Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹26.9 L+₹1.5 L (6.06%)Rejected-Finance C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹30.3 L+₹4.9 L (19.4%)Rejected-Finance LODHI NAGAR NEAR TEACHERS COLONY GALI NO 4 MAHOLI ROAD MATHURA U P 281004 | MATHURA | MATHURA | UTTAR PRADESH | 281004 | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹31.5 L+₹6.1 L (24.2%)Rejected-Finance | L4 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 5 | L5₹37.7 L+₹12.3 L (48.5%)Rejected-Finance | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
7 Sept 2021, 6:00 pmClosed
GE EAST MATHURA
Garrison Engineer East Military Engineer Services Mathura Cantt Mathura 281001
REPAIR TO ELECTRIC WATER HEATERS AND SOLAR WATER HEATERS AND CONNNETED WORKS AND REPAIR/MAINT OF INTERNAL ELECTRIFICATION, SUBMIAN WIRING, SERVICE CONNECTIONS AND CONNECTED E/M ITEMS IN THE AOR UNDER GE (EAST) MATHURA
2021_MES_467117_1
8200-1230/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
MATHURA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE EAST MATHURA
₹86,000
5 Oct 2021
11 Aug 2021
9 Sept 2021
11 Aug 2021
7 Sept 2021
26 Aug 2021
11 Aug 2021 - 31 Aug 2021
Amount
Inspecting the serviceability state of 25 Ltrs capacity Geyser parts at site and carry out complete descaling of all parts such as inner tank, geyser assembly, thermostat, heating element etc with cleaning rod,brush or cleaning solution (chemical) or any other suitable method and reassemble the geyser complete including replacing the unserviceable parts with new parts complete :- Note:- Replacement of any unserviceable part shall be deemed to tbe included in the unit rate quoted. Howerver, cost of any unserviceable items replaced shall be measured and paid as supply only under relevant item here-in-after.
Supply only inner tank for geyser cap 25 ltr of Steel sheeting for geyser as per existing complete all as specified and directed by Engineer-in-Charge.
Supply only outer body/cover suitable for 25ltr cap geyser made out of mild steel pre-treated and stove enamelled sheet of 22 SWG complete with top and bottom cover, rubber gasket, stead screw for fixing the top and bottom cover to outer body easing including two coat of white synthetic enameled paint over one coat of red oxide primer complete all as directed by Engineer-in-charge.
Supply only in replacement of unserviceable heating element, 240 Volt with rubber washer ('O' ring) cap 1.5 KW. (round or triangular) any type complete all as specified and directed by Enginner-in-Charge. Make:- Theeta/Micron/Racold/Daspass/Bajaj or As per sample
Supply only Geyser water assembly of Stainless steel heavy duty suitable for 25 Ltr electric water heaters. Make-Bajaj/Recold or as per sample /installed at site
Supply only thermostat 30°C to 70°C, ISI marked, rated current 10-15 Amp, 230 Volts suitable for Geyser 25 Ltr complete all as specified and directed by Engineer-in-charge. Make:- Bajaj/Venus/Theeta or as per sample /installed at site
Supply only Safety plug 15mm (brass) for geyser cap 25 Ltr complete all as specified.
Supply only safety Valve for Suitable Cap of 25/50 Ltr cap Geyser complete all as specified and directed.
Supply only Indicator bulb neon round/square type single phase 230 Volt complete all as specified.
Inspecting the serviceability state of 50 Ltrs capacity Geyser parts at site and carry out complete descaling of all parts such as inner tank, geyser assembly, thermostat, heating element etc with cleaning rod,brush or cleaning solution (chemical) or any other suitable method and reassemble the geyser complete including replacing the unserviceable parts with new parts complete :- Note:- Replacement of any unserviceable part shall be deemed to tbe included in the unit rate quoted. Howerver, cost of any unserviceable items replaced shall be measured and paid as supply only under relevant item here-in-after.
Supply only inner tank for geyser cap 50 ltr of Steel sheeting for geyser as per existing complete all as specified and directed by Engineer-in-Charge.
Supply only outer body/cover suitable for 50 ltr cap geyser made out of mild steel pre-treated and stove enamelled sheet of 22 SWG complete with top and bottom cover, rubber gasket, stead screw for fixing the top and bottom cover to outer body easing including two coats of white synthetic enameled paint over one coat of red oxide primer complete all as directed by Engineer-in-charge.
Supply only heating element with complete assembly set with rubber washer ('O' ring) cap 2.0 Kw (round or triangular) for ESSCO geyser of capacity 25 Ltrs complete all as specified and directed by Enginner-in-Charge. Make:- Theeta/Micron/Racold/Daspass/Bajaj or As per sample
Supply only thermostat 30°C to 70°C, ISI marked, rated current 10-15 Amp, 230 Volts suitable for Geyser 50 Ltr complete all as specified and directed by Engineer-in-charge. Make:- Bajaj/Venus/Theeta or as per sample /installed at site
Supply only Geyser water assembly of Stainless steel heavy duty suitable for 50 Ltr electric water heaters. Make-Bajaj/Recold or as per sample /installed at site
Supply only Safety plug 15mm (brass) for geyser cap 50 Ltr complete all as specified.
Supply only safety Valve for Suitable Cap of 50 Ltr cap Geyser complete all as specified and directed.
S&F in repair of MS top or bottom cover of 22 gauges, ISI marked complete suitable for 50 Ltr capacity electric water heaters. Make-Recold/Bajaj/Ritz or equivalent.
S&F in repair of MS top or bottom cover of 22 gauges, ISI marked complete suitable for 25 Ltr capacity electric water heaters. Make :- Recold/Bajaj/Ritz or as per sample /installed at site
Supply and Fixing in replacement of unserviceable PVC flexible inlet outlet connection 15 mm dia, 45 cm long with brass nuts bolts and washers etc complete all as specified.
Supply and Fixing in replacement of unserviceable PVC flexible inlet outlet connection 15 mm dia, 60 cm long with brass nuts bolts and washers etc complete all as specified.
Supply only in replacement of unserviceable/ damaged glass wool complete all as specified.
M&L for grouting the bolt of size 6"x1/2" with nut in wall in repairs for fixing the geysers complete and as directed by Engineer-in-Charge.
M&L for painting of electric water heater 50 Ltr capacity with one coat of super enamel paint of white colour with spray machine including preparation of old painted surfaces including writing of MES No complete.
M&L for painting of electric water heater 25 Ltr capacity with one coat of super enamel paint of white colour with spray machine including preparation of old painted surfaces including writing of MES No complete.
S&F in replacement of unserviceable plug and socket in sheet metal enclosures with two pin and earth plug and socket complete with and including MCB SP 20 Amps 240 volts heavy duty etc complete all as specified and as directed by Engineer-in-Charge
S&F in replacement of unserviceable plug top 3 pin 15 Amp for geyser conncetion complete all as specified and directed by Engineer-in-charge..
S&F in replacement metal clad plug top 3 pin 15 Amp for geyser conncetion complete all as all as specified and directed by Engineer-in-charge.
S&F in replacement one switch and one socket semi flush type 5 PIN 15 Amp 230 volts AC complete.
S&F in replacement of PVC insulated sheathed 1.5 sqmm 3 core cable 1100 volts grade ISI marked copper conductor complete.
S&F in replacement of MCB SP 10-32 Amp 230 volt complete
M&L for sub main wiring with copper conductor two single core stranded 1100 volt grade 2.5 sqmm ISI marked drawn in PVC conduit of 20 mm dia including earth wire of green colour 2.5 sqmm conductor multi stranded FRLS including taking down the existing complete.
M&L for submain wiring with Two runs of single core 4 sqmm for main wire and one run of single core 4 sqmm as earth wire of stranded copper conductor FRLS PVC insulated unsheathed cables conforming to IS : 694 drawn through and including concealed in wall rigid medium duty unplasticised PVC conduit conforming to IS : 9537 ( Part-3) and ISI marked not less than 20 mm dia and accessorie including taking down the existing all conforming to IS specification complete.
Providing labour for servicing and maintenance of complete solar water heater plant of cap 500 LPD installed at single/double/triple story bldgs for carrying out minor leakage, cleaning of flat plate collector glass & cleaning of sintex tank and make up tank incl dismantling inlet and out let connection s and re-fixing the same after cleaning for proper functioning to maintain proper water temperature, all as specified and directed by Engr-in-Charge. (Contractor should maintain the repair system complete area qtr as and when reqd)
All as per item No 19 here in before but for cap 300/200/100 LPD
S&F in replacement of 2 KW Heat Convertor complete all as specifiend and directed
S&F in repairs bib taps cast copper alloy with crutch or butter fly handle, screwed town screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repairs Stop valve cast copper alloy scerwed down high pressure with crutch or butterfly handle screwed both end with iron pipe and for union for fixed as per sample /installed at site
M&L for replacement of make up tank made out of MS Sheet 3.15mm thick fitted with ISI mark float valve brass assy with float brass rod 15 mm dia for solar water heater capacity 12 ltr all as per existing sample, shape
M&L for replacement of toughed glass of collector of size 4mm thick and of size 6’x4’ as per existing arrangement complete all as specified.
M&L for replacement of rubber hose pipe 15mm dia between hot water tank & collector complete all as specified and directed by Engr-in-Charge
M&L in repair stainless steel storage tank suitable for Solar water heater of capacity 100 ltrs.
M&L in repair stainless steel storage tank suitable for Solar water heater of capacity 300 ltrs.
M&L for vacuum tube solar collector suitable for 100 ltrs solar water heater.
M&L for vacuum tube solar collector suitable for 200 to 300 ltrs solar water heater.
Supply and fix GI pipe medium grade 15 mm dia complete with fittings ISI marked fixed to wall/floor complete including taking down existing pipe lines complete all as specified and directed.
Supply & laying of cladding of GI pipe 15 mm bore with aluminum sheet, wire mesh, Rock wool density 4.3 Kg/CM3 for hot water pipe from hot water tank to water tape or upto the end of system complete all as specified. Note :- Cladding will be done as per standard specification by MNRE approved manufacturer's person assuring quality.
M&L for C-PVC pipe 15 mm dia fixed on wall/ceiling, including all accessories for inlet & outlet water connection of solar water heaters.
S& F mild Steel framework of steel confirming to Fe 390 Gde Ee-165 as in brackets, cooler stands etc. including cutting welding etc complete and fixing at any height in existing masonry walls including scaffolding required at as directed.
M&L for preparing new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified.
Supply and Fix in repair of water heater storage type electric capacity 3 ltr, BEE 5 Star rated
Supply and Fix in repair of water heater storage type electric capacity 25 ltr, BEE 5 Star rated
Supply and Fix in replacement of water heater storage type electric capacity 50 ltr, BEE 5 Star rated
Taking down of window/split AC upto 2.0 ton of any make opening complete (indoor and outdoor unit for split AC) and servicing of AC components carefully as cleaning with chemical solution and soft nylon brush and replace the unserviceable parts like compressor, Heating Condensor, Capacitor, Starting relay, PCB, air filter etc and tightnining of loose screw, checking wiring connection completely and re fixing in existing position and testing complete. Note:- Replacement of any unserviceable part shall be deemed to be included in the unit rate quotated. However, cost of any unserviceable items replaced shall be measured and paid as supply only under relevant item here-in-after.
Compressor of Window /Split Type AC capacity upto 2.0 TR of any make any type.
Compressor of Refrigerator/Defreezer/Water cooler of any make any type and any capacity
Capacitor of capacity 4/4.5/6 Mfd
Capacitor of capacity 45/50/60 Mfd
Overload protector relay suitable for AC 1.5/2.0 Ton
Remote control with PC board (PCB) complete suitable for window and split AC of capacity upto 2.0 TR
Testing leakage in system by injecting Nitrogen gas upto 300 PSI,rectification leaking spots/joints with gas welding work, filter anti moistoring agent, soldering, brazing, copper capillary tubing of required size and cleaning and flushing out complete system with gas making the system leak proof, vaccumising the complete system and supply and charging refrigerant gas as per existing type cooling appliances complete. Note:- No extra cost shall be paid to the contractor for gas charging (any numbers of times) in case of leakage with in six months of initial gas charging except in case where external damage to the plant is noticed.
AC Split/window 1.5/2.0 ton
Water Cooler 80/40 Capacity
Refrigerator 165/195 ltrs
Supply and fixing of voltage stabilizer 5 KVA 230v complete.
Taking down/out desert cooler of any make and capacity from various locations, transporting to MES Store Yard and dismantling all unserviceable parts for repair/overhauling/lubricating greasing/removal and replace of burn out bearing bush shaft /painting complete after scrapping old painting and re-fixing the same back to its original position and making necessary connections with and including copper flexible cable 23/0.0076 Sqmm complete all as specified and directed by Engineer-in-Charge. Note:- Replacement of any unserviceable part shall be deemed to be included in the unit rate quotated. However ,cost of any unserviceable items replaced shall be measured and paid as supply only under relevant item here-in-after
Supply only Wood wool pad
Supply only Cooler fan motor.
Supply only Fan blade
Supply only 3 pin plug top one way 5 Amp, 240V
Supply only Water lifting pump 230v single phase
Supply only Side grill cover of existing size.
S&F Single pole and neutral (SPN) MCB 40 Amps, 240v, 10KA breaking capacity.
M&L for submain wiring with two runs of single core 6 sqmm for main wire and one run of single core 6 sqmm as earth wire of stranded copper conductor FRLS PVC insulated unsheathed cables conforming to IS : 694 drawn through and including concealed in wall rigid medium duty unplasticised PVC conduit conforming to IS : 9537 ( Part-3) and ISI marked not less than 20 mm dia and accessorie all conforming to IS specification complete.
Supply and fixing double door sheet metal enclosure made out of CRCA mild steel sheet concealed surface mounting SPN, 8 way, 230 Volt, with 200 Amp rated bus bar suitable for fixing MCBs, isolators etc including taking down old complete all as specified and directed.
Supply and fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm 4 core
Excavating in trenches not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables and getting out in soft/loose soil all as specified and as directed by Engr-In-Charge.
M&L for sand cushioning to under ground cable in trenches in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge. Note:- Measurement shall be taken after gentling puning of sand.
Supplying and laying unreinforced precast concrete cable cover class LV type 1 with peak size 250mm x 150mm x 40mm (ISI Marked) Complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated hard/dense soil.
Removal of surplus soil to a distance not exceeding 50 m and depositing
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), makinging good disturbed surfaces of walls, floors, etccomplete all as specified and directed.
M&L for point wiring with 2.5 sq mm PVC insulated unsheathed single core multi-stranded copper conductor cable 1100 Volts grade, drawn through and including 20 mm dia rigid non-metallic PVC concealed conduit (medium grade) along with 2.5 sq mm continuous PVC insulated unsheathed solid/stranded copper conductor cable for earth continuity wire, connected to earth dolly and to be terminated in metal boxes readily available and suitable for 15 Amp socket concealed type including testing on completion complete all as specified and as directed by the Engineer-in-Charge for power point controlled by one 15 Amp switch.
M & L for Point wiring with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed FRLS cable, multi-stranded, copper conductor, in universal colour code with & including suitable size of rigid non-metallic PVC conduit (not less then 20mm dia med gd)and its all accessories complete concealed in wall incl cutting & chases( making good all to the disturbed surfaces as per existing) and modular flush metal boxes including cover plate with frame for mounting modular switches, sockets, regulators,socket etc including earth wire of PVC insulated FRLS copper conductor multistranded of 1.5 Sqmm size in green colour complete all as specified in current SSR Part-I & II & directed by the Engineer-in-Charge , as described below:-
One light point controlled by one way Modular switch 5 amp complete.
One 3 pin 5 Amps socket point controlled by one Modular switch on same board.
One 3 pin 5 Amps socket point controlled by one Modular switch on independent board.
One bell point controlled by one Modular push button on independent board
One light point controlled by two switches two way.
All as per item No. 55.00 (here-in-before) but for 15 Amp socket out let by using 2.5 Sqmm PVC insulated unsheathed copper conductor cable FRLS multi strand on independent board including provn of 2.5 Sqmm unsheathed, multi stranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed by Engineer-in-Charge.
S&F modular type switch piano type, 6 Amp 240 Volt, AC (ISI Marked) one way etc complete all as specified and directed by Engineer-in-Charge.
S&F modular type switch piano type, 6 Amp 240 Volt, AC (ISI Marked) two way etc complete all as specified and directed by Engineer-in-Charge.
S&F modular type switch piano type, 16 Amp 240 Volt, AC (ISI Marked) one way etc complete all as specified and directed by Engineer-in-Charge.
S&F modular one socket outlet 5 Pin 5 Amp 230 volts AC omplete all as specified.
S&F modular one socket outlet multipurpose 3 Pin 5 Amp and 6 Pin 15 Amp 230 volts AC complete all as specified.
S&F modular Ceiling fan regulator electronic step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan etc complete all as specified and directed by Engineer-in-Charge.
S&F bell push, 5 Amp, 230 V, AC complete all as specified and directed by Engineer-in-Charge.
S&F in repair of modular white cover plate of size 1 module with frame complete all as specified and directed by Engineer-in-charge.
S&F in repair in replacement of unserviceable modular white cover plate of size 2 module with frame complete all as specified and directed by Engineer-in-charge.
S&F in repair of modular white cover plate of size 3 module with frame complete all as specified and directed by Engineer-in-charge.
S&F in repair of modular white cover plate of size 4 module with frame complete all as specified and directed by Engineer-in-charge.
S&F in repair of modular white cover plate of size 6 module with frame complete all as specified and directed by Engineer-in-charge.
S&F in repair of modular white cover plate of size 8 module with frame complete all as specified and directed by Engineer-in-charge.
S&F in repair of modular metal flush box of size 1/2 module with nut bolt etc in wall complete all as specified and directed by Engineer-in-charge.
S&F in repair of modular metal flush box of size 3 module with nut bolt etc in wall complete all as specified and directed by Engineer-in-charge.
S&F in repair of modular metal flush box of size 4 module with nut bolt etc in wall complete all as specified and directed by Engineer-in-charge.
S&F in repair of modular metal flush box of size 6/8 module with nut bolt etc in wall complete all as specified and directed by Engineer-in-charge.
S&F one socket flush type outlet 5 Pin 16 Amp, 230 volts AC complete all as specified.
S&F one switch flush type,16 Amp, 230 volts AC complete all as specified.
S&F ceiling rose surface bakelite 65mm x 50mm, 2 to 3 terminals with back plate etc complete all as specified and directed by Engineer-in-Charge.
S&F Lamp holder of PVC / Polycarbonate type surface for CFL / bulb etc complete all as specified and directed by Engineer-in-Charge.
S&F call bell ding dong type, AC, 230 V etc complete all as specicied and directed by Engineer-in-Charge.
S&F in repair of Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket, one single pole 20 Amps, 240V MCB complaints complete all as specified and directed
Supply and fixing double door sheet metal enclosure made out of CRCA mild steel sheet concealed surface mounting SPN, 8 way, 230 Volt, with 200 Amp rated bus bar suitable for fixing MCBs, isolators etc including taking down old complete all as specified and directed.
Supply and fixing double door sheet metal enclosure made out of CRCA mild steel sheet concealed surface mounting TPN, 4 way, 230 Volt, with 200 Amp rated bus bar suitable for fixing MCBs, isolators etc including taking down old complete all as specified and directed.
S&F MCB TPN 100 Amps C curves MCB repturing capacity 10 KA etc complete all as specified and directed by Engineer-in-Charge.
S&F MCB TPN 63 Amps C curves MCB repturing capacity 10 KA etc complete all as specified and directed by Engineer-in-Charge.
S&F MCB TPN 40 Amps C curves MCB repturing capacity 10 KA etc complete all as specified and directed by Engineer-in-Charge.
S&F MCB SPN 63 amp c curves MCB repturing capacity 10 KA etc complete all as specified and directed by Engineer-in-Charge.
S&F MCB SPN 40 amp c curves MCB repturing capacity 10 KA etc complete all as specified and directed by Engineer-in-Charge.
S&F MCB 6 Amp to 32 Amp SP capacities 'C' series 10KA rupturing capacaity complete all as specified and directed.
Supply only 3 pin 15 Amps Plug Top 250 Volts heavy duty complete all as specified and as directed.
S&F including taking down of Sub main two single core PVC copper conductor unsheathed wire multi stranded 6 sqmm in existing PVC conduit pipe and including 6.0 sqmm copper conductor single core wire connected by common earth all as specified. Note :- Three runs of 6 sqmm cable & 20mm PVC Conduit will be measured as one unit length.
S&F including taking down of Sub main two single core PVC copper conductor unsheathed wire multi stranded 4 sqmm in existing PVC conduit pipe and including 4.0sqmm copper conductor single core wire connected by common earth all as specified. Note :- Three runs of 4.0 sqmm cable & 20 mm PVC Conduit will be measured as one unit length.
S&F including taking down of Sub main two single core PVC copper conductor unsheathed wire multi stranded 2.5 sqmm in concealed PVC conduit pipe 20 mm dia, medium grade and including 2.5 sqmm copper conductor single core wire connected by common earth all as specified. Note :- Three runs of 2.5 sqmm cable & 20mm PVC Conduit will be measured as one unit length.
Material and labour for Earthing complete with GI earth plate 600mm x 600mm x 6 mm thick electrode buried directly in ground (earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level connected to GI wire 4.0 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES schedule Part-I and incl 15 mm bore light grade GI protection pipe (upto 7.5 metres beyond outer edge of earth pit) PCC M-10 grade (Nominal Mix) using 40mm graded stone aggregate in pit with 40mm thick RCC cover in reinforced cement concrete M-15 grade (Nominal Mix) using 20mm graded stone aggregate, reinforced with 8mm dia bar both way @ 150mm c/c, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and chaarcoal filling, necessary excavation and earth work complete.
Supply and Fixing LED batton fitting 1 x20 Watt, 6000K, 4" complete fitting connection with 2 core flexible cable 23/0.00076 from ceiling rose to tube fitting connection etc complete all as specified and directed by Engineer-in-charge. Make:- Cat part No LHEXBLP7PN1W020 of Havells or equivalent in Phillips/Bajaj/Crompton/C&S
S&F mini LED light fitting 9 W ,6000K indoor domestic mirror light luminarire with poly carbonate cover complete with all acessories and driver including connections with with twin core wire of suitable size all as specified. Make:- Cat part No LHEXBLP7IN1W009 of Havells or equivalent in Phillips/Bajaj/Crompton/C&S
S&F LED light fitting, 1X30 watt,5700 K complete with tuff net glass protection IP:66, fixed to walls with GI bracket made out of suitable size of light grade pipe 32 mm dia tubing upto 1.2 mtr length bent to shape with 02 sets of MS clamps made out of 25x3 mm MS flat iron with suitable bolt and nuts and testing etc complete all as specified and directed by Engineer-in-charge. Make:- Cat Part No PUBO506026 of Polycab or equivalent in Bajaj/Crompton/Phillips/Havells/C&S
Supply and fixing LED decorative, wall mounting, champagne gold finish fixture with plastic body suitable for 9 W LED lamp B22 base complete all as specified and directed by Engineer-in-charge. Make:- Cat Part No LHFOECE1TZ1O014 of Havells or equivalent in Crompton/Bajaj/Phillips/C&S
Taking down the ceiling fan of any sweep carefully from its installed position, dismantling complete with down rod , replacement of capacitor, Rubber wheel bush and cleaning of all dust, applying grease for bearings, reassembling the fan and blades, painting of fans and down rod with synthetic enamel white paint by spraying including filling cavities with filler, writing MES No. with black paint, and keeping a side safely and hanging / refixing in position and connecting up including provision of 3 core twisted flexible copper conductor cable of 0.75 Sqmm from ceiling rose to connector of fan and testing on completion complete all as directed. NOTE:- (i). The unit rate is deemed to include the cost of taking down carefully fans from existing position after disconnecting electric connections, sealing cable ends,replacement old coper wire of 1.5sqmm size upto 1mtr bringing to MES store yard. (ii) Cost of major items such as ball bearing, gun metal bush, capacitors, blades, canopy and repair/ rewinding /painting etc shall be measured and paid separately under relevant item of this schedule as supply only. (iii) Minor items or works like tightening loose connections in switch, binding insulation tape to the naked wires, replacement of unserviceable clamps, nuts and bolts, split pins, rubber reel, washers etc will be provided without any extra cost and cost of these minor items or works will be deemed to be included in the quoted rates against this item.
M&L for Rewinding of ceiling fan motor of any type, any size,and make with approved quality of super enamelled copper wire as per original gauge and size including varnishing heating etc complee all as directed.
Supply only capacitor 2.15/ 2.5 micro Farad, 240 Volt, two wired and ISI marked complete all as directed
Supply only ball bearing of No 6201 complete all as directed.
Supply and fix in repair of iron down rod/connecting rod of ceiling fan of size upto 600 mm with new nuts, bolts and safety pins complete all as directed.
Supply and Fixing in repair of ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor, white colour complete all as specified and directed by Engineer-in-charge.
Taking down carefully old unserviceable plastic / metalic exhaust fan of any type by disconnecting all electrical connections and deposit to MES store yard complete all as directed by Engr-in-charge. (Note : (a) All old unserviceable exhaust fan are property of MES Department and Contractor shall be deposited to MES Store Yard .
M&L for Rewinding of Exhaust fan of size upto 350 mm motor of any type, any size,and make with approved quality of super enamelled copper wire as per original gauge and size including varnishing heating etc complee all as directed.
Supply only capacitor 3.15/4 micro Farad ,240 volts, two wired and ISI marked complete all as directed
Supply only ball bearing of No 6202, complete all as directed.
Supply only ball bearing of No 6203 complete all as directed.
Supply and fix in repair of iron down rod/connecting rod of ceiling fan of size upto 600 mm with new nuts, bolts and safety pins complete all as directed.
Supply and Fixing in repair of ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor, white colour complete all as specified and directed by Engineer-in-charge.
S&F in repair of new Exhaust fan 450 mm of sweep, metal body, gery colour complete with louvers complete all as specified and directed.
S&F in repair of new Exhaust fan 250 mm of sweep, made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding,gery colour complete all as specified and directed.
Supply and Fixing in replacement of unserviceable/broken Bakelite hylum sheet of size (8"X10") with suitable screw etc complete.
Supply and Fixing in replacement of unserviceable/broken Bakelite hylum sheet of size (7"X4"). with suitable screw etc complete.
Supply and Fixing in replacement of unserviceable/broken Bakelite hylum sheet of size (10"X12") with suitable screw etc complete.
Supply and Fixing in replacement of unserviceable/broken Bakelite hylum sheet of size (5"X5") with suitable screw etc complete.
Supply and fix XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 4 core
Ms Kamal Kant Agarwal
ISHWAR ENTERPRISES
S M TRADERS
ASHOK INFRATECH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .