Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹89.6 LAccepted-AOC | 1 | Accepted-AOC Eligible L1 bidder | |
| 2 | 2₹86.9 L+₹11.0 L (14.5%)Rejected-Finance | 2 | Rejected-Finance L2 tenderer |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
30 Jun 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CE MTS GTS
144, NPKRR Maaligai,Annasalai,Chennai-2
Regular and breakdown maintenance works in Electrical Division for a period of one year at Kuttalam GTPS
2023_EB_326423_1
SE/GTS/OT12/2023-24
Open Tender
Electrical and Maintenance Works
Works
365 days
Kuttalam GTPS
as per specification
3 documents required · 3 mandatory
₹0
₹90,000
Yes
6 Nov 2023
14 Jun 2023
1 Jul 2023
14 Jun 2023
30 Jun 2023
14 Jun 2023
14 Jun 2023 - 27 Jun 2023
Amount
Regular maintenance works in Electrical Division for the year 2022-23 for one year at KGTPS/Maruthur
Maintenance of Modules below 45kW rating -Routine (Once in 3months)
Maintenance of Modules above 45kW rating & LT Breaker- Routine (once in 3months)
Rectification of Light fittings below 4.5metres height (as and When necessity arises)
Rectification of Light fittings above 4.5metres height (as and When necessity arises)
Maintenance of LT motors below 25HP/18.5kW rating- Routine (once in 3 months)
Maintenance of LT motors above 25HP/18.5kW rating –Routine (once in 3 months)
Maintenance of HT motors Routine (Once in 3months)
Maintenance of 110KV isolators, PTs, CTs, CVTs, LASs etc.- Routine (once in 3months)
Maintenance of HT circuit Breakers (110KV, 11KV & 6.6KV) – Routine (once in 3 months)
Maintenance of Transformers- Routine (Once in 3 months)
Maintenance of Batteries (125V, 220V, 384V , PLCC, DG Set & FW pumps) (Once in a week)
Breakdown Maintenance of Intercom telephone (as and When necessity arises)
Extension of Temporary Supply (as and When necessity arises)
Painting of electrical equipments
Taking daily readings and monitoring the MCCs, Transformers, all breakers, isolators & parameters of various equipments and checking of Telephone as per walk down check list. (Daily)
Maintenance of EOT cranes & Electrical Hoist control panel (Once in 3 months)
Maintenance of PT cubicles( Once in 6 Months)
Electrical & Mechanical Isolation & Reconnection works below 18.5KW motors
Electrical & Mechanical Isolation & Reconnection works above 18.5KW motors
Assist the activity involved during startup of GTG/STG in forced outage / planned shutdown.
Maintenance of Quarters all electrical installation break down works including Fuse off call
Calibration of Voltmeters / Ammeters
Calibration of KW/KVAR/PF/KWH/Trivector meter/ Transducer
Calibration of Bimetallic, Electromagnetic & Static relays
Testing of Generator protection relays(Beck with M3425) and Transformer protection relays (DUO-Bios)
Testing of Other Numerical Relays
Testing of 11KV,6.6KV & 415V Breakers
Testing of 110KV Breakers
Cleaning and tightness checking control circuit in LT modules and fire detectors.
Cleaning and Tightness of GRP, GCP, RTCC, Fire panels, Switch Yard Mimic panel, SCADA panel, Tariff metering panel, Charger panel, EACP panel, VFD and UPS
Terminal tightness checking of 110KV,11KV,6.6KV & 415V CT & PT Secondary
Testing of Current Transformers
Testing of Potential Transformers
Testing of Power Transformers for Buchloz relay, PRD, PRV, MOG, OLTI, WTI
Testing of Power Transformer for DC resistance, OC/SC, Ratio test &trouble shooting
Lubricating cleaning, checking of control circuit of MOV's
Limit setting of torque, open & close limit switch of MOV's
Breakdown maintenance cost
Cleaning Checking and Calibration of field instruments as directed by the Engineer Incharge
Cleaning Checking and Calibration of Pneumatic Control valves as directed by Engineer Incharge
Cleaning Checking and Calibration field Solenoid valves as directed by the Engineer Incharge
Cleaning and Inspection of field instruments lines and attending defects in normal days
Cleaning and Inspection of all field instruments lines and attending defects in shutdown days
Inspection cleaning of equipments in CCR and maintain control supply to DCS panels in normal days
Inspection cleaning of equipments in CCR and maintain control supply to DCS panels in shutdown days
Dismantling refixing of Instruments lines for Mechanical Maintenance works as directed by Engineer
Breakdown maintenance includes problem solving and replacing of defective equipments
Cleaning, inspection and defective replacement of all Local Area Network Accessories
Removal and Re-erection of C&I instruments and its signal cables during major works.
Assisting Operator in Central Control Room for monitoring & recording important parameters and readings Assisting Operator for monitoring and recording important parameters and readings of Energy meters in Switchyard control room, switch gear room, CW MCC (once in a day)
Racking IN/OUT of 6.6 KV VCB, LT ACB at Switch Gear Room and removing of module fuses etc.,
Assisting the Main Control Room operators during Startup/ Shut down of the Unit.
Assisting Operator for monitoring and recording important parameters and readings at GBC, IA/ PA compressors, STG, GTG, BOP,CW areas and parameters like lube oil level, Bearing temperature etc., as directed by the operator (Once in each shift)
Checking for any abnormality in sound, leakage etc.,Checking in switchyard like, taking readings of SF6 Gas pressure etc., checking of breaker and isolator conditions, checking glow, Checking of Switchyard battery, station batteries and battery chargers etc., and taking Sp. gravity readings in the pilot cells. in each shift
Assisting the switch yard operations during feeder Issuing/Normalization of L.C
Checking of oil level in the transformers of GTG, STG, UAT and Station transformers and taking oil/Winding temp. Readings locally (Once in each shift).
Assisting Shift operators during routine changeover of equipments, Assisting during DG set trial runs , GT online water wash, GT pulse cleaning system start/stop etc.,
Other operations like opening / closing of valves like De-aerator, CRT quick filling valve opening /closing as instructed by the operators.
MS Contractors
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .