Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹67.9 LAccepted-AOC | L1 | Accepted-AOC Qualified | |
| 2 | L2₹66.6 L+₹6.7 L (11.1%)Rejected-Finance | L2 | Rejected-Finance High Amount Quoted |
Tender Value
₹73.5 L
EMD Value
₹3.7 L
Closing Date
2 May 2022, 2:30 pmClosed
Excutive Engineer
GDA Office, Taramandal. Gorakhpur
Please refer Tender documents.
2022_GORDA_691550_17
02/GDA/2022-23/16042022
Open Limited
Electrical Works
Fixed-rate
90 days
Gorakhpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,800
₹3.7 L
3 Jun 2022
27 Apr 2022
2 May 2022
27 Apr 2022
2 May 2022
27 Apr 2022
27 Apr 2022 - 2 May 2022
Amount
S/F of double pole structure with S.T. pole designated to 410 SP-71, 13 M long including the cost of channel stay 4 no.,disc,pininsulator , pole, excavation ,erection,groutting, plinth & painting etc. complete in all respect work as per dorection of E/I & as per norms of U.P.P.C.L. PSR
Construction of four pole structure with S.T. pole designated to 410 SP-71, 13 M long including the cost of channels disc & fittings, pin & insulators, stay, pole, excavation work, plinth & painting etc. complete in all respect work as per dorection of E/I & as per norms of U.P.P.C.L.
Painting of S.T. pole SP-71-13.0 mtr. long including painting of X-arms Guarding channel clamps etc. with two coats of synthetic enamal paint/ Al paint over one coat of ready mix primer (from top to channel red paint & channel to ground Al. paint including cost of all materials as well as rubbing & cleanig of surface as required for proper completion of work as per direction of E/I PSR
S/E of Stay set at least 3.5 mtr. Away from the pole complete with galvanised 19mm. dia. & 1.80 long stay rod 30X30cm.x0.63cm. Anchor plate thimble stay clamp, stay insulator, 19x600 mm., double screw tighter, 7/3.15 mm G.I. stay wire in 1:3:6 cement complete in all respect SIN-631.
Earthing of O/H/ line pole with 2.5 mt. long 20 mm dia G.I. rod including the cost of 7/16 S.W.G. G.I. earth wire labour & T&P etc. required for proper completion of work as per dorection of E/I PSR
S/F of 33 KV pin insulator with pin on steel pole or any where specified including bolts to fasten the pole cap/cross arm with the pole for proper completion of work as per direction of E/I. PSR
S/F of P.G. clamp/turn buckle as per specification of U.P.P.C.L. PSR
Supply and laying of 3 core standered aluminium conductor 300 sqmm XLPE (cross linked polyethylene ) insulated PVC bedded galvanised flat steel strip armoured cable confirming to I.S 7098 ( part -2 with latest amendments ) 33000 volts grade complete in all respects the armouring of the cable shall be property connected with the earth conductor by clamps with brick sand etc. make asper UPPCL approved( make Polycab & havells ) PSR
S/F of 33 KV 300 sqmm XLPE insulated Cable end joint termination kit heat srink outdoor type M-seal/ Raychem make complete in all respect as per direction of E/I PSR
Excavation in foundaction for cabile trunch work size 1000x800mm (Average) for electrical trench. Or into the plinth and remuval and disposal surples earth as directed by the Engineer incharge with in a leed of 30m from foudaction trenches as per diraction of the E/I. and etc complect work. (A.R.)
S/Fof 6 inch dia GI pipe complete in all respect as per direction of E/I. PSR
Cartage of old materials from site to uppcl store including loading /unloading PSR
Sanjay Kumar Srivastava
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Restricted Tender
This is a Open Limited tender. Documents are accessible only to bidders authorized by the issuing authority on the government portal.
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .