| 1 | 1₹8.1 LAccepted-AOC PLOT NO 733 SPRINGVILLA GREEN HOUSE NO 2 BIJIPUR TAMANDO BHUBANESWAR 752054 | KHORDHA | ODISHA | 752054 | ₹8.1 L | 1 | Accepted-AOC amount excluding gst |
| 2 | Rejected-Technical NEW DELHI | - | - | Rejected-Technical technically rejected as recommended by the commiittee |
| 3 | Rejected-Technical | - | - | Rejected-Technical technically rejected as recommended by the commiittee |
| Sl No | Description | Qty | Unit | UNIVERSAL PROJECT AND MAINTENANCE L1 |
|---|---|---|---|---|
| 1.00Cat (A) - Filtration of transformer oil at site with high vacuum machine including testing of breakdown value and acidity of oil and topping of oil after filtration, all as per relevant IS specifications and as per instructions of IOP-EIC. 1. The filtration machine should accompany with oil testing kit to test the dielectric strength of the transformer oil at regular intervals/ as per requirement. 2. Before setting up the oil filtration machine in operation it is to be ensured that the residual oil in the machine is clean & pure and have adequate dielectric strength. 3. The dielectric strength of the transformer oil is to be recorded before starting of the oil filtration and after the filtration. 4. Connection points of the transformer is to be checked and tightened if required. 5. All gasket points/ linings are to be checked and tightened to stop the oil leakage. If anywhere gasket needs to be replaced same is to be intimated to IOP EIC for necessary steps. | ||||
| 1.01 | 750KVA, 33/0.433KV, CGL make Transformer with indoor type HT bushing, off load tap changer | 1 | Job | 12,000 ₹12,000 |
| 1.02 | 01MVA, 33/0.433KV, CGL make Transformer with outdoor type HT bushing, off load tap changer | 1 | job | 15,000 ₹15,000 |
| 1.03 | 01MVA, 33/0.433KV, CGL make Transformer with outdoor type HT bushing and on load tap changer (OLTC) | 2 | jobs | 15,000 ₹30,000 |
| 2.00 | Supply of new transformer oil (EHT grade) as per IS: 335- 1972 in non-returnable sealed drums. Make: Transol/ Savita or approved equivalent of the same. | 400 | Ltr. | 120 ₹48,000 |
| 3.00Painting of the transformer & associated switch gears: The scope of this job includes the following points: 1. The complete body of the transformer is to be cleaned free from oil and dirt with the help of moping cloth and cleaning agents if required. 2. All roughness and oxidized points are to be cleaned with the help of suitable emery cloths with precaution and without causing any damage to the body of the transformer. 3. All Insulators, name plates and nomenclatures are to be covered properly before application of paint to protect it from paints. 4. Two coats of red oxide/ primer is to be applied through fine nozzle, compressed air and spray painting machine. 5. Two coats of suitable synthetic enamel paint is to be applied through fine nozzle, compressed air, spray painting machine 6. Shade of the paint should match with the earlier paint of the same equipment’s. 7. The job has to be carried out with minimum shutdown of the supply system. For shutdown of any system it has to be informed 2days prior to the scheduled date to the EIC-IOP. | ||||
| 3.01 | 750KVA, 33/0.433KV, CGL make Transformer with indoor type HT bushing, off load tap changer (Approximately 60Sq mtr.) | 1 | job | 20,000 ₹20,000 |
| 3.02 | 01MVA, 33/0.433KV, CGL make Transformer with outdoor type HT bushing, off load tap changer (Approximately 75 Sq. mtr.) | 1 | job | 20,000 ₹20,000 |
| 3.03 | 01MVA, 33/0.433KV, CGL make Transformer with outdoor type HT bushing and OLTC (Approximately 80Sq. Mtr.) | 2 | jobs | 20,000 ₹40,000 |
| 3.04 | 30VA, 25/5, CT (Current Transformer) connected in circuit and mounted on 33KV Structures at a height of 20 to25ft (approx.).
(Approximately 1.5Sqmtr.) | 15 | jobs | 1,500 ₹22,500 |
Tender Value
₹8.3 L
EMD Value
₹41,252
Closing Date
10 Dec 2025, 6:00 pmClosed
REGISTRAR
Institute of Physics,PO-Sainik School,Bhubaneswar
Transformer Oil Filtration, Painting, Repair and Associated Works of 33KV Substation
2025_IOPB_885996_1
NIT/IOP/118/2025-26
Open Tender
Electrical Works
60 days
Institute of Physics, PO-Sainik School, Bhubaneswar
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹41,252
Yes
27 Apr 2026
19 Nov 2025
11 Dec 2025
19 Nov 2025
10 Dec 2025
19 Nov 2025
19 Nov 2025 - 4 Dec 2025
Cat (A) - Filtration of transformer oil at site with high vacuum machine including testing of breakdown value and acidity of oil and topping of oil after filtration, all as per relevant IS specifications and as per instructions of IOP-EIC. 1. The filtration machine should accompany with oil testing kit to test the dielectric strength of the transformer oil at regular intervals/ as per requirement. 2. Before setting up the oil filtration machine in operation it is to be ensured that the residual oil in the machine is clean & pure and have adequate dielectric strength. 3. The dielectric strength of the transformer oil is to be recorded before starting of the oil filtration and after the filtration. 4. Connection points of the transformer is to be checked and tightened if required. 5. All gasket points/ linings are to be checked and tightened to stop the oil leakage. If anywhere gasket needs to be replaced same is to be intimated to IOP EIC for necessary steps.
750KVA, 33/0.433KV, CGL make Transformer with indoor type HT bushing, off load tap changer
01MVA, 33/0.433KV, CGL make Transformer with outdoor type HT bushing, off load tap changer
01MVA, 33/0.433KV, CGL make Transformer with outdoor type HT bushing and on load tap changer (OLTC)
Supply of new transformer oil (EHT grade) as per IS: 335- 1972 in non-returnable sealed drums. Make: Transol/ Savita or approved equivalent of the same.
Painting of the transformer & associated switch gears: The scope of this job includes the following points: 1. The complete body of the transformer is to be cleaned free from oil and dirt with the help of moping cloth and cleaning agents if required. 2. All roughness and oxidized points are to be cleaned with the help of suitable emery cloths with precaution and without causing any damage to the body of the transformer. 3. All Insulators, name plates and nomenclatures are to be covered properly before application of paint to protect it from paints. 4. Two coats of red oxide/ primer is to be applied through fine nozzle, compressed air and spray painting machine. 5. Two coats of suitable synthetic enamel paint is to be applied through fine nozzle, compressed air, spray painting machine 6. Shade of the paint should match with the earlier paint of the same equipment’s. 7. The job has to be carried out with minimum shutdown of the supply system. For shutdown of any system it has to be informed 2days prior to the scheduled date to the EIC-IOP.
750KVA, 33/0.433KV, CGL make Transformer with indoor type HT bushing, off load tap changer (Approximately 60Sq mtr.)
01MVA, 33/0.433KV, CGL make Transformer with outdoor type HT bushing, off load tap changer (Approximately 75 Sq. mtr.)
01MVA, 33/0.433KV, CGL make Transformer with outdoor type HT bushing and OLTC (Approximately 80Sq. Mtr.)
30VA, 25/5, CT (Current Transformer) connected in circuit and mounted on 33KV Structures at a height of 20 to25ft (approx.). (Approximately 1.5Sqmtr.)
100VA, 33KV/rt3/110/rt3, PT (Potential Transformer) connected in circuit and mounted on 33KV Structures at a height of 20 to 25ft (Appx) (Approximately 0.7Sqmtr.)
1250A/1600A, 36KV, CG make VCB connected in circuit (Approximately 06 Sq. mtr.)
Control/ Gear Boxes of the Isolators/AB Switches of 33KV Substation. Size 0.6mx0.5mx0.4m.
Control/ Gear Boxes of the Earth Switches of 33KV Substation: Size- 0.4mx0.2mx0.3m.
Supply and Painting of the following electrical equipment’s after thorough cleaning of the surface by wire brush, Emery cloth etc. After cleaning one coat of red oxide primer and two coats of Synthetic enamel paint is to be applied on the surface of the equipment’s by suitable paint brush. All name plates and nomenclature is to be covered properly before application of paint to protect it from paints. The make of paints is Asian or Berger make Synthetic enamel paint or approved equivalent of the same. Shade of the paint should match with the earlier paint of the same equipment’s. All as per the instructions of EIC, IOP
MS, Chequered cover plates both sides on the cable trench of the 33KV Substation.
18 nos. of Earth pit covers with the support angles
L.T. panels/Distribution Boards in colony/ Main LT Panel & DG room Shutters/ Transformer yard gates etc. (one coat of red oxide primer and two coats of Synthetic enamel paint as per requirement)
Supply & Painting of the 33KV switch yard equipment’s such as structures, gate and fence by suitable paint brush one coat of red oxide primer and 2 coats of high build high gloss Aluminum enamel paint of 20 micron DFT (Dry film thickness) of Berger/ Asian/Shalimar/Nerolac make as per BIS: 2339 using appropriate thinner as recommended by manufacturer & paint shall be of approved make as per specification. The scope of job includes surface preparation, removing rust by wire brush/ emery cloth, brushing and cleaning for effective execution of work etc complete all as per the instruction of EIC, IOP. The job has to be carried out with minimum shutdown of the supply system. For shutdown of any system it has to be informed 2days prior to the scheduled date to the EIC-IOP. Any type shutdown from supply end (i.e. CESU) to carry out the above work if required is to be availed with due permission from IOP and all liaison work with CESU is to be carried out by the Contractor within the scope of this work.
New 33KV switch yard Main gate, DP Structures, Support Angles, Cable trays etc.
Wire net fencing of the New 33KV switch yard and the Switch yard near overhead water tank including support MS Angles (all sides), height of the fence is 2.5 mtr.
Barbed wire fencing of the old 33KV switch yard including support MS Angles (all sides), height of the fence is 2.5 mtr.
Old 33KV switch yard and the Switch yard near overhead water tank: Main gate, Four pole Structures, DP Structures, Support Angles etc.
Cleaning of the Switch Yard by uprooting the grass, weeds and creepers etc.
Supply, Installation, Testing and commissioning of Resin Cast CT, suitable to mount on 2x50 x 10 mm copper bus bars in IOP 33KV LT Panel, 15VA, Class-1 accuracy, Make: AE/ Kappa or approved equivalent of the same in the existing 33KV substation LT panel. The followings are in the scope of work: 1. All the existing CT with wiring to be removed and handed over to IOP, EIC. 2. The new CT is to be fixed on the bus bars properly. 3. It is preferable to carry out this job through a reputed panel manufacturer for proper execution.
CT Ratio 600/5 Amp (320KVA DG panel)
CT Ratio 400/5 Amp (320KVA DG panel)
Supply, Installation, testing & Commissioning of Concealed Hinges in existing electrical panels as a replacement of the existing broken hinges. The scope of job involves the following: 1. Removal of existing hinges from the panel & panel door and to hand over the same to IOP EIC. 2. All type of welding, cutting and drilling etc. required for the same is included in the scope of job. 3. Any type of hardware like nuts and bolts required for the same is included in the scope of this job.
Supply, Installation, Testing and commissioning of Electrical Panel locks in existing electrical panels as a replacement of the existing broken locks. The scope of job involves the following: 1. Removal of existing locks from the panel & panel door and to hand over the same to IOP EIC. 2. All type of welding, cutting and drilling etc. required for the same is included in the scope of job. 3. Any type of hardware like nuts and bolts required for the same is included in the scope of this job.
Cat (B) - Buy Back Items
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.19 MB
TechnicalspecificationOIL.pdf
Tender Documents • 1.07 MB
BOQ_931276.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid