Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC Being lowest bidder for the work | |
| 2 | L2₹10.4 L+₹76,870 (7.95%)Rejected-Finance HOUSE NO C 214 SECTOR C INDRA VIHAR COLONY TILAK NAGAR HOUSING SOCIETY AIRPORT ROAD LANDMARK NEAR BHOPAL GIRLS SCHOOL PANCHVATI BHOPAL MP 462030 | BHOPAL | BHOPAL | MADHYA PRADESH | 462030 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹10.8 L+₹1.1 L (11.6%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
₹11.3 L
EMD Value
₹22,600
Closing Date
26 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commander Works Engineer Bhopal
Headquarters, Commander Works Engineer, Bhopal, Military Engineer Services, SI Line, Bhopal, Pin Code - 462001 (Madhya Pradesh)
REPAIR AND MAINTENANCE OF HT 33 KV SUBSTATION AND ALLIED WORKS UNDER EXTERNAL ELECTRIC SUPPLY AT DSCC AYODHYA NAGAR UNDER GE DRONACHAL
2021_MES_452368_2
83656/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bhopal
AS PER NIT CONDITION
7 documents required · 7 mandatory
₹500
GE DRONACHAL
₹22,600
Yes
10 Sept 2021
7 Aug 2021
28 Aug 2021
7 Aug 2021
26 Aug 2021
14 Aug 2021
60 days
Amount
Dismantling insulators any type, any size complete all as specified and as directed.
Dismantling cross-arms of mild steel channel or angle sections etc. complete and setting aside for re-use or removing to store or for schedule of credit
Dismantling air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism and taken on schedule of credit complete all as specified and as directed.
Dismantling ACSR or AAC conductors removing to store or taken on schedule of credit complete all as specified and as directed.
Dismantling and taking down Lightning arrestor of any size .
Disconnecting, taking out old unserviceable under ground cable of rated voltage 19 kV/ 33 kV, upto any size of nominal cross sectional area of main conductor, upto 4 core, any type from trenches including taking out concrete cable cover/ bricks etc. including removing materials to store for keeping in safe custody or for reuse or for taking credit (credit for above items should be made as per conditions separately) all as specified and directed by the Engineer-in-Charge.
Taking up or down old unserviceable GI pipe of any size fixed/ laid in any position, keeping serviceable materials separately for reuse at site or removing to store or taken on schedule of credit complete all as specified and as directed.
Dismantling and taking down of End termination/ Straight through cable joint of any size, any type, any numbers of core for voltage 19 kV/ 33 kV (Earthed)
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in hard/ dense soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
Disconnecting, taking out old unserviceable under ground cable of rated voltage 19 kV/ 33 kV, nominal cross sectional area of main conductor 240 sqmm, upto 4 core, any type from trenches including taking out concrete cable cover/ bricks etc. including removing materials to store for keeping in safe custody or for reuse or for taking credit (credit for above items should be made as per conditions separately) all as specified and directed by the Engineer-in-Charge.
Supply, laying and testing cross linked polyethylene (XLPE) insulated, PVC sheathed cables for working voltages 19 kV/ 33 kV, three phase, earthed system, 1 core, screened, armoured power cable, 240 sqmm of nominal area of conductor, aluminium conductor, ISI marked as per IS 7098 (Part-II): 2011 laid in trenches or under floors making all connections with necessary glands lugs bushing complete all as specified and as directed.
Disconnecting, taking out old unserviceable under ground cable of rated voltage 19 kV/ 33 kV, nominal cross sectional area of main conductor 185 sqmm, upto 4 core, any type from trenches including taking out concrete cable cover/ bricks etc. including removing materials to store for keeping in safe custody or for reuse or for taking credit (credit for above items should be made as per conditions separately) all as specified and directed by the Engineer-in-Charge.
Supply, laying and testing cross linked polyethylene (XLPE) insulated, PVC sheathed cables for working voltages 19 kV/ 33 kV, three phase, earthed system, 3 core, screened, armoured power cable, 185 sqmm of nominal area of conductor, aluminium conductor, ISI marked as per IS 7098 (Part-II): 2011 laid in trenches or under floors making all connections with necessary glands lugs bushing complete all as specified and as directed.
Supplying & laying including taking town in trenches, in road cutting and along pole 100 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
M & L for auguring under road, pavement, hard standing, railway lines by trenchless technology using latest boring technique and necessary machine for insertion of GI pipe of 65 mm to 100 mm nominal bore complete all as specified and as directed.
Supply & laying reinforced precast concrete cable cover class EHV type 1, with peak shape, dimension 450 mm X 230 mm X 50 mm and 75 mm peak thickness as per IS 5820: 1970 complete all as specified and directed.
S & F XLPE cable end termination, heat shrinkable, outdoor type complete with jointing material and accessories suitable for voltage 19 kV/ 33 Kv (Earthed), 3 core, 120 sqmm to 185 sqmm complete all as specified and as directed.
S & F polymer pin insulator, Type B, Nominal System voltage 33 kV, highest system voltage 36 kV, visible discharge test voltage 27 kV, wet power frequency withstand voltage 75 kV, power frequency puncture withheld voltage 180 kV, impulse withstand voltage 170 kV, minimum total creepage distance 580 mm, minimum failing load 10 kN, of suitable size with galvanised steel insulator pin, nut, washers complete all as specified and as directed.
S & F polymeric composite disc insulator, ball and socket type, Type B, Nominal System voltage 33 kV, highest system voltage 36 kV, visible discharge test voltage 27 kV, wet power frequency withstand voltage 75 kV, impulse withstand voltage 170 kV, minimum total creepage distance 580 mm, minimum failing load 70 kN, of suitable size with galvanised steel stud pin, nut, washers complete all as specified and as directed.
M & L for cross arms, bracings, supports, clamps, back plates and stay clamp fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
Fixing only cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
Supply, fixing and stringing ACSR (aluminium conductor galvanized steel-reinforced) of any size and type in accordance with site requirement and binding on insulator by means of 22 gauge aluminium binding wire to permissible sag complete all as specified and as directed.
S & F gang operated air break switch, three poles, outdoor type, nominal system voltage 33 kV, rated voltage 36 kV, rated normal current 400 Amps, rated frequency 50 Hz, rated one minute power frequency withstand voltage between (i) earth & poles 70 kV (rms) (ii) across the isolating distance 80 kV (rms), rated lightning impulse withstand voltage (i) to earth and between poles 170 kV (Peak) (ii) across the isolating distance 195 kV (Peak), Rated short-time withstand current 20 kA for 3 seconds, rated peak withstand current 50 kA for climatic conditions at the site, mechanically operated mounted on polymer insulator and steel frame with operating mechanism worked from ground level for current complete all as specified and as directed.
Supply and replace for DO fuse assembly, triple pole mounted on polymer HT insulator 6 Nos and mild steel galvanised steel frame rating upto 200 Amp, 33 kV complete with DO fuse and electrical connections, jumpering by ACSR conductor and connectors complete all as specified and directed.
S & F drop out fuse element for 33 kV line, 15 A with fire resistant ferrule complete all as specified and as directed.
S & F drop out fuse barrel for 33 kV line, 15 A with fire resistant tube and joint with ferrule complete all as specified and as directed.
Supply and erection in repairs of three piece metal oxide lightning arrestor suitable for 33 kV continuous operating voltage (3 phase) with rated voltage 36 kV (rms) with nominal discharge current rating of 2.5 kA and complete with galvanised clamping arrangements, GI bolts, nuts, washers etc. complete as specified and as directed.
Disconnecting the transfomer, three phase, 1000 kVA rating, 33 kV/ 433 V primary and secondary side voltage with all connections (incoming and outgoing) and carrying the open and short circuit test of transformer to determine core losses in transformer, parameters of the shunt branch of the equivalent circuit of the transformer, copper losses in the transformer at full load and to obtain the parameters to approximate the equivalent circuit of a transformer and including submission of reports with details and calculations and including reconnecting the transfomer with all connections (incoming and outgoing) complete all as specified and as directed.
Dismantling of unserviceable bushing, gasket, spindle with nuts, washers carefully without any damage to existing parts and including fixing new bushing, gaskets complete to match with nuts, washers, brass spindle for primary side terminal and including sealing materials for the transfomer, three phase, 1000 kVA rating, 33 kV/ 433 V primary and secondary side voltage complete all as specified and as directed.
Dismantling of unserviceable bushing, gasket, spindle with nuts, washers carefully without any damage to existing parts and including fixing new bushing, gaskets complete to match with nuts, washers, brass spindle for secondary side terminal and including sealing materials for the transfomer, three phase, 1000 kVA rating, 33 kV/ 433 V primary and secondary side voltage complete all as specified and as directed.
M & L for spray painting of transformers (any type power or distribution)) of capacity above 900 kVA and upto and including 1250 kVA ( in situ ) outdoor type, installed and located at different sites in scattered area under the GE including the following: - (a) preparation of old surfaces by cleaning, scrapping, rubbing/ polishing etc. complete. (b) Spray painting with two coats of synthetic enamel paint of approved make / quality all as directed at site. (c) Writing the SM MES No of transformer on MS body of transformer all as directed .
M & L for preparing and painting on steel tubular swaged pole 410 SP-55 (11.00 metre long) including cross arms, GI brackets with two coats of aluminium paint over a coat of aluminium red oxide primer on exposed portion and including making strips of width 30 cm upto 1.5 m from the ground level in black and white shade in alternate layer including numbering of poles using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Dehydration and filtration of existing transformer oil of transformer at different location with filtration machine and heating system to get the minimum di-electric strength of oil 40 kV minimum without disturbing the power supply system and refilling/ topping up /replacement of unserviceable transformer oil complete all as specified and as directed.( Note: Transformer oil required extra for filling/topping up shall be measured and paid separately under the relevant items of this schedule).
Supply, filling and topping up new transformer oil of dielectric strength not be less than 60 kV and conforming to IS 335: 1993 complete all as specified and as directed.
S & F silica gel breather including silica gel, indicating type, 4 to 6 mm standard size of the particle, blue colour for transformer of capacity exceeding 500 kVA and upto and including 1000 kVA complete all as specified and as directed.
Calibration of outdoor VCB 33 kV, 630 Amp of Make Areva including calibration of relay of indoor control panel with 33 kV / 433 V transformer of Make Kirloskar complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed by Engineer- in-charge.
M & L for loose filling with broken stone or boulder aggregates of gauge 40 to 80 mm in soakage pits, soakage wells, on open space etc. complete all as specified and as directed.
Supply and spread lime powder for two pole structures and 33 kV main receiving station complete all as specified and as directed.
Labour only for isolating of LT ACB of 1000 Amps, draw out/ taking out the same from panel for servicing & overhauling of ACB providing maintenance kit of 1000 Amp and applying petroleum jelly to the contact points/ springs and refixing the same after repair complete all as specified and as directed.
S & F nominal 3.0 mm + 10% thick insulating mats made of elastomer conforming to IS-15652: 2006 and meeting the requirement of IS- 5216 (Part -1 & 2) IS 8437, IEC-479 Pub -1 along with suitable adhesive/ homebound, PV resin water proofing compound and sealing material as per recommendation of Annex 'A’, Clause- 'C’ of IS- 15652 and suitable for class - C upto 33 kV complete all as specified and as directed.
M & L for preparation of old steel surfaces of fencing any mesh size and any nominal dia and applying two coats of Aluminium paint complete all specified and directed.
S R BUILDERS AND SUPPLIERS
M/S RAKESH TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .