Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 bidder | |
| 2 | L2₹8.2 L+₹14,670 (1.82%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical Rejected due to non available of BCA clearance certificate |
Tender Value
₹8.3 L
EMD Value
₹16,550
Closing Date
21 Jan 2022, 6:00 pmClosed
Shri Avinash Mishra IDSE GE
Garrison Engineer (I) (CG) Bhubaneswar, Plot No 190/702, Kokila Residency, 2nd Floor, Anant Vihar, Post-Pokhariput, Bhubaneswar- 751020
MAINTENANCE AND OPERATION OF LIFT THROUGH OEMS JOHNSON ACCREDITED AGENCIES
2021_MES_475212_3
8256/BBSR/04/E8
Open Tender
Miscellaneous Works
Item Rate
335 days
Bhubaneswar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (I) (CG) Bhubaneswar
₹16,550
Yes
31 Jan 2022
31 Dec 2021
24 Jan 2022
31 Dec 2021
21 Jan 2022
7 Jan 2022
31 Dec 2021 - 5 Jan 2022
Amount
Maintenance and Operation of lift No G9691 through AMC under repair, replacement, Overhaulling, Maintenance of Lifts through OEMs (Jonson) / accredited Agencies installed at Hanger of capacity 13 passengers including necessary minor repair / replacement of defective parts work if required in any emergency and kept the the lift in working condition at round the clock complete all as specified and directed.
Maintenance and Operation of lift No G9692 through AMC under repair, replacement, Overhaulling, Maintenance of Lifts No 02 through OEMs (Jonson) / accredited Agencies installed at Hanger of capacity 13 passengers including necessary minor repair / replacement of defective parts work if required in any emergency and kept the the lift in working condition at round the clock complete all as specified and directed.
NOTES FOR ITEM NO 1.00 & 2.00 :- 1. Service the lifts at regular intervals and as frequently as the company deems necessary based on the age, nature and condition of the elvator and will take all responsible care and maintain the lift equipment in safe and proper working condition. 2. Carry out the services work whenever possible on day convenient to the customer other than sunday and holiday and during regular working hours. 3. Depute an entitled authorised service personnel to attend all call backs during normal working hours and also if any emergency even after working hours. 4. Replenish the gear and motor bearing with necessary Johnson/authorised lubricants whenever necessary including checking /cleaning of all moving parts and keep them both electrically and mechanically in perfect working condition . 5. Checking of minimum/maximum oil levels of gear, motor and guide lubricant tank complete all as directed. 6. Lubrication of motor bearing , brake pivets , weel bearing , mechanical limit switches, gate rollers and tracks, safety gear mechanisum, lock and rollers, connecting wires , retiring ram etc complete all as directed. 7. The rate quoted is deemed to be inclusive to tools and safety equipment, CRC SPARY, minor consumables such as PVC insulation tape, screws, fuse wire, clips,freuuel,locks,First Aid Box required for running and maintenance of plants
NOTES FOR ITEM NO 1.00 & 2.00 (Contd):- 8. Inspection of electrical system such as main switch, over load protection, control relays , connecting wires, single phase preventor, main and lighting fuses, contact allingments etc all as directed. 9. Checking and inspection of motor terminals, brake liners, coupling bushes, limit switches, ultimate limit switch magnetic switches , push button movements, brake shoes, noice level, working condition of LEDs, gate lock, spindle movement, condition of lock brake condition of rubber roller , mechanicl lock plate , rope anchorages, tightness of rope clips, position of equaliser , trailing of cables, condition of cable , door allingment clearance between vain and rollers, all mechanisum bolts, , door bearings, floor anounciator working condition, door skate, conditon of door switches, safety edges etc complete all as directed. 10. Checking of all emergency devices such as ARD working condition, Battery condition, over load device working condition, over load anounciator and display condition, emergency ligh working condition, emergency siren alaram condition , charing unit condition etc.complete all as directed. 11. Checking of lift well lighting, machine room lighting, machine room ventilators , machine room door including cleaning of machine room, lift well, enclosure, landing gates, car gates, car inside, lift pit etc 12. Ist inspection and service charges shall be paid by the contractor.
NOTES FOR ITEM NO 1.00 & 2.00 (Contd):- 13.Checking the following devices :- (a) Breake releasing mechanisum working condition (b) Break lock nut measurement in mm (c) Break arm switch (d) Emergency battaery condition (e) Trap door access condition. (f) Breake plunger lock nut tightness (g) Additional car gate lock contact (h) Controller light working condition (j) Press and speek working condition (k) Shaft controller wiring tightness (l) Oil buffer working condition and oil level (m) Any abnormal noise obseerved. (n) Carryout the load testing ones in a year (o) Regularly Checking of ARD System (p) Consequence checking of fault electrical System. (q) Consequence checking of Earthing System. 14. The passes required to enter in to Airport area for carry out AMC of lift shall deemed to be arranged by contractor at his own.
Supply only following Spare parts for Lift No L-G9692 (MMMA):- (a) SP2 floor announciator 24 V DC - Nos - 01 (b) SP2 286 Orange DOT matrix without gong - Nos - 01 (c) Speaker for floor announcitor in wooden - Nos - 01 enclosure, 4inch (ML electronics) (d) Power door contact female - Nos - 02 (e) Emergency light lamp board LED type - Nos - 01 (high bright 15 Nos LED) (f) Push button BAS 128 Braille (No 4 Orange ) - Nos - 06 (g) Push button BAS 128 Braville (3 Orange) -Nos - 01 (h) Charger unit - Nos - 01 (j) Bearing Oil -Ltrs - 02 (k) Extension display for SP2 to display fault, - Nos - 01 input and outputs
Supply only following Spare parts for Lift No L-G9691 (Tech Bldg) :- (a) Charger Unit - Nos - 01 (b) Push button BAS 128 Braille (0 Orange) - Nos - 01 (c) Push button BAS 128 Braille (2 Orange ) - Nos - 01 (d) Bearing Oil - Nos - 02 (e) Push button BAS 128 Braille (DN button Orange) - Nos - 03 (f) Extension display for SP2 to display fault, input and outputs - Nos - 01 (g) Door spring C.O. - 800 MM - Nos - 02 (h) FSR & Main limit switch Assy NC type 1058/2138 - Nos - 01 (j) MLS mounting adaptor bracket to suit schmersal limit switch - Nos - 03
Supply only following Spare parts for Lift No L-G9691 (Tech Bldg) :- (a) Single phase preventer with two changf over - Nos - 01 contacts (for SP2 (b) Logic board for ( C) ARD 25 Pin - Nos - 01 (c) SP2 mother board with finder relay and FCI connector - Nos - 01 (d) SP2 Car board with finder relay and FCI connector - Nos - 01
Supply and fixing in repairs of ARD system battery complete all as specified and directed.
Supply and fixing in repairs of cross thaw lift cabin fan complete all as specified and directed.
Supply and fixing in repairs of over load relay 6 A complete for water cooler 40/80 Ltrs complete all as specified and directed.
Supply and fixing in repairs of thermostate 6 A suitable for water cooler 40/80 Ltrs complete all as specified and directed.
Supply and fixing in repairs of capacitor 10 MFD suitable for water cooler 40/80 Ltrs complete all as specified and directed.
Supply and fixing in repairs of flexible PVC water drain pipe 40 mm dia 2 mtrs long complete all as specified and directed.
Supply and fixing in repairs of push type water tap CP suitable for water cooler 40/80 Ltrs complete all as specified and directed.
Supply and fixing in repairs of plug top three pin 15 Amp complete all as specified and directed.
Supply and charging refrigerant gas R-134A up to required level including cleaning testing of leakage or pressure test etc suitable for water cooler 40/80 Ltrs complete all as specified and directed.
Supply and fixing in repairs of PVC 25mm dia for connecting of all AC drain pipe with all fittings & making of all connection complete all as specified and directed.
Repair of Voltage stabilizer of 5 KVA capacity complete all as specified and directed.
Repair of Voltage stabilizer of 4 KVA capacity complete all as specified and directed.
Repair of Voltage stabilizer of 2 KVA capacity complete all as specified and directed.
Supply and fixing in repairs of flat copper cable 2.5 sqmm 3/4 core for water cooler 40/80 Ltrs complete all as specified and directed.
Material & labour for inspection of Hangar door (4 Nos) installed at CGRA Bhubaneswar located at inside Airport Monthly basis & as and when required for continuous operation of Hangar door. Inspection of Hangar doors includes, checking of door operation, cleaning of rails using wire brush at bottom & upper side, greasing of gear driven by motor, tightening of bolts & nuts, checking of control panel etc. The quoted rate deemed to be inclusive of repair/replacement of any parts required for continuous operation of Hangar door (04 Nos), change of wire, contacts, gear keys winding of motor, change of limit switches etc. complete all as specified and directed.
Servicing of AC of any capacity including checking of filter units, condensor, relays & Compressor etc. including minor repair complete all as specified and directed.
UNITED TECHNOCRATS AND BUSINESS INTELLIGENCE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .