Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.4 L+₹30,796 (3.82%)Rejected-Finance | L2 | Rejected-Finance EMD Rejected |
Tender Value
₹7.8 L
EMD Value
₹16,500
Closing Date
26 Oct 2022, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Atul Bhardwaj
Hauz Khas
Repair and Improvement of EI and Fans in Room No.215-16,217,218 and 219 at 2nd floor, palika bhawan, sector 13 R K Puram, New Delhi for judicial committee.
2022_SDMC_132580_1
EEE/SZ/2022-23/30
Open Tender
Electrical Works
Works
15 days
South Zone
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹16,500
18 Jan 2024
18 Oct 2022
26 Oct 2022
18 Oct 2022
26 Oct 2022
18 Oct 2022
Amount
Laying and Jointing PVC Pipe. Heading
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group C
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.(a)3 x 2.5 sq.mm
6 x 2.5 sq.mm
3 x 4 sq.mm
6 x 4 sq.mm
3 x 6 sq.mm
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(a)5/6 amps switch
3 pin 5/6 A socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.(a)8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
SITC of 10W surface/wall mounted LED Bulkhead factual impact dust and water resistant luminaires with IP 65/66 protection.
Supplying and fixing call bell/ buzzer suitable for single phase,230 V, complete as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole (a) Single Pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 amps
S.I.T.C of LED Tube type Luminaire 20W rating complete with polycorbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following: (a) Total System wattage 20 watt +/- 5% (b) Luminous Efficacy Lumens/watt >=95 (c) power factor >= 0.95
SITC of recess mounting CRCA housing 36 W LED luminaire with acrylic cover diffuser with following specifications including fixing on existing fixing on existing wall/recess with conections as required (a) Total system wattage = 36 watt +/- 5% (b) Luminous efficacy >=95 lumens /watt. (c) Power factor >=.95
Supply of 1200 mm sweep 50 watt, Energy saver ISIS marked BEE 5 star rating AC Ceiling fan suitable for 230 V , 50 Hertz AC supply without regulator with blades, downrod etc. complete as required.
SITC of wall mounted Fan 400mm sweep rated voltage 220-230 AC rated frequency 50Hz speed 1280-1350 rpm with desire color.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Supply and Fixing of 3 mm thick phenolic laminated sheet
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63A
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
Supply of 250 mm ( 10' )sweep 1250 RPM exhaust fan Fresh Air Type complete with shutter,blade etc as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Supply, installation, testing and commissioning of Inverter Split Airconditioner rotary air compressor (R32/R 290/R 410A Refrigerant) 100 % copper condenser , rating 2 ton complete with outer unit as required (5 star rated)
SI/T/C of stand for split AC
SITC of 4 KVA voltage stabilizer having inpur voltage 150 V -270 and output voltage of 195-245 V
SITC of Copper pipe for split AC
SITC of drain pipe
SITC of 3 core , 4 sqmm electrical wire for air conditioner
Supplying & Installation wall mouted RO plus UV plus UF water purifier with upto 20 L/hr purification capacity and storage tank up to 09 litre capacity.
Supplying & Installation Hot Cold & Normal Floor Standing Top Loading Water Dispenser with Cooling Cabinet Fridge cold water storage capacity upto 3.5 ltr with hot water storage capacity upto 1 ltr as required
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
Supplying & Installation of AC 1750 dual band smart wifi Router .
SHRIRAM SHARMA
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .