Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
6 Feb 2021, 6:00 pmClosed
GE ALWAR
GE ALWAR
PROVN OF ONE SPLIT AIR CONDITIONER IN TELECOM SEC OF 878 FD WKSP COY (642 EME BN) AT JP LINES, ALWAR
2021_MES_415108_1
3000/Q/113/E3
Open Tender
Electrical and Maintenance Works
Works
30 days
ALWAR
AS PER DOC
2 documents required · 2 mandatory
₹0
Exempted
17 Feb 2021
23 Jan 2021
8 Feb 2021
23 Jan 2021
6 Feb 2021
30 Jan 2021
23 Jan 2021 - 29 Jan 2021
Amount
Supply and install hi wall Dual Inverter Compressor with varied speed Dual Rotary Motor, High temperature cooling score of 5, 100% Copper with Ocean Black protection, Hi Grooved Copper split type AC cooling only with smart ThinQ and Mosquito Away units indoor/outdoor complete with cordless remote control unit and with in built air ionizer and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity as 1.5 TR, Cooling 3470Watt, Make :-LG Cat Part No KS-Q12ZWZD or equivilant make Voltas/Hitachi/Feeder Lolyed.
Supply and lay cable XLPE Insulated screened Meter PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core.
M & L Sub main wiring with 2 runs of 6 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 bolts grade cable drawn through and including PVC conduit and conduit accessories consealed in wall, ceiling etc. ISI marked 32mm dia (external) with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof and one run of 6 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 volts grade cable as earth conductor complete as specified.Note : Two runs of 6 Sqmm cable, one run of 6 Sqmm earth conductor shall be measured and paid as one length along with one run of PVC conduit.
S&F factory made Double Door sheet metal enclosure DB SPN 4 way, 200 Amp rated tinned copper bus bar for mounting MCBs (Make Legrad/Havells/standard).
Supply and fix MCB SPN 32 Amps make Legrad/Havells/Standard
Supply and fix MCB SP 32 Amps make Legrand/Havells/Standard
Material and Labour for provision of PVC HDPE drain pipe of 25 mm dia concealed/surfaced to the wall/floor etc for drain out condensed water incl making good to the disturbed surfaces complete all as specified.
Supply and fix single pole and netural enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp (Make : of Legrand /Havells/ Standard.
Supply and fixing voltage stabilizer for automatic operation single phase naturally cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of +2.5% and of capacity 5KVA.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5m deep below normal ground level and connected to and including galvanized iron earth wire 4mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-1 and connection to main switch board/Test point/pane/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 meter, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 meter long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25mm x 3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & directed.
Excavating in trenches not exc 1.5 meter wide and not exc 1.5 meter in depth for foundation or for shafts, walls, manholes, laying of cables, pipes etc not exc 10 Sqm on plan and getting out in soft/loose soil.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil.
Removal of excavated soil/material to a distance not exc 50 meter and depositing where directed at a level not exc 1.50 meter above the starting point complete all as specified.
M/L for brick work with FLY ASH BRICKS (As Per IS-13757(1993) burnt clay fly ash building bricks), (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection and complete all as specified & directed.
M&L for dry sand and punning for cushioning to underground cable all as directed. Note:- For the purpose of payment only punned thickness shall be measured.
M/S NAVEEN ELECTRICAL
Shiv Enterprises
J.P. Enterprises
DP Traders
D P ENTERPRISES
OM Associates
N.K. Enterprises
D.P. Air Conditioning Services
Saini Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .