Lt Col PK Morolia
GE (AFA) Hyderabad, Pin- 500043
PERIODICAL MAINTENANCE OF SEWAGE PUMPING LINES AND SEWAGE INSTALLATIONS AT AFA HYDERABAD
2020_MES_346299_1
8983/02/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AFA) Hyderabad
As per Tender Documents
5 documents required · 5 mandatory
₹500
Yes
GE (AFA) Hyderabad
₹49,800
Yes
7 Oct 2020
20 May 2020
25 Jun 2020
20 May 2020
24 Jun 2020
3 Jun 2020
20 May 2020 - 26 May 2020
60 days
Amount
M&L for Cleaning of Sumps, Chambers etc, by removing sludge, mud, debris and foregin materials by scraping all the surfaces with wire brushes, scrapers, ..etc and removing the sludge, debris, and foregin materials etc to a distance not exceeding 150 mtr away from STP site, cleaning with fresh water (internally) and disinfectant solution complete all as required, including applying of two coats of lime white wash internally complete all as directed by the Engineer-in-Charge for the following capacity :- (New STP)
(a) Under ground Equalization Tank Capacity 157 Cum
(b) Semi under ground Areation Tank Capacity 454.24 Cum
(c) Semi under ground Secondary settling Tank Capacity 114.8 Cum
(d) Semi under ground Clarified water Tank Capacity 82.51 Cum
(e) Sludge Holding Tank Capacity 28.7 Cum
(f) Sludge Drying Bed Capacity 11.17 Cum
(g) Treated water Tank Capacity 224 Cum
M&L for disconnecting the suction and delivery pipe lines and electric connections for Non clog centrifugal pump sets of Sewage Installations of following capacities servicing it throughly and carrying out the repairs such as replacing the worn out bearings at non-drive and drive end of pump shaft/ bushes, gland rope, nuts, bolts, washers, greasing and bringing it to workable condition and connecting up of suction and delivery pipe lines and electric connections incl testing complete all as specified and as directed for the following capacity pump sets :- Note :- (i)The unit rate quoted against the item includes cleaning / repairs, replacement of minor items such as nuts, bolts, gland rope, packing materials etc necessary repairs / replacement of Spares will be measured and paid separately under relevant items of BOQ.
(a) 2 HP, 3 phase 415 volts
(b) 5 HP, 3 phase 415 volts
(c) 10 HP, 3 phase 415 volts
(d) 12.5 HP, 3 phase 415 volts
(e) 20 HP, 3 phase 415 volts
(f) 30 HP, 3 phase 415 volts
Supply only CI / gun metal bushes of suitable size for 2 HP centrifugal pump set complete all as specified and as directed.
Supply only CI / gun metal bushes of suitable size Non Clog centrifugal pump sets complete all as specified and as directed for the following capacity:-
(a) 5 HP, 3 phase, 415 volts
(b) 10 HP, 3 phase, 415 volts
(c) 12.5 HP, 3 phase, 415 volts
(d) 20 HP, 3 phase, 415 volts
(e) 30 HP, 3 phase 415 volts
Supply only CI impeller of suitable size for 2 HP centrifugal pump set complete all as specified and as directed.
Supply only CI impeller of non clog centrifugal pump set complete all as specified and as directed fort he following capacity :-
(a) 5 HP, 3 phase, 415 volts
(b) 10 HP, 3 phase, 415 volts
Material and labour for repairs to impeller of non clog centrifugal pump set of following capacities by metal filling, machining i.e., trurning , milling, grinding etc complete all as specified and directed by Engineer-in-Charge :-
(a) 5 HP, 3 phase, 415 volts
(b) 10 HP, 3 phase, 415 volts
(c) 12.5 HP, 3 phase, 415 volts
(d) 20 HP, 3 phase, 415 volts
(e) 30 HP, 3 phase 415 volts
Material and labour for CI coupling by casting, machining such as turning, milling etc complete to suit to existing 2 HP centrifugal pump set complete all as specified and as directed.
Material and labour for CI coupling by casting, machining such as turning, milling etc complete to suitable for Non clog centrifugal pump set complete all as specified and as directed for the following capacity :-
(a) 5 HP, 3 phase, 415 volts
(b) 10 HP, 3 phase, 415 volts
(c) 12.5 HP, 3 phase, 415 volts
(d) 20 HP, 3 phase, 415 volts
(e) 30 HP, 3 phase 415 volts
Material and labour for repairs to Induction motor of following capacities and removing the same from existing position, transporting the same to the work shop and carrying out the repairs such as taking out the burnt out winding and rewinding the motor with copper wire of same guage turns and weight complete and refixing the same in its existing position after transporting back to the site and connecting up electric connections with suitable lugs complete all as specified and as directed for the following capacity :-
(a) 1 HP, 3 Phase 415 volts
(b) 2 HP, 3phase 415 volts
(c) 5 HP, 3phase 415 volts
(d) 10 HP, 3phase 415 volts
(e) 12.5 HP, 3phase 415 volts
(f) 20 HP, 3phase 415 volts
(g) 30 HP, 3 phase 415 volts
M&L for Repairs / replacement of valve spindle of stainless steel with brass check nut etc for CI sluice valves including valve head gasket, gland packing, new nut bolts, washers etc complete all as specified and as directed for the following sizes :-
(a) 200 mm bore
(b) 150mm bore
(c) 100mm bore
(d) 80mm bore
M&L for Servicing of sluice valves by removing the glands / gate and refix with greasing , new stainless steel nuts, bolts with washers, rubber insertions gland packing etc in situ complete all as specified and as directed for the following sizes :-
(a) 200 mm bore
(b) 150mm bore
(c) 100mm bore
(d) 80mm bore
Dismantling the existing foot valves of 150 / 200 mm cleaning it throughly internally and externally, replacing the gaskets, required nuts, bolts, and washers, greasing and bringing it to workable condition and fixing in location all as required at site complete all as specified and a directed
Material & labour for taking out the debris, plants, shrubs, dead animals etc, from the drying bed size 6100 x 4570 x 1220 mm depth and topping up with required quantity of coarse sand as existing complete all as specified and a directed . Note:- Coarse sand will be measured and paid separately
Supply / filling of coarse sand in sludge Drying beds of sewage Treatment plant for topping up complete all as specified and a directed
M& L for Painting of Non clog centrifugal pump set of following capacity including inlet and outlet CI pipes, non return valves, sluice valves, base plate etc complete with two coats of synthetic enamel paint including cleaning the surfaces complete all as specified and a directed for the following :-
(a) 2 HP, 3 phase 415 volts
(b) 5 HP, 3 phase 415 volts
(c) 10 HP, 3phase 415 volts
(d) 12.5 HP, 3phase 415 volts
(e) 20 HP, 3 phase 415 volts
(f) 30 HP, 3 phase 415 volts
M&L for taking down the unservicable non return valve from position after disconnecting the unserviceable valve supply and fix in repairs non return valve P N 1.6 of size 100mm ISI marked heavy duty with handle including necessary nuts bolts washers and modification etc complete all as specified and a directed
M&L for taking down unservicable sluice valve from position after disconnecting the unserviceable sluice valve supply and fix sluice valve of size 80 mm dia ISI marked PN 1.6 heavy duty with handle including necessary nuts bolts washers and modification etc complete all as specified and a directed
M&L for taking down unservicable sluice valve from position after disconnecting the unserviceable sluice valve supply and fix sluice valve of size 100 mm dia ISI marked PN 1.6 heavy duty with handle including necessary nuts bolts washers and modification etc complete all as specified and a directed
M&L for taking down unservicable sluice valve from position after disconnecting the unserviceable sluice valve supply and fix sluice valve of size 150 mm dia ISI marked PN 1.6 heavy duty with handle including necessary nuts bolts washers and modification etc and making good the disturbed valve chamber earth work etc complete all as specified and a directed
M&L for taking down unservicable sluice valve from position after disconnecting the unserviceable sluice valve supply and fix sluice valve of size 200 mm dia ISI marked PN 1.6 heavy duty with handle including necessary nuts bolts washers and modification etc and making good the disturbed valve chamber earth work etc complete all as specified and a directed
S & F cast iron specials such as bends, collar and tee etc any type of size up to 150 mm bore as per site requirement complete all as specified and as directed by Engineer-in-Charge. Note : -The necessary earth work excavation, lead joints etc will be measured and paid separately.
S & F cast iron specials such as bends, collar and tee etc any type of size up to 200 to 300 mm bore as per site requirement complete all as specified and as directed by Engineer-in-Charge. Note :- The necessary earth work excavation, lead joints etc will be measured and paid separately.
Taking out unserviceable CI pipe of any type and any length including all fittings etc, with spigot and socketed ends and lead joints including burnijng of lead joints from trenches of the following sizes complete all as specified and as directed by the Engineer-in-Charge for the following size :- Note: - The necessary earth work, excavation , will be measured and paid seperately.
(a) 200 mm bore pipe
(b) 150 mm bore pipe
(c) 100 mm bore pipe
(d) 80 mm bore pipe
M & L for cast iron pipe with spigot and socketted ends, centrifugally cast, class LA in any lengths supplied and laid in trenches of the followng sizes complete all as specified and as directed by Engineer-in-Charge or the following size :- Note : The necessary earth work excavation will be measured andpaid seperately.
(a) 200 mm bore pipe
(b) 150 mm bore pipe
(c) 100 mm bore pipe
(d) 80 mm bore pipe
M&L for burning out old lead joint and taking out lead and M&L for new Run lead joints complete all as specified and as directed for the follwoing pipes :- Note:- Earth work and excavation will be measured and paid separately.
(a) 200 mm bore pipe
(b) 150 mm bore pipe
(c) 100 mm bore pipe
(d) 80 mm bore pipe
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr in depth in hard and dense soil and getting out for repairs to water mains / valves / valve chamber including forming bottom surface to required level and gradient complete all as specified and as directed
Returning filling in including spreading, levelling, watering and well ramming, in layers not exceeding 25 cm thick in soil complete all as specified and as directed
Removing the surplus soil not exceeding 50 M and depositing where directed by Engineer-in-charge at a level not exceeding 1.5 Mtr above the starting point complete all as specified and gradient complete all as specified and as directed
S & F in repairs rubber washer set suitable for fire hydrant valve of 63 mm bore complete all as specified and as directed
Disconnecting the suction and delivery pipe lines and electric connections of fire fightng pumpset of capacity 60 HP 3 phase servicing it throughly and carrying out the repairs such as replacing the worn out bearings / bushes gland rope nuts bolts washers greasing and bringing it to workable condition and connecting up of suction and delivery pipe lines and electric comections including testing complete all as specified and as directed
S&F in repairs Hose Box made of 18 gauge MS sheet 800 mm x 600 mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted with fire red out side and brilliant white inside for keeping 2 Nos hose pipe of lenghth 15 mtr each complete all as specified and as directed.
S&F in repairs 63 mm bore 15 mtr long hose confirming to IS-636 complete with male and female coupling confirmed to IS- 903 including dismantling of existing unserviceable one complete all as specified and as directed.
Supply & fixed in repairs fire hydrant landing valve type 'A' (Single head out let) of 63 mm dia conforming to IS-5290 complete all as specified and as directed.
Supply & fixed in repairs fire hydrant landing valve type 'A' (double head out let) of 63 mm dia conforming to IS-5290 complete all as specified and as directed.
Supply and fixed in repairs hose reel drum of 20 mm dia and 30 mtr length including branch pipe and nozzle confirming to IS-5132 complete all as specified and as directed.
Supply & fixed in repairs branch pipe gun metal 63 mm instantaneous inlet, made threaded outlet, 15 mm bore short complete all as specified and as directed.
Supply & fixed in repairs GI tubing medium grade of 100 mm bore ISI marked including necessary fittings including taking down complete all as specified and as directed.
Supply & fixed in repairs GI tubing medium grade of 80 mm bore ISI marked including necessary fittings including taking down complete all as specified and as directed.
Supply and fixed in repairs buttter fly valve of 100 mm dia including necessary gaskets and fittings etc complete all as specified and as directed.
Supply and fixed in repairs buttter fly valve of 80 mm dia including necessary gaskets and fittings etc complete all as specified and as directed.
Supply and fixed in repairs star delta starter fully automatic type ML-2, 3 Phase, 415 Volts complete with Over load relay, single phase preventor, on off switch etc complete all as specified and as directed.
Supply and fix , connect and test DOL starter type MK-1 with sheet steel enclosures, 3 phase, 415 volts, 50 Hz suitable for motor out put of 5 HP complete all as specified and as directed.
Supply and fixed in repairs star delta starter with stainless steel enclosure fully automatic type ML -1.5, 3 Phase, 415 Volts complete with Over load relay, single phase preventor, on off switch etc complete all as specified and as directed.
Supply and fix 4 mm thick MS cover double door type welded to angle iron frame of size 40 x 40 x 6 mm thick including lifting hooks and locking arrangements of size 1.0mtr x 1..0 mtr complete and fixing in concrete with anchor fasteners and applying two coats of coal tar epoxy paint over one coat of red oxide primer including taking down existing corroded cover complete all as specified and as directed.
All as per Ser Item No 45 above but of size 1.2 mtr x 1.2 mtr
All as per Ser Item No 45 above but of size 1.5 mtr x 1.5 mtr
All as per Ser Item No 45 above but of size 1.8 mtr x 1.8 mtr
Supply and refill only granular solid calcium based chlorination / disinfectant agent having zero murcury and zero heavy metal contamination property and also having high chlorine stability period upto I year duly Packed in 45 kg sealed drum complete all as specified and as directed by Engineer- in -Charge and as approved by GE.
Supply and refill only TCCA-90 (Trichloro Isocyanuric Acid) in white granular form for disinfectant for swimming pool of super quality contains chlorine 90% duly Packed in 50 kg sealed drum complete all as specified and as directed by Engineer - in -Charge and as approved by GE.
Dismantling wrought iron or mild steel work of any description and in any position complete all as specified and as directed.
M&L for Mild Steel Framed work (Fe-410-W (gde-E-250) quality B) as in Duct covers,Chamber covers and similar works, angle or other section with gusset plates, MS Plates or sheets of any thickness, rails, braces, etc., complete, welded for fixing with and including either hooks and hinges with handles also fastening and fixing complete, using ERW or induction butt welding wherever necessary, complete all as specifed and as directed
M&L for Preparation of new or previously untreated steel surfaces of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of zinc chrome or red oxide primer complete all as specified and as directed.
Demolition of Cement Concrete of any description and in any position not otherwise described complete all as specified and as directed.
M&L for PCC 1:3:6, type C-1 mix (using 20 mm graded stone aggregate) as in coping, bed plates, etc., including weathering, slightly rounded or chamfered angles and throating including necessary form work as per requirement at site complete all as specified and as directed.
Demolition of Brick work or stone boulder masonry,Pre cast block masonry etc built in cement motor including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and as directed.
M&L for Pre-cast cement concrete block masionary PCC 1:3:6 type C-1 mix using 20 mm graded stone aggregate with solid blocks, exc 10 cm in width and setting in mortor 1:4 complete all as specified and as directed.
M&L for Rendering 15 mm thick in CM 1:6 on fair faces of brick work or concrete / block masonry surfacesand rendering is to be finished even and smooth without using extra cement complete all as specified and as directed.
Collecting water samples sending to approved laboratory and carrying out chemical and microbiological analysis for potability and producing the samples complete all as directed by the Engineer-in-Charge.
S J REDDY
Allied Constructions
GM ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .