Executive Engineer
Executive Engineer PD1 PWD BandR Branch Sirsa
ANNUAL REPAIR OF BUILDING OF GOVT. COLLEGE WOMEN (NON-RESIDENTIAL) AT SIRSA IN SIRSA DISTT.
2020_HRY_147574_1
ANNUAL REPAIR OF BUILDING OF GOVT. COLLEGE WOMEN (
Open Tender
Civil Works - Buildings
Item Wise
30 days
Sirsa
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
Executive Engineer PD1 PWD BandR Branch Sirsa
₹4,000
Yes
3 Jun 2021
13 Oct 2020
20 Oct 2020
13 Oct 2020
19 Oct 2020
13 Oct 2020
Amount
Civil work
Stripping and stacking slates or tiles of roof (HSR. 8.10)
Removing door and windows (wood and steel) with chowkats by making recesses in walls when the wall is not to be dismatlled (HSR 8.18-a,b,c) a) Door
b) Window
c) Ventilator
Dismantling cement conglomerate/terrazzo-floors 25 mm to 50 mm thick including concrete base (HSR 8.25)
Scraping of Cement plaster (HSR 8.32 c)
Tile terracing with one layer of tiles, 22.86 cm X 11.43 cm X 3.81 cm laid dry over a layer of mud mortar including grouting with cement sand mortar 1: 3 and top surface to be left clean. (HSR 13.14)
Top Khurra 0.6 m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. (HSR. 13.50)
Bottom khurra on ground 1.2mx0.6m consisting of brick on edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12mm thick cement plaster 1:3 (HSR 13.57)
Cement cocnrete 1:2:4 gola 10cm x 10 cm quadrant along junction of roof with parapet wall finished smooth, where specially specified. (Ch. 13.64)
Pdg.and fixing PVC rain water pipe 6 Kg. pressure of finolex or Prince ISI mark in cement mortar during masonary work. (a) 100 mm dia( HSR.13.89-a)
Providing and fixing PVC band ISI mark (a)100mm dia PVC Band.( HSR. 13.90-a)
Providing and Laying avg. 6mm thick POP coating on walls, Ceiling beams and linte;s etc complete in all respect as approved by the Engineer-in-charge(HSR. 13.94)
Conglomerate floor 40 mm thick cement concrete topping 1:2:4 (HSR 14.9)
Providing & Fixing vitrified tiles of size 600mmx600mm of approved make in skirting or Dado in any pattern as specified over base of 12 mm thick cement coarse sand morter 1:3 and jointed with white cement slurry mixed with pigment to match the shade of tiles. Note:- tile shall be of premium quality( 1st quality) of reputed manufacturar like NITCO, KAJARIA,SOMANI, ORIENT, JOHNSONS & RAK.( HSR.14.90)
Providing and fixing ceramic tiles/anti skid tiles of size 400mmx400mm or above size approved make in flooring, laid in any pattern as specified over base of 20mm thick cement coarse sand morter 1:3 and jointed with white cement slurry mixed with pigment to match the shade of tiles. Note:- tile shall be of premium quality( 1st quality) of reputed manufacturer like NITCO, KAJARIA,SOMANI, ORIENT&JOHNSONS.(HSR.14.91)
Kotah stone 20 mm thick in skirting risers of steps, dados and wall facing (lining) and pillars laid on 12 mm thick cement coarse sand plaster 1:3 laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone including rubbing and polishing including labour for fixing cramps, dowels and pins etc. (HSR 14.66). Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material.
15mm thick cement plaster 1:6 on the rough side of single or half brick wall. (Ch. 15.12)
12 mm thick cement plaster 1:4 (HSR 15.5)
12 mm thick cement plaster 1:6 (HSR 15.7)
10 mm thick cement plaster 1:4 (HSR 15.52)
Cement pointing 1:2 deep variety on brick and tile work. (HSR 15.60)
Cement pointing 1:2 flush on brick and tile walls (HSR.15.62)
Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including the surface to required finish complete (HSR. 16.1)
Applying pink primer or aluminum priming coat on wood work including preparation of surface, knotting and stopping etc. (HSR. 16.2)
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered of concrete surfaces to give an even shade.( HSR. 16.3)
Painting one coat with synthetic enamel paint in all shades on old wood-work or metallic or plastered or concrete surfaces to give an even shade including rubbing down old paint. (HSR 16.7)
Applying priming coat with cement primer in all shades on newly plastered or concrete exterior surface. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.25).
Painting two coats with ready-mixed exterior paint in all shades on newly plastered or concrete surface of walls. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.26).
Varnishing and Oiling Oiling wood work with raw linseed oil.(HSR 16.40)
White Washing one coat or subsequent coat. (HSR 16.46)
Colour Washing One coat or subsequent coat (HSR 16.49)
Distempering with dry distemper (of approved manufacture) one coat on old distempered work. (HSR 16.55)
Providing two coats of exterior acrylic emulsion paint. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). [HSR 16.79 (b)].
Supplying and fixing glass panes with moulding of commercial hard wood such as hollock, champ, chikrassy and chaplash etc.(Non coniferous timber other than teak, conforming to I.S. specification No.1003, kiln seasoned). B) 3 mm thick (glazing area above 9 sq dm, but upto 55 sq dm of each pane) (HSR 17.36 b)
Factory manufactured soild flush door shutters, with block board core as per I.S. No. 1659-1969 bonded with water proof type phenol formaldehyde synthetic resin, hot-pressed, conforming to I.S. 2202 part I and II, fixed in position, including iron hinges, screw, chocks/cleats and stops, etc. (excluding the cost of any fittings other than specified above, but including labour for fixing the same in position) (a)commercial veneering with vertical grains or cross bands and face veneer on both sides comercial facing with laminated core and lipped edges.(HSR. 17.93(a-ii, iii) (-) Note 17.18 (ii) 30 mm thick
(iii) 35 mm thick
Supplying and fixing glass panes including special metal sash putty of approved make b) glass panes 4 mm thick, exceeding 40 sqm areas. (HSR 18.30 b)
Pressed steel sheet frames (chowkats), consisting of 2mm thick steel sheet of the specified section, including iron lugs (hold fasts), iron hinges, conforming to P.W.D. specifications, including bolts for fixing stops, locknotch, provision for receiving tower bolts, and finished with one coat of ready mixed paint red lead non setting primer, of approved quality, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame, and cement concrete 1:3:6 for lugs complete :-( HSR. 18.34 -a,c) a) door and window frame of size 89 mm x50 mm with 40mm wide single rebate
c) door and window frame size 127 mm x50 mm with 40mm wide double rebate
(PHA Work) :- Providing and fixing in position best indian make (as approved by the engineer-in-charge) European type water closet suite, syphonic type consisting of- (i) VITREOUS CHINAWARE SYPHONIC SUITE WITH 15 LITRES CAPACITY MATCHING CHINAWARE CISTERN and all internal brass fittings COMPLETE WITH ‘P’ or ‘S’ TRAP with or without vent; (as approved by the Engineer-in-charge). (ii) One piece SEAT AND LID IN HOLLOW BLACK OR WHITE PLASTIC fitted with chromium plated hinges and rubber buffers, (to the approval of the Engineer-in-charge) COMPLETE in all respects INCLUDING CUTTING AND MAKING GOOD THE WALLS AND FLOORS. (a) single trap syphonic W.C. Suite (i) White [HSR 30.5 (a) (i)].
Providing and fixing in position best indian make (ordinary) lavatory suites consisting of lavatory in vitreous chinaware size as given below (to the approvalof the Engineer-in-charge) including china plug for tap hole where necessary; RS or C.I Brackets for building into wall including painting; 32 mm C.P. Brass waste with C.P. brass chain and rubber plug; 15 mm C.P. Brass screw down piller tap with jamnuts or couplings best design (as approved by the Engineer-in-charge) All fittings Best Indian make and; to the approval of the Engineer-in-charge. All brass work chromium plated and complete in all respects including cutting and making good the walls, floors and Painting of fittings etc.White (IV) -size 550 mm x 400mm with one no tap (HSR. 30.41-white-iv)
Providing and fixing in position best Indian make Soap dish fixed into wall with C.P. brass screws and complete in all respects including cutting and making goods the walls etc. (a) C.P. Brass (i) Soap dish Large. [HSR 30.70 (a) (i)].
Providing and fixing in position 15mm i/d C.P. brass bib cocks of best quality (as required by the engineer-in- charge) bib cock (HSR 30.75- c)
Providing & Fixing of G.I. Pipes 15 mm internal dia (NS)
Providing & Fixing of G.I. Pipes 25 mm internal dia (NS)
Atul Gupta Contractor
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .