Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 LAdmitted-Fee/PreQual/Technical/Finance | ₹2.6 L | L1 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | L2₹2.6 L+₹1,405.20 (0.55%)Admitted-Fee/PreQual/Technical/Finance OLD KARO BERMO DIST BOKARO | BERMO | BOKARO | ₹2.6 L+₹1,405.20 (0.55%) | L2 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | L3₹2.6 L+₹6,352.70 (2.48%)Admitted-Fee/PreQual/Technical/Finance PURANATAND AMILO BASTI SURHASH NAGAR BOKARO JHARKHAND 829104 | BOKARO | BOKARO | JHARKHAND | 829104 | ₹2.6 L+₹6,352.70 (2.48%) | L3 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | M/S LAND LOOSERS CONSTRUCTION L3 | Krishna Construction and Services L1 | M/s Jitendra Enterprises L2 |
|---|---|---|---|---|---|---|
| 1.01 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | 851.5 | kg. | 130 ₹1,10,695 | 125 ₹1,06,437.5 Lowest | 125 ₹1,06,437.5 Lowest |
| 1.02 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/ m²
1.9 m x 2.4 m = 4.37 sqm
1.9 m x 3 m x 2 = 11.40 sqm
3 x 1.56 x 2 = 9.36 sqm
Total 25.13 sqm
Thus, for 4 nos. of Sheds: 25.13 x 4 =100.52 sqm | 100.52 | sqm | 1,350 ₹1,35,702 | 1,340 ₹1,34,696.8 Lowest | 1,350 ₹1,35,702 |
| 1.03 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required | 7 | point | 900 ₹6,300 | 850 ₹5,950 Lowest | 850 ₹5,950 Lowest |
| 1.04 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of "Single Pole & Neutral" poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | 4 | no. | 600 ₹2,400 | 550 ₹2,200 Lowest | 600 ₹2,400 |
| 1.05 | Supplying and drawing 2 x 4 sq. mm. size of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (for Service Wire) | 34 | metre | 160 ₹5,440 | 150 ₹5,100 Lowest | 150 ₹5,100 Lowest |
| 1.06 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required | 4 | each | 500 ₹2,000 | 450 ₹1,800 Lowest | 500 ₹2,000 |
| 2.00 | Total impact of GST for the purpose of CTC | 1 | Nos | - | - | - |
Tender Value
Refer Docs
EMD Value
₹3,500
Closing Date
17 Aug 2026, 9:00 amClosed
PE EnM Karo OCP
OFFICE OF PE EnM Karo OCP
Repair and maintenance of field hut, including sheeting for its roofing and internal electric wiring meant for upkeeping of gears and apparatus to be used at different location of mines under Karo OCP, BnK Area
2026_CCL_363318_1
P.E. / Karo OCP/ e-tender/ 2026-27/ 27
Open Tender
Electrical and Maintenance Works
Item Rate
5 days
KARO OCP
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,500
19 Aug 2026
7 Aug 2026
18 Aug 2026
7 Aug 2026
17 Aug 2026
7 Aug 2026
7 Aug 2026 - 14 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | 851.5 | kg. | - | - |
| 1.02 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/ m²
1.9 m x 2.4 m = 4.37 sqm
1.9 m x 3 m x 2 = 11.40 sqm
3 x 1.56 x 2 = 9.36 sqm
Total 25.13 sqm
Thus, for 4 nos. of Sheds: 25.13 x 4 =100.52 sqm | 100.52 | sqm | - | - |
| 1.03 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required | 7 | point | - | - |
| 1.04 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of "Single Pole & Neutral" poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | 4 | no. | - | - |
| 1.05 | Supplying and drawing 2 x 4 sq. mm. size of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (for Service Wire) | 34 | metre | - | - |
| 1.06 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required | 4 | each | - | - |
| 2Total impact of GST for the purpose of CTC | |||||
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.56 MB
BOQ_376237.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .