Loading…
Loading…
Tender Value
₹4.0 Cr
EMD Value
₹3.5 L
Closing Date
15 Jan 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
+ Capital Works)
S AND T
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB of SGCC, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
(a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b) (1)In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b)(2)In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing.
Defination of Similar Work :- Trenching, cable laying, location & signal foundation /erection/ termination / wiring in connection with any signaling work. O R Any Indoor or combined Indoor/ Outdoor Signaling work including Supply, Installation, testing and commissioning of relay interlocking (RRI/PI) system for passenger carrying lines.
6 conditions · 4 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The bid must comply technical conditions of tender.
Signalling work in connection with (1) Extension of UP & DN loop line to achieve 753 M CSR at Waghoda on Bhusawal division. (2) Various Signalling Works in connection with (TRR/CTR Work) on Bhusawal division.
BSL-N-SNT-33-2025-26~CR
BSL-N-SNT-33-2025-26
Open
Works - General
9 Months
Jalgaon, Maharashtra
₹0
₹3.5 L
15 Jan 2026
23 Dec 2025
1 Jan 2026
316 items across 5 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 34,38,951.45 | ||
| — | 1.00 | — | — | ||
| Supply of Relay Rack Assembly complete with scaffolding, fixtures and accessories including MS Bars for fixing of relay plug board, string rods, fuse strips with bracket, 11 Way Bus Bars with cover and mounting brackets, runway for cable/wires, frame, base assembly etc. Siemens type & as per extant practice on C. Rly. Typical part list as per Annexure-II and Rack arrangement as per Sketch no SK-727 and Rack plan as approved by Engineer incharge.(Inspection by Rites) | — | — | — | 37,246.13 | |
| — | 5.00 | — | — | ||
| Supply of Tag Blocks 200 / 160/120 way with polycarbonate cover as per IRS S 77- 2006 (Rev 1 ) RDSO DRG. NO SA 24751, SA 24752 & SA 24753 Requirement of each type shall be specified by Engineer incharge . (Inspection by RDSO) | — | — | — | 7,464.2 | |
| — | 1.00 | — | — | ||
| Supply of Tag Blocks 96/ 100 way with polycarbonate cover as per IRS S 77-2006 (Rev 1 ) Requirement of each type shall be specified by Engineer incharge .(Inspection by RDSO) | — | — | — | 1,579.52 | |
| — | 1.00 | — | — | ||
| Supply of Main Cable Termination rack complete with scaffolding, fixtures & accessories including square bars for mounting 8-way terminal blocks, ladder, string rods, frame, base assembly, insulators, J bolt, nut/bolts & fasteners, backelite sheet, etc. Siemens type and as per extant practice on Central Railway. Typical part list as per Annexure-III and rack arrangement shall be as per sketch No. SK-727 with latest alterations.(Inspection by RITES) | — | — | — | 32,079.26 | |
| — | 1.00 | — | — | ||
| Supply of PVC indoor cable 1 x 24 x 1 mm dia. Colour coding of insulation of inner Conductor shall be in eight colour viz Blue,Red,Grey,Green,Brown,Black, Yellow & white.conforming to IRS 76/89 (Amdt 3) or latest.(Inspection by RDSO) | — | — | — | 3,08,762.12 | |
| — | 2.00 | — | — | ||
| Supply of PVC Flexible Copper Cable, Single core, multi strand 1x2.5 sq mm(50 conductor each dia 0.25 + /- 0.01) as per specn IS 694/2010 with latest amendment. If any with insulation thickness of 0.70 mm nominal conductor resistance 7.98 ohms /km and test parameters are as per IRS (S)76/89 (Amdt .3).(Inspection by RDSO) | — | — | — | 94,063.54 | |
| — | 0.50 | — | — | ||
| Supply of PVC Flexible Copper Cable, Single core, multi strand 1x6 sq mm(84 conductor each dia 0.30 + /- 0.01) as per specn IS 694/2010 with latest amendment. If any with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms /km and test parameters are as per IRS (S)76/89 (Amdt .3).(Inspection by RDSO) | — | — | — | 48,332.71 | |
| — | 1.00 | — | — | ||
| Supply of PVC Flexible Copper Cable, Single core, multi strand 1x10 sq mm(80 conductor each dia 0.40 + /- 0.01) as per specn IS 694/2010 with latest amendment. If any with insulation thickness of 1.00 mm nominal conductor resistance 1.91 ohms /km and test parameters are as per IRS (S)76/89 (Amdt .3).(Inspection by RDSO) | — | — | — | 1,48,831.67 | |
| — | 0.50 | — | — | ||
| Supply of PVC Flexible Copper Cable, Single core, multi strand 1x16 sq mm(126 conductor each dia 0.40 + /- 0.01) as per specn IS 2465/1984 & IS:694/2010 with latest amendment. If any with insulation thickness of 1.00 mm nominal conductor resistance 1.121 ohms /km and test parameters are as perIRS (S)76/89 (Amdt .3).(Inspection by RDSO) | — | — | — | 1,10,747.67 | |
| — | 24.00 | — | — | ||
| Supply of low maintenance Lead Acid Secondary Cells 2V 80 AH. As per specn. IRS 88/2004 with latest amendment.(Inspection by RDSO) | — | — | — | 50,572.88 | |
| — | 10.00 | — | — | ||
| Supply of QNA1 -K AC immunized relay 8F-8B,24VDC along with plug board, retaining clip and connectors conforming to BRS:931A, & RDSO letter no STs/E/Relays/UEA/PI dated 30.05.97 Annexure-II IRS:S60,IRS:S34 & IRS:S23 .(Inspection by RDSO) | — | — | — | 43,258.78 | |
| — | 8.00 | — | — | ||
| Supply of QSPA1relay, 24VDC,Slow to pick up, 8F.4B along with plug board, retaining clip and connectors conforming to BRS:933A,IRS:S60,IRS:S34 & IRS:S23.(Inspection by RDSO) | — | — | — | 37,265.54 | |
| — | 6.00 | — | — | ||
| Supply of QTA2 AC immunised track relay, 9 Ohm,2F.1B, along with plug board,retaining clip and connectors conforming to BRS:939A, 966, & appendix F2, IRS:S34& IRS:S23. (Inspection by RDSO) | — | — | — | 24,434.98 | |
| — | 2.00 | — | — | ||
| "Supply of QBAT track Relay, AC immunised, 2F-2B contacts, 9 ohms. complete with plug board, retaining clip & connectors as per RDSO / SPN/84 ver 2.0 or latest.(Inspection by RDSO) " | — | — | — | 13,935.32 | |
| — | 6.00 | — | — | ||
| "Supply of Universal LED Lamp proving relay QECX61 relay, 4F-4B,AC conforming to BRS:941A STS/E/RELAYS/AC LIT LED SIGNAL/09-2002 ,Amdt.-1 (FOR ALL ASPECT ECR FOR AC LED SIGNAL) (Inspection by RDSO) " | — | — | — | 23,575.41 | |
| — | 6.00 | — | — | ||
| "Supply of Key Lock Relay working on 24V DC, AC immunized with different ward Combinations (Three ward plates to be supplied with each relay). RDSO /SPN / 219 / 2016 Version 1.0d1 (Inspection by RDSO) " | — | — | — | 41,325.59 | |
| — | 12.00 | — | — | ||
| "Supply of QNA1K relay 1000 ohm,6F/6B 24V DC as per BRS :931A, IRS:S60, IRS:S34 & IRS:S23 and RDSO spec. STS/ E/ Relays/UEA (PI) dtd.30.05.1997 Annexure II(Inspection by RDSO) " | — | — | — | 52,517.9 | |
| — | 100.00 | — | — | ||
| "Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92 " (a) "With holder 1.6 A (System, Rapid or Mainad Make). (Inspection by Consignee) " | — | — | — | 8,432.36 | |
| — | 20.00 | — | — | ||
| Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92 " (b) With holder 0.6 A (System, Rapid or Malnad Make) (Inspection by consignee) | — | — | — | 1,628.86 | |
| — | 300.00 | — | — | ||
| Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92 " (c) Without holder 1.6 A (System, Rapid or Malnad Make). (Inspection by Consignee) | — | — | — | 7,286.52 | |
| — | 100.00 | — | — | ||
| Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92 " (d) Without holder 0.6 A (System, Rapid or Malnad Make (Inspection by Consignee) | — | — | — | 2,428.84 | |
| — | 1.00 | — | — | ||
| "Resin cored wire as per specification No. IS:1921-1975 with Alloying element percentage as 63% SN (Tin) and / 37% Pb (Lead) with percentage of various impurities not exceeding the values Sb (Antimony) 0.2% maximum , Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly Al, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement. (Inspection by Consignee) " | — | — | — | 1,321.6 | |
| — | 5.00 | — | — | ||
| Lacing thread rolls, black, wax coated (100 mtrs) (Inspection by Consignee) | — | — | — | 348.97 | |
| — | 1.00 | — | — | ||
| "Fabrication and supply of Board made of White sunmica sheet over 12 mm thick particle/laminated/wooden board covered with 5 mm thick perspex transparent sheet in aluminium/ steel frame and Painting of SWR/Track insulation plan etc. (Inspection by Consignee) " | — | — | — | 7,705.94 | |
| — | 1.00 | — | — | ||
| Design,fabrication and supply of fuse Auto changeover system for 24 Nos of external non detorating Type fuses of G type fuses from 4 A to 10 Amp capacities generally used for point operation circuits.System shall have 6 cards with monitoring of 4 fuses in one card.As per RDSO spec.RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any. (Inspection by RDSO) | — | — | — | 42,745.67 | |
| — | 4.00 | — | — | ||
| Supply of Main Signal Post 140 mm outer dia 4.6 Mtr Length as per spec No IRS S 6/81 with latest amendments.(Inspection by Consignee) | — | — | — | 29,325.45 | |
| — | 2.00 | — | — | ||
| Supply of Main Signal Post 140 mm outer dia 5.6 Mtr Length as per spec No IRS S 6/81 with latest amendments.(Inspection by Consignee) | — | — | — | 19,484.32 | |
| — | 3.00 | — | — | ||
| Supply of Shunt Signal Post with Base (GI Pipe of 80 mm Dia of min. 1 meter length.). (Inspection by Consignee) | — | — | — | 8,583.82 | |
| — | 6.00 | — | — | ||
| Supply of Cast Iron Main signal surface base140 mm as per spec No IRS S-10 and Drg No 2011/M with latest amendments, with CLS ladder assembly complete for CLS signal 5.5/4.5/3.5 mtrs long as per R. No SA-23156(Adv),SA 23153(Adv) & SA 23150 (Adv) Alt. 1 respectively with latest Amendment as the case may be for CLS unit & signal back staging as per extant C.Rly practice .(Inspection by Consignee) | — | — | — | 57,191.4 | |
| — | 3.00 | — | — | ||
| Supply of Cast Iron Shunt signal surface base 80 mm as per spec.No IRS S 10 and Drg No 2011/M with latest amendment,as per RDSO Drg.No SA-23156/Drg.No RST/11413 as per extent C.Rly practice.(Inspection by Consignee) | — | — | — | 6,558 | |
| — | 9.00 | — | — | ||
| Supply of Signal No.plates. as per Drg No RST-11393/SK 842 (Inspection by Consignee) | — | — | — | 4,953.92 | |
| — | 2.00 | — | — | ||
| Supply of 2 aspect signal unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev 2.0 or latest complete to suit LED signals lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside . White pigment finish inside the 2 aspect unit to avoid any extra paint cost.(Inspection by Consignee) | — | — | — | 65,288.34 | |
| — | 4.00 | — | — | ||
| Supply of 3 aspect signal unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev 2.0 or latest complete to suit LED signals lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside . White pigment finish inside the 4 aspect unit to avoid any extra paint cost.(Inspection by Consignee) | — | — | — | 1,33,824.62 | |
| — | 3.00 | — | — | ||
| Supply of Shunt signal position light type FRP complete as per RDSO spn no RDSO/SPN/194/2006/Rev 2.0 or latest with off set bracket 3-1/2" to be fitted on 140 mm post drawing No. SA 23840 (Adv) Alt-2 for dependent type complete with signal unit bracket, terminals etc without lenses,lamp, lamp holder, and to suit LED signal lamp.(Inspection by Consignee) | — | — | — | 44,156.79 | |
| — | 6.00 | — | — | ||
| Supply of FIBRE GLASS INSULATING FIRE RETARDENT SHEET of 10 mm THICKNESS AS PER ISO:10192-1982,Dielectric strength -25KV/mm with glass content 25 to 34%, in standard size of 1.10x1.10Mtr.as per spec.No.IS:10192-1982 (Inspection by Consignee) | — | — | — | 33,552.18 | |
| — | 1.00 | — | — | ||
| Supply of One way Junction route indicator in FRP body without lenses and transformers as per RDSO spn RDSO/SPN/194/2006/Rev.2 .0 or latest complete and to suit LED signal lamp. (Inspection by Consignee) | — | — | — | 36,963.63 | |
| — | 10.00 | — | — | ||
| "Supply of Phenolic 10mm thick sheet, grade P3 in standard size of 1.22X1.22 Mtr as per spec. No IS 2036 of 1995."(Inspection by Consignee) | — | — | — | 55,397.81 | |
| — | 2200.00 | — | — | ||
| Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006(Rev - 2) with latest amendments and RDSO Drg.No.SA-23741 Alt.4., SA-23745 Alt 5, SA-23746, SA-23748 Alt -4 & SA-23756 Alt-3.(Inspection by RDSO) | — | — | — | 1,68,543.78 | |
| — | 80.00 | — | — | ||
| "Supply of cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4,SA- 23749 & Spec No IRS S 75/2006 with latest amendment. Fuse block shall be suitable for round head type voltage fuses."(Inspection by RDSO) | — | — | — | 13,753.44 | |
| — | 80.00 | — | — | ||
| Supply of round head type non detoriating type low voltage cartridge fuse as per Specn No IRS/S/78/92 with latest amendments 2A/4A/6A capacity.(Inspection by RDSO) | — | — | — | 5,919.53 | |
| — | 16.00 | — | — | ||
| Supply of Tik-tak, piano type switches,5 A (As per IS specification).(Inspection by Consignee) | — | — | — | 564.01 | |
| — | 16.00 | — | — | ||
| Supply of three pole plug and socket 5 Amp (As per IS specification).(Inspection by Consignee) | — | — | — | 3,897.29 | |
| — | 16.00 | — | — | ||
| Supply of Lamp 110V/24W,2 Pin for Loc.(Inspection by Consignee) | — | — | — | 383.72 | |
| — | 12.00 | — | — | ||
| Supply of Apparatus Case with godown locks with deatachable handle on both the doors. (a)Single Case as per Drg No SK 783-1&2. with latest alteration.(Inspection by RITES) | — | — | — | 2,02,833.06 | |
| — | 4.00 | — | — | ||
| Supply of Apparatus Case with godown locks with deatachable handle on both the doors. (b) Half Case as per Drg No SK 783-1&2. with latest alteration.(Inspection by RITES) | — | — | — | 54,248.77 | |
| — | 16.00 | — | — | ||
| Supply of earth electrode assembly as per Drg.No.CR/S&T/SK/815 (Inspection by Consignee) | — | — | — | 18,199.72 | |
| — | 1.00 | — | — | ||
| "Supply of Microprocessor based universal earth resistance sensing unit 12 channel AC/DC. as per RDSO/SPN/256/2002 with latest amendments.(Inspection by RDSO) " | — | — | — | 1,53,650.57 | |
| — | 24.00 | — | — | ||
| Supply of Track Lead Junction Boxes as per C.Rly Drg. No.RST 11509 made from fiber glass along with terminal blocks.(Inspection by Consignee) | — | — | — | 26,537.37 | |
| — | 8.00 | — | — | ||
| Supply of B type choke to specn.No.IRS.S.65/83 (Amdt -3) with latest amendments. (Inspection by RDSO) | — | — | — | 30,946.93 | |
| — | 8.00 | — | — | ||
| Supply of adjustable Track Feed Resistance disc type 7.5/15/30 ohms as per RDSO Drg. No. SA 20161-66/M (Adv) with latest amendments (with Phenolic moulded base).(Inspection by RDSO) | — | — | — | 10,872.93 | |
| — | 8.00 | — | — | ||
| Supply of Track feed battery chargers, 110V AC input 2, 4 to 6 V DC Output to Specn.No.IRS.89/2013/Ver 1.0 with latest amendments. Charger shall be suitable for charging 80 AH battery.(Inspection by RDSO) | — | — | — | 20,513.68 | |
| — | 50.00 | — | — | ||
| Supply of Channel Pins single groove, galvanised, 7 mm suitable for 4mm dia bonding wire as per spec No IRS S 17-75 Revision 3 .(Inspection by Consignee) | — | — | — | 106.04 | |
| — | 160.00 | — | — | ||
| Supply of PVC jacketed wire rope for Track Lead connections. PVC jacketed wire rope should be of Galvanised steel wire rope 6 mm dia (6x19 stranded wire with steel core of 6 mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1984 Reaffirmed 2001 and steel wire rope as per IS:2266:2019. Reclaimed or recycled material should not be used.(Inspection by Consignee) | — | — | — | 8,827.39 | |
| — | 5.00 | — | — | ||
| Supply of 8 SWG GI wire (4mm dia) suitable for track circuit rail bonding .As per IRS specification S:13-62 (Inspection by Consignee) | — | — | — | 458.02 | |
| — | 4.00 | — | — | ||
| Supply of Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes.Consignee inspection under manufacturer certificate.(Inspection by Consignee) | — | — | — | 1,197.07 | |
| — | 12.00 | — | — | ||
| — | — | — | 4,283.28 | ||
| — | 12.00 | — | — | ||
| — | — | — | 1,03,458.72 | ||
| — | 60.00 | — | — | ||
| — | — | — | 65,162.13 | ||
| — | 90.00 | — | — | ||
| — | — | — | 30,522.67 | ||
| — | 2400.00 | — | — | ||
| — | — | — | 5,21,995.95 | ||
| — | 500.00 | — | — | ||
| — | — | — | 2,22,757.99 | ||
| — | 720.00 | — | — | ||
| Supply of Modular Terminal block of 2.5 sqmm 2 IN 2 out type disconnect type terminal along with as per RDSO Specn.No.RDSO/SPN/189/2004 Rev 3.0. The current capacity of 16 Amps & more,The terminal should have marking at centre to view description from front.Material to be procured from RDSO approved firm only.(Inspection by RDSO) | — | — | — | 88,972.78 | |
| — | 8.00 | — | — | ||
| Supply of DIN channel for the terminals 1 Mtr each(Inspection by Consignee) | — | — | — | 1,829.37 | |
| — | 66.00 | — | — | ||
| Supply of End plates for modular terminal block (Inspection by Consignee) | — | — | — | 1,628.8 | |
| — | 66.00 | — | — | ||
| Supply of End clamp for modular terminal block (Inspection by Consignee) | — | — | — | 1,170.59 | |
| — | 4.00 | — | — | ||
| Supply of marker card as per customer spec(10x10) (Inspection by Consignee) | — | — | — | 353.71 | |
| — | — | — | 10,02,453.29 | ||
| — | 87.00 | — | — | ||
| Supply of QTA2 AC immunised track relay, 9 Ohm,2F.1B, along with plug board,retaining clip and connectors conforming to BRS:939A, 966, & appendix F2, IRS:S34& IRS:S23 (Inspection by RDSO) | — | — | — | 3,00,175.5 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .