Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.5 CrAccepted-AOC 208 2ND FLOOR EXPRESS MARKET AMBEDKAR ROAD GHAZIABAD 201001 UP | GHAZIABAD | UTTAR PRADESH | 201001 | ₹10.5 Cr | L1 | Accepted-AOC Accepted being L1 bidder. |
| 2 | L2₹14.8 CrRejected-Finance PO KETEKIBARI DISTT SONITPUR TEZPUR ASSAM 784001 | SONITPUR | ASSAM | 784001 | ₹14.8 Cr | L2 | Rejected-Finance Rejected being higher than L1 bidder. |
| 3 | Rejected-Technical | - | - | Rejected-Technical Rejected being the firm is two class below than eligible class as per NIT. |
Tender Value
₹10.3 Cr
EMD Value
₹8.4 L
Closing Date
6 Mar 2020, 6:00 pmClosed
CE (AF) SHILLONG ZONE
HQ CE (AF) SHILLONG ZONE, ELEPHANT FALLS CAMP, PO-NONGLYER, SHILLONG-793009
WORK SERVICES FOR ADDN/ALTN TO EXISTING BLAST PENS AT AFS CHABUA
2019_MES_266743_2
88610/CHAB/E8
Open Tender
Civil Works
365 days
GE AF CHABUA
As per tender documents
7 documents required · 7 mandatory
₹3,000
GE AF CHABUA
₹8.4 L
11 May 2020
30 Dec 2019
12 Mar 2020
31 Dec 2019
6 Mar 2020
31 Jan 2020
31 Dec 2019 - 20 Jan 2020
Amount
SCHEDULE "A" Part - I (BUILDING / STRUCTURE WORK) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 signifies this fact only.
Addn/Altn to existing blast pens complete all as specified and as shown on drawings.
SCHEDULE "A" PART-II (EXCAVATION AND EARTH WORK) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-III (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-V (LIGHTENING ARRESTER ) Details of prepriced Schedule is given in tender documents.
INTERNAL ELECTRIFICATION . S&F air circulation fan, AC single phase, oscilating, 230 V of size 600mm sweep.Make Havells(Model:Turbo Force) or equivalent model of Make: Bajaj/Philips
S&F energy saving 100WLED flood light luminaire,IP66 protection complete all as per cat No.-BJHFL 100W LED of make: Bajaj or equivqlent model of Make: Havells/Phillips including connecting with PVC insulated sheathed round flexible copper conductor of size 0.50sqmm 3core (approx 0.50mtr) 1100Volts grade complete all as specified and directed.
S & F SPN MCB 32 Amps, 10 KA with copper lugs complete all as specified and as directed. Make :- Legrand cat No 408617 or equivalent from list of make specified in PS.
S & F MCB single pole,6 to 32 Amps, 10 KA with copper lugs complete all as specified and as directed. Make :- Legrand cat No 408587 to 408595 or equivalent from list of make specified in PS.
S&F double door distribution board, TPN, 4 way, 415 volts with provision for DPX 63 to 160 MCCB as incommer and SP/TP MCB as outgoing and electrically connecting up complete all as specified and directed. Make:Cat No. 6079 13 of LEGRAND equivalant make of L&T/Schneider
EXTERNAL ELECTRIFICATION. S & F of street light fitting, 45 watt LED streetlight made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP66 protectioncomplete all as per cat no LHETAXU7PN6J045 of Make : Havells or equivalent mode ofMake :Bajaj/CG
Supply and fix street light bracket,bend to 120 degree angle, made out of 40 mm bore, galvanised iron, light grade tubing (approx 1.20 mtr in length ) including necessary two nos suitable size of clamps with nuts, bolts and washers, etc and two coats of synthetic enameled paint over a coat of red oxide primer including taking down the old unserviceable one complete all as specified and directed.
S&F Cable Junction Box 200x160x98mm in size, made out of thermoplastic sheet having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32-3 nos) fixed on poles with flat aluminium clamps of size 20x3mm, nuts bolts, washers etc. including taking out of old unservicable cable junction box complete all as specified and asdirected Make : Cat No K-9105 of HENSEL or equivalent mode in SPELSBERG/RITTAL
Boring of holes under road, pavement, hard standing by tranchless technology including HDPE pipe of 150 mm dia dia suitable fore 0.4 mpa working pressure all as directed and specified.
Supply, Install, testing and commissioning of self supporting totally enclosed LT out door typefeeder pillar box compartmentalised desin,double door, dust and verminproof of suitable for 440volts 3 phase 4 wire system made out of 3 mm thick CRCA Sheet and built upon rigid frame work having front and rear hinged door with neopren rubber gasket including danger plate,earth strip point and ventilation louvers at the rear side, bottom detachableglandplate complete withzinc/ chromium plate nuts, bolts, washers, etc. The pannel shall be epoxy powder coateda and connection with aluminiumbus bar bent toshape, incoming / out going cable connection holes at the bottom. The normal ground level comlete with PCC foundation (1:2:4) type B2 complete all as specified and directed. The size 1000 mm x 1000 mm x 600 mm and comprising following:- Bus Bar (a) Electrolytic grade high conductivity TP&N soil copper bus bar, rated 200 amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - 04 nos CONTROLS (a) Supplyand fixing MCCB of 4 pole of capacity 100 amps, with breaking capacity of 25 KV with adjustable thermal and adjustable magnetic - 01 Nos (Incomming) (b) Supply and fixing MCCB of 4 pole of capacity 63 amps, with breaking capacity of 16 KA with adjustable thermal and adjustable magnetic -02 nos (c) Supply and fix MCB, SPN 32 Amps -10 KA -02 No (d) Supply and fixing LED IndicatingLampsforMain Supply indicatingR, Y, B-03 Nos (e) S&F Timeswitch with contractor 20 AMPS -01No
M&L for earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanised iron or steel earth lead of GI strip 25X4 mm by means of welding bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No-3 SSR Part -1 2009 including earth strip protected by Galvanised pipe of dia 32 mm (light grade) and connected to main switch board or main control panel (upto 7.50mtr), excavation and earth work, disposal of surplus spoil and provn of RCC (1:2:4) cover 50 mm thick reinforced with 8mm dia TMT deformed bars 100mm c/c both ways incl one handle made of 12mm dia MS bars of lenth 500mm with wiremesh, and PCC (1:3:6) type C-2 concrete pit and watering pipe 20 mm bore GI (light grade) testing on completion incl providing charcoal or coke and common salt in alternate layer of 15 cm compacted thickness all around the earth electrode including demolition of existing unserviceable earthing complete all as specified & directed.
LIGHTING ARRESTER. . M&L for testing and Earthing complete with copper plate electrode of size 60cm×60cm×3.10mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to copper earth strip 25 mm x 3 mm by means of bolts, nuts, check nuts and washers of brass or HS steel all as shown in electrical plate No. 3 connected to earthing test point and and necessary excavation and earth work PCC (1:3:6) type C-1 with suitable size of pre cast RCC(1:2:4) type B1 cover slab 400x400x50mm with one handle for lifting made out of 8mm dia MS bar, incl providing charcoal or coke and common salt in alternate layer of 15 cm compacted thickness all around the earth electrode with funnel and 20 mm bore galvanized iron watering pipe (medium grade), wire mesh, copper lugs, complete in all respect, protected by 40 mm bore (light grade) galvanized iron pipe up to earthing test point as directed, incl disposal of spoil to a distance not exc 50 mtr and necessary testing on completion complete all as specified and as directed. Note :- Earth strip beyond 7.5 mtr shall be measured and paid separately.
VARNI BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid