Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 CrAccepted-AOC 16 A F 4 AMAR STAMBH PRESS COMPLEX M P NAGAR ZONE 1 BHOPAL 462011 | BHOPAL | MADHYA PRADESH | 462011 | ₹5.0 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹5.0 Cr+₹3.9 L (0.78%)Rejected-Finance 09 KAKWA DEPALPUR DISTRICT INDORE | INDORE | MADHYA PRADESH | 452001 | ₹5.0 Cr+₹3.9 L (0.78%) | L2 | Rejected-Finance EMD REFUND |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹5.6 Cr
EMD Value
₹5.6 L
Closing Date
7 Sept 2021, 5:30 pmClosed
P K Jain
engineering head office near tatpar petrol pump
CONSTRUCTION OF SHOPPING COMPLEX DASHERA GROUND HART BAZAR AND SPORT GROUND NAI BASTI NEELBADH WARD 26 ZONE 06 second call
2021_UAD_149135_2
2020202178
Open Tender
Civil Works - Buildings
Percentage
365 days
GROUND NAI BASTI NEELBADH WARD 26 ZONE 06
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹20,000
₹5.6 L
5 Jan 2022
24 Aug 2021
8 Sept 2021
24 Aug 2021
7 Sept 2021
24 Aug 2021
Amount
CONSTRUCTION OF SHOPPING COMPLEX, HAAT BAZAR AND SPORTS GROUND AT DASHERA GROUND NAI BASTI NEELBADH WARD 26 ZONE 06
Boring/drilling bore well of required dia perfectly vertical to receive casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire and running charges of all equipments, tools, plants and machineries required for the job, all complete as per direction of Engineer –in-charge, upto 90 metre depth below ground level. All types of soil:
Boring/drilling bore well of required dia perfectly vertical to receive casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire and running charges of all equipments, tools, plants and machineries required for the job, all complete as per direction of Engineer –in-charge, upto 90 metre depth below ground level. Rocky strata including Boulders.: 200 mm dia.
Boring/drilling bore well of required dia perfectly vertical to receive casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire and running charges of all equipments, tools, plants and machineries required for the job, all complete as per direction of Engineer –in-charge, upto 90 metre depth below ground level. Rocky strata including Boulders.: 200 mm dia.
Supplying, assembling, lowering and fixing in vertical position in bore well UNPLASTICIZED PVC MEDIUM WELL CASING (CM) PIPE OF REQUIRED DIA CONFORMING TO IS : 12818 INCLUDING REQUIRED HIRE AND LABOUR CHARGES FITTINGS AND ACCESSORIES ETC. ALL COMPLETE FOR ALL DEPTHS AS PER DIRECTION OF ENGINEER-IN-CHARGE. 200 MM DIA
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. CLAMP of recquired dia made of 100x10mm flat top of casing/housing pipe of tubewell as per is: 2800(part i) including necessary bolts and nuts of required size complete.
TUBE WELL PUMP SET L.S
Providing and erecting 12.5 mt high mast lighthing system with integral power tool, weight 340 kg having two section ho hot dip galvanizied material as per BSEN ISO 1461 thick of 3 mm dia 100 top and 360 bottom respectively. the mast shall be stress fitted at site with 250 mm over dynamic loading to without maximum wind pressure as per IS 875 part III and parmeters of structures and foundation desingn should be taken form wind tunnel test. the mast shall have lighting protection of GI single spike of designated length at top. the base inside compartment with double internal locak with adequate size of MCB mounted on PVC board complete with base palte of 25 mm thick 520 mm diameter and foundation bots having 4 nos bots of 24 mm daimeter (TS 600) anchor plate 445 PCD including accessories Viz (1) Lantern carriage of 50 OD ERW calss B pipe covered with PVC sleevs suitable to carry 250 KG load and upto 6 fitting symm metricaly (2) Traliling copper cable of 5x2.5 samm PVC insulated PVC shetehed (3)Double drum winch having gear ration5:3:1 oil bath (SAE/90/140)arrangement to be Type tested from NIT or IIT for (4) 2 nos stainless wire ropes 6 mm diam eter(7/19) oreaing load capacity 1450 kg x2 (5) integral power tool 3phase 0.75 HP to 1 HP 2 m/min single speed(6)Automatic astronomical timer panel complete in all respect of L&T, Indoasian, C&S, Havells make suitable for size of conta ctors for lighting and power tool, 2 nos. outgoing, reversing switch for motor.
Supply and installation of high efficiency LED flood light luminaries with high pressure die cast aluminum body (make embossing on body) with toughened glass / polycarbonate cover. The fitting should be IP66, IK-10, with power factor >0.9. The color temp of the LED should be 5000 K - 5700K with color rendering index >70. THD less than 20%. The total system output should be not less than 110 lumens/ watt & total wattage should not be more than 300W±5W. The LED fitting should have L70 life of more than 50000 burning hours at 35 degree ambient temp. Surge protection should be more than 4 KV internal and 10KVexternal. The LED should have individual optic lenses and bat wing photometry suitable for street light. The LED fitting should be provided with 2 year guarantee for free repairing/maintenance or replacement of LED light fitting, LED, driver, surge protector, toughened glass / polycarbonate cover etc. on stamp paper with service center details.LM79-80 report with batch no. of supply must be supply at the time of delivery,BIS certificate is must be submitted with catalogue/model no. Spare part list of driver, cover and LED must be submitted before supply. item and Philips, Crompton, Bajaj, Havells,Wipro,C&S, Keselec Schreder make
Supply and installation of high efficiency LED street light luminaries with high pressure die cast aluminum body (make embossing on body) with toughened glass / polycarbonate cover. The fitting should be IP66, IK-10, with power factor >0.9. The color temp of the LED should be 5000 K - 5700 K with color rendering index >70. THD less then 20%. The total system output should be not less than 110 lumens/ watt & total wattage should not be more than 150 w ± 5W. The LED fitting should have L70 life of more than 50000 burning hours at 35 degree ambient temp. Surge protection should be more than 4 KV internal and 10KVexternal. The LED should have individual optic lenses and bat wing photometry suitable for street light. The LED fitting should be provided with 2 years guarantee for free repairing/maintenance or replacement of LED light fitting, LED, driver, surge protector, toughened glass / polycarbonate cover etc. on stamp paper with service center details.LM79-80 report with batch no. of supply must be supply at the time of delivery, BIS certificate is must be submitted with catalogue/model no. Spare part list of driver, cover and LED must be submitted before supply. item and Philips, Crompton, Bajaj, Havells, Wipro,C&S, Keselec Schreder make
Supply and installation of high efficiency LED street light luminaries with high pressure die cast aluminum body (make embossing on body) with toughened glass / polycarbonate cover. The fitting should be IP66, IK-10, with power factor >0.9. The color temp of the LED should be 5000 K - 5700 K with color rendering index >70. THD less then 20%. The total system output should be not less than 110 lumens/ watt & total wattage should not be more than 90 w ± 5W. The LED fitting should have L70 life of more than 50000 burning hours at 35 degree ambient temp. Surge protection should be more than 4 KV internal and 10KVexternal. The LED should have individual optic lenses and bat wing photometry suitable for street light. The LED fitting should be provided with 2 years guarantee for free repairing/maintenance or replacement of LED light fitting, LED, driver, surge protector, toughened glass / polycarbonate cover etc. on stamp paper with service center details.LM79-80 report with batch no. of supply must be supply at the time of delivery, BIS certificate is must be submitted with catalogue/model no. Spare part list of driver, cover and LED must be submitted before supply. item and Philips, Crompton, Bajaj, Havells, Wipro,C&S, Keselec Schreder make
Supply and installation of automatic timer panel of powder coated sheet steel enclosuer surface mounted having astronomical time switch, contecter, MCCB , MCB, required all materials including PVC cables etc complete in all respect of Indoasian, Havells, Schneider, L&T make only with 24 months guarrantee
Supply and installation of automatic timer panel of powder coated sheet steel enclosuer surface mounted having astronomical time switch, contecter, MCCB , MCB, required all materials including PVC cables etc complete in all respect of Indoasian, Havells, Schneider, L&T make only with 24 months guarrantee
Supply and installation of LED tube light 20 watt complete Philips, Crompton, Bajaj, Havells,Wipro,C&S, Keselec Schreder make
Bidder Name
Amount
R K construction(GSTN-23AASFR2514G1ZA)
Technocraft Infrastructure(GSTN-23ABEPJ8137C1Z2)
R K construction
R K construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .