Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.2 LAccepted-AOC 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | L1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L2₹23.7 L+₹1.2 L (5.21%)Rejected-Finance 337 B ROAD NO 04 ASHOK NAGAR RANCHI 834002 JHARKHAND | RANCHI | JHARKHAND | 834002 | L2 | Rejected-Finance Not Lowest |
Tender Value
₹19.5 L
EMD Value
₹39,000
Closing Date
22 Feb 2020, 6:00 pmClosed
CWE Ranchi
HQ CWE RANCHI MES DIPATOLI CANTT PO RMCH RANCHI-834009
REPAIR / REPLACEMENT OF HT DISTRIBUTION EXTERNAL ELECTRIFICATION SYSTEM OF 33KV AT NAMKUM, KHOJATOLI AND LPH AREA UNDER GE RANCHI.
2019_MES_310855_1
80599/1267/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Ranchi
Class E, category b(iii)
7 documents required · 7 mandatory
₹500
Yes
GE RANCHI
₹39,000
Yes
4 Mar 2020
23 Jan 2020
25 Feb 2020
23 Jan 2020
22 Feb 2020
10 Feb 2020
Amount
Supplying, fixing, installing and commissioning and testing of 33KV 1-Ø Phase Outdoor Oil Immersed Dead Tank PT. Details as under:- Ratio : 33000/ 110 V Winding- I : 50VA, Class 0.5 Over Voltage Fact. : 2 Cont & 1.5 for 30 Sec. H.T Neutral : Earthed Insulation Level : 36KV/70KV/170KVp Creepage Dist. : 900 mm. (Min.) Tank Finish : PU Painted to light grey shed No.631 of IS 5 OGA Drg. : C388T Standard S 3156-1992 Incl Terminal Connectors. complete all as specified and directed. (Make- Sumnan conrtoller , Kappa, Laxmi or equivalent).
Supplying, fixing, installing and commissioning and testing of INDOOR RESIN CAST CT, 11 KV, CTR: 200-100/5+5 A CORE-1: 15VA, cl. 1.0, CORE-2: 15VA, 5P10, CORE-2: 15VA, 5P10, STC: 18.4KA for 1 sec. complete all as specified and directed (Make- Sumnan conrtoller , Kappa, Laxmi or equivalent).
Supplying, installing, in replacement HRC fuses 16 Amps capacity complete all as specified and as directed. Make:- HPL, AE
Supplying, installing, in replacement of HV rectifire operating Aux 30/110 volt AC/DC with NO NC complete all as specified and as directed. Make:- AREVA
Supplying, fixing, installing and commissioning and testing of plug in trip circuit supervision relay suitable for operation on 110 volts, as per sample including taking out old unserviceable complete all as specified and as directed. Make OEM
Supplying, installing, in replacement of 220 Volt AC/ DC Motor 500 Watt complete all as specified and as directed. Make AREVA, SCHNEIDER
Supplying, installing, in replacement of Hooter complete all as specified and as directed.
Supplying, installing, in replacement of LED indicator lamp complete all as specified and as directed. Make:- HPL, AE
Supplying, installing, in replacement of closing coil complete all as specified and as directed. Make . AREVA, SCHNEIDER
Supplying, installing, in replacement of connector complete all as specified and as directed.
S& F cable jointing kit for 11 KV grade cable for out door termination heat shrinkable type jointing complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sq mm complete all as specified and directed.
Testing of 33/11 KV Panels and Breakers load test, off load test, over current test, trip test, earth fault test complete all as specified and as directed.
M&L for earthing with super power galvanized steel earth electrode GI pipe medium grade of size 300mm x 110mm dia filled with chemicals buried directly in ground by means of drilling holes and connected to galvanized earth lead wire of size 4 mm dia (32x6)mm GI earth strip by means of nuts, bolts, checks but and washers made of galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I (2009) connected to earth dolly of main DB/main switch all as specified and directed, including construction of earth camber with PCC (1:3:6) type causing stone aggregate with MS cover 10 mm thick of size (300x300) mm as directed, 20 mm bore GI watering pipe (medium grade) and earth protected by galvanized iron pipe 40 mm bore (light grade) and earth wire mesh, funnel, charcoal and salt in alternate layers including necessary excavation and earth work in soft / loose or any type of soil and dismantling of the existing rusted / deteriorated one complete all as specified. Note:- Earth wire up to 7.5 meter connected to earth point shall be deemed to be included in unit rate.
Disconnecting and Strip opening transformer 63 KVA to 100 KVA, 11 KV/433 volts indoor /outdoor type of any make after unscrewing nuts /bolts, screws and connected accessories such as breather conservator tank, temperature gauge for replacement of defective HT /LT coils ,defective parts (payment of defective parts to be replaced shall be measured and paid separately), reassembling after replacing the defective coils /defective parts and replacing the top gasket sheet and other insulating packing materials and testing complete all as specified and directed including taking out, handling of distribution transformer of any size any capacity to workshop & back to the installation. (Note :- The reassembling element covers the assembling of parts not to be changed whereas for the rest it shall be the part of the item being replaced.) (Cost of transportation of transformer is deemed to be included in rate)
Description same as per srl item No. 14 here-in-before but 150 KVA to 500 KVA complete all as specified and directed.
M&L rewinding of transformer of any capacity HT/LT coils using the same gauge of super enameled copper winding wire and replacing the old paper tape insulation, necessary insulation packing’s/ paper insulation etc with replacement of crap tape, prosen sheet, silphase brazing rod, HT block, LT block etc are included, complete all as specified and as directed. (Note –The coil replaced shall have same number of turns, gauge, insulation value matching as per manufacture’s design. Measurement shall be made of winding wire consumed.)
Supply and replacement HT 11 KV Bushing Insulator suitable for indoor / outdoor type 25 to 500 KVA transformer complete with brass stud, 3 Nos brass nuts, brass cup/washers and packing gasket complete all as specified and directed.
Complete testing of transformer consisting of IR value of both HT< side earth resistance of all the four earths, dielectric strength of transformer oil etc complete all specified and as directed.
Supply and replacement brass stud for LT side suitable for transformers 100 to 500 KVA complete all as specified and as directed.
Supply and replacement temperature gauge 0-100 degree Celsius range circular type complete all as specified and directed.
Supply and fill up transformer oil as in topping up/refilling of transformer having dielectric strength not less than 50 KV at 2.5 mm gap conforming to IS-335 by heating up and after filtration complete all as specified and directed.
M&L for ON LINE dehydration/filtration with machine (not small filtration portable machine) to achieved the specified dielectric strength complete all as directed of transformer pole mounted or platform mounted of any capacity complete all as specified and directed.
M&L for OFF LINE dehydration/filtration with Ultra High Vaccum machine (not small filtration portable machine) to achieved the specified dielectric strength complete all as directed transformer platform mounted of 33/11KV transformer 3.15 MVA capacity after filtration dielectric strength not less than 60 KV at 2.5 complete all as specified and directed.
Supply and replacement transformer breather complete with silcagel for capacity 50 to 500 KVA transformer complete all as specified and directed.
Supply and replacement transformer breather complete with silcagel for capacity 3.15 MVA transformer complete all as specified and directed.
Supply, installation, testing and commissioning of early streamer emission (ESE) lighting air copper terminal 300mm configured was accessories mentioned below for protection of radious 15 mtrs at very high level and tested & certified as per NFC-17-102 standerd for lightning current inpulses of 100 KA in 10/350 wave form:- (a) Maintenance free chemical earthing with copper earthing electrode110mmX3000mm alongwith 50Kg of back fill grounding materials complete with CPRI & BIS certified. (c) Single core multi stranded insulated copper strip 25X3mm size for connection of ESE to earthing pit (d) Test clamp and other accessories such as U clamp ring fasteners, staywires, insulation all as required complete all as directed. ( Note:- Test certificate shall be submitted after competion of work)
Excel Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .