| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance KHASRA NO 145 GROUND FLOOR NEAR JAIN MOHALLA JATO KI CHOPAL VILLAGE KHERA KALAN NEW DELHI 110082 | NORTH | DELHI | 110082 | Admitted-Finance |
| 3 | Admitted-Finance H NO 31 DUPLEX MOTIAZ ROYAL FAME VILL CHAJJA MAJRA PO LANDRAN SEC 117 DISTT SAS NAGAR MOHALI PB PIN 140307 | S A S NAGAR | PUNJAB | 140307 | Admitted-Finance |
| 4 | Admitted-Finance PREM NAGAR GALI NO 3 RAJPUTANA SALEMPUR ROORKEE DISTT HARIDWAR UK | ROORKEE | HARIDWAR | UTTARAKHAND | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹66.6 L
EMD Value
₹1.2 L
Closing Date
10 May 2025, 6:00 pmClosed
CWE Hills Dehradun
HQ CWE Hills Mall Road Dehradun Cantt 248003
PROVN OF WATER SUPPLY AT KHAB UNDER GE 863 EWS
2025_MES_703761_1
88036/EWS/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
GE 863 EWS
Class C Cat b (i)
6 documents required · 6 mandatory
₹1,000
Yes
GE 863 EWS
₹1.2 L
Yes
2 Jul 2025
7 Apr 2025
19 May 2025
7 Apr 2025
10 May 2025
23 Apr 2025
Amount
Supply & Laying in trenches 3- layer PP-R (Polypropylene random copolymer) 63 mm outer diameter conforming to IS 15801 concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random complete fittings all as specified and directed.
S&F PP-R Gate Valves (brass insert) as per requirement of the site of size 63 mm dia bore (outer dia of pipe in mm) compete all as specified and directed.
S&F high pressure single head chemical dosing system of power input 230V, 50Hz, 40SPM, 1/30 fractional HP, pressure 5 Kg/ Sqcm of maximum output 6.5 ltr / hrs with complete accessories like lead tubing, connecting ferrule, check valves etc of following accessories. (a) High pressure single head chemical dosing system of power input 230Volt, 50 Hz , 40 SPM , 1/30 fractional HP, pressure 5 Kg/sqcm with max output 6.5 ltr/hrs with complete accessories like lead tubing, connecting ferrule, check valves etc (b) 100 liters FRP dosing tank TOP dia 540mm x bottom dia 480mm x height 575mm consisiting of water inlet line. Dosing pump inlet arrangement, Drain overflow level guage , inspection port etc complete (c) Agitator 120 Watt 900 RPM single phase flange mounted with plastic shaft and impeller with complete accessories. (d) Injection dosing system with PPM Cpntrol. Note :- (i) Required Electric connection (cable) with Electric protection and PCC foundation with working sapce for chemical dosing system will be provided by the contractor as per recommendation of OEM demeed to be included in above rates.
Supply only Calcium hyochlorite 65% to 70% chlorine contents in granular form (calcium based Granular disinfectant for water treatement all as specified and directed.
M&L for making connection of PP-R existing distribution branch with PP-R pipe of size 63 mm outer dia by providing necessary fittings including cutting and making fusion joints complete all as specified and directed.
Excavating in trenches n'exc 1.5 m width and n'exc 1.5 m in depth for foundation or for shafts, well cesspits, manholes etc / for laying of cable/ pipe etc n'exc 10 sqm on plan and n'exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed.
Removal of surplus soil to a distance n'exc. 50 Mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
Supplying, laying, commisioning and testing of 1.1 KV grade XLPE insulated, armoured, heavy duty aluminum stranded conductor LT UG cable (Conforming to IS 7098), ISI marked, in trenches / ducts / through GI pipes under roads of following size complete all as specified and directed:- Note:- 1. The earth work, GI pipe shall be measured and paid sepretely. 2. Cable may fixing/ passing through pipe laid in trenches or fixed to pole/ wall or fixed to LT panel etc.
95 Sqmm, 3½ core.
50 Sqmm, 3½ core.
25 Sqmm, 3½ core.
10 Sqmm, 2 core.
Supply & laying three Core PVC Insulated & PVC Sheathed Industrial Submersible Copper Cable of 25 Sqmm x 3 Core , conforming to IS 694 clamped HDPE protection pipe of cable over the PCC foundation block all as specified and directed. Note :- HDPE pipe and PCC block will be paid and measuresd seperately is respective items.
M& L for High density polyethylene pipes (HDPE) of pressure rating PN-10 fixed complete to Road, Hard standing and over brick block etc for cable protection of size 50 mm bore all as specified and directed.
M & L for High density polyethylene pipes (HDPE) of pressure rating PN-10 fixed complete to Road, Hard standing and over brick block etc for cable protection of size 100 mm bore all as specified and directed.
Supply, installation, commissioning & testing Voltage Stabliser copper wound of capacity 75 KVA (or next available higher capacity ) for automatic operation, 3 phase, naturally oil cooled, indoor type & designed for input variation between 300V to 480V, 47Hz to 53Hz with output voltage stablised at 415V with accuracy of + 2.5 % for unbalanced load condition and speed of correction 8 volts per second and overload capacity 120% for 10 minutes and 150% for 1 minutes with overall efficency more than 95% and equipment having protection from under/over voltage, single phase preventer, overload protection, short circuit protection including ampere meter for measuring current for three phases & voltmeter for measuring input/output voltage, frequency meter, with bypass arrangement and initial fillling of transformer oil (Make of Transformer oil : Savita/ Powerlink/ Equivalent make as per IS as approved by GE complete all as specified and as directed. NOTE:- The rate quoted by the contractor is deemed to be inclusive of first filling of oil. (ii) The rates include for supplying Voltage stabilizer with standard fittings and installing complete including all jointing materials, connecting with electrical system. (iii) Voltage stabilizer having four wheel for easy movement and mounted on channel MC 100 as per IS 808 (Part-III)
Supply, Installation, Testing and Commissioning (APFC Panel) MD—XL Double metalized paper (Extra Low Loss) Capacitor for 3 phase, 440 V, 50 Hz system for permissible non- leaner load 20% of capacity 30 KVAR complete all as specified and directed.
M&L Synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
Supplying, transporting, erection & fixing of new steel tubular swaged poles type 410 SP-31, (9.00 metres long), with cast iron base plate, finial taper plug, bolts, nuts and screws complete as specified with and including two coats of aluminium paint over a coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embeded in PCC with and including all necessary excavation & earth work in any type of soil for foundation of poles, PCC 1:3:6 type 'C2' (using 40 mm graded stone aggregate ) in foundations of size 600 X 600 X 1650 mm below GL, PCC 1:2:4 type "B2' (using 20 mm graded stone aggregate) in plinth block(coping) of size 600 X 600 X 300 mm above GL , removing surplus soil to a distance n. exc. 50 m & depositing where directed, and writing numbers of poles in 100 mm dia yellow colour circle with black paint including 30 cm wide alternate black bands (03 Nos) upto 1.5 height from top of copingcomplete all as specified and directed.
S&F LED energy saving and enviromental friendly long life LED Street Light 70 Watt made up of preeure die cast aluminium housing with high effciency LED as light source and Toughened glass having bottom opening seperate driver compartment with IP 66 protection and impact resistance of IK07 including three core PVC cable of 1.5 sqmm and PVC conduit of 20 mm dia from junction box to steet light complete all as specified and directed .
M&L SMC street light Junction box weatherproof, shockproof and rustproof, pole mounting arrangement suitable for 25 sqmm 4 core cable entry and outgoing including suitable capacity bus bar and MCB SP complete all as specified and directed.
M&L Street light bracket made out from GI Pipe 40 mm bore light grade 1.20 meter long bent to required shape and fixing to pole, walls etc including fixing of clamp, nut, bolt etc as specified and directed.
Supply, install, testing and commissioning street light Panel Astronomical switch of 6 KW , contractor rating 32 A TP, MCB 40 A TPN of 3 phase conforming to IS of IP 54, in built short circuit protection with FRLS internal wiring of class H insulation complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600mm X 600mm X 6mm thick buried directly in ground vertically earth pit not less than 2.25 meter deep below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI earth strip of size 32x6 mm as earthing lead by means of bolts, nuts and washers all as shown in electrical plate No 3 of MES Scedule part I (2009) with conected to eath test point including adequate quantity of charcoal dust and comman salt, PCC (1:3:6) type C-1 chamber and for earth pit with 40x40x6mm mild steel angle iron frame for cover. precast RCC cover 40mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia round bars both ways with MS handle 8 mm dia. PGI funnel and wire mesh 20 mm dia GI pipe medium grade for watering and 40mm dia medium grade GI pipe as earth lead protection pipe complete all as specified and directed. (Earthing for LT Panel-02, VS-02, APFC-02) Note: GI earth strip and protection pipe upto and including 7.5m is deemed included in unit rate quoted by contractor.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground, earth pit not less than 2.25 mtr depth below ground level at any type of strata with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate, connected by 4 mm GI wire as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC (1:3:6) type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM (1:4) funnel with wire mesh, RCC pit cover of 320 x 320 x 80mm size PCC (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick reinforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
Supply and laying cable protection bricks, common burnt clay sub class 'B' designation 75 for protection of UG cable laid in trenches with axis of the bricks perpendicular to the axis of the cable complete all as specified and directed.
Returning and filling in two parts (i) using riddled soil obtained from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil complete all as specified and directed. Note- Excavated soil shall be riddled by using sieve to separate composite particles etc and refilling in trenches as in cable cushioning.
M&L for PCC (1:4:8) Type D2 (40 mm graded aggre-gate) as in foundations, filling and mass-concrete or sub base of floor/ hard standing/ footpath,pole complete all as specified and directed.
M&L for PCC (1:3:6) Type C2 (40 mm graded aggregate) as in foundations, filling and mass-concrete, Pole complete all as specified and directed.
M&L for PCC (1:2:4) type B-1, using 20mm graded stone aggregates, as in kerb/ benching/ coping, bed plates, for fixing of hold fast, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed.
M&L for 10mm thick plastering on fair faces of brick wall in CM (1:4) surface finished even and fair complete all as specified and directed.
Supply, Installation, Testing and Commissioning of silent Diesel Engine capacity 58.5 KVA Gen Set developing 75.5 BHP @ 1500 RPM, 415 Volts (AC 3 phase, 4 wire system of supply) driven eco friendly generating set confirming to statutory Govt CPCB IV + emission norms level norms , compact size with Manual / Automatic starting system, sound proof enclosure, low vibration, best in class fuel consumption with electronic fuel injection system, class G3 Governing in its range, directly coupled alternator and engine , water cooled, mounted on common base plate of rigid fabricated mild steel frame platform with fuel tank 156 ltr and including all Earth work , PCC fundation for DG Set inculding 1 meter working space all around, anti vibration pads / dampers including standard control panel as per OEM and other accessories as per manufacturers design. The Gen Set should be fitted with integrated acoustic enclsure is of modular construction as per OEM of the Generating Set. Specification of DG Set and AMF control Panel shall be as specified and comprising of the following:-
Silent features of DG Set:- (a) High water temprature (b) Low lube oil pressure (c) Emergency stop push button outside the enclosure (d) DOC, EGR (e) Cold Start feature (f) Specially designed standard control panel is mounted inside enclosure itself (g) In buit draw in type fuel tank tank of adequate capacity to meet the fuel requirement of 8 Hrs Run. (h) UV resistant powder coating can withstand extreme environments (j) The wall of the enclosure are insulated with fire-retardant and noise absorbent PU foam as to comply with the noise level of 75 dB (A) at distance of 1 mtr in open free field environment as per ISO 8528 part 10 specified by ministry and forest. (k) Fluid drains for lube oil and fuel.
Diesel Engine : Diesel engine of capacity of 58.5 KVA, 04 cylinder, water cooled , Turbocharged intercooled, developing 75.5 BHP aat 1500 RPM, electric start, compression ignition, 4 stroke engine designed to run continuously @ 1500 RPM. The Diesel Engine conforms to present CPCB IV + norms. The diesel engine comprise of following:- (a) Radiator with fan (b) Electric starter motor with soft starting system (c) Electronic Governor (G3 as per ISO 8528 Part V class governor) (d) Battery charging alternator (e) Dry type Air Cleaner with service indicator (f) CRDI System (g) Lubricant oil and fuel filter (h) DOC, EGR (j) First fill of lube oil and coolant (k) Battery as per OEM.
Alternator : Alternator capacity of 58.5 KVA suitable for continuous opertation rated at 1500 RPM, 415 volt, 0.8 PF, 50 HZ three phase in SPDP enclosure, self-excited, self-regulated brush less, floor mounted. The alternator confirming to IS:4722, BS EN 60034-1 and will be suitable for tropical condition.
Acoustic Enclosure : Provision of an integral type approved and certified accoustic enclosure insulated with fire-retardant and nosie abosorbent PU foam so as to comply with nose level of 75 dB(A) at distance of 1 meter in open free field environment as per ISO 8528 Part 10 specified by Ministry of Environment and Forest include of following :- (a) The enclosure is of modular construction (b) Durable industrial locking system is provided on door. (c) The sheet metal componenets are pre-treated and are polyester based powder coated (inside as well as out side ) for long life. (d) Specially designed sound attenuators are provided to control sound at air entry and exit points in side the enclosure.
AMF Control Panel : Supply, Installation, Testing and Commissioning the standard AMF Control Panel is manufactured 3.15mm thick CRCA an is powder coated sheet outdoor type , weather proof and long lasting finish. The AMF control panel consistss of the following :- (a) Microprocessor based Gen set controller of - 12 V DC - 01 No (b) Toggle Switch -15 A 28 V DC- 01 No (c) LED Indicating Light -12 V DC- 01 No (d) Illuminated push button (Red) - 01 No (e) Illuminated push button (Green) - 01 No (f) Slector switch for by Pass -6A - 01 No (g) Pannel Door Lock - 02 Nos (h) Control MCB 1P - 32A - -01 No (j) Fuse Terminal Block with 2A Glass Fuse- 110-240V- 10 Nos (k) Fuse Terminal Block with 5A Glass fuse - 110-240V - 01 No (l) Automotive Relay - 12 V DC - 05 Nos (m) Battery Cahrger - 12V- 2.5A - 01 No (n) Buzzer 12 V DC- 01 No
(o) MCCB 3P 10 KA - 100Amp - 02 Nos (p) Power contactor FP - 100Amp - 02 Nos (q) Add on Block (01 No + 1 NC) - 01 No (r) Add on Block (02 No + 2 NC) - 01 N0 (s) Surge Suppressor - 02 Nos (t) CTS CL 1.0 100/5A - 03 Nos (u) Power Terminal FP - 100A - 01 No (v) Lugs for power wire - 01 Set (x) Lugs for control wire - 01 set (y) Panel box powder coated 3.15mm thick CRCA Sheet outdoor type (z) Control wire FRLS 0.75 - 4 sqmm (aa) Power cable size 8 - 01 set (ab) Hardware 58.5 KVA Note :- The Gen Set controller has all the basic safeties and protection as per OEM demeed to be included in above rates.
Dharm Singh Contractor (BID ID -3289377)
M/S Konark Electric Sales Corporation (BID ID -3289310)
Ravi Electrical (BID ID -3289349)
Chankaya Solutions (BID ID -3289266)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .