Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹52.6 L+₹2.6 L (5.23%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹54.7 L+₹4.7 L (9.45%)Rejected-Finance PB NO 809 ABERDEEN BAZAR PO ATLANTA POINT NEAR POLICE WIRELESS PORT BLAIR 744104 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744104 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹55.7 L+₹5.7 L (11.4%)Rejected-Finance 94A APR COLONY BILHARI JABALPUR MP | JABALPUR | MADHYA PRADESH | 482020 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹55.8 L+₹5.8 L (11.6%)Rejected-Finance 365 B 10 HENRY COMPLEX MATHIYAS NAGAR KP ROAD NAGERCOIL KANNIYAKUMARI DISTRICT 629001 | KANNIYAKUMARI | TAMIL NADU | 629001 | L5 | Rejected-Finance Not being L1 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
10 Feb 2023, 6:00 pmClosed
GE MINNIEBAY
GE Minniebay PJunglighat Post Minniebay Port Blair 744103
REPAIR MAINT AND REPLACEMENT OF SUB MAIN WIRING, DBS, KWH METER, SECURITY LIGHTS AND OTHER CONNECTED WORKS UNDER AGE EM-I AT GE MINNIE BAY PORT BLAIR
2023_MES_576338_1
8219/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
MINNIEBAY PORT BLAIR
AS PER TENDER DOCUMENTS
11 documents required · 11 mandatory
₹500
GE MINNIE BAY
₹98,000
Yes
4 Mar 2023
20 Jan 2023
13 Feb 2023
21 Jan 2023
10 Feb 2023
4 Feb 2023
Amount
Supply and fixing as in repair of vertical type of MCCB DB TPN 4 way IP-43 made of sheet steel phos phatised, powder painted with bus bar, neutral link, earth bar and Din rail ,415 Volts with double door complete all as specified and as directed by Engineer-in -charge. Note : Concealed the DBs on wall if required all including make in good and matching with existing surface.
Supply and fixing as in repair of Adujstable thermal & magnetic type of MCCB TP 16 KA breaking capacity 100 Amps complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of Adujstable thermal & magnetic type of MCCB TPN/FP 16 KA breaking capacity 63 Amps complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of vertical type of MCB DB TPN 6 way IP-43 made of sheet steel phos phatised, powder painted with bus bar, neutral link, earth bar and Din rail ,415 Volts with double door and refitting serviciable MCB TPN ,SP complete all as specified and as directed by Engineer-in -charge. Note : Concealed the DBs on wall all including make in good and matching with existing surface.
Supply fixing as in repair of MCB TPN 415 Volts, 'C' series, breaking capacity 10 KA of rating 40 Amps necessary connection and testing complete all as specified and as directed by Engineer-in -charge.
Supply fixing as in repair of MCB TPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 63 Amps necessary connection and testing complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of MCB SPN DB 12 way IP-43 made of sheet steel phos phatised, powder painted with bus bar, neutral link, earth bar and Din rail ,230 Volts with double door complete all as specified and as directed by Engineer-in -charge. Note : Concealed the DBs on wall as required all including make in good and matching with existing surface.
Supply and fixing as in repair of MCB SPN DB 8 way IP-43 made of sheet steel phos phatised, powder painted with bus bar, neutral link, earth bar and Din rail ,230 Volts with double door complete all as specified and as directed by Engineer-in -charge. Note : Concealed the DBs on wall as required all including make in good and matching with existing surface.
Supply and fixing as in repair of MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 40 Amps complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 63 Amps complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of MCB SP6-32 Amps complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of MCB SP 40 Amps complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of MCB SP 63 Amps complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of MCB blank plate from MCB DBs complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of three phase KWH meter 4 wire with LED Display, LED meter 10-60 Amp with Box complete all as specified and as directed by Engineer-in -charge. Note : Old KWH meter deposited to E/ M Store yard.
Supply and fixing as in repair of single phase KWH meter 2 wire with LED Display, LED meter 10-60 Amp with cristal Box complete all as specified and as directed by Engineer-in -charge. Note : Old KWH meter deposited to E/ M Store yard.
Supply and fixing as in repair of PVC energy meter seal with specifice no complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of single phase transparent PVC energy meter box with complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of three phase transparent PVC energy meter box with complete all as specified and as directed by Engineer-in -charge.
M&L for earthing complete with Galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mir deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanized earth strip 25x3 mm size connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 40 mm dia GI pipe medium grade for protection of GI earth lead and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type CI chamber. MS funnel, wire gauge. 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos. 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I. Note: (i) Cost of GI earth wire and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returninng & filling, PCC chamber pit, RCC cover & test point. (iii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit.
Supply and fixing as in repair ofnew multistranded copper conductor of size 1.5 Sqmm of any coloured complete all as specified and as directed.
Supply and fixing as in repair of multistranded copper conductor of size 2.5 Sqmm of any coloured complete all as specified and as directed.
Supply and fixing as in repair of multistranded copper conductor of size 4.0 Sqmm of any coloured complete all as specified and as directed.
Supply and fixing as in repair of multistranded copper conductor of size 6.0 Sqmm of any coloured complete all as specified and as directed.
Supply and fixing as in repair of multistranded copper conductor of size 10 Sqmm of any coloured complete all as specified and as directed.
Supply and fixing as in repair of multistranded copper conductor of size 16 Sqmm of any coloured complete all as specified and as directed.
S&F in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with single pole MCB 6 to 32 Amps complete all as specified and as directed
Taking down old unserviceable aluminium sub main wiring any size complete with PVC conduit/ casing capping and removing materials from site and making good disturbed surfaces of walls, etc complete all as specified and as directed by Engineer-in -charge.
M&L Sub main wiring with 4 runs of 6 Sqmm single core, PVC insulated, unsheathed 1100 Volts grade, multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping / Conduit with fitting/accessories, fixed on, walls, ceiling etc. as required including 6 Sqmm PVC insulated, unsheathed, multistranded, copper conductor, single core cable as earth continuity wire complete all as specified and as directed by Engineer-in -charge. Note : four runs of cables and one run of earth wire along with one run of PVC casing capping shall be measured as one run length.
M&L Sub main wiring with 4 runs of 10 Sqmm single core, PVC insulated, unsheathed 1100 Volts grade, multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping / Conduit with fitting/accessories, fixed on, walls, ceiling etc. as required including 10 Sqmm PVC insulated, unsheathed, multistranded, copper conductor, single core cable as earth continuity wire complete all as specified and as directed by Engineer-in -charge. Note : four runs of cables and one run of earth wire along with one run of PVC casing capping shall be measured as one run length.
M&L Sub main wiring with 2 runs of 6 Sqmm single core, PVC insulated, unsheathed 1100 Volts grade, multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping / Conduit with fitting/accessories, fixed on, walls, ceiling etc. as required including 6 Sqmm PVC insulated, unsheathed, multistranded, copper conductor, single core cable as earth continuity wire complete all as specified and as directed by Engineer-in -charge. Note : two runs of cables and one run of earth wire along with one run of PVC casing capping shall be measured as one run length.
S&F Sub main wiring with 2 runs of single core, 4 Sqmm PVC insulated, unsheathed, 1100 volts grade multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping / Conduit with fitting/accessories, fixed on roof, walls, ceiling etc including 4.00 Sqmm PVC insulated, unsheathed, single core, multistranded,, copper conductor as earth continuity wire complete all as specified and as directed by Engineer-in -charge. Note : two runs of cables and one run of earth wire along with one run of PVC casing capping shall be measured as one run length.
S&F in repairs 15 W recess type LED decorative ultra slim Square lighting fixture with co extruded polycarbonate body, environmental friendly, energy efficient and making connections with twin twisted unsheathed PVC copper cable of suitable size complete as specified and directed.
Supply and fixing as in repair of mounted energy efficient recess / Ceiling mounted 40 W LED luminari suitable for 2'x2' grid with profiled diffuser including lamp,electronic control driver 40 watts, AC 230 Volts 50 Hz downlighter with white powder coated aluminium housing withh integrated electronic driver of existing place complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of thermal type of MCCB TP 16 KA 160 Amps complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of MCCB TPN/FP of capacity of 63- 160 Amps complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of copper lugs 2.5 Sqmm complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of copper lugs 4 Sqmm complete all as specified and as directed by Engineer-in-Charge.
M&Lin repair of sheet metal board complete with locking arrangement, fabricated cubical shape out of 2.00 mm thick MS sheet flushed in wall including mounting arrangements for energy meters and one MCB TPN DB /MCCB TPN DB 4 way, front opening, painting with two coats of synthetic enamel paint over a coat of red oxide primer on internal and external surfaces and making good damaged surface complete including taking down old unserviceable rusted sheet metal enclosure, from the building and complete all as specified and as directed by Engineer-in -charge. Note:- 1. Size will decided as per site requirement. 2. Dismental all energy Meter (6-8 Nos) and MCCB TPN/MCB TPN DBs(1/2 Nos) and kept in safe courstoudy and refixing the same day after fixing the metal board. 3.Concealed the DBs on wall all including make in good and matching with existing surface
M&L for Welding of two MS/GI Sheet / Pipes on site including grinding the welded portion and made smooth surface complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of PVC casing capping medium grade of size 25 mm on wall /roof with help of screw including serviceable copper /alluminium conductor and all fitting fixture such as Tee, Elbow and lapping complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of PVC casing capping medium grade of size 32 mm on wall /roof with help of screw including serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of PVC conduit medium grade of size 20 mm on wall /roof with help of screw and GI saddle including fixing of existing serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of PVC conduit medium grade of size 25 mm on wall /roof with help of screw and GI saddle including fixing of existing serviceable copper /alluminium conductor and all fitting fixture such as tee, elbow and lapping complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of PVC Flexible conduit of size 25 mm complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of PVC Flexible conduit of size 20 mm complete all as specified and as directed by Engineer-in -charge.
Material and labour PCC (1:3:6) type C-2 Nominal mix (using 40 mm graded broken stone aggregate) as in coping/collar of poles including necessary form work complete all as specified and as directed by Engineer-in -charge.
Taking down carefully defective street/security light fittings of any wattage any make from street light pole and re-fixing the light fittings in original position after replacement of LED driver including necessary checking of connection and removing the oxidization from connection as required complete all as specified and as directed by Engineer-in -charge.
Supply only electronic LED Driver 150W Including testing complete al as directed by engr-in charge
Supply only electronic LED Driver 90/72 W Including testing complete al as directed by engr-in charge
Supply only electronic LED Driver 36/40 W Including testing complete al as directed by engr-in charge
Supply only electronic LED Driver 24/25 W Including testing complete al as directed by engr-in charge
Taking down carefully defective flood light fittings of any wattage any make from shade /powerhouse building / Main Gate and re-fixing the light fittings in original position after replacement of LED driver including necessary checking of connection and removing the oxidization from connection as required complete all as specified and directed by Engineer-in-Charge.
Supply only electronic LED Driver 60/70 W Flood light Including testing complete al as directed by engr-in charge
Supply only electronic LED Driver 120/150W Flood light Including testing complete al as directed by engr-in charge
Supply only electronic LED Driver 200W flood light Including testing complete al as directed by engr-in charge
Taking down carefully defective Gate light fittings of any wattage any make from gate/post and re-fixing the light fittings in original position after replacement of LED driver including necessary checking of connection and removing the oxidization from connection as required complete all as specified and directed by Engineer-in-Charge.
Supply only electronic LED Driver 35/40 W Flood light Including testing complete al as directed by engr-in charge
Taking down carefully defective Bollard light fittings of any wattage any make from garden and re-fixing the light fittings in original position after replacement of driver including necessary checking of connection and removing the oxidization from connection as required complete all as specified and directed by Engineer-in-Charge.
Supply only electronic LED Driver 10/12 W Flood light Including testing complete al as directed by engr-in charge
Supply only electronic LED Driver 18 W Flood light Including testing complete al as directed by engr-in charge
M& L for preparation to internal and external old steel surface of LT Feeder Piller Box/ Panel Boards of various size and completely removal of existing treatment by scraping or chemical and surface painted with DUCO paint with help of spray gun over a coat of red oxide primer complete all as specified and as directed by Engineer-in -charge.
M& L for repair of LT Feeder Piller Box/ Panel Boards made out of 2.00 mm thick mild steel sheet fixed to existing frame and painted with DUCO paint with help of spray gun over a coat of red oxide primer including taking out to existing warn out shutter frame and fixed with minimum two hinghes to existing frame complete all as specified and as directed by Engineer-in -charge.
Taking down of PCC any grade complete all as specified and as directed by Engineer-in-Charge.
M&L Plain cement concrete (1:2:4) of B1 grade with using 20 mm aggregate Nominal mix in foundations filling and mass concrete complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of MCB 40 Amps, TP, 415 volt, breaking capacity 10 KA conforming to IS 13647-II: complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of aluminium cable lugs for fixing of armoured cables in panels complete all as specified and as directed by Engineer-in-Charge for the following sizes of cables complete all as specified and directed :-
Supply and fixing as in repair of Copper cable lugs for fixing of armoured cables in panels complete all as specified and as directed by Engineer-in-Charge and for the following sizes of cables :-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes including taking down old unserviceable cable complete all as specified and as directed. Note : The rates quoted shall include cable lugs,cable glands and jointing kit however necessary earthwork shall be measured and paid under relevant items in this schedule.
4 Core 6 Sqmm
4 Core 10 Sqmm
4 Core 16 Sqmm
3.5 Core 25 Sqmm
Taking down and relaying of serviciable cable of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with stranded aluminum conductor 1100 volts grade, laid in trenches / duct with shaddling / on pole including all necessary fixing arrangement such as lugs, glands end termination etc of size 10 Sqmm to 25 Sq mm Core including earthwork complete all as specified and as directed by Engineer-in-Charge
Taking down of unserviciable old DWC HDPE Pipe of any size and any type complete all as specified and as directed by Engineer-in-Charge
Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 40 mm and inner dia 32 mm polythylene including coupler & Bend with smoooth inernal and profiled external surface for non pressue under ground cable complete all as specified and as directed by Engineer-in-Charge
Relaying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 40 mm and inner dia 32 mm polythylene including coupler & Bend with smoooth inernal and profiled external surface for non pressue under ground cable complete all as specified and as directed by Engineer-in-Charge
Excavation in trenches any type of soil (soft/loose/hard/dense) not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation, pipe, laying of cable etc not exc 10 Sqmtr on plan and not exc 1.5 mtr in depth and getting out complete all as specified and as directed by Engineer-in-Charge
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil all as specified and as directed by Engineer-in -charge.
Removing excavated materials (soil) to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point all as specified and as directed by Engineer-in -charge.
M&L for road cutting, removing of material , returning filling and pcc 1:2:4 for laying of LT UG cable /Galvanised Iron Pipe/Rex Pipe all as specified and as directed by Engineer-in -charge.
M&L for fault finding of LT UG Cable including excavation , returning refilling after rectification of fault with fixing of Straight through joint kit, extra UG Cable and DWC (Double Wall corrugated) HDPE pipe complete all as specified and as directed by Engineer-in -charge. Note:- LT UG Cable, Straight through joint kit and DWC (Double Wall corrugated) HDPE pipe shall be measured and paid separately.
Supply and fixing as in repair of cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 10 to 25 Sqmm 3.5 core as in repairs complete all as specified and as directed by Engineer-in -charge.
M&L for rerouting/aligning the serviciable Power Cable on wall /cable duct of size 10 to 25 Sqmm with shaddleing with aluminium pati with requard size of screw inside cable duct complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of IP 66/ 67 thermoplastic-polycarbonate cable junction box of size 205X255X92 with terminal which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on pole / surface / frame with the help of GI calmp of size 25X3 mm ,one no of MCB SP 6 Amp and four way 32 Amp Connector complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of IP 66/ 67 thermoplastic-polycarbonate cable junction box of size 130X180X77 with terminal which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on pole / surface / frame with the help of GI calmp of size 25X3 mm , four way 32 Amp Connector complete all as specified and as directed by Engineer-in -charge.
Supply & fixing IP 66/ 67 thermoplastic-polycarbonate cable junction box of size 255X355X122 MM with terminal which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on pole / surface / frame with the help of GI calmp of size 25X3 mm , four way 32 Amp Connector complete all as specified and as directed by Engineer-in -charge.
Material and labour for Painting to Steel tubular poles 7/9 m long with two coat of Synthetic enamel paint black/yellow combination Zebra marking up to 1 m from ground level / coping & remaining portion painting with one coat of aluminium paint including preparation of old painted surfaces and painting the pole terminal etc. and numbering of pole with PVC printed round PVC sheet containing one letter and 1-3 numbers and fixing with two nos of self dril GI Screw to pole complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of GI tubular swaged poles complete with GI base plate finial taper plug, bolts, nuts and screws,with two holes for drawing conductor between pole box to street light fitting all as specified type 410 SP-31 of height 9m including necessary Earth work,PCC foundation coping etc and refixing of all existing fitting fixtures from old electric pole complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of 2.5 Sq.mm (nominal area) PVC unsheathed multi strandard copper conductor PVC insulated 1100 volt FRLSH grade four core cable drawn through CPVC Pipe not less than 20 mm dia for connecting the street light fittings with required size GI Clamp for holding of CPVC Pipe complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of GI bracket for street lights made out of medium grade GI pipe 40mm dia, 1.5 mtr long bend to shape as directed, fixed on poles with two Nos GI clamp of size 40 x 6mm flat iron suitable for steel tubular pole including suitable GI nuts and bolts washers complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of energy efficient street light luminaire LED type 90 watts,IP66 ,230volts, 50 Hz , in Deepdrawn aluminium housing and cast aluminium pipe mounting attachment including suitable heavy duty electronic driver also driver should withstand 265 volts,and complete accessories, pre-wired and connection complete with suitable size of stranded copper flexible conductor complete all as specified and as directed by Engineer-in -charge.
S&F in repairs energy efficient solar street light all in one with lithium battery LED type of 30 watts, IP 65 in built motion sensor colour temp 6500, 125 lumen/watt complete all as specified and as directed
Supply and fixing as in repair of energy efficient street light luminaire LED type 72 watts,IP66 ,230volts, 50 Hz , in Deep drawn aluminium housing and cast aluminium pipe mounting attachment including suitable heavy duty electronic driver also driver should withstand 265 volts,and complete accessories, pre-wired and connection complete with suitable size of stranded copper flexible conductorcomplete all as specified and as directed by Engineer-in -charge.
Taking out old unserviceable Service wire and supply and fixing Service wire Al Conductor Weather Proof 6 Sqmm 2core complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of Service wire Al Conductor Weather Proof 10 Sqmm 2core complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of LED 35 watt Post top energy saving environmental friendly ,design with symmetrical light distribution,spun aluminium landscape luminair made in cast aluminium spigot housing and IP 65 Protection complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of LED 10 Watt Bollard light made in cast aluminium spigot housing withdecorativecleare opal arcylicdiffuser and IP 65 protection complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of of LED 40 watt Post top energy saving environmental friendly ,design with symmetrical light distribution,cleare landscape luminair(CDL) made in cast alluminium spigot housing and IP 65 Protection complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of Danger notice plate of PVC sheet , printed with letters, figures ( English, Hindi,Tamil) and conventional skull and bones in signal red colour and fixed with GI. clamps, bolts and nuts of approved size, for LT/HT, of suitable size complete all as specified and as directed by Engineer-in -charge.
M&L for earthing complete with Galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mir deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanized earth strip 32x6 mm size connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 40 mm dia GI pipe medium grade for protection of G1 earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type CI chamber. MS funnel, wire gauge. 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos. 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I. Note: (i) Cost of GI earth wire and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returninng & filling, PCC chamber pit, RCC cover & test point. (iii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit.
Supply and fixing as in repair of LED 50 watt flood light energy saving environmental friendly ,design with symmetrical light distribution, luminaire efficiency of 125 lumen/watt and IP 66 Protection complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of LED 80 watt flood light energy saving environmental friendly ,design with symmetrical light distribution, luminaire efficiency of 125 lumen/watt and IP 66 Protection complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of LED 100 watt flood light energy saving environmental friendly ,design with symmetrical light distribution, luminaire efficiency of 125 lumen/watt and IP 66 Protection complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of LED 150 watt flood light energy saving environmental friendly ,design with symmetrical light distribution, luminaire efficiency of 125 lumen/watt and IP 66 Protection complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of LED 200 watt flood light energy saving environmental friendly ,design with symmetrical light distribution, luminaire efficiency of 125 lumen/watt and IP 66 Protection complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of LED 250 watt flood light energy saving environmental friendly ,design with symmetrical light distribution, luminaire efficiency of 125 lumen/watt and IP 66 Protection complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of Digital Timer with Analog time ,contactor pre wired Distribution Board complete time lite 40A 3 Pole 415 V complete complete all as specified and as directed by Engineer-in -charge.
Cutting vegetation and surface dressing not exceeding 15 cm deep including removing the materials to a distance not-exc 60 mtr complete all as specified and directed by Engineer-in -charge.
Supply and fixing as in repair of Surge Protection device of 5 KV in junction box complete all as specified and as directed by Engineer-in -charge.
M&L for wiring of unserviciable timer panel box complete and replacement of existing size of copper wire and copper lugs ,refixing the Digital Timer ,contractor ,connecter and testing complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of power contactors of capacity 40 A 3 Pole 415 V with 2NO+2NC complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of NO/NC of capacity 40A of 415 V complete all as specified and as directed by Engineer-in -charge.
DHAKSHNA MOORTHY AND SON
Chandra Construction Enterprises
Ravi Enterprises
M/s Power Engineering Co
M/s Sriya Enterprises
PTech Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .