₹2,894.1 | 150 ₹14,470.5 | 50 ₹4,823.5 | 100 ₹9,647 | 60 ₹5,788.2 | 80 ₹7,717.6 | 50 ₹4,823.5 | 50 ₹4,823.5 |
| 6.00 | Taking down cement plaster of any descreption on brick/stone walls or concrete surfaces including racking out joints, hacking for key scrubbing down with water etc on walls and ceiling, complete all as specified and directed. | 22 | Sqm | 5 ₹110 Lowest | 5 ₹110 Lowest | 10 ₹220 | 8 ₹176 | 20 ₹440 | 100 ₹2,200 | 5 ₹110 Lowest | 10 ₹220 | 10 ₹220 | 10 ₹220 | 10 ₹220 | 12 ₹264 | 95 ₹2,090 | 5 ₹110 Lowest |
| 7.00 | Demolition Cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed. | 10.55 | Cum | 200 ₹2,110 | 100 ₹1,055 | 200 ₹2,110 | 100 ₹1,055 | 100 ₹1,055 | 100 ₹1,055 | 100 ₹1,055 | 100 ₹1,055 | 100 ₹1,055 | 100 ₹1,055 | 200 ₹2,110 | 210 ₹2,215.5 | 20 ₹211 Lowest | 50 ₹527.5 |
| 8.00 | M&L PCC 1:4:8 type D-2 (using 40 mm graded stone agg) as in foundation complete all as specified and as directed. | 19 | Cum | 2,600 ₹49,400 | 3,000 ₹57,000 | 2,800 ₹53,200 | 2,000 ₹38,000 | 1,500 ₹28,500 Lowest | 3,500 ₹66,500 | 2,200 ₹41,800 | 2,000 ₹38,000 | 2,000 ₹38,000 | 4,500 ₹85,500 | 3,000 ₹57,000 | 2,700 ₹51,300 | 4,200 ₹79,800 | 2,500 ₹47,500 |
| 9.00 | M&L for cement concrete type B1 1:2:4 (using 20 mm gradded aggregate) use in coping, gola, hold fast and similar work including naccesary form work complete all as specified and directed. | 24 | Cum | 4,500 ₹1,08,000 | 5,000 ₹1,20,000 | 4,000 ₹96,000 Lowest | 4,500 ₹1,08,000 | 4,000 ₹96,000 Lowest | 4,000 ₹96,000 Lowest | 4,500 ₹1,08,000 | 4,500 ₹1,08,000 | 4,200 ₹1,00,800 | 5,500 ₹1,32,000 | 4,000 ₹96,000 Lowest | 4,600 ₹1,10,400 | 5,500 ₹1,32,000 | 4,200 ₹1,00,800 |
| 10.00 | M&L for RCC M-25 (20mm graded aggregate) as in foundations footings, plinth beams etc all as specified & directed. | 23 | Cum | 6,800 ₹1,56,400 | 8,000 ₹1,84,000 | 5,500 ₹1,26,500 | 5,500 ₹1,26,500 | 4,700 ₹1,08,100 | 4,200 ₹96,600 Lowest | 7,500 ₹1,72,500 | 10,000 ₹2,30,000 | 5,500 ₹1,26,500 | 6,000 ₹1,38,000 | 6,000 ₹1,38,000 | 7,000 ₹1,61,000 | 6,500 ₹1,49,500 | 5,000 ₹1,15,000 |
Tender Value
₹48.5 L
EMD Value
₹98,000
Closing Date
17 Jul 2025, 6:00 pmClosed
GARRISON ENGINEER SOUTH UDHAMPUR
GARRISON ENGINEER SOUTH UDHAMPUR
PROVN OF COMPOUND WALL COVERED PARKING SHED WITH HARDSTANDING CONNECTING COVERED CORRIDOR AND ROOF TREATMENT OF BLDG NO P134 AND PROVN OF COLLAPSIBLE GATE AND ALLIED INFRA AT MAIN ENTRANCE OF BLDG NO P113 UNDER GE SOUTH UDHAMPUR
2025_MES_716964_1
GE/S(U)-60/2025-26
Open Tender
Civil Works
Works
240 days
GE SOUTH UDHAMPUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE SOUTH UDHAMPUR
₹98,000
22 Sept 2025
26 Jun 2025
19 Jul 2025
26 Jun 2025
17 Jul 2025
10 Jul 2025
Amount
Excavating in post holes (or similar holes ) each n. exc 0.5 cum in any type of soil getting out, returning filling in and ramming around in layers not exceeding 25cm complete all as specified and as directed.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in any type of soil etc complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out and getting out in any type of soil complete all as specified and directed.
Returning filling in including spreading leveling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and as directed.
Removing excavated material n exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.
Taking down cement plaster of any descreption on brick/stone walls or concrete surfaces including racking out joints, hacking for key scrubbing down with water etc on walls and ceiling, complete all as specified and directed.
Demolition Cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L PCC 1:4:8 type D-2 (using 40 mm graded stone agg) as in foundation complete all as specified and as directed.
M&L for cement concrete type B1 1:2:4 (using 20 mm gradded aggregate) use in coping, gola, hold fast and similar work including naccesary form work complete all as specified and directed.
M&L for RCC M-25 (20mm graded aggregate) as in foundations footings, plinth beams etc all as specified & directed.
M&L for RCC M-25 (20mm graded aggregate) as in columns, pillars etc all as specified & directed.
M&L for RCC M-25 (20mm graded aggregate) as in beams, lintels etc all as specified & directed.
M&L for RCC M-25 (20mm graded aggregate) as in slab type Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M&L 75 mm thick PCC 1:4:8 type D2 using 40 mm graded aggregate as in sub base complete all as specified and as directed.
M & L 75mm th PCC 1:3:6 type C-2 as plinth protection, finished even and fair without using extra cement complete all as specified and as directed.
M&L for plain cement concrete1:2:4 type B-2 using 40 mm graded stone aggregate as in channels and drains, foundation and similar work etc complete all as specified and as directed.
M & L for PCC 1:2:4 Type B2 using 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
25 mm thick, Plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement, complete all as specified and as directed by Engr-in-Charge.
M&L for 75 mm thick pcc type C-2 1:3:6 , using 40mm graded crushed stone aggregate as in sub base for receiving floor finishes finished even and fair complete all specified and as directed.
M&L brick work with sub class B bricks, straight or curved on plan exc 6 m mean radium built in CM 1:6 all as specified and as directed.
M & L hardcore of broken stone or boulders of gauge exc. 63mm but n exc 100mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and well rammed to a true surface complete all specified and as directed.
M&L rendering 15mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces & finishing the surface even & smooth without using extra cement complete all as specified & directed.
M&L rendering 15mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces & finishing the surface even & smooth without using extra cement complete all as specified & directed.
M & L Rendering 10mm thick on brick or concrete surfaces of walls in CM (1:6) including finishing the surfaces fair and even without using extra cement all specified and as directed.
M&L Rendering 5mm thick on concrete surfaces in CM 1:3 as on ceiling all as specified and as directed.
M & L for applying 1 mm thick layer of wall putty on walls to give uniform surface, surface scrubed with emery paper and make surface good and clean complete all as specified and directed.
M & L for applying 3mm thick layer of wall putty on walls to give uniform surface, surface scrubed with emery paper and make surface good and clean complete all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all specified and as directed.
M&L for two or more coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified and as directed.
S&F TMT bars upto 10mm dia and over, cut to length, bent to shape required,including crancking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
S&F TMT bars 5mm and over upto and including 10mm dia in stirrups, spacers and binders bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia complete all specified and as directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all specified and as directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all specified and as directed.
Form work to soffit of suspended slabs such as roof slabs, floor slabs, landings and similar work, n exc 200mm thick (horizontal or sloping) complete all specified and as directed.
M & L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressumers, lintes,cantilevers, shelves including supports, overhangs, etc also splays beteen floors and beams finished rough surfaces of concrete complete all specified and as directed.
M & L for double charged glossy finished Vitrified tiles light Shade 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6 complete all specified and as directed.
M & L for Glazed coloured Ceramic tiles in vertical surface 300x450x7mm or 300x600x7mm thick laid over 10 mm thick screed bed in CM 1:4,set and joint in neat cement slurry and pointed in white or colour cement to match complete all specified and as directed.
M & L 18-20 mm thick granite (of any type) work( table rubbed and polished) in steps, jambs, pillars, window sills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite slab complete all as specified and as directed.
Material and labour for 12 mm thick toughened glass partition and similar work with fixing of stain less steel clit/stain less steel clamp and fixing aluminium frame wall and floor complete all as specified and as directed.
M & L for roughing surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc for local depressions RCC surface and brushing neat cement slurry with 3.0 Kg of cement per Sqm and will be finished and rendered with 10mm thick cement plaster in Cement Mortor 1:3 using water proofing compound and finished even and smooth without using extra cement and the sand used for the same will be clean and free from any silt, organic matter and impurities, RCC and plastered surface will be wet cured for minimum period laid down in IS 456 & then allowed to dry and leakage checked by pointed test at least 72 hrs. After checking of leakages on dry plaster surfaces complete all specified and as directed.
Material and labour for APP polymaric water proofing membrene minimum 3mm thick and weighting not less than 3.6 kg / sqm of make 'Moply FP' manufactured by STP Texsa Ltd or' Hyper Plas' ( polyster) manufactured by M/S IWL Ltd or'Shaliplas' (polyster) manufactured by M/S Capital Steels and chemicals Pvt Ltd or 'Mak polyplast' manufactured by M/S M K Petro as approved by GE , black finished reinforced with non weven polyster matt,with fusable finish laid over compatable bitumen primer at the rate of 0.40 Ltr/Sqm torching overlaps with a propane or abutane gas torch, with a over lap of 75mm at the sides and100 at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufactur's instructions including 0.40 Ltr/Sqm torching overlaps with a propane or abutane gas torch, with a over lap of 75mm at the sides and100 at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufactur's instructions including preparation of surface, complete all as specified and as directed.
M & L for apply bituminous primer confiriming to IS -3384 @ 0.40 Kgs/ Sqm on prepared surface on sunny day. After the primed surface has dried and apply a coat of hot blown 85/25 penetration grade blown bitumen, confirming to IS -702@ 1.20kg/ Sqm on the surfaces. Provide APP (Atactiic Polypropylene) modified polymeric five layered membrane with central core of 100 micron high molecular high density firm. Minimum weight of membrance will be 3 kg/Sqm. APP membrance will be laid across the slope from lowest line sloping roof towards ridge with minimum end lap of 150 mm & side lap of 75mm bonded with hot blown bitumen. Over the APP membrance apply semi hot blown 85/25 penetration grade bitumen @ 1.20kg/ Sqm and blinded with fine sand in dry condition @ 0.50 kg/Sqm dusted over the bitumen coat. Note :- The laying of the membrane shall be got done by authorized applicator of the membrane manufacturer.
S&F rolled mild steel Fe-410w (Gde-E-250) quality 'B' Roof trusses (framed ) , trussed, purlins, crane gantries , rails, poles and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces cleats etc complete all specified and as directed.
Rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to grade Fe.290.Gde-E-165, steel work duly painted with one shop coat of zinc chromate primer including preparation of surfaces all specified and as directed.
Mild steel framed work such as grills, gratings with ends of bars shouldered or reveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar works, conforming to Fe-290, Gde E-165, complete all as specified and directed by Engr-in-Charge.
S & F Pre-painted galvatume aluminum zinc coating GI vased corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all specified and as directed.
M&L prepainted galvalume aluminium zink coating GI based plain steel sheet 0.50mm thick nridge ,hips ,valley gutters at the external end slope of camoflange pattren colour having tensile strength of 550Mpa fixed with self tapping screws complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new steel surfaces of any discripton not otherwise discribed over 10 cm width or girth and applying two coats of synthetic enamal paint over a coat of red oxide on steel surfaces complete all specified and as directed.
Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed.
Machine pressed (factory made) precast plain cement concrete 1:2:4 type B-1(20mm graded crushed stone aggregate), kerb stone & the like of size 300mm x 300mm x 100mm thick or of size as approved by GE, with plain fair faces including chamfers, weathering etc, embedding in position/laid in trenches on edges of roads, including excavation in any type of soil, setting in cement mortar (1:4) returning filling and removal of surplus soil/debris to a distance n.exc. 50m from the starting point, complete all as specified and directed.
S&F 110 mm PVC (SWR) pipes single socket in any length with rubber ring joints fixed to wall complete all as specified and as directed.
Supply only integral water proofing compound complete all specified and as directed.
S&F Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and as directed.
Point wiring for one light/ fan/bell point controlled by one switch using 1.5 Sq mm FRLSH copper conductor cables (multistranded) PVC insulated and unsheathed in and including PVC concealed conduit pipe as per site requirement (size not less than 20mm dia), medium grade with Modular sunken boxes & PVC/metal back plate for mounting modular type switches, sockets & regulators etc with cover plate modular type including supplying and laying PVC insulated and stranded unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire connected to earth dolly including cutting of chases in wall /ceiling etc and making good the disturbed surfaces match to existing with cement mortar and putty white /colour wash complete all as directed .Make : Havells/ Finolex/ Polycab
All as per srl item No 54 but for 3/5 pin 6 Amps socket outlet independent board including PVC insulated PVC unsheathed 2.5 sq mm earth wire and connected to earth dolly.
All as per srl item No 54 but for 3/5 pin 6 Amps socket outlet on the same board including PVC insulated PVC unsheathed 2.5 sq mm earth wire and connected to earth dolly.
All as per Srl item No 54 but for 3 Pin 16 Amps socket outlet independent board with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 2.5 sq mm earth wire standard and connected to earth dolly.
S&F for modular switch 6 Amps single pole one way 230 V, 50 Hz, AC , with inner and outer cover plate required module complete all as specified and directed by Engr In charge. Make: Havells(Crabtree)/ Legrand/L&T
S&F for modular switch 16 Amps single pole one way 230 V, 50 Hz, AC , with inner and outer cover plate required module complete all as specified and directed by Engr In charge. Make: Havells(Crabtree)/ Legrand/L&T
S&F for modular socket 3 Pin 6 Amps flush type 230 V, 50 Hz, AC, with inner and outer cover plate required module complete all as specified and directed by Engr In charge. Make: Havells(Crabtree)/ Legrand/L&T
S&F for modular socket combined 2-in-1, 6 Pin 6 & 16 Amps 230 V, 50 Hz, AC, flush type with inner and outer cover plate required module complete all as specified and directed by Engr In charge. Make: Havells(Crabtree)/ Legrand/L&T
M &L Ceiling rose, surface bakelite 65x 50mm three terminals fixed on PVC Round Block complete all as specified and directed by Engr In charge.
S & F MCB Three Pole & Neutral capacity of 63 amps 415 volts C Curve rupturing capacity 16 KA complete all as specified and directed.Make:- Havells/ legrand/ Schneider.
S & F MCB single pole 240 volt any rating from 10 to 40 amps "C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable
S & F MCB single pole and neutral 240 volt any rating from 32 Amps "C" series, with rupturing capacity 10 KA ,including providing thimble for out going cable Make:- Havells/ legrand/ Schneider.
S&F sheet metal enclosure for MCB DB double door type, single pole and neutral 8 way 240 Volts with suitable rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed.Make:- Havells/ legrand/ Schneider.
S&F sheet metal enclosure for MCB DB double door type, single pole and neutral 4 way 240 Volts with suitable rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed.Make:- Havells/ legrand/ Schneider.
S&F Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 6 Sqmm in PVC concealed conduit 25 mm dia including PVC insulated copper conductor cable 6 Sq mm as earth lead all as specified.Make : Havells/ Finolex/ Polycab
S&F Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 2.5 Sqmm in PVC concealed conduit 25 mm dia including PVC insulated copper conductor cable 2.5 Sq mm as earth lead all as specified. Make : Havells/ Finolex/ Polycab
Earthing complete with galvanized steel earth plate electrodes 600 mmx600 mm x6.3 mm thick buried directly in ground earth plate not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to and including galvanized steel earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and steel including PCC pit in PCC 1:2:4 type B-1using 20 mm graded crushed stone aggregate, RCC frame with 40mm thick RCC cover reinforced with 8mm dia deformed bars handle. including excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 15mm bore main board complete all as shown in electrical plate No 3 connected to main control board all as specified and testing on completion. Note: Excavation earthwork charcoal PCC pit is covered under this item including taking out existing earth plate etc.Note: if earth resistance of earthing is not found (2 to 5 Ω) satisfactory if will be redone by the contractor on his risk and cost.
Supply and fixing LED lights fitting 1x 20W, 230V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.Make - Havells / Bajaj/Wipro/Phillips
Supply and fixing LED building security light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp,clamps,suitable bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.Make - Havells / Bajaj//Wipro/Phillips
S&F Street light Bracket complete made of GI pipe of suitable size, medium grade 1.2 m long bent to shape as per site requirement along with MS flat iron clamps with nuts, bolts, washers including grouting the same with wall , all as specified and directed by Engg- in Charge.
Supply , Laying, Testing and commissioning cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm x 4 core size complete all specified and as directed.
M&L for sand cushioning with dry local sand for cable protecting under ground cable (8 cm before laying the cable and 15 cm after laying the cable) in trenches including punning the sand upto 18 cm thick and consolidated complete all as specified and directed.
Supply and laying dry well burnt locally available brick sub class 'B' modular bricks laid flat with width equal to the length of whole bricks over cable as cable protection complete all as specified and directed.
Supply and fixing GI tubing light grade 40 mm dia along the wall/ in trenches/ in duct / in culvert /road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles all as specified.
Supply and errection of S & F Continuously tapered hot dip galvanised octagonal cross sectional pole for Security Lights of height 7 mtr including suitable aluminium busbar with dipping method having bottom 130 mm A/F 3 mm thick conforming to ASTM A 572 Gr with yeild 450 MPA cut and folded to form an octagonal section and welded accordance with AWS for wind loading as per IS 875 part 3 1987 including following works:- (a) Excavation in trenches not exceeding 1.5 mtr wide & 1.57 mtr deep for pole foundation & getting out in soft/loose soil, returning filling in the excavated of soil after fixing the pole in foundation ramming earth around in layer not exceeding 25 cm thick and disposal of surplus soil to a distance not exceeding 50 mtrs complete all as specified and directed. (b) M&L for PCC 1:4:8, type D2 (using 40mm graded crushed stone aggregate) in foundation 900mmx600mm cross section and planting depth 1.5 mtr for concrete encasing the pole upto GL complete all as specified and directed. (c) M&L for providing PCC 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) for plinth block/collar above GL 500mm high and 450mm dia complete all as specified and directed. (d) M&L for TPN aluminium suitable rated Busbar having provn of nut bolt for termination of UG cable and 3 core 2.5 sqmm PVC insulated cable of required legth for street light connection (e) M&L for writing letter or figures (Block Roman, Italic as Indian) with thick synthetic enamel paint of apprised shade not exceeding 5 cm height including numbering of pole complete all as specified and directed. NOTE : Manufacture's test certificate will be produced before execution work.
Supply and fix LED street light luminaires 45 watt with pressure die cast aluminium housing with heat resistant toughned glass and IP66 protection complete including connection on pole including service connection complete all as specified and directed. Make- Crompton Greaves/Havells/Bajaj cat part no 169799 ‘EDGE’ streetlight
M/S SUSHEEL KUMAR Govt. CONTRACTOR (BID ID -3360387)
M/S SHREE RAM DUBEY AND SONS (BID ID -3362528)
RAMAN CONSTRUCTION CO (BID ID -3362573)
khajuria builders (BID ID -3361646)
M/S Ashok Kumar Jaswal (BID ID -3360832)
SINGH CONST CO (BID ID -3361404)
RAJ MOHD (BID ID -3362486)
AKBAR FURNITURE HOUSE AND TIMBER MERCHANT (BID ID -3360996)
JOGINDER SINGH (BID ID -3362577)
M/S IMRAN MAJID (BID ID -3361756)
M/S R S Builders (BID ID -3355933)
VIRINDER SINGH (BID ID -3362187)
PARDEEP SHARMA (BID ID -3362357)
stage.html
html • 0.08 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .