Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC | ₹10.3 L | L1 | Accepted-AOC ok |
| 2 | L2₹10.3 L+₹8,622.04 (0.84%)Rejected-Finance | ₹10.3 L+₹8,622.04 (0.84%) | L2 | Rejected-Finance EMD TO BE REFUND |
| 3 | L3₹10.4 L+₹11,219.04 (1.09%)Rejected-Finance 123 2 9 BECHARAM CHATTERJEE ROAD BEHALA KOLKATA 700034 | KOLKATA | SOUTH 24 PARGANAS | WEST BENGAL | 700034 | ₹10.4 L+₹11,219.04 (1.09%) | L3 | Rejected-Finance EMD TO BE REFUND |
Tender Value
₹10.4 L
EMD Value
₹20,776
Closing Date
30 Jan 2026, 5:00 pmClosed
EXECUTIVE ENGINEER ADDA ASANSOL
Vivekananda Sarani, Senraleigh Road Near Kalyanpur Housing More,Asansol -713305
Balance work for Building of Amra Kajan Club at A Block, Ward No 20 , A.M.C. Asansol in the District of Paschim Bardhaman
2026_ADDA_987665_2
ADDA/ASN/ED/N-66(2025-2026)
Open Tender
CIVIL WORKS
Percentage
90 days
ADDA ASANSOL
As per tender documents
3 documents required · 3 mandatory
₹0
₹20,776
27 Mar 2026
15 Jan 2026
2 Feb 2026
15 Jan 2026
30 Jan 2026
15 Jan 2026
Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite or sand stone ) including removing spreading or stacking the spoils within a lead of 75 metre as per direction.The items includes necessary trimming the sides of trenches, levelling , dressing & ramming the bottom , bailing out water as required complete.
Depth of excavation not exceeding 1500 mm
Earth work in filling in foundation trenches or plinth with goode earth , in layers not exceeding 150 mm. Including watering and ramming etc. layer by layer, complete.
With earth obtained from excavation of foundation.
Flling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidating same by through saturation with water and ramming complete including cost of sand.
By Fine sand .
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand .
Supplying and laying Polythene sheet (150 gm / sqm ) over damp proof course or below flooring or in foundation trenches .
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground flooras per relevant IS codes.
Brick work with 1st class bricks in cement mortar (1:6)
In foundation and plinth
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor .
Ground floor
Controlled Cement concrete with well graded stone chips (20 mm graded nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation. . M 20 Grade [ Using concrete mixture]
Ground floor
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with rewuired bracing for concrete slabs, beams, columns, lintels, curved or straight including fitting , fixing and stricking out after completion of works.
25 mm to 30 mm wooden shuttering
Upto Ground floor roof level
25 mm to 30 mm wooden shuttering
Shuttering without staging in foundation etc.
Supplying steel reinforcement for R.C.C. work ready to use (cut & Bend ) rebars (i,e, stirrups for all types and all shape , tie bars , stairs etc. for slab beams and cloumn , piles, raft etc.) of approved make from factory workshop to construction site including placing in position and bindings all complete as per per drawing and direction of EIC. Thermo Mechanicaly treated bars of Grade Fe 500 garde or more.
Other than SAIL/TATA/RINL
Upto Ground floor roof level.
Plaster (to wall, floor, etc.) with sand and cement mortar including rounding off or chamfering corners, as directed and racking out joints roughening of concrete surface including chipping and application of cement slurry where necessary etc. complete.
With 6:1 cement mortar.
15 mm thick plaster (Out side) height upto 5.0 m
In ground floor.
With 6:1 cement mortar.
20 mm thick plaster (Inside) height upto 5.0 m
In ground floor.
10 mm thick plaster (Celing) height upto 5.0 m
With 4:1 cement mortar.
In ground floor.
Neat cement punning about 1.5 mm thick in wall , dado, window sills, floor, drain etc.
Artificial stone in floor , dado, staircase etc.with cement concrete (4:2:1) laid in panels as directed, with topping made with ordinary or white cement (as necessary) and marble dust in proportion (2:1) including smooth finishing and rounding off corners including application of cement sullry before flooring works, using cement @ 1.75 kg/sqm all complete including all materials and labour.(In G Floor/ With graded stone chips :3 mm thick topping (High polishing grinding on this item is not permitted) with ordinary cement.
35 mm thick artificial stone./ In First floor roof
Supplying fitting and fixing windows and ventilators with or without integrated grills conforming to I.S. 1038 -1975 and manufactured from rolled steel sections conforming to I.S. to 7452 - 1974 with non friction projection, straightnening if required, fixing lugs in cement concrete (4:2:1) with stone chips 19 mm down , cutting holes and mending good damages to match wuth existing surface complete in all respect excluding glazing.
Opeanable steel windows as per I.S. sizes with side hung shutters and horizontal glazing bars , with or without fixed type ventilators in Ground floor
In Ground floor.
Two point nose steel hande including fitting and fixing.
Steel peg stay 300 mm long including fitting and fixing.
M.S inegrated griil as per approved design integrated with steel window or ventilator, joints continuosly welded with M.S. flats and bars.
M.S. Gate of jail type as per approved design made of strong M.S. framework and intermidiate sitiffiners/ round / squire bars or angles and with lining of 14 gauge thick M.S. sheets including necessary locking & hanging arrangement fitted and fixed complete as per direction of EIC.
In Ground floor.
Supplying 1.5 mm thick M.S. Sheet fitted and fix at one or Both faces of M.S. / W.I Gate etc. with point weldeing not more than 150 mm apart complete inall respect as per design including cost of all labour & materials.
In Ground floor.
Supplying fitting and fixing door frame with M.S. angle as per drawing and direction of required section. The holes for counter sunk machine screw and nut will be such as to fit 8 to 10 mm iron screw. The counter sunk nut to be welded . The nuts are to be welded after carefull checking with screw. All welding spot should be properly filled or rounded smoot including cost of welding hinges for hinge cleates , lugs for hasp bolt , socket bolt etc. and necessary M.S. clampof 25 mm x 6 mm flat 225 mm long as per direction welded to the frame fitted and fixed in position excluding cost of concrete.
M .S. angle frame: 65 x 65 x 8 mm @ 7.7 Kg / m
Priming one coat on steel or other metal surface with synthetic enamel/ oil bound primer of approved quality including smoothening surfaces by sand papering etc
On steel surface
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary
On Steel surface / hi- gloss
Two coats (with any shade except white).
Rendering the surface of walls and ceiling with white cement based water proof wall putty of approved make and brand(1.5mm thick)
Acrylic distemper to interior wall , celling with a coat of solvent based interior grade acrylic primer as per manufactures specification including cleaning and smoothing of surface.
Two coats
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface thoroughly, complete as per manufacturer's specification and as per direction of the EIC.
One Coat in Ground floor
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. [Normal Acrylic emulsion]
Two Coat in Ground floor
Supplying fitting and fixing UPVC pipes A type and fitting conforming to Is: 13592-1992 with all necessary clamps nails, including making holes in walls, floors etc. cutting trenches in any soil thorugh masonry concrete structure etc. .f necessary and mending good damages including jointing with jointing materials(Spun yarn,valamoid / bitumen / M.seal etc.) complete.
110 mm diameter.
Supplying ,fitting and fixing UPVC fittings conforming to IS 13592-1992.
Plain tee / 110 mm dia
shoe/ 110 mm dia
Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as per direction of Engineering -in -Charge in Ground Floor. {White cement and Pigment to be supplied by the Agency]
With Chawk Dungri Area of each tile exceeding 0.3 sq.m but not excedding 0.6 sq.m.
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors and 4 nos. key stone (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.
Wall - with sand cement mortar (1:3) 15mm thick & 2mm thick cement slurry at back side of tiles using cement @2.91 kg/sq.m. and joint filling using white cement slurry @ 0.2 kg/Sq.m.[Area of each tile upto 0.09 Sq.m.]
Other than Coloured Decorative./ White in Ground Floor
Supplying fitting and fixing plaque made of Granite slabs ( single piece) of 15 mm to 18 mm thick with uniform texture and without decorative veins in facia etc fixing with using Cement slurry at back side of granite @4.4 kg/sq.m and white cement slurry for joint filling @1.8 kg/sq.m.including making lettering , sign marks etc as per direction in the granite slabs with fixed at brick wall (in 1:6) as directed including earth cutting , 75 mm thick sand filling , 75 mm thick Cement concrete (1:2:4) and plastering with 20 mm thick sand cement mortar (6:1) as specifed by the Department including wall putty , Acrylic primer & Super Protective 100% Acrylic Emulsion two coats including all incedential charges for labours , materials , machinaries & transportig charges complete in all respect as per direction of EIC.
Sub Total
Add GST @ 18% on Sub-Total Cost, i.e.
Add Labour Welfare Cess @ 1% on Total cost after GST, i.e.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.15 MB
Tendernotice_2.pdf
PDF • 2.00 MB
BOQ_2412625.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .