| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC | L1 | Accepted-AOC lowest bid quoted | |
| 2 | L2₹21.9 L+₹3.2 L (17.0%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L2 | Rejected-Finance Highest bid quoted | |
| 3 | L3₹22.5 L+₹3.7 L (19.9%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L3 | Rejected-Finance Highest bid quoted |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
22 Dec 2021, 6:00 pmClosed
GE (AF) Gurgaon
Gurgaon
REPAIR AND MAINTENANCE EXTERNAL WATER SUPPLY SLUICE VALVE SUBMERSIBLE PUMP RO PLANT AIR CONDITIONERS WATER COOLERS DEEP FREEZERS CEILLING FAN EXHAUST FAN STREET LIGHTS LIGHTENING ARRESTOR DG SET PACKAGE TYPE AC ELECTRIC SUPPLY SYSTEM REPAIR OF ELECTR
2021_MES_490193_1
CA NO GE/GUR-/NIT-75/2021-22
Open Tender
Miscellaneous Works
Piece-work
240 days
GE (AF) Gurgaon
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹70,000
18 Feb 2022
24 Nov 2021
24 Dec 2021
24 Nov 2021
22 Dec 2021
8 Dec 2021
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.50m deep for laying of water pipe lines/taking out pipe lines or laying of electric cables and getting out in soft/lose soil including forming bottom surface to required level and slope all as specified and directed.
Returing ,fiiling including spreading ,leveling ,watering and well ramming in layers not exe. 25 cm soil all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the strarting point.
Supply laying, testing GI tubing 80mm bore medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and directed.
M&L 3- LAYER PP-R (Polypropelene random copolymer ) pipes SDR-11,PN 10 UV stabilised and antimicrobial welded having thermal stability for hot & cold water supply including all PP- R Plain & brass threadedpolypropelene random fitting fixed complete to walls , ceiling or in trench size 50mm all as specified & directed
Supply laying, testing GI tubing 25 mm bore medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and directed.
Supply laying, testing GI tubing 20 mm bore medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and directed.
Taking up cast iron water mains 100/150 mm bore (including all fitting ),with spigot and socket ends/flanged ends /rubber gasket joint including disconnecting complete all as specified and as directed
Supplying and laying ,testing Cast iron pipe 100mm bore with spigot and socketed end ,class LA ,in any length laid in trenches /on pedestals complete all as specified and as directed.
Supplying and laying ,testing Cast iron pipe 150mm bore with spigot and socketed end ,class LA ,in any length laid in trenches /on pedestals complete all as specified and as directed.
Supply,laying and jointing cast iron bends (any type ,radius and angle )tapers any type ,(straight ,bend,increasing ,decreasing or double socket etc) Tee pieces single branch ,cross (all sockets or socket and spigot /all flanged or one end flanged and other end spigot ,socketed )collars ,caps and plugs conforming to IS upto 150mm bore complete all as specified and as directed
Drilling and tapping cast iron water mains for branch connection of the internal dia 20mm including clamp piece and nuts and bolts and directed.
M&L run lead joints for following sizes of CI spun pipes /fittings complete all as specified and directed.
Taking down of existing GI tubing 40/50/80mm bore any type.
Taking down of exixting GI tubing 25mm bore any type.
Taking down of exixting GI tubing 20mm bore any type.
Taking out sluice valve /NRV of size 100mm/150 mm from existing distribution CI /DI mains all as specified and as directed.
Lifting of submersible pump set any description from borewell including column pipe and submersible cable and lowering of pump in bore well after repair of the pump/motor all as directed Note: cost of disconnecting pipe from header / cables from panel shall be deemed to be included in the quoted rate.
M&L for repairs & Servicing of defective submersible pump of capacity up to10 HP by dismantling the pump & removing unserviceable parts , assemble the pump properly after replacements of unserviceable parts complete all as specified and as directed . Note:- (a) The rates are inclusive of transporting the pump from bore well site to repair work shop & back to site. (b) The rate are inclusive of turning / finishing work for fixing of parts properly. (c) The replacement of unserviceable parts will be measured and paid separately under respective item of this schedule.
M&L for rewinding of Submersible motor by taking out burnt copper winding, cleaning the casing & slots with wire brush & washing with pressure water & shall be dried , rewinding the motor using required gauge of super enameled copper winding wire. Making the winding leak proof & taking out the electric connection with suitable size of submersible cable up to 03 Meter, Capacity of motor 10 HP complete all as specified and as directed .
Supply and fix parts of submersible pump set of capacity 10 HP complete all as specified and as directed.
i) Bearing bush Gun Metal
ii) Bearing bush SS with rubber
iii) Oil seal
iv) Thrust plate/thrust bearing set
v) Sand Guard
vi) CI Thrust Casing
vii) CI stage casing
viii). GM Bush
ix) Mild steel key for impeller
x) SS Studs with nuts
xi) CI Intermediate section
xii) SS coupling bush common for pump & motor with key
xiii) High Tensile steel shaft
Supply ,fixing ,testing and commissionng double flanged non-rising stem type cast iron sluice valve suitable for 100 mm dia bore pipe with hand wheel and suitable for pressure rating of PN :1.6duly drilled holes for fixing of nuts and bolts ,stem made of high tensile brass ISI marked and conforming to IS including rubber gasket ,nuts,bolts and washer complete all as specified and directed. Make : Kirloskar/L&T/zoloto
Supply ,fixing ,testing and commissionng double flanged non-rising stem type cast iron sluice valve suitable for 150 mm dia bore pipe with hand wheel and suitable for pressure rating of PN :1.6duly drilled holes for fixing of nuts and bolts ,stem made of high tensile brass ISI marked and conforming to IS including rubber gasket ,nuts,bolts and washer complete all as specified and directed. Make : Kirloskar/L&T/zoloto
Taking the water sample for semi under ground sump and submitted the sample of water to the Govt lab for testing of water ,Chlorine test and all chemical componants test complete all as specified and as directed
M&L in replacement of flat submersible 3 core 6 sqmm cable PVC insulated unsheathed multistranded copper conductor water proof suitable for submersible pump set complete all as specified and as directed.
M& L for servicing of RO plant( Acqua gurad type) of capacity 15 to 40 trs per hour incl replacement of following items :-
i) Carbon filter
ii) Sediment filter
iii) Membrane
iv) R O Pump
M& L for servicing of RO plant( Acqua gurad type) of capacity 50 to 120 ltrs per hour incl replacement of following items :-
i) Carbon filter
ii) Sediment filter
iii) Membrane
iv) R O Pump
Servicing of vertical pumpmotor set cap upto 7.5 HP ,oiling greasing and replacement of Mechanical seal suitable for the pumpset and of the same make as of existing
Servicing of vertical pumpmotor set cap 10 HP ,oiling greasing and replacement of Mechanical seal suitable for the pumpset and of the same make as of existing the following items:-
supply and fix in replacing of dosing pump incl. Replacing of PVC pipe of existing size and make
M& L for taking out pump motor set vertical cap 10 HP in RO plant ,,dismantling pump and motor separately , rewinding of electric motor with super enamelled copper wire of existing gauge after cleaning the slots properly and assembling and refixing in position and testing complete as directed by engineer in charge .
Cleaning of RCC underground sump of Size 10X10X10CFT complete by removing all scales, dirts, mud, chemical deposit etc from inner and outer chamber of tank as well as from the mouth of all circulating pipes connected with sump including scrapping out and throughly cleaning of internal surface/floor by using bleaching powder, soda ash etc complete all as dircted of specified by Engr-in-Charge.
Dismantling/Braking old unserciceable /dilapidated valve pit and Construction of new brick masionary valve pit of size1.2 X1.20 X 0.9 mtr with brick work 15 mm thick internal and external plaster in cm 1:4 inlcluding 25 X 25 X 5 mm MS angle iron frame all around the fixed point by means of 04 Nos hold fast 150 mm long made out of flat iron, 25 X 6 mm embedded in PCC block 1 : 2 : 4 type B1 including hinges welded with angle iron frame and MS cover 3 mm thick , MS handle of suitable locking arrangements and applaying two coat of synthetic enamal paint over a coat of red oxide primer including necessary excavation, removing/returning filling in soft/loose soil all as specified and directed by Engr-in-Charge
S&F in repair Non return valve cast iron of dia 100mm bore all as specified and as directed .
Servicing of R O PLANT WITH following work:- Overhauling , cleaning & servicing of filtration plant and iron removal plant by taking out all the filter media,cleaning,welding worn out MS pipe/Plate and internal threading where ever required the inside cell of filtration plant throughly by removing all scales /dirts/muds /chemical deposits etc & after drying the cell inside, apply painting in the complete inside cell with 2 coats of black bituminous paint(Suitable for drinking water), after painting, reset the seviceable and washed filter media and replace the unserviceable filter media with new media (supply only new filter media & strainer shall be measured separately under relevant item here-in-after) after completion of work, painting to outer surface including foundation, sluice valve, pipe etc with two coat of synthetic enamel paint with duly rubbing./cleaning of surfaces and writing the following:- (a) Filter Media cleaned/changed on ________ (b) Due on ______________
Cleaning of RCC under ground sump of 50000 Gallon capacity complete by removing all scales, dirts, mud, chemical deposit etc from inside the tank as well as from the mouth of all circulating pipes connected with RCC tank including scrapping out and throughly cleaning of internal surface/floor by using bleaching powder, soda ash etc complete all as dircted & specified by Engr-in-Charge. Note Proper care should be taken during cleaning so that no scales/dirts/deposits enters the supply/delivery line
Cleaning of RCC over head reservoir of 50000 Gallon capacity complete by removing all scales, dirts, mud, chemical deposit etc from inner& outer chamber of tank as well as from the mouth of all circulating pipes connected with RCC tank including scrapping out and throughly cleaning of internal surface/floor by using bleaching powder, soda ash etc complete all as dircted of specified by Engr-in-Charge. Note Proper care should be taken during cleaning so that no scales/dirts/deposits enters the supply/delivery line
M&L for defect rectification LTcable laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. including and additional excavation in normal alluvial strata required for exposing the cable fault, removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable of any size. The fault locating equipments will be brought to site within the hours of instruction from Engr-in-Charge as specified.
Supply and jointing straight through joint suitable for LT 415 Volt XLPE cable of size 70 to 120 Sq mm 3.5 core complete all as specified and as directed by Engineer-in-Charge.
Supply and jointing straight through joint suitable for LT 415 Volt XLPE cable of size 25 to 50 Sq mm 3.5/4 core complete all as specified and as directed by Engineer-in-Charge.
Supply, laying and testing in replacement cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 25 sqmm x 4 core complete all as specified and as directed. Note : Provision of suitable double crimpped lugs and glands deemed to be included in quoted rates.
Supply, laying and testing in replacement cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 95 sqmm x 3.5 core complete all as specified and as directed. Note : Provision of suitable double crimpped lugs and glands deemed to be included in quoted rates.
Supply, laying and testing in replacement cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 50 sqmm x 3.5 core complete all as specified and as directed. Note : Provision of suitable double crimpped lugs and glands deemed to be included in quoted rates.
Supply and fixed in repair, MCCB 250 Amp, 4 pole, microprocessor based, 36 KA including under voltage/ over voltage relay all as specified and directed.
Supply and fixed in repair, MCCB 200 Amp, 3 pole, microprocessor based, 36 KA including under voltage/over voltage relay all as specified and directed.
Supply and fixed in repair, MCCB 160 Amp, 3 pole, microprocessor based, 36 KA including under voltage/over voltage relay all as specified and directed.
S & F in replacement of Aluminium Cable lugs/Thimbles upto size 16 to 25 sqmm complete all as specified.
S & F in replacement of Aluminium Cable lugs/Thimbles of size 35 to 50 sqmm complete all as specified.
S & F in replacement of Aluminium Cable lugs/Thimbles of size 70 to 120 sqmm complete all as specified.
Disconnecting and taking down existing bus bars 4 wire system from LT panel board cleaning with CTC applying with becktol solution, removing old insulation and providing new heat shrink insulating sleeves, connecting and fixing in the same panel with new nuts, bolts, washers of suitable size complete all as specified and directed.
Disconnecting and taking out old existing worn out control wiring connections incl cable lugs of LT panel board of 4 wire system and supply and connect with new cable PVC insulated, stranded copper conductor 2.5 sqmm incl new copper lugs and nuts, bolts, washers complete all as specified and directed.
Disconnecting and taking out old existing worn out cable lugs, nuts, bolts, washers etc from LT panel board of 4 wire system (incomming and outgoing) and supply and connect with new aluminium lugs and nuts, bolts, washers etc complete all as specified and directed.
Taking out old existing worn out neoprene gasket from shutters of LT panel board single door /double doors or openable on both sides and supply and fix new neoprene gasket complete all as specified and directed.
M&L for Boring of holes under road, pavement,hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 100 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed.
Supplying and laying reinforced precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm
Laying only reinforced precast concrete cable cover taken out undeer item at sr no 33.
M&L Foundation for Tubular swaged pole type Pole including excavation , getting out, pole foundation with PCC type D2 1:4:8 (with 40 mm graded aggregate). Coping of pole with PCC type C1 1:3:6 ( with 20 mm graded agregate) and removing surplus soil to a distance n.exc 50 m and making good surface all as specified and directed by Engr-in-Charge.
M&L for painting of steel tubular pole including cable protection pipe and all iron parts of 9/11 mtr long pole complete with 2 coats of aluminium paint after cleaning all rust and dust and preparing surface with wire brush and including strips of white and blue colour of synthetic enamel paint up to the height of 1.5 mtr from the bottm of the pole complete all as specified and as directed. Make : Nerolac/Asian paint
Taking down of worn out PVC insulated copper cable 1.5 sqmm from street light fitting to junction box including conduit pipe complete all as specified and as directed.
M&L for wiring with two run single core PVC insulated, stranded unsheathed copper cable conductor size 1.5 Sqmm and drawing through and including S&F steel rigid conduit not less than 20mm dia and fixed on pole including 1.5 Sqmm PVC insulated unsheathed stranded copper conductor cable connected to earth including connecting to earth dolly complete all as specified and as directed.
Supply and fixing in repacement of weather proof street light junction box of size 300 x 200 x 105mm including MCB SP 6 Amps 10KA 'B' series and connecting terminals 4 way and fixing with street light poles using necessary MS clamps, nuts, bolts washers, lugs for incoming and out going cables, gland for cable etc of suitable size complete all as specified and as directed. Make : Hensel/Sintex/Universal Switch Gear control Note : The rates quoted are inclusive of provision and fixing of suitable lugs and glands for cable connection.
Supply and fix in replacement of automatic timer switch pole mounted enclosure consisting of ON/OFF switch based on LUX level power contactor 40 Amps, 10KA 'C' series 4 pole, MCB 40 Amps, TP - 03 Nos, enclosure made of rust proof, shock proof, conforming to IP -54 complete all as specified and as directed. Make : Kakatiya/Healer/Bajaj. Note: (i) Inlet/outlet connecting cable PVC insulated aluminium stranded conductor 6 Sqmm, 4 single core for incoming & outgoing up to 8 Mtr deemed to be included in the unit rate. (ii) Provn of glands and lugs shall be deemed to be included in the quoted rate.
Design Supply & Installation Of Complete Earthing Protection System With Copper Plate (92% Pure) Of Size 300mm x 300mm x 2 mm. Thick Buried Directly In Ground Connected To The Main Earth Lead Copper Strip 20mm x 3mm By Means Of 2 Set Accessories, Connected to Test Point Including Excavation in Rocky Type Of Soil, Providing Highly Treated Vegetable Soil, Earth Enhanced Compound Powder (ITPC EECP-15) Consists Of Copper Sulphate, Magnesium Sulphate, Graphite, Bentonite, Aluminium Silicate, Zinc Oxide & Iron Ore Alternate 15cm Layer Upto 15 Cm Above Top Edge Of Earth Plate, Construction Of PCC 1:2:4 Pit RCC Cover And Including Testing On Completion Complete In All Respect. (Note (i)Earth Lead Are Included Upto Test Point and on testing Earth Resistance should be Less Than 1 ohm) .(ii)Copper strip for interconnection for plate and taking out 2 Nos of copper strip of size 20 x 3mm from earth pit to test point for a distance not less than 7.5 Mtr.
M & L for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including using galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth plate surrounded by packed layer of char coal dust and common salt, 15cm thick all around bottom and top and watering pipe 20mm bore of GI light grade with funnel, wire mesh and 40 mm dia GI protection pipe medium grade all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point, main switch board and testing on completion including excavation, earth work concrete pit with 80mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 8mm dia @ 150C/C both ways and pit chamber in PCC 1:2:4 type B-1 with 2 Nos suitable lifting handles of 12mm MS bar complete all as specified.
Supply and filling river sand in trenches including spreading for cushioning of LT UG cable complete all as specified and as dirceted. Note : Punned down thickness shall be measured and paid .
M&Lin replacement FOR Grey powder coated die cast alumunium housing ,faceted anodised aluminium reflector , heat resistant toughened clear glass cover complete fittings with control ger box cat part no 161297 of BAJAJ or equivalent make phillips /CG
Supplying, installing, testing and commissioning of factory made LT cubical panel board, 440 Volts, 50Hz, 3 phase, 4 wire, outdoor type, weather, vermin and dust proof, front operated with adequate air ventilation at sides and back fabricated out of 3.15mm thick CRCA sheet with double door shutter and locking arrangements, cable trays, cable lugs etc., including provision for taking out incoming and outgoing cables duly marked with revetted letter plates of appropriate size for each feeder cable, danger board etc., suitable to accommodate and including the following mentioned fittings, floor mounted with suitable nut, bolts, washers etc. for grouting,all as specified and directed comprising of the following:-and inner shell shall be made out of 2 mm thick CRCA sheet duly compartmentalized for each control gear including front and back openable single door with fency lock (02 Nos for each compartment) with MC 100 pedastal for grouting in floor including foundation suitable for 3 phase 415 volts 50HZ comprising the following :-
(a) 300 Amps copper busbar for phases and 150Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulation in separate compartment.-01 set.
(b) MCCB 4 pole 200 Amps 35 KA-01 Nos (For incoming).
(c) MCCB 4 pole 63 Amps 25 KA-03 Nos (For Outgoing).
(d) MCB TPN 40 Amps 10 KA-02 No (For Outgoing).
(e) MCB SPN 16A 10KA-2 Nos
(j) Automatic timer switch current rating 40 Amp 4 pole 415 volt -01 No
(f) Digital multi function meter (Volt meter 0-500V,Ammeter 0-300A, frequency meter & power factor meter) of size 96mmx96mm with programmable CT ratio with back up protection by 2 A MCB SP.
(g) Indicating lamp 240 volts LED type - set of three
(h) Internal All links & control cable and inspection lamp -01
(j) CTs 400 / 5 Amps - set of three
Servicing of Airconditioning unit of 4.6 TR cap. ,cleaning with service chemical & air pressure the whole package unit inside, cooling coils ,indoor and outdoor units complete as per the direction of AGE E/M .
Testing of pipe line for any type of leakage using nitrogen gas at pressure of 20 kgs/ sqcm and 10Kgs /sqcm on low side and holding it for 24 hours and detecting the leakages and brazing the leaking points to stop leakages completely
Making the piping system vacuum and supply and charging the refrigerant gas R -410 a of required quantity as recommended by manufacturer to get sufficient cooling
Dismentling and taking out old burnt damaged coils of ceiling fan 1200/1400 mm sweep including scraping out old paint & cleaning all dust, making smooth surface with filler materials/ sand paper & painting with 1st grade quality synthetic enamel paint by spray & proper numbering including replacing of Twin flexible wire with new from ceiling rose to connector of fan complete -110 nos
Rewinding of ceiling fan 1200/1400 mm sweep with the same guage as per existing by new supper enameled copper wire including insulating material, heating, varnishing, reassembling, testing complete to the entire satisfaction of Engr-in-charge.
(c) S&F of following parts in replacement of unserviceable parts :-
Ball bearings ISI mark
Condenser 2.50 mfd
Split pin
Fan blades
Down rod
Servicing of DG sets of capacity 25 KVA TO 30 KVA INCL . minor repair and replacement of the following items
S & F in repair lubrication oil filter
S & F in repair by pass filter
Checking of hydraulic governer
Checking and toping up of coolant
S & F in repair fuel filter.
S & F in repair air cleaner element .
Cleaning radiator complete set
Engine Oil as per manufacturer specification and any other checking as per manufacturer instruction
Supply and fixing in replacement of AVR S/F VARIABLE SPEED DCDG suitable for DG set with input voltage range 415 Volt AC with neutral & Out put DC voltage 6 Amp 95 Volt DC suitable for DG set upto 31.25 KVA complete all as specified and directed by Engineer -in-charge.
Supply & fixing following items in replacement of DG Set of various capacity :-
i). Battery terminal, lug, bolts type suitable for heavy duty battery.
ii) Battery leads for copper conductor multiwired 16 Sqmm. 1.5 mtrs long
iii) Hinges for DG set door of any size, any type as required on site.
Dismantling/Taking out of radiator assembly to work shop for cleaning with compressed air ,pointing out leaking places and soldering carefully and refix in position after making it serviceable of DG 25/30 KVA
Dismantling of self starter, opening and segregating cleaning the serviceable parts for re-use, self starter servicing and greasing, re-assembling the self starter and replacement of following parts :- (i) Carbon bush (ii) Brass plunger (iii) Solenoid switch (iv)) Funnel coil (v) Body brass nut
S&F V belt for fan pulley (set of 2Nos) for DG set upto 25 KVA DG Set complete all as specified.
S&F V belt for alternator and water pump assembly for DG set upto 31.25 KVA complete all as specified.
S&F Fuel hose pipe from fuel filter to fuel pump for DG set upto 31.25 KVA, complete all as specified.
S&F Fuel pipe from fuel tank to fuel filter (transparent) for DG set upto 31.25 KVA, complete all as specified.
S&F fuel feed pump suitable size as required on site for DG set of capacity upto 31.25 KVA, complete all as specified and directed.
Supply and fixing of Fuse (HRC type) 63 amps, for DG sets of capacity 31.25 KVA complete all as specified and directed. Make: L&T/ABB/Havells
Supply and fixing battery 12 volts 60 AH ,ISI mark, make Exide
Taking down and dismantling HPSV/ LED type street light fitting for45/ 70/150/250 watt capacity of any make/type from pole/GI pipe unserviceable items to be kept in safe custody and taken as credit complete all as specified and directed.
Supply and Fixing LED street light luminaire IP-66 grade of proterction with 24 High power LED of 70/72 watt rating and extendable upto 48 watt rating with unique peanut lens to ensure uniform distribution complete all as specified and as directed . Make: CG or its equivalent in Wipro/Havells/Surya
Servicing, Oiling, Greasing and Cleaning of window type/ split type AC with high pressure pump of any capacity, checking of defects/ leaking and adjusting setting to work and testing and writing of MES no . complete all as specified & directed.by Engineer in charge .
M & L for cutting of suction line and discharge line tubing of AC, front scaled unit de-scaling, flushing out condenser and cooling coil thoroughly and reconnecting with the seal unit and charging of gas with required qty of refrigerant for 1.5 ton Split/W/T type AC
Ditto but all as per item No 42 described here-in-before but 2 ton capacity split type AC complete all as specifed & directed.
Supply & Fix spare parts of Air Conditioner etc.:- Replacement of burnt out transformer and S&F new transformer of 5 KVA voltage stabilizer complete all as specified and as directed.
M&L for replacement running capacitor of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
M&L for replacement of starting relay of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
M&L for replacement starting capacitor of existing make and capacity duly ISI marked for window type A/C 1.5 ton and split type AC 1/1.5/2 ton capacity complete all as specified and directed.
S&F in replacement of Electronic control (PCB) of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
Repair to compressor off size of existing makes and capacity for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
S&F Filter pad of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
S&F in replacement of Thermostat switch of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
S&F in replacement of of remote complete all as specified and directed.
Rewinding of blower motor of capacity 1.5/2.0 Ton complete all as specified & directed.
S&F in replacement of new rotary type AC compressor of window type/split AC with reconditioned & repaired compressor from authorized dealers of company in exchange including gas charging of capacity 1.5Ton capacity complete all as specified & directed.
S&F in replacement of new reciprocating type, AC compressor of window type/split AC with reconditioned & repaired compressor from authorized dealers of company in exchange including gas charging of capacity 2.0 Ton capacity complete all as specified & directed.
S&F in replacement of Evaporator coil complete all as specified and directed.
S&F in replacement of Suction/Discharge valve complete all as specified and directed.
S&F in replacement of Copper tube for 1.5 /2.0 Ton split AC 1/4 complete all as specified and directed.
S&F in replacement of Copper tube for 1.5 /2.00 Ton split AC 1/2 complete all as specified and directed.
S&F in replacement of Copper tube cover complete all as specified and directed.
S&F in replacement of insulation pipe size ¾” or 1” dia for split AC 1.5 / 2 Ton complete all as specified and directed.
S& F of outer unit incl compressor suitable for 1.5 ton split AC complete set incl testing make Logicool
S& F of inner unit suitable for 1.5 ton split AC complete set incl testing make Logicool
M& L for detection/ rectification of leakage of gas in the system and gas charging in the system with appropriate qty of gas incl uding testing for smooth functioning of water of capacity 60/80/120 ltrs complete all as specified and as direted . Note :-(i) Unserviceable condensing coil if reqd shall be measured and paid for separately .(ii) Cost of dismantling of unserviceable compressor if reqd deemed to be included in unit rate . (iii) compressor shall be measured and paid separately under respective items of sch 'A".(iv) Refilling & topping up refrigent (type & quantity as required on site is measured & paid separetely)
S&F compressor reciprocatint type (hermitecally) sealed for capacity 40/80 Ltrs water cooler complete all as specified and as directed.
S&F in repair of thermostat switch suitble for existing watre cooler anymake and capacity complete all as specified and directed. Make :Renutrol/Indofos/Annapurna
M&L in replacement of Starting relay andoverload relay suitable for existing size & make water cooler complete all as specified and directed. Make : Epcos/Asian
M&L in replacement of Starting capacitor for water cooler suitable for existing size& make water cooler complete all as specified and directed.
M&L in replacement of running capacitor suitable for existing size & make water cooler complete all as specified and directed.
M&L for dismantling of old defective condenser , fan motor of water coolerof any make and capacity and refixing and testing the same after rewinding with super enamelled copper wire
M&L servcing of Deep freezer any capacity and size by cleaning greasing including painting with one coat of super synthetic enameled paint including prepartion of surfaces complete all as specified and directed.
M&L of Gas Charging in deep freezer any make and capacity including testing of leakage complete all as specified and directed.
M/S Anand Enterprises
Saini Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .