Er Pawan Tickoo
Executive Engineer PWD RandB Electric Div Jammu
please reffer BOQ
2020_PWDJK_92927_1
e-NIT No. EDJ/246 of 2019-20 Dated 14-02-2020
Open Tender
Electrical Works
Item Rate
30 days
RS Pura
please reffer to NIT
2 documents required · 2 mandatory
₹600
Yes
Executive Engineer PWD RandB Electric Div Jammu
₹14,400
Yes
26 Feb 2020
17 Feb 2020
25 Feb 2020
18 Feb 2020
24 Feb 2020
18 Feb 2020
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. (in already laid pvc conduit and metal boxes).
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 x 1.5 Sq.mm + 1 x 1.5 Sq.mm earth wire
2 x 2.5 Sq.mm + 1 x 2.5 Sq.mm earth wire
2 x 6 Sq.mm + 1 x 6 Sq.mm earth wire
2 x 10 Sq.mm + 1 x 6 Sq.mm earth wire
2 x 16 Sq.mm + 1 x 6 Sq.mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 x 10 Sq.mm + 2 x 6 Sq.mm earth wire
4 x 16 Sq.mm + 2 x 6 Sq.mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
1 x 2.5 sq. mm
2 x 1.5 sq. mm
2 x 6 sq. mm
3 x 2.5 sq.mm
3 x 4 sq.mm
3 x 6 sq.mm
4 x 4 sq.mm
4 x 6 sq.mm
4 x 10 sq.mm
4 x 16 sq.mm
Supplying and fixing following modular type switch/socket on the existing switch box cover including connections etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Fan Regulator stepped type
3 pin top 15 Amp.
Supplying, installation, testing and commissioning of 415 volts 50 Hz DOL starter for 1 HP to 10 HP 3 phase motors.
Supplying, installation, testing and commissioning of 415 volts 50 Hz star dalta starter.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 amps & 15/16 amps. modular socket outlet and 15/16 amps modular switch connection etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. (on recessed metal boxes)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutralbus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4+12) Double Door
6 way (4+18) Double Door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Single pole and neutral
Triple pole and neutral
Supply and fixing of following sizes of PVC conduit alongwith accessories in surface/recessed including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
250mm x 300 mm x 100 mm deep
200 mm x 250 mm x 100 mm deep
180 mm x 100 mm x 60 mm deep
75 mm x 75 mm x 60 mm deep
Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 3 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly GI Electrode Earthing should be maintinance free and does not require regular manual addition of water . The earthing pit should be covered with PVC cover.
Supplying and laying 25mm x 5mm G.I strip at 0.50 metre below ground as strip earth electrode including connection/terminating with G.I nut, bolt, spring, washer etc. as required. ( Jointing shall be done by overlapping and with 2 sets of G.I nut bolt & spring washer spaced at 50mm).
Supplying and fixing MCCB in cubical panel board. Providing and fixing following rating and breaking capacity MCCB FP in existing cubical panel board including drilling of holes in cubical panel and making connections etc. as required (Make as per annexure enclosed).
MCCB FP 100 Amp. 30 KA
MCCB FP 160 Amp. 36 KA
Change Over Switch 100 A FP MCCB Type
Supplying and fixing of following rating 240/415 Volt's "C" Series miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning (Above to 32 Amp.).
TPN 63 Amp
TPN 40 Amp.
SPN 63 Amp
SPN 40 Amp.
Fabrication, supplying, installation testing and commissioning of following pannel made out of 2mm thick M.S. sheet, floor mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of 1 no incomer MCCB, MCCB type change over switch - 1 No., including providing and fixing of 3 sets of Aluminium Bus Bar 200 Amp., and 3 Nos. strip for housing MCB's 40 Nos., MF Digital Meters and other allied accessories etc. as required. (Make as per annexure). (2 Nos. Panels).
Supplying and fixing of 1.1 KV PVC insulated and PVC sheathed XLPE Power Cable of following sizes on surface/surface cable tray etc. as required including carriage upto site of work. (Make as per annexure enclosed)
16 Sq.mm 2 Core Un-Armored
50 Sq.mm 3.5 Core Armored
95 Sq.mm 3.5 Core Armored
Supplying and fixing of 48 watt LED Street Light complete with GI pipe bracket duly embeded along the parapet /wall including wiring with 1.5 sq.mm FRLS PVC insulated copper wire with controlling switch. (Make as per approved make list).
Supplying and fixing of Following light fitting with lamps on ceiling/ wall with necessary connection from ceiling rose to fitting by twin core flexible copper wire etc as required.
10 watt LED tube light fitting. 600 mm size (Make as per approved make list).
20 watt LED tube light fitting. 1200 mm size (Make as per approved make list).
Supplying and fixing of surface mounted ceiling light fitting decorative type suitable for 1 No. 9 watt LED lamps. (Make as per approved make list).
Supplying and fixing of Musical Bell including making complete connections etc. as required. ( Make as per annexure).
Supplying and fixing of Angle/Baten Holder with 9 watt LED Lamp polycarbonate including making complete connnections etc as required. (Make as per annexure enclosed)
Supplying and fixing of following electrical items suitable for operating on 240/230Volts AC, 50 Hz supply. including connections etc. as required.
Ceiling fan 600 mm sweep alongwith 1'-6" long fan rod. (Make as per approved make list).
Ceiling fan 1200 mm sweep alongwith 3'-00 long fan rod. (Make as per approved make list).
Ceiling fan 1200 mm sweep alongwith 1.5'-0" long fan rod. (Make as per approved make list).
Exhaust fan 300 mm size (Heavy Duty) (Make as per approved make list).
Exhaust fan 450 mm size (Heavy Duty) Prefered make as per list of approved make.
Wall fan 400 mm size (Make as per approved make list).
GLOBAL ENGINEERS
SV ELECTRICALS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .