| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹9.7 LAccepted-AOC | L-1 | Accepted-AOC Being the lowest bidder | |
| 2 | L-2₹10.0 L+₹30,270 (3.11%)Rejected-AOC | L-2 | Rejected-AOC Not being the lowest bidder | |
| 3 | L-3₹10.7 L+₹98,895 (10.2%)Rejected-AOC | L-3 | Rejected-AOC Not being the lowest bidder | |
| 4 | L-4₹11.2 L+₹1.4 L (14.9%)Rejected-AOC | L-4 | Rejected-AOC Not being the lowest bidder | |
| 5 | L-5₹11.3 L+₹1.6 L (16.4%)Rejected-AOC | L-5 | Rejected-AOC Not being the lowest bidder |
Tender Value
Refer Docs
EMD Value
₹22,800
Closing Date
21 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL SANGRAM SINGH
GE Kaluchak Pin-900673 C/o 56 APO
PROVISION OF GEN SET OF 40 KVA AT KALUCHAK MIL STN UNDER GE KALUCHAK
2020_MES_373470_1
GE/KC/NIT-45/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹22,800
Yes
3 Oct 2020
31 Aug 2020
23 Sept 2020
31 Aug 2020
21 Sept 2020
16 Sept 2020
31 Aug 2020 - 15 Sept 2020
60 days
Amount
Supplying, installing, designing, testing, commissioning, interconnection to existing/ New LT panel, loading, transportation from manufacturers factory site and unloading at Kaluchak of Silent type Diesel Engine driven liquid cooled generating set having prime power rating of 40KVA, 415 volts, AC supply 50Hz, 3 phase 4 wire, 0.8 lagging power factor at NTP, speed 1500 RPM mounted on common base plate with close coupled with alternator and meeting the requirement of IS-4722/BIS specifications with CPCB approved accoustic enclosures fabricated out of CRCA sheet as per the manufacturer design and structural sheet metal base frame, sound proofing of enclosure is done with high quality foam confirming to IS-8183 of 25mm thickness and density 30 Kg/cubic metre complete in all respect including 1st fill of lubricating oil and foundation as per manufacturer recommendation :-
A) Diesel Engine: Diesel engine shall be the standard design of the OEM. It should be 4 stroke, water cooled, turbocharged as per OEM standard, electric start three cylinder inline assembly of minimum 56 BHP for giving a power rating in KVA at the load terminals of alternator at 1500 RPM at normal temperature and pressure (NTP) and confirming to BS 5514, BS 649, IS:10000 capable of taking 10% overloading for one hour after 12 hours of continuous operation confirming to the environment (protection Act 1986) (29 of 1986) and as ammended vide Gazette of India notifications Part II sections III sub section (I) dated 12 July 2004. The average load factor of the engine over a period of 24 Hrs shall be 0.85 (85%) for prime poweer output. The engine shall be fitted with all the required accessories: Make of Diesel Engine: Cummins/ Cotton Greaves/ Koel Green (Kirlosker)/ Caterpillar
(i) Dynamically balanced flywheel. (ii) Necessary flexible coupling and guard for Alternator and engine. (iii) Air cleaner (dry/oil bath type) as per manufacturer standard. (iv) Mechanical Governor control of class G2 and shall be self contained unit capable of monitoring speed. (v) Dry exhaust manifold with suitable exhaust residential grade slilencer to reduce noise level. (vi) Suitable self starter for 12V/24V DC. (vii) Battery charging alternator unit and voltage regulator suitable for starting batteries, battery racks, interconnecting leads and terminals. (viii) Battery charger in manual control panel to charge the battery from mains supply. (xi) Fuel pump with engine speed adjustment. (xii) All moving parts of the engine shall be mechanically guarded with MS mesh guard in such a manner that a human finger cannot touch any moving part.
(xiii) Radiator. (xiv) Any other item not mentioned /specified but is a standard design of the OEM. B) Fuel tank: Inbuilt fuel tank adequate capacity for 8 hours running with stop cock, drain plug, level indicator gauge and necessary fuel pipe manufactured out of 2mm thick MS sheet all as sper standard manufacturers design. C) Engine Instrument Panel: Engine control panel will be provided inside the acoustic enclosure. Panel will be fabricated out of 16 SWG CRCA MS sheet and powder coated after 7 tank treatment process with IP-53.The standard control panel consisting of control cubical fabricated of sheet steel construction indoor type inside the acoustic enclosure suitable for mounting accessories. Electronic engine management control panel fitted and having digital display of followings:- (a) Start/stop key switch (b) Hours meter (c) Lube oil pressure indication (d) Water temperature indication
(e) RPM indication (f) Engine hours indication (g) Battery charging indication (h) Low lube oil trip indication (j) High water temperature indication (k) Overspeed indication (l) Overload trip indication (m) MCCB for incoming as recommended by manufacturer--01 no set of busbar of suitable size - 01 no (n) Set of busbar of suitable size - 01 (o) DG set should be consist of a device though which dg set parameters can be remotly monitored through smart phone/laptop. D) Alternator : 40KVA at NTP, self excited screened protected, self regulated brushless alternator horizontal foot mounted in single bearing construction with following specifications: Rated pf 0.8 Lagging, Rated voltage 415volts, Rated frequenct 50Hz, no of phases-3,Enclosure SPDP, Degree of protection IP-23, Ventilation-Self ventilated air coooled, Ambient temperature 40 degree C,Insulation class H,Temperature rise within limits of class H insulation.
Voltage regulation = ±1%, Voltage Variation=±5%, Overload duration /capacity -10% for one hour in every 12 hours of continuous use. Frequency =±1% as defined by governor), Variation excitation - Self excited,Type of AVR-Electronic (Soft) Type of bearing and lubrication arrangement-Anti friction bearing with grease lubrication. Standard IS:4722 & IEC:34 as amended upto date. In the event of any fault due to over voltage /high winding temperature or an external fault, the AVR shall remove the excitation voltage to the Alternator. An emergency trip push button shall also be provided which is located outside the acoustic enclosure. Voltage dip shall not exceed 20% of the rated voltage for any step load or transuient load.The winding shall not develop hot spots exceeding safe limits due to imbalance of 20% between any two phases from no load to full load.The generator shall preferably be capable of withstanding a current equal to 1.5 times the rated current for a period of not more than 15 seconds.
The performance characteristics of the alternator shall be as below :- Efficiency at full load 0.8pf - not less than 90%, total distortion factor - Less than 3%, 10% overload-1 hour in every 12 hours of continuous use. 50% overload -15 seconds. Make of Alternator: Koel Green/ Stamford/ Leroy Summer/ Crompton Greaves E) Two nos of earth terminals on opposite sides with vibration proof connections non ferrous hardware etc with galvanised plate and passivated washer of minimum size 12mm dia hole shall be provided. F) Base Frame & Foundation : A PCC foundation platform shall be constructed using PCC 1:2:4, type B1 using 20 mm graded crushed stone agg of approx height 150mm above the finished Genset room floor level is required so as to provide levelled surface for placement of the accoustic enclosure. The length and width of foundations should be atleast 250mm more on all sides than the size of the enclosure as directed by Eng-in-charge. The quoted rate shall be inclusive cost of platform/ foundation work.
G) Starting System : The electric starting equipment will comprise of following :- i) 01 no of 12V DC battery as per manufacturer OEM recommendatation (88 AH ) maintenance free battery duly initial charged and battery lead of adequate capacity. Make of Battery -Koel Green/ Amaron/ Standard/ Furkkava/ Exide ii) Starter motor iii) Starter gearing iv) Start/ stop push button v) Inverter cum battery charger 500VA capacity suitable to work on 220 volts 50 hz AC supply system for charging of DG set batteries externally when DG Set is in off position. vi) Alternator/ Dynamo of suitable capacity to charge the batteries while DG set is running complete with auto cut all as per OEM recommendations shall be required at 24/12V DC and cable size of 50sqmm. The batteries shall be placed inside the acoustic enclosure.
The enclosutre shall be fabricated out of CRCA sheet of thickness not less than 1.6mm on the outside cover with inside cover having not less than 0.6mm thick perforated powder coated CRCA sheet.The hinge door shall be made from not less than 16 swg thick CRCA sheet and will be made airtight with neoprene gasket and heavy duty locks. All metal parts should be processed through 7 tank priocess.The enclosure should be powder coated green colour.The enclosure should accomodate the daily service fuel tank as per OEM recommendations capacity. There should be a fuel gauge which should show the level of fuel even when the dg set is not running .The gauge should be caliberated.The fuel tank should be filled from outside provided with a lockable cap.The batteries should be accomodated in the enclosure in the rack.The enclosure should be provided with high enclosure temperature safety device .
The acoustic lining shall be made of high quality insulation material like glass wool/ mineral wool/ rock wool with minimum of 50mm thick and 75Kg/cubic metre sound absorption as per standard designof OEM to reduce the sound level as per CPCB norms. The insulation material shall be covered with fine glass fibre cloth and would be supported by perforated MS sheet duly powder coated. The enclosure shall be provided with suitable size and no of hinged type doors along the length of the enclosure on each side for easy access inside the acoustic enclosure. Sufficient space will be provided inside the enclosure on all sides of the DG Set for inspection, easy maintenance and repairs.The MS base frame shall be provided having lifting facilities and predrilled foundation holes for installations on anti vibration mounting (AVM pads). MAKE OF CANOPY: Green field Enterprises/ Sudhir
K) Testing : All major equipments /items i.e engine & alternator in assembled condition electrical control panel etc shall be offered initial inspection at factoryu/ manufacturers work before dispatch at site of work kaluchak (Jammu). After inspection of these items shall be cleared for dispatch at site. After completion of the installation workin at site of work in all respects the contractor shall offer the DG set for testing, testing shall be carried out as under in the presence of IEM of department. The Contractor shall arrange OEM testing engineer on testing day without any extra charge to department and he himself be present or his authorise rep on testing day. All testing arrangements i.e resistive load, necessary cabling, T&P, fuel (diesel) etc required for testing shall be arranged by Contractor without any extra charged to department. The DG set shall be tested on resistive load of unity power factor for the rated KW rating.
During testing DG set shall be operated for 12 hours for DG set KW rating including one hour on 10% overload after continuous running of 12 hours. During the test all control and safety operations shall be checked and proper record will be maintained. L) Safety measures: All equipments shall incorporate suitable safety provisions to ensure safety of the operating personnel as per manufacturers standard practice.
Supplying, installing, testing and commissioning of LT panel outdoor type, cubicle type suitable for 3 phase 4 wire, 415 volts 50 Hz supply system factory made out of 3.15mm thick CRCA sheet for with front and rear openable provided with suitable gasket to make dust/vermin proof for IP-54 as per IS:13947 degree of protection, fault rating 50 KA/1Sec, including angle iron base frame of size 50x50x6mm thick for mounting the panel board at a height of 600mm from FFL and 300mm grouted in PCC foundation of 1:2:4 type B1 using 20mm graded crushed stone aggregate. The size of PCC foundation should be not less than (0.3x0.3x0.45M) for each leg complete all as specified the size of panel board shall be suitable for accomodating and including provision of following switchgears :-
A) INCOMING : (i) Incomer MCCB: 2 Nos - 100 Amps each four pole Icu=Ics=25 kA MCCB of ( Encapsulated roto operated double break contact design) (Uimp=8KV), Ics= 100%Icu MCCB with thermal magnetic based release having adjustable O/L (70%-100%), S/C (Isd 1.5-10xIr), neutral protection at N/2, N; & MCCB shall have voltage & current metering, extended rotary handle etc. (ii) On-Load 4 pole,100 A, 415V Panel mounted Change over switch confirming to IEC 60947-3/IS 13947-3. - 01 No (iii) Intelligent multifunction digital meter to read V, A, KVA, KWH, PF, Hz etc having RS 485 port and compatible to PC with modbus protocol with 3 Nos. resin cast CTs of 250 / 5 A class 1.0 accuracy and 15 VA burden. - 1 No. (EM6400NG)
(iv) Phase indication LED lamps with 2 Amps back up MCB, breaker ON indicating light with MCB, test terminal block set, fuses / MCBs, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required - 3 Nos B) BUSBAR : (i) TPN Copper bus bars (having 50% Neutral) of minimum of 200 Amps capacity with heat shrinkable coloured sleeves and including DMC / SMC bus bar supports at required intervals for complete cross section etc for withstanding fault level of 50KA for 1 Sec - 1 Set. C) OUTGOING : (i) 1 No - 100 Amps each four pole Icu=Ics=25 kA MCCB of ( Encapsulated roto operated double break contact design) (Uimp=8KV), Ics= 100%Icu MCCB with thermal magnetic based release having adjustable O/L (70%-100%),S/C (Isd 1.5-10xIr), neutral protection at N/2, N; & MCCB shall have voltage & current metering, extended rotary handle etc.
(ii) 3 Nos - 63 Amps each four pole Icu=Ics=25 kA MCCB of ( Encapsulated roto operated double break contact design) (Uimp=8KV), Ics= 100%Icu MCCB with thermal magnetic based release having adjustable O/L (70%-100%),S/C (Isd 1.5-10xIr), neutral protection at N/2, N; & MCCB shall have voltage & current metering, extended rotary handle etc.
Intergral LED security light luminaire 90W LED, 230 volts made up of pressure die-cast aluminium housing with toughned glass and high power LEDs and secondry lenses with IP66 protection, efficacy not less than 110 lumens per watt including 10 KV surge protection device, mounted on & including GI bracket made out of 40mm bore medium grade pipe of 1.20m length, bent to required shape, fixed on PCC/Steel pole with 02 Nos. clamps of flat iron (40 x 6mm), nuts, bolts and washers including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer and making connection with PVC copper conductor cable of appropriate size, complete all as specified & directed. Make. Crompton Greaves : Cat Part No. LSTP-90-CDL-M or equivalent model of make specified in List of Makes/ Manufacturers/ Producers here-in-after.
Pole mounted distribution box powder coated for street light made of CRCA sheet of 3mm thick, dust and vermin proof, outdoor type of size 300mm x 260mm x 165mm with arrangement of incoming and outgoing feeder comprising of TPN aluminium bus bar of capacity 32 Amp 415 volts, single MCB SP, 230 V, 10 Amp 10 KA (in accordance with IS/IEC 60898-1), fixed on porcelain insulators, making holes on strips for connecting cables, fixed to street light pole with and including 2 Nos MS clamps made of FI 25x5mm with nut, bolt & washer duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer , complete all as specified & directed. Note : Wiring from DB to light fitting shall be measured & paid saperately under respective item of Sch 'A'.
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 3 meter (BGL), connected to galvanized iron earth strip 32x6mm size by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 50mm bore 'light grade' galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt etc including connected to test point and testing on completion, complete all as shown in electrical plate No 3 of SSR Part-I 2009 & as directed.
Earthing complete with copper earth plate of 600x600mm 3.15mm thick electrode buried directly in ground (preferably in vertical position) earth pit not less than 2.25 metre below normal ground level with top edge of the earth plate not less 1.5 metre (BGL), connected to copper earthing strip 20mm x 3mm by means of connected with tinted copper bolt, nuts, check nuts and washers besides braising at all joints all as directed and connected to earth test point with and including necessary earth work in any type of soil, returning filling in, removal of surplus soil etc, filling adequate qty of charcoal dust, common salt, PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, 20mm bore 'medium grade' galvanized iron water tubing fixed with funnel and wire mesh and 40 mm bore “light grade” galvanized iron protection pipe for copper earthing strip 20mm x 3mm upto 5m length,
complete all as shown in electrical plate No 3 of SSR 2009 Part-I, connected to test point, complete all as specified and testing on completion. Notes : (i) The excess requirement (if more than 7.5 Mtr) of copper strip as for connecting upto the test point will be measured and paid separately. (ii) The excess requirement (if more than 7.5 Mtr) of GI protection pipe will be measured and paid separately. (iii).Testing of earthing is to be carried out by using earth tester & test result shall be submiited as directly duly signed by contractor.
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 70 Sqmm 3.5 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing after completion, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm 3.5 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing after completion, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out in any type of soil for foundation of pole, stay, taking up or laying of cable etc, complete all as specified & directed. Note : Due care shall be taken while deciding cable route for excavation. However any damage to Signal, BSNL, MES cable water/sewage pipe or any other service while excavation will be made good by the contractor and cost of the same for jointing material & labour is deemed to be included in the cost of excavation.
Sand cushioning to under ground cable, laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete punned to 18cm, complete all as specified and directed. Note:- Punned thickness of sand will be measured and paid.
Brick well burnt locally available sub class 'B' laid over sand cushioning for mechanical cable protection in trenches with width of brick perpendicular to the length of cable, complete all as specified & directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
Galvanised iron tube 40mm bore light grade (ISI marked) for cable protection to poles/under floor/under roads/alongwith walls complete including MS clamps of flat iron 25x3mm duly painted, GI nuts, bolts and washers & sealing of pipe ends with approved sealing compound, complete all as specified & directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required of copper strip of 20 x 3mm to connect earthpit to electrical equipment room, complete all as specified & directed.
On load change over switch in sheet metal enclosure, 100 Amps, 415 volts, 4 pole, modular type, positive isolation, door interlock & padlock facility, conforming to IS:13947 (Part-3); IEC:60947-3 including all connecting/ jointing materials, complete all specified & directed. Make. C&S Electric Cat Part No. ECSCS100DM4CO (NM Series) or equivalent model of make specified in List of Makes/ Manufacturers/ Producers here-in-after.
Maintenance free battery 12 volts,180 AH including flexible connecting copper cables of suitable rating complete as per latest IS specifications all as specified & directed. Make. Amaron/ Standard/ Furkkava/ Exide
Vishesh Engineers
GIANI ENGINEERING WORKS
Jiwan Singh
KAMAL CONSTRUCTION
L-7 Primewave Communications
MAMTA ENTERPRISES
Ashoka Engineers
M/S PRAJAPATI ENGINEERS
M/S ARUN ANAND
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .