Loading…
Loading…
Tender Value
₹6.8 Cr
EMD Value
₹13.5 L
Closing Date
30 Apr 2026, 5:30 amClosed
Facilities Management Division, Bangalore
HINDUSTAN AERONAUTICS LIMITED Facilities Management Division, Bangalore
Proposed Construction of New Stores Hangar Building including Civil Electrical and Mechanical Works at Overhaul Division HAL BC
25362
TENDER NOTICE/NCP/125/25-26
Limited
Works
Contract Section Civil-FMD-Bangalore
| # | Company Name | Location | Address |
|---|---|---|---|
| 1 | BUILTECH ENGINEERING SOLUTIONS | BANGALORE,India | NO 1467, 2ND FLOOR, B-BLOCK,SAHAKARNAGARA,BANGALORE,Karnataka,India,Pin-560092 |
| 2 | MANSUN INTERIORS | BANGALORE,India | 645 5TH C MAIN MUNESHWARA LAYOUT LAGGERE,617 2ND MAIN 7TH CROSS MUNESHWARA LAYOUT LAGGERE,BANGALORE,Karnataka,India,Pin-560058 |
| 3 | SRICO PROJECTS PVT LTD | HYDERABAD,India | PLOT NO 178 A MLA COLONY,ROAD NO12 BANJARAHILLS,HYDERABAD,Andhra Pradesh,India,Pin-500034 |
| 4 | SAANVIPRIYA BUILDTECH PVT LTD | Bangalore,India | 18 4th floor 17th F cross indiranagar bangalore 38,,Bangalore,Karnataka,India,Pin-560038 |
| 5 | V S SHIVARAM CIVIL WORK CONTRACTOR | Bengaluru,India | F 3, A block, Gurupriya Akashaganga Apartment 6th cross,1st A main, ISRO layout, Bengaluru-560078,Bengaluru,Karnataka,India,Pin-560078 |
BUILTECH ENGINEERING SOLUTIONS
BANGALORE,India
NO 1467, 2ND FLOOR, B-BLOCK,SAHAKARNAGARA,BANGALORE,Karnataka,India,Pin-560092
MANSUN INTERIORS
BANGALORE,India
645 5TH C MAIN MUNESHWARA LAYOUT LAGGERE,617 2ND MAIN 7TH CROSS MUNESHWARA LAYOUT LAGGERE,BANGALORE,Karnataka,India,Pin-560058
SRICO PROJECTS PVT LTD
HYDERABAD,India
PLOT NO 178 A MLA COLONY,ROAD NO12 BANJARAHILLS,HYDERABAD,Andhra Pradesh,India,Pin-500034
SAANVIPRIYA BUILDTECH PVT LTD
Bangalore,India
18 4th floor 17th F cross indiranagar bangalore 38,,Bangalore,Karnataka,India,Pin-560038
V S SHIVARAM CIVIL WORK CONTRACTOR
Bengaluru,India
F 3, A block, Gurupriya Akashaganga Apartment 6th cross,1st A main, ISRO layout, Bengaluru-560078,Bengaluru,Karnataka,India,Pin-560078
₹0
₹13.5 L
30 Apr 2026
2 Apr 2026
2 Apr 2026
30 Apr 2026
Name of the Individual / Firm / Company: * Mandatory
Type of ownership
Year of Estblishment of Company/Business
If Other, please specify
Details of Constitution or Legal Status such as certificate of incorporation, shops and establishments, etc.,
Address for correspondence:
TIN number
PAN no and Name of Holder
PF number (If any)
ESI number
Service Tax Registration No
Goods and Service Tax ID No.
SAC Code
Contact details
Registered Contractor
Pls Enter
Need to Fill Column 19
Maximum value of works excuted during the followinf 5 years. . (In Lakhs)
Pls enter Finiancial Turnover in Rupees for all the years
DETAIL OF WORK ON HAND UPTO N-Months (N-contract period) [For Bid capacity calculation] NOTE : PROVISION for 10 works are given. If more, a separate similar sheet to be made showing all the works with all details as per this FORMAT and same to Uploaded. However, 9 works details to be provided and balance work value of other works to be added and to be provided in 10th row as OTHER works.
Name of Organization with address
Balance Work On Hand
Work Schedule for completion of works with in stipulated time [Please enclose action plan / bar chart as to indicate the completion of work, within the scheduled time (contract period)]
Quantity of work Excuted during the last three years
Bank(s) details: [Copy of the cheque leaf to be uploaded]
Bank Account No.
Bank Statement for past three month
Latest Over draft Facilties with Bank enter Name of Bank, Date of Issue and Value of Over Draft
Latest Bankers Solvency Certificate from Nationalized/ scheduled Bank issued NOT before 12 months from the date of Tender Notice.
#VALUE!
Experience of having successfully completed similar works during last 7 years ending on the previous day of submission of tender. [Work experience certificates / Completion certificates should be uploaded for verification]. [Latest work experience certificate may be uploaded] (i) THREE similar completed works each costing not less than the amount equal to 40% of the estimated cost. (ii) TWO similar completed works each costing not less than the amount equal to 50% of the estimated cost. (iii) ONE similar completed work each costing not less than the amount equal to 80% of the estimated cost. [Amount put to the Tender]
You are Not Eligible
Type of Work [ Incase of private works the same shall be supported with TDS certificate]
Type of Work [ Incase of private works the same shall be supported with TDS certificate]
work done
Type of Work and Organisation name [ Incase of private works the same shall be supported with TDS certificate]
#VALUE!
Related Document to be Uploaded to eProcurement Portal
DEAILS OF TECHNICAL PERSONNEL AVAILABLE( if space provided is insufficant separate sheet to be uploaded with the same format as below)
Name of members or technical personllel avalable in the organization
DETAILS OF MACHINERY AVAILABLE
Name of Mechinery
Concrete Mixers - Type etc
Vibrators - Diesel - Electrical
Weiding equipment's
a) Rectifiers
b) Welding Generators
Erection equipment's
Cranes-
Hoists-
Lifts-
Water Lifting motor pumps
a) Diesel
b) electric
Drilling Equipment's
Compressors
Trucks
Stone crushers
Bitumen hot mixture plant
Bitume boiler
Rollers
Batching plants
Vibratory rollers
Generators
Cranes-Details
Concrete pumps
Road Pavers
Rock breakers
Transit mixers
Excavators
Weight batches
Others
Details of person holding the power of Attorney (If different from contact person)
Related Document to be Uploaded to eProcurement Portal
DECLARATION
Pls enter
Tender Document Cost and EMD details
Enclosed / Not enclosed
Enclosed
Enclosed
Average annual financial turn over during the last 3 years, ending 31st March 2025 [ should not be less than 30% of amount put to tender] and details for last 5 years to be provided to assess the bid capacity. The values provided to be supported by uploading Balance Sheet along with Profit & loss account statement. . (In Lakhs)
Specification
Disposal of surplus earth / moorum / building rubbish / malba / similar unserviceable, dismantled or waste material of partitions, ceiling boards, tiles, frames, etc., by mechanical transport including loading, transporting, unloading in all lifts / loads upt 10 km distance from HAL, etc., all complete as directed by Engineer-in-Charge.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas in all kinds of soft / hard soil for foundations, footings, columns, pedestals, Plinths or members as per the drawing, etc., (exceeding 30cm in depth, 1.50m in width as well as 10Sq m on plan) including removal of vegetation and in-equalities, shoring, strutting for protecting the sides of foundation if required, removing slips or falls in excavation, forming steps in sides of deep excavations and their removal or covering up, levelling, ramming the bottom of excavation, getting out and disposal of excavated earth lead upto 50m and in all lifts with all labour, tools & tackles, plant & machinery, hire & fuel charges, etc., all complete as directed by Engineer-in-Charge.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains, pipes, cables, etc., in all kinds of soils (not exceeding 1.50m in width or 10Sq m on plan), including dressing of sides and ramming of bottoms, for all lifts, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m with all labour, tools & tackles, plant & machinery, hire & fuel charges, etc., all complete as directed by Engineer-in-Charge.
Returning / filling in with useful excavated soil (excluding rock), free from salts, organic or other deleterious matter (Other than black cotton soil & rock, etc., in trenches, plinth, sides of foundations, etc., spreading in layers not exceeding 20cm thick, watering, breaking / removing clods exceeding 50mm, ramming and consolidation of each deposited layer, etc., with all labour, tools & tackles, plant & machinery, etc., lead upto 50m and for all lifts, etc., all complete as directed by Engineer-in-Charge.
Supply, stacking, Laying, spreading and compacting Moorum as per specification in uniform thickness upto 200mm thick in each layers, rolling, compacting in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density, etc., all complete as directed by Engineer-in-Charge.
Supplying, mixing and placing plain cement concrete (1:3:6) of required thickness using 20mm down graded hard stone / granite aggregate in accordance with IS 456 in foundations, mass concrete, sub bases, flagging / plinth course and leveling courses and other similar works including formwork, mechanical mixing, transporting, vibrating, consolidation, levelling, curing, dewatering if any, all materials, labour, lead & lift, tools, plant & machinery, keeping concrete well wetted during the curing period and protecting it in extreme weather conditions, etc., but excluding the cost of centering, shuttering, etc., all complete as directed by Engineer-in-Charge.
Supplying, mixing and placing plain cement concrete (1:2:4) (1 Cement : 2 coarse sand derived from natural sources : 4 graded stone aggregate) of required thickness using 20mm nominal size down graded hard stone/granite aggregate in accordance with IS 456 in posts, struts, buttresses, string or lacing courses,parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, plinth area, etc., including formwork, mechanical mixing, transporting, vibrating, consolidation, levelling, curing, dewatering if any, all materials, labour, lead & lift, tools, plant & machinery, keeping concrete well wetted during the curing period and protecting it in extreme weather conditions etc., but excluding the cost of centering, shuttering and finishing, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing at or near ground level precast cement concrete of ratio (1:1½:3 ) in kerbs, edgings, etc., as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering,curing, etc., all complete as directed by Engineer-in-Charge.
Supplying, straightening, fabricating (cutting & bending), placing in position and binding steel reinforcement of TMT bars of not less than Fe 500 D conforming to IS 1786 for all concrete reinforcment members / works above / below plinth level, including cutting to length, bending to shape required, including cranking, bending spirally for hooping for column, hooking ends and binding with mild steel wire (Annealed) not less than 0.90mm dia or securing with clips, including fixing and bracing, wastage, welding, supporting or otherwise holding firmly in position so that the placing and ramming of concrete will not displace it, etc., complete all as per specifications, drawings and as directed by the Engineer-in-Charge. Note: a) Only authorized laps, chairs etc. shall be considered for measurement. b) The exposed Reinforcement bars shall be coated with cement slurry.
Providing and laying in position ready mixed or site batched M25 Grade with minimum cement content of 330 kg/m3 design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength including pumping of concrete to site of laying, consolidation, levelling, curing, scaffolding, all materials, labour, carriage for all leads & lifts but excluding the cost of centering, shuttering, finishing and reinforcement, etc., all complete as directed by Engineer-in-Charge. Note: (i) Mix design to be obtained from Govt. / NABL laboratory for site batching concrete.
All works upto plinth level like footing, pedetsal, trenches, plinths, mass concrete including necessary openings and packing if any for laying pipes, cables, etc.,
All works above plinth level like Column, beams, slabs, Brakets, canopy, chajja, sunshades, stairscases, floors, etc., including necessary openings and packing if any for laying pipes, cables, etc.,
Formwork by providing timber, wooden planks, runners / M.S. sheets with all supports, struts, braces, wedges, scaffolds, bracings, ladders, gangways, dressing with oil including M.S. bolts nuts and washers, temporary openings, filleting for a stop, chamfered edges, internal / external splayed, rounded angles or grooves for forming throating including making temporary openings in the forms for pouring concrete etc as per drawing, etc., all complete as directed by the Engineer-in-Charge Note :Formwork material is contractor's own property and shall be removed after completion of work.
Foundations, pile caps, footings, bases of columns / pedestal, Lift walls / trenches, drainage walls, for mass concrete, etc.,
For Columns, Pillars, Piers, Abutments, Posts and Struts
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Suspended floors, roofs slab, landings, balconies and access platform catwalk, brackets, etc.,
Shuttrering for Gutter slab (Only Plan area to be measured for payment)
Shuttering for Cold storage Slab (Only Plan area to be measured for payment)
Shuttering for AHU Room Slab (Only Plan area to be measured for payment)
Shuttering for LCA-Cleaning area Slab (Only Plan area to be measured for payment)
Shuttering for Staircase excluding Landing
For Retaining Walls, U.G.sump, lift pit, Trenches, drains, Gutter wall
Supply and Construction of Sized stone masonary works with CM(1:6) in foundation and plinth by placing the stones in layers, packing, leveling, curing and finishing the joint, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing Granite stone slab of with (18mm to 25mm thick), area of slab not less than 0.50Sq m, like Ruby Red / Black / Cherry with gang saw cut, mirror polished, premoulded and prepolished, machine cut for platforms, vanity counters, and similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish at all levels, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing in Wall lining flat pressed three layer (medium density) particle board of 12mm thickor graded wood Pre-laminated one side decorative lamination and other side balancing lamination Grade I, Type II, IS : 12823 marked, including priming coat on unexposed arrangement and screws, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing Second Class Teak wood for frames of doors, windows, hand rails, frame work for partitions, etc., cut to shape and required curvature and preparing the surfaces to receive the polishing fixed in position with hold fast lugs / with dash fasteners of required dia & length / SS Screws at all heights, with necessary moisture content test, etc., all complete as directed by Engineer-in-Charge. (Fastners / hold fasts / SS Screws to be paid separately)
Providing and fixing 35mm thick flush door shutters conforming to IS :2202 (Part I) non-decorative type of approved brand/make, core of block board construction with frame of 1st class hard wood & lipping with 2nd class teak wood battens 25mm minimum depth on all edges and well matched commercial 3ply veneering with vertical grains or cross bands including ISI marked Stainless Steel butt hinges with necessary screws and face veneers on both faces of shutters and making rectangular vision panel of 0.10Sq m with 6mm thick clear heat strengthened glass, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing panelling minimum 5mm thick glass panes for glazing in panelled or glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), etc., all complete as directed by Engineer-in-Charge.
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section [90 x 45]mm having single rebate of [32 x 15]mm to receive shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish including accessories made with fire retardant grade unsaturated polyester resin, moulded to 3mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856 of approved brand / type, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing bright finished brass handles of 125mm size with screws, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing bright finished brass tower bolts of 250x10mm (barrel type) with necessary screws, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing bright finished brass 100mm mortice latch and lock with min. 4levers and a pair of lever handles of approved quality with necessary screws, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700mm), with necessary accessories and screws, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing aluminium sliding door bolts (aldrop) of [250 x 16]mm , ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc.
Providing and fixing 20mm dia chromium plated brass curtain rod / Towel rail of 1800mm long having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves, etc., wherever necessary.
Providing and fixing M.S. grills for windows and openings / ventilators / with made of M.S. flats, square or round bars to openings of required pattern/ frames of windows with rawl plugs screws, etc., including priming coat with approved steel primer, etc., all complete as directed by Engineer-in-Charge.
Steel work welded in built up sections / framed work, In stringers, treads, landings, etc., of stair cases, use of chequered plate wherever required, edge frames / angles for false ceiling, foundation edges, pedestal, frames, base plates, guard bar, ladder, M.S.railings, brackets, gates and similar works including cutting, hoisting, fixing in positionwith required foundation an danchor bolts and applying two caots of enamel paint over a priming coat of approved steel primer, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates, etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts, etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement, etc., all complete as directed by Engineer-in-Charge. (for payment purpose only weight of stainless steel members shall be considered.
Providing and laying Glazed Vitrified floor tiles / Matt / Antiskid finish of Size [600 X 600]mm or standard availabe size with Joint in different sizes (Thickness to be sepcified by the manufacturer) with water absorption less than 0.08% and confirming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement: 4 course sand), including grouting the joints with grey cement slurry @ 3.30 Kg/Sq m including grouting the joints with white cement and matching pigments, etc., all complete as directed by Engineer-in-Charge.
Providing and laying Vitrified tiles using various sized tiles Matt / Antiskid finish (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in cladding, skirting, riser of steps, over 12mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.30 kg/Sq m including grouting the joint with white cement & matching pigments, etc., all complete as directed by Engineer-in-Charge.
Providing and laying Polished Granite stone flooring and stair case raiser / partitions / divider and steps in colour Black, Cherry / Ruby Red or Equivalent in required design and patterns, in linear as well as curvilinier portions of building as complete as per the architectural drawings / Site condition with 18mm thick stone slab on 20mm (average) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand) laid and jointed with cement slurry and pointed with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing, nosing, chamfering and making grooves, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing Single socketed pipes of minimum 110mm diameter SWR pipes of Type B confirming to IS 13592 of approved brand for Rain water pipes, Toilet, Kitchen, Pantry outlets including necessary with suitable brackets on walls, beams, walls with bends, collars, elbows, shoe, etc., jointing with / without seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing Single socketed pipes of upto 75mm diameter SWR pipes of Type B confirming to IS 13592 of approved brand for Rain water pipes, Toilet, Kitchen, Pantry outlets including necessary with suitable brackets on walls, beams, walls with bends, collars, elbows, shoe, etc., jointing with / without seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, etc., all complete as directed by Engineer-in-Charge.
Designing, fabricating, testing, installing and fixing in position Curtain Wall system comprising of ACP of approved colour and design with open grooves for linear as well as curvilinear portions of the building for all heights and all levels, etc., and with structural sealant, including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.50mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods, etc., and also with 6mm thick high performance glass. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts, SS bolts with washer of different sizes for structural glazing / ACP Cladding, etc., all complete required to perform as per specification and drawing. The item includes cost of all stagging, material & labour component, the cost of all
Plastering to internal brick / block wall with 15mm thick on the rough side of single or half brick wall of cemnet mortor (1:6) including leveling,curing and making the level smooth and at all heights, plaster drip course / groove in plastered surface or moulding to R.C.C. projections and execute the work, etc., all complete as directed by Engineer-in-Charge.
Plastering to ceiling with 12mm thick on the rough side with cemnet mortor (1:4) including leveling,curing and making the level smooth and at all heights and execute the work, etc., all complete as directed by Engineer-in-Charge.
Plastering to external brick / block wall with 18mm cement plaster in two coats under layer 12mm thick cement plaster on the rough side with cement mortor 1:5 (1 cement : 5 coarse sand) finished with a top layer 6mm thick cement plaster 1:6 (1 cement : 6 fine sand) including leveling, curing and making the level smooth and at all heights, plaster drip course / groove in plastered surface or moulding to R.C.C. projections, etc., all complete as directed by Engineer-in-Charge.
Plastering from FFL to 10.00mtr height.
Plastering above +10.00mtr to 13.00mtr height.
Plastering above +13.00mtr to 16.00mtr height.
Providing and mixing the water proofing chemical in cmenet works by weight of cement used for plastering or concrete works, etc., all complete as directed by Engineer-in-Charge.
Providing and applying internal wall and ceiling painting with two coats of premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50grams / litre after applying white cement based putty of average thickness 1mm over the plastered wall surface including preparation of the surfces, with a coat of low VOC primer with emery paper to bring to smooth and even including applying additional coats wherever required to achieve even shade and colour of approved brand, etc., all complete as directed by Engineer-in-Charge.
Providing and Finishing walls with Acrylic Smooth exterior paint of required shade for New work (Two or more coat applied @ 1.67 ltr/10Sq m over and including priming coat of exterior primer applied @ 2.20 kg/10Sq m) including scrapping, preparationof surface for completing the work, etc., all complete as directed by Engineer-in-Charge.
Providing and applying synthetic enamel paint for pipes, grills, chequered plate, shutters, etc., in Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture, filling joints, metal patti, etc., all complete as directed by Engineer-in-Charge.
Dismantling 15 to 40mm dia G.I. / CPVC pipe including stacking of dismantled pipes (within 50 metres lead) including making temporary arrangements for continuing ongoing services to toilets / division maintenance, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing bright finished brass hard drawn hooks(coat hooks) and eyes of 300mm size, etc., all complete as directed by Engineer-in-Charge.
Providing and laying integral cement based water proofing treatment (With average thickness of 120mm and minimum thickness at khurra as 65mm) including preparation of surface as required for treatment of roofs, balconies, terraces, etc., consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/Sq m of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-Charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge over 20mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/Sq m of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge. (d) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of [300 x 300]mm square 3mm deep.
Providing and laying 3mm thick APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/Sq m by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints, etc,, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane. Note: A performance guarantee bond for 5 years on non-judicial stamp paper of Rs. 500/- shall be given by the contractor. The 10% of completed value of this item shall be deducted as defect liability deposit and the same shall be returned after successful completion of 5 years from the date of completion of contract / project as a whole. And the same will be released upon Engineer-in-Charge certifiation if the maintenance period is completed.
Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation, etc., all complete as directed by Engineer-in-Charge.
Supplying, filling, spreading & leveling stone boulders of size range 5cm to 20cm, in Rain water recharge pit, in the required thickness, for all leads & lifts, etc., all complete as per direction of Engineer-in-Charge
Supplying, filling, spreading & leveling gravels of size range 5mm to 10mm, in the Rain water recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, etc., all complete as per direction of Engineer in-Charge.
Supplying, filling, spreading & leveling coarse sand of size range 1.50mm to 2mm in Rain water recharge pit, in required thickness over gravel layer, for all leads & lifts, etc., all complete as per direction of Engineer-in-Charge.
Demolishing R.C.C. work / Pavement concrete in all layers and heights by manually / by mechanical means including handing over of usefull steel bars to the user department and disposal of unserviceable material outside HAL upto distance of 10km including loading, cleaning and unloading at designated area as per local authority procedures, etc., all complete as directed by Engineer-in-Charge.
Demolishing brick work in all layer and heights by manually / by mechanical means built in cement mortar including stacking of serviceable material / handing over to user department and disposal of unserviceable material outside HAL upto distance of 10km including loading, cleaning and unloading at designated area as per local authority procedures, etc., all complete as directed by Engineer-in-Charge.
Demolishing stone rubble masonry / kerb stones in all layer and heights by manually / by mechanical means from cement mortars including stacking of serviceable material / handing over to user department and disposal of unserviceable material outside HAL upto distance of 10km including loading, cleaning and unloading at designated area as per local authority procedures, etc., all complete as directed by Engineer-in-Charge.
Construction of granular sub-base (GSB) with material conforming to Grade-II (size range 53mm to 0.075mm) having CBR Value-25 by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density as per specifications, etc., all complete as directed by Engineer-in-Charge.
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid in panels if required and finished with screed board vibrator, vacuum dewatering process and finally finished by floating, brooming with wire brush as per specifications, etc., all complete as directed by Engineer-in-Charge. (Note:- Cement content considered in this item is @ 330 kg/Cu m. Excess / less cement used as per design mix is payable / recoverable separately).
Providing and fixing glass shelf of size [600 x 120 x 5]mm with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40mm long screws, rawl plugs, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing C.P. brass toilet paper holder of approved brand and fixing with screws, rawl plugs, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing beveled edge mirror of size [600 x 450]mm of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing Wall hung half pedestal Vitreous China Wash basin size of approx size [630 x 450]mm fixed with with C.I. brackets / rack bolts, single 15mm C.P. brass pillar taps, 32mm C.P. brass waste coupling of standard pattern, P.V.C. waste pipe with waste fittings of 40mm dia and make it function of approved brand / make, including painting of fittings and brackets, cutting and making good the walls wherever required, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) of approved brand with ISI marked white solid plastic seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all connecting fittings and fixtures to make it operational completely, including cutting and making good to the walls and floors wherever required, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing 8mm dia C.P. / S.S. Jet (Health Fuacet) with flexible tube upto 1 metre long with S.S. triangular plate on walls/Eureopean type W.C. material of approved make and quality, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing white colour wall hung vitreous china battery based infrared sensor operated urinal of approx. size [610 x 390 x 370]mm having pre & post flushing with water (250 ml & 500 ml consumption approx.), having water inlet from back side, including fixing to wall with brackets embedded in cement mortar (1:3), connecting the waste pipe/waste coupling to floor trap with all necessary fittings and accessories like 32mm dia semi-rigid PVC waste pipe (concealed in the wall) including PVC waste fittings, clamps, etc all as per manufacturers specification, etc., all complete as directed by Engineer-in-Charge.
Providing, fixing, testing and commissioning trap ( floor trap ) of approved make with 100 mm inlet and 75 mm outlet of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors , connection with PVC soil / waste pipe, necessary 150 mm thick cement concrete (1:2:4) for embedding the trap,etc.,all complete as directed by the Engineer-in-Charge.
Constructing masonry Chamber [120 x 120 x 100]cm inside, in brick work of 7.5 class designated in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180mm deep ( inside) with chained lid and RCC topslab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design and, etc., all complete as directed by Engineer-in-Charge.
Constructing masonry Chamber [60 x 60 x 75]cm inside or outside (or approx. size as per site condition), in brick work of class designation 7.5. in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing 15mm nominal bore dia C.P. brass bib cock of approved quality conforming to IS:8931, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing Concealed Chlorinated Polyvinyl Chloride (CPVC) pipes of approved brand, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, fixing the pipe with clamps at 1.00m spacing, necessary reducers, tank adaptors, etc., This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints and making good the walls, etc., all complete as directed by Engineer-in-Charge.
15 mm dia
20 mm dia
25 mm dia
Providing and fixing Extrenal exposed Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints, etc., all complete as directed by Engineer-in-Charge.
32 mm nominal dia
40 mm nominal dia
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms (or nearest availabe size and weight), etc., all complete as directed by Engineer-in-Charge.
Providing and placing on terrace (at all floor levels) polyethylene water Storage tanks, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes for tank and make operational for supply of water to all floors with control valves, etc., all complete as directed by Engineer-in-Charge.
Providing and laying manually or mechanical means Non pressure NP-3 class (Medium duty) R.C.C pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2(1Cement :2 Finesand) inlcuding testing of joints and completing the work, etc., all complete as directed by Engineer-in-Charge.
450mm dia RCC pipe
600mm dia RCC pipe
Providing and fixing powder coated aluminium (minimum thickness of powder coating 50 micron) work for ACP cladding doors, windows, ventilators and partitions for fixed and shutters with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, including cleat angle, Aluminium snap beading for glazing / paneling, C.P.brass / stainless steel screws, hinges / pivoting, filling up the gaps at junctions with dash fasteners and EPDM rubber / neoprene gasket,accessories to operate the doors, windows, ventilators, etc., all complete as per architectural drawings and the directions of Engineer-in-Charge. (Glazing, paneling to be paid for separately) :
Providing and fixing glazing in aluminium door, window, ventilator, louvers, shutters and partitions, etc., With float glass panes of 5mm thickness (weight not less than 12.50 kg/Sq m) along with EPDM rubber / neoprene gasket, etc., all complete as per the architectural drawings and the directions of Engineer-in-Charge.
Supplying and fixing / erection of minimum 6mm thick toughened glass in Staircase railings, UPVC / Alluminum partitions, doors, windows, etc., as per the architectural drawings including gasket & necessary beedings as per IS standards, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing mineral fibre false ceiling tiles at all heights of size [595 X 595]mm of approved texture, design and pattern with 16mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ? 85%,Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7) in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33mm thick (galvanized @120 gsm) comprising of main T runners of [15 x 32]mm of length 3000mm, cross T of size [15 x 32]mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600mm to form grid module of size [600 x 600]mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50mm long 8mm outer diameter M-6 dash fasteners, 6mm diameter fully threaded hanger rod up to 1000mm length and L-shape level adjuster of size [85 x 25 x 2]mm, spaced at 1200mm centre to centre along main ‘T’. The system should rest on periphery walls / partitions with the help of GI perimeter wall angle of size [24 x 24 X 3000]mm made of 0.40mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the Engineer-in-Charge.
Providing and laying factory made Precast concrete solid blocks of 200mm thickness of grade M10 made of Normal resources / C & D waste from approved manufacturer in foundation and plinth with Cement mortar (1:6) in true line and height including curing, cleaning, etc., all complete as directed by Engineer-in-Charge.
Providing and laying factory made Precast concrete solid blocks of 200mm thickness of grade M10 made of Normal resurces / C & D waste from approved manufacturer in superstructure above plinth level up to roof sheet height with Cement mortar (1:6) including required stagging, each course in true level & racking out joints, curing and cleaning, etc., all complete as directed by Engineer-in-Charge.
Providing and laying half block masonry with factory made Precast concrete solid blocks of 100mm thickness of grade M10 made of Normal resources / C & D waste from approved manufacturer in foundation and plinth with Cement mortar (1:4) in true line and height including curing, cleaning, etc., all complete as directed by Engineer-in-Charge.
Providing and laying half block masonry with factory made Precast concrete solid blocks of 100mm thickness of grade M10 made of Normal / C & D waste from approved manufacturer in superstructure above plinth level up to +10m height with Cement mortar (1:4) including required stagging, each course in true level & racking out joints, curing and cleaning, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing machine moulded Aluminium covering (Powder coated aluminium sheet 2.50mm thick (minimum thickness of powder coating 50 micron) of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8mm dia and 75mm long bolt including providing aluminium washers 2mm thick & 15mm dia, at a staggered pitch of 200mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes, etc., all complete as directed by Engineer-in-Charge.
Supply and Filling the gap in between aluminium frame & adjacent RCC / Brick / Stone work by providing weather silicon sealant (approximate 5mm depth and 5mm width) over backer rod of approved quality as per architectural drawings / site suitable, etc., all complete as directed by Engineer-in-Charge.
Supplying and fixing Motorized G.I. rolling shutter of approved make and made of required size. The curtain shall be constructed from Tata Bluescope / JSW 150 gsm single skinned galvalume steel laths with natural finish of min. 1.25mm thickness and interlocking distance of min 75mm. Side guides shall be made of min. 2 or 3.15mm thick heavy duty TG Galvanised steel, as per the site requirement, along with necessary fixtures like cleats (spacing shall not exceed 0.75m) or supports brackets for attachments to the walls or column by screws or bolts and necessary seals. The size of the guide channels shall be conforming to Is:6248-1979. Single piece G.I. Heavy duty mild steel suspension shaft along with roller of sufficient diameter with springs shall be provided along with necessary hexagonal bracket plate of min 3.15mm thickness, size conforming to Is:6248-1979 and square bar, if necessary. The provision of Pressed galvalume steel hood cover with reinforced bracket as required to suit the shutter width and motor cover with natural finish of min. 0.90mm thick and of reuired shape along with necessary fixtures and stiffeners like angle cleats, angle or flat stiffeners, etc., shall be provided. Bottom profile shall be of G.I. plate with angle stiffner. The bottom rail shall be fixed with extruded rubber bottom seal that shall seal against the floor when the door is fully closed. The CE Certified CRS Compact Gear motorised system shall be indirect drive type along with system power supply wired with industrial plug and three station push button / switch with deadman control and arrangements for inside and outside locking.
Approximate size of shutter [5 X 5]m
Designing, supplying and fixing Truss Less Roof System at approximate 14m height using prepainted galvalume coated steel sheet with minimum Base Metal Thickness 1.20mm and Total coated thickness of 1.25mm which confirms to ASTM A792M as per IS 15961 grade "D', 350MPa' yield strength with coating mass AZM150 to the required arch length/arch rise as per span including anchor fasteners / SDS, washers, epoxy paint lacquers and making provision of clamps @ every 1.2m c/c such that the it can carry the false ceiling load of 10 kg/Sq m and hanging light fixtures, etc., all complete as directed by Engineer-in-Charge. Note: A performance guarantee bond for 5 years on non-judicial stamp paper of Rs. 500/- shall be given by the contractor. The 10% of completed value of this item shall be deducted as defect liability deposit and the same shall be returned after successful completion of 5 years from the date of completion of contract / project as a whole. And the same will be released upon Engineer-in-Charge certifiation if the maintenance period is completed.
Supplying, fixing, testing and commissioning of horizontal lifeline system designed to provide safe access to roof area. The base plate / anchorage shall be designed such that it does not affect the truss less roof system. The system shall have 8 mm SS 316 two line wire system with zinc plated and e-coated steel brackets, detachable travellers, posts and base plates that provide flexible, continuous protection for multiple users working at height. The system shall incorporate an inline shock absorber that minimises loads applied to both the user and the building in the event of a fall. The rate is inclusive of necessary fittings / fixtures like base plates, start & end posts, intermediate & corner posts, absorbers, tensioner assembly, end assembly, intermediate brackets, extended intermediate bracket for gutter and ridge connections, corner bracket, aluminium rivets with specially designed EPDM washer to ensure water tightness, water proofing sealant tape, PPE - body harness and 2m dual lanyard, etc., all complete as per manufacturer's specifications and as directed by the Engineer-in-Charge. Note : The quoted rate shall be for the entire work including testing the rope system at site after fixing and nothing extra shall be paid on this account.
Supplying, fabricating, fixing and commissioning in position industrial sliding door / MS sliding door of approximate opening size [15 X 5.50]m as per site requirement with motorisation and option for manual operation with one wicket door option. The sliding door shutters to be puffed covered with not less than 0.50mm thick sheet, etc., with view window of size not less than [500 x 500]mm. The sliding door to be completed with all fittings and fixtures, locking facility, suitable motorisation, guiding sections, rollers, bearings, etc., all complete and including painting with two coats of synthetic enamel paint over a coat of approved red oxide primer, preparation of surface, etc., all complete as directed by EIC. [Shop drawings to be provided by the agency and to be approved by EIC before execution]. TECHNICAL SPECIFICATIONS 1. Shutters: Modular door shutters designed to withstand wind load and all types of impact load as per IS 875 (Part-3) & IS 800 (LSW). 2. Roller wheels: Each shutter shall be supported at the top and bottom on 2 heavy duty roller wheels of size specially designed to run on top / bottom track. The wheels shall be of EN-9 grade steel as per IS 3177 with shafts & supporting bracket plates. The wheels are of double flanged type and will be in single piece without any tyre. Each wheel shall have two nos of antifriction self lubricating maintenance free ball bearings. 3. EPDM / Neoprene rubber gasket shall be applied in between horizontal & vertical gaps of door leafs and at the centre to make door airtight and dust free. 4. Cleats: Cleats made of MS section shall be fixed on top guide to protect door leafs from falling down in case top wheel fails.
Rupees Five Crore Thirty Three Lakh Eighty Seven Thousand Five Hundred Fifty Eight and Two Paise Only
Supply, fixing to/suspending from existing MS perlins/ ceiling at approx. 10-12 mtr height, including using suitable MS angle frame work with required fixing hardwares etc., as per site requirement, testing & commissioning of industrial type highbay LED lighting fixture of wattage not exceeding 150watts made out of high pressure diecast aluminium housing, diffuser made of high grade toughened glass, integral control gear, eye hook etc., (as per OEM standards). The technical parameters of lighting fixtures are as below: The luminaire should have Lumen efficacy ≥ 160lm/watt and lumen output not less than 24000lumens, PF>0.90 and Colour temprature shall be ≥5700K, THD <10%, operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V including necessary interconnections between driver and lighting fixtures and other standard accessories complete in all respects and as directed by Engineer in-charge. The fitting shall be of Bajaj model no:Novabay 150W WH NB PC SD XE / Equivalent model in other approved makes. LED used in the lighting fixtures should be one of the approved make. LM79 certification for luminares & LM80 certificate for LED shall be produced.
Supply, fixing to existing MS perlins at approx. 6 mtr height, including using suitable MS angle frame work with required fixing hardwares etc., as per site requirement, testing & commissioning of industrial type highbay LED lighting fixture of wattage not exceeding 100watts made out of high pressure diecast aluminium housing, diffuser made of high grade toughened glass, integral control gear, eye hook etc., (as per OEM standards). The technical parameters of lighting fixtures are as below: The luminaire should have Lumen efficacy ≥ 160lm/watt and lumen output not less than 16000lumens, PF>0.90 and Colour temprature shall be ≥5700K, CRI≥70, THD <10%, IP66/65 operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V including necessary interconnections between driver and lighting fixtures and other standard accessories complete in all respects and as directed by Engineer in-charge. The fitting shall be of Bajaj model no: Novabay 100W WH NB PC SD XE/ Equivalent model in other approved makes. LED used in the lighting fixtures should be one of the approved make. LM79 certification for luminares & LM80 certificate for LED shall be produced.
Supply, fixing directly to the ceiling/wall using suitable mounting arrangements testing & commissioning of surface mounting Decorative type 10W LED mirror light fitting, including driver, the driver shall have PF >0.9 and Colour temprature shall be ≥5700K, THD <20% operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V including necessary interconnections complete in all respect and as directed by EIC. The lighting fixture shall be Bajaj make Model-BCLSB 10W WH/Equivalent make in other approved makes.
Supply, fixing to existing MS perlins/RCC roof at approx. 6 mtr height, including using suitable MS angle frame work with required fixing hardwares etc., as per site requirement, testing & commissioning of industrial type Flameproof type LED Flood light fixture of wattage not exceeding 80 Watts.The technical parameters of Flame proof Flood light fixtures are as below: The lumiare should have Lumen efficacy >100 lm/watt and lumen output not less than 8000 lumens with symmetric beam Angle 90 degree using suitable optics, PF >0.9 and Colour temperature shall be >6500K, IP66 rated operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V including necessary interconnections between driver and lighting fixtures. Flameproof cum Waterproof LED Flood light fitting Flat Type COB Model Multipile Chip in cast Allum Alloy LM-6 Construction suitable for 80 W LED flood light fixture certified by CIMFR Dhanbhad for gas group I I A , I I B and I I C for zone ZONE 1 & 2 & Zone 21 & 22 and other standard accessories complete in all respects and as directed by Engineer in-charge. The Flame proof Flood Light fitting shall be of model SUDHIR make Cat no: WG/1240 or Equivalent model in other approved makes. LED used in the lighting fixtures shall be one of the HAL approved make.Test certificate for luminares and for LED shall be produced.
Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range-5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K(As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) as per CPWD.
18- 22 Watt LED Batten light
40 Watt LED Batten light
Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) as per CPWD.
45 watt LED building light fixture
Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%,Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim as per CPWD .
18 Watt LED Down lighter
Supply & fixing on wall using suitable mounting arragements, fixing hardwares, testing and commissioning of 450mm dia, Air Circulator wall mounting, oscillating type fan along with speed regulator, power cord with 6A, 3 pin plug top and other connected accessories etc., including necessary interconnections complete in all respects and as directed by the Engineer-in-charge.
Supply, installation, testing & commissioning of 300mm dia 1400 rpm heavy duty exhaust fan of any approved make with louvers, connecting cord with 6A, 3 pin plug top and with all necessary accessories, including making wall openings and replastering to smooth finish with matching paint etc., complete in all respects and as directed by Engineer-in-charge.
Supply, installation, testing & commissioning of 450mm dia 1400 rpm heavy duty exhaust fan of any approved make with louvers, connecting cord with 6A, 3 pin plug top and with all necessary accessories, including making wall openings and replastering to smooth finish with matching paint etc., complete in all respects and as directed by Engineer-in-charge.
Supply, installation, testing & commissioning of 610mm dia 1440 rpm industrial heavy duty flame proof exhaust fan of any HAL approved make with louvers with all necessary accessories including making wall openings to mount the exhaust fan and replastering to smooth finish after fixing etc, including suitable ventilating louvers complete in all respects and as directed by Engineer-in-charge.The flame proof exhaust fan shall be certified by CIMFR Dhanbhad for gas group I I A , I I B and I I C for zone ZONE 1 & 2 & Zone 21 & 22. The Flame proof exhaust fan shall be of model SUDHIR make Cat no: EF / 140 or Equivalent model in other HAL approved makes.Test certificate for flame proof exhaust fan shall be produced.
Design, fabrication, Supply, erection, testing & commissioning of Main LT PANEL (PTTA)
Incomer
1No - 400A, 415V gr. 4P 36KA MCCB TM Based
Lot - 500A TP + 250 N, 415V, short circuit rated 36KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
1No- Multi function meter (MFM/MDM) suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1, RS 485 Port Digital MFM/MDM of EM6400NG of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
1Set of - 400/5A current transformers of class and VA burden for metering.
1Set - RYB indicating lamps of LED module with 6A SP MCB.
1Set- 6A, MCB for the protection of measuring instruments.
Outgoings
2 Nos -250A 415V gr. 4P 36KA MCCB TM Based
2-Nos 63A 415V gr. 4P 25KA MCCB TM Based
12 Nos - 32A 415V gr. 4P 25KA MCCB TM Based
Design, fabrication, Supply, fixing on wall/ grouting on floor 600mm above the ground level using suitable angle iron frame work, testing and commissioning of 125A 415V gr 4P 36KA MCCB TM Based with suitable 200A, 4P, 415V, short circuit rated 36KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc,RYB indicating lamps of LED module, powder coated, with adjustable thermal settings (80% to 100%) housed in suitable sheet steel enclosure, including suitable Incoming and Outgoing LT cable end box wherever necessary complete in all respects and as directed by Engineer-in-charge.
Supply, fixing, testing & commissioning of the following factory built powder coated Double door MCB/MCCB DB of any approved make fabricated out of M.S. sheet steel enclosure & necessary cutouts for operating the MCB knobs & comprising of 200 amps tinned copper busbars & earthing bus with tapped holes including internal wiring with stranded copper PVC wires or suitable size copper strips etc. & fixing the DB in flush with wall/ on wall as per site requirement with necessary M.S. angle supports, chipping the wall and replastering to smooth finish etc., wherever required as per site condition, complete in all respects, as directed by Engineer-in-charge and comprising the following as detailed below:
6 way (4 + 18), Horizontal Double door TPN MCB DB
4 way (4 + 12), Horizontal Double door TPN MCB DB
Supply, installation, testing & commissioning 4 Way Horizontal Type 4P Flame Proof MCB lighting distribution board with die cast Aluminium alloy with all necessary accessories using suitable angle iron frame work.The flame proof LDB shall be certified by CIMFR Dhanbhad for gas group I I A and I I B for zone ZONE 1 & 2 & Zone 21 & 22. The Flame proof LDB shall be of model SUDHIR make Cat no: MCDB / 186 & RCP / 215 or Equivalent model in other HAL approved makes.Test certificate for flame proof LB shall be produced.
32 amps. ratings, 4P MCB, "C" curve, 10 KA breaking capacity.
6-32 amps. ratings, SP MCB, "C" curve, 10 KA breaking capacity.
Wiring for light point / fan point / exhaust fan point/call bell point from nearest switch box with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, fan regulator, modular plate, ceiling rose, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. (as per detailed CPWD specifications for Group C wiring)
Wiring to single light point controlled by 1 No 6A, 250V gr. flush type modular SP switch complete in all respects.
Wiring to two light point controlled by 1 No 6A, 250V gr. flush type modular SP switch complete in all respects.
Wiring to three light point controlled by 1 No 6A, 250V gr. flush modular type SP switch complete in all respects.
Wiring to exhaust/wall mounting fan point using 6A, 250V gr. flush type modular SP switch housed along with other lighting switches/separate switch box if required and 3pin 6A, 250V gr. modular type socket housed near the exhaust fan complete in all respects.
Supplying and fixing following suitable size GI/PVC Box with modular plate and cover on front on surface or in recess, including providing and fixing 3 pin 5/6A modular socket outlet and 5/6 A modular switch, connections etc., as required.
Supplying and fixing following suitable size GI/PVC Box with modular plate and cover on front on surface or in recess, including providing and fixing 6 pin 5/6A & 15/16A modular socket outlet and 15/16 A modular switch, connections etc., as required.
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. asrequired.
Supply, Installation, Testing & commissioning of Flameproof type 25 A Double Pole rotary switch with termination chamber with all necessary accessories using suitable angle iron frame work.The flame proof DP rotary switch shall be certified by CIMFR Dhanbhad for gas group I I A and I I B for zone ZONE 1 & 2 & Zone 21 & 22. The Flame proof LDB shall be of model SUDHIR make Cat no: RI/OA/1010 or Equivalent model in other HAL approved makes.Test certificate for flame proof LB shall be produced.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required as per CPWD.
3 x 2.5 sq. mm (For lighting ckt from DB to Switch box)
3 x 4 sq. mm(For 6A & 16A power points)
Supply & laying in the already excavated cable trench/cable tray/fixing on wall/duct wall with necessary M.S clamps / encasing in pipes etc., testing & commissioning of following size XLPE insulated Aluminium (Al) conductor(stranded) 1.1 KV grade confirming to IS: 7098 ( part-I)/1998 with upto date amendment earthed Armoured (Arm)U.G cables and as per technical specification including stacking at site, proper storage complete etc., as required. (Note:- Excavation, sand & Brick Protection, concrete cutting, reconcreting, casing pipes will be measured separately.)
4CX 16 Sqmm Aluminium armoured conductor
3.5CX 95 Sqmm Aluminium armoured conductor
3.5CX 185 Sqmm Aluminium armoured conductor
Supply & laying in the already excavated cable trench/cable tray/fixing on wall/duct wall with necessary M.S clamps / encasing in pipes etc., testing & commissioning of following size XLPE insulated Copper (cu) conductor 1.1 KV grade confirming to IS: 7098 (part-I)/1998 with upto date amendment earthed Armoured (Arm) U.G cables and as per technical specification including stacking at site, proper storage complete etc. as required. (Note:- Excavation, sand & Brick Protection, concrete cutting, reconcreting, casing pipes will be measured separately.)
3C X 2.5 Sqmm Copper armoured conductor LT control Cable
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE armoured aluminium conductor cable of 1.1 KV grade as required
4CX16Sqmm Al Arm LT Cable End Joint
3.5 CX 95 Sqmm Al Arm LT Cable End Joint
3.5 CX 185 Sqmm Al Arm LT Cable End Joint
3CX 2.5 Sqmm Copper armoured conductor
Supply, Installation, Testing & commissioning of Flameproof type cable gland double compression gland 1 inch.with all necessary accessories.The flame proof cable gland shall be certified by CIMFR Dhanbhad for gas group I I A and I I B for zone ZONE 1 & 2 & Zone 21 & 22. The Flame proof cable gland shall be of model SUDHIR make Cat no: CAT NO.-CG/209 or Equivalent model in other HAL approved makes.Test certificate for flame proof cable gland shall be produced.
Supply, fabricating and installing of Following size perforated GI cable trays with cover including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling/fixing to the wall/RCC beam/iron structures as per site requirement complete in all respects and as directed by Engineer in charge. (Note:-M.S. angle supports will be measured separately).
Supply & fixing of 100 x 50 x 2mm thick with 1.6mm thick cover cable trays
Supply & fixing of 300 x 50 x 2mm thick with 1.6mm thick cover cable trays
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
20MM PVC Conduit
25MM PVC Conduit
Carrying out Mechanized Horizontal directional drilling(HDD) of soil under the existing road/gate way for laying 2runs of HDPE pipe including supply and laying 2 run of 110 mm dia PE100 PN08 HDPE pipes with ISI mark and conforming to IS 4984:1995 including suitable jointing using welding as required, providing pull tapes in the laid HDPE pipe, ends brought out, the brought out ends shall be sealed with suitable material to prevent soil and water entry and buried under soil. A cement concrete route marker shall be grouted in the soil above both the end of pipes with mark "End of pipes 2Rx110mm"complete as directed by Engineer in charge.
Carrying out Mechanized Horizontal directional drilling(HDD) of soil under the existing road/gate way for laying 1runs of HDPE pipe including supply and laying 1 run of 75 mm dia PE100 PN08 HDPE pipes with ISI mark and conforming to IS 4984:1995 including suitable jointing using welding as required, providing pull tapes in the laid HDPE pipe, ends brought out, the brought out ends shall be sealed with suitable material to prevent soil and water entry and buried under soil. A cement concrete route marker shall be grouted in the soil above both the end of pipes with mark "End of pipes 1Rx110mm"complete as directed by Engineer in charge.
TIMER PANEL
Supply, installation, testing and commissioning of Outdoor weather proof 2rows 24 module module distribution board of Hensel Cat. No.KV 9224 M or equivalent in Legrand/ Hager/ Schneider make including suitable locking facility by means of built in lock with profile cylinder with set of Key's and with suitable size cover, cable entry on one side. The DB shall be mounted at suitable height on the wall using suitable size MS angle/channel frame work with painting as per EIC, with cable entry knock-outs, including rigid support for all components, required fasteners totally enclosed, dust and vermin proof and degree of protection shall not be less than IP-65 with necessary interconnections between incoming and outgoing MCB's, contactor and timer using suitable size flexible copper wires and comprising of following switchgear and accessories complete in all respects and as directed by Engineer-in-charge.
1No- Modular digital time switch for street light & Building light control of Legrand Alpha Rex 3 D21 or equivalent approved make with one channel daily cycle unit suitable for daily programming to switch ON & OFF and operate on 230V single phase supply.
1No- 32A 230V gr.10KA 4P MCB with overload and short circuit protection.
1No-25A, Modular type Power contactor with suitable NO & NC to operate on 230V Single phase supply.
3Nos, 6-32A, 230V Gr, 10KA SP MCB with overload and shortcircuit protection.
Supply and fixing of weather proof cable junction box with terminals of size 104 mm x 104 mm x 70 mm Hensel Cat. No. DK 0402 G or equivalent in Legrand/ Schneider/ Hagar make only. The Box shall be mounted on the wall/truss using suitable size MS angle frame work(including) with painting as per EIC, with cable entry knock-outs, including rigid support for all components, Din channel, required fasteners totally enclosed, dust and vermin proof and degree of protection shall not be less than IP-65 complete in all respects and as directed by Engineer-in-charge.
Supply, fixing/embedding on wall/ ceiling flame proof 4 way junction boxes of entry size 3/4" ET, 100 mm dia, 60 mm depth of Die cast Aluminium alloy material including necessary accessories for fixing as per site conditions and as directed by Engineer In-Charge.
Supply & fixing on the top of the building 3 pronged lightning conductor finials fixed on 20 mm dia copper tube 2 mtrs, long with gun metal of 150 mm dia. Including Base & fixing arrangements for the down conductors etc., complete as per standard practice.
Supply & fixing above the building on 1200mm long 25mm dia GI pipe frame work testing and commissioning of 2 Nos of 10W LED light,IP65 aviation obstruction LED lights fixtures of Bajaj Cat No. BGAV 302 LED-110731 or Equivalent model in other HAL approved makes including necessary interconnections complete in all respects.
Telephone
Supply, Fixing, in the existing GI /PVC box as per site requirement, testing & Commissioning of 1 No. Twin RJ-11 telephone socket outlets with shutter with necessary interconnections complete as directed by Engineer-in-charge.
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
Supply & drawing of 0.5 mm dia copper conductor PVC insulated 4 pair colour coded and twisted unarmoured telecommunication cables in the existing PVC conduit as per standard practice including necessary inter connections & end terminations.
Supply & fixing on wall/grouted to floor upto 1200mm above ground level as per site requirement using suitable size MS angle iron frame work finished with two coats of enamel spray paint over a good primer & providing 10 pair krone type telephone connector junction box including krone connector with necessary mounting frame housed in suitable size FRP/SMC box with hinged lockable cover complete in all respects.
Supply, laying in the already excavated cable trench/existing duct/fixing on wall/cable tray/iron structure using suitable clamps etc./ encasing in pipe, testing and commissioning of 10 pair jelly filled armoured copper conductor of 0.5mm dia polyethylene insulated cover, twisted into pairs, colour coded, pairs laid up, fully filled with petroleum jelly as a moisture barrier, core wrapped with non-hygroscopic polyester tape to contain the jelly, covered with aluminium poly-laminates screen, polyethylene sheath extruded over aluminium screen, polyethylene tape over the above sheath, armoured with galvanised steel tape and outer polyethylene sheath underground telecommunication cable including both end terminations on the existing krone type junction box complete in all respectsand as directed by Engineer-in-charge.
IT Works
Supply & fixing in flush with existing GI/PVC Modular box as per site requirement, testing & Commissioning of 2 no's 1 Module RJ-45 socket in Module plate for Two number of Data point with necessary interconnections complete as directed by Engineer-in-charge.
Supply and drawing in the existing PVC conduits / wall / above false ceiling, Cat 6 UTP 4-Pair cable including necessary interconnections complete for LAN & Internet point as directed by Engineer-in-charge.
Supply and fixing of 24 Port LIU fiber LC style singlemode, 19-inch Rack mount Patch panel with adapter plates, fiber pig tails, Fully loaded including splicing. complete in all respects and as directed by Engineer-in-charge. Approved Make:COMMSCOPE TYCO/ PANDUIT/ MOLEX
Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel as per CPWD.
Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm wit 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.( as per CPWD specification).
9U Rack
Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature shall be – 5 0C to +50 0C, Max Attenuation ± 0.36 (db / km) at Operational Wavelength 1310 nm and ± 0.22 db / km at Operational Wavelength 1550 nm. type of fiber should be 9/125/G.652D & Refractive Index should be 1.4670/1.4675. The value for Mode-filed, Cladding Diameter 9.2 ± 0.4 μm and 125 ± 0.7 μm correspondingly. The Dispersion value < 3.5 < 18 ps/nm-km and PMD value < 0.2 ps/km and Cable Cutoff wavelength < 1260 nm i/c splicing & marking etc complete as required. (As per CPWD Specification).
Single Mode 6 Core Optical fiber cable
Earthing
Supply, providing and Fixing Cast Iron Pipe earth station confirming to IS 3043 complete with 2750mm long, 100 mm Inner Dia(ID),13mm thickness CI Pipe, with 2 part clamp made out of G I flat 50 x 6 mm continuously welded around the pipe using cast iron welding electrodes as per drawing. The cost also incudes excavation for earth pit, providing & laying homogenous mixture of charcoal lumps, salt & sand all around the pipe as per specification, supplying and fixing of RCC Collar of size 450 mm dia, 450 mm height and 50 mm thick over Cement concrete base of minimum size 150mm width & 100mm thick all around below collar shall be provided using 1:2:6 CC after necessary excavation, refilling of soil, consolidating, ramming, leveling of soil etc., supplying & fixing the label board(MS Plate of size 300mmx200mmX2mm) welding to the electrode complete as per specification, std drawing, instructions of EIC.
Supply, fixing & connecting the 50X6mm size G.I strip on wall / clamping to the existing duct wall / fixing on steel structures/ laying 2 ft. below the ground level with necessary excavation, concrete cutting & re-concreting, refilling, consolidation & levelling of soil after laying for interconnection between the earth pits and the LT & HT panels earthing & Transformer body earthing as directed by Engineer-in-charge. Note:- Excavation, concrete cutting & re concreting will be measured separately.
Supplying & laying 25 mm X 5 mm GI strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50mm)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan). Including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil & refilling the same soil and disposal of surplus excavated soil as directed, with in a lead of 50m as per CPWD specification.
Concrete cutting/Chipping/Bitumen Road the existing 1:2:4 cement concrete road /pavements / flooring / rock/stone etc., including removing debris from the work site and depositing in the place as directed by EIC
Re-concreting the cut portion/closing the dummy cable duct at same area with 1:2:4 cement concrete by employing 20mm graded aggregate granite to smooth finish including curing and form work if any complete in all respects and as directed.
Design, Fabrication, Supply and fixing/grouting in wall/ceiling of suitable size MS angle iron supports/ flat for cable tray supports as per site requirement and painting the same with two coats of synthetic enamel paint over a coat of zinc chromite primer complete in all respects and as directed by EIC/OIC.
Rupees Twenty Seven Lakh Thirty Three Thousand Eight Hundred Ninety Nine and Sixty One Paise Only
Two Loop Panel.
Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections with remote test features etc complete as required. As per CPWD Specification.
Supplying, installation, testing & commissioning of addressable manual call point complete as required. As per CPWD Specification.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. As per CPWD Specification.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. As per CPWD Specification.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. As per CPWD Specification.
Supply, Installation, testing and commissioning of Auto Dailer including the cost of mounting accessories with addressable control module integrated with main control panel with minimum 10 telephone nos. connectivity complete as directed by Engineer-in-charge.
Supplying, installation, testing & commissioning of fault isolator complete with base as required. As per CPWD Specification.
Supplying & laying of 2x1.5 sqmm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. As per CPWD Specification.
Supply,Installation, testing & commissioning of Triple sensor Flame Detectors with UV/IR detection capacity with Flame proof / Explosion proof enclosure type ,Flickering LED, 4 wire system. 2 wire for Input Supply & 2 wire suitable to connect standard Fire Alarm complete as directed by Engineer in charge and shall comply to BS-5839/EN54/IS2189 standards for installation and product shall be EX & IEICEx Approved.
Rupees Five Lakh Eighteen Thousand Five Hundred Twenty Two and Eighty Paise Only
Supply, installation, testing and commissioning of "Class C " ERW grade GI heavy duty pipes and fittings confirming to IS:1239&1879 for interconnected piping between compressor discharge valve, air dryer, receivers, moisture seperator and filters, internal piping complete as per the drawing and technical specification. The pipes can be laid in the ground/fixing on duct wall/ wall using suitable angle iron supports, clamps etc. Scope of work includes necessary cutting, welding/threading wherever necessary including GI fittings like Flanges, bends, collars, reducers, tees etc., with necessary fixing hardware and painting the same with two coats of synthetic enamel paint over a coats of zinc chromite primer complete in all respects as per technical specifications and as directed by EIC/OIC. The scope includes wall opening and finishing if any. Note:MS supports shall be measured seperately.
40 mm dia NB pipe
15 dia NB pipe
Supply, welding/threaded, testing & commissioning of 40mm dia Butterfly Valve.
Supply, welding/threading, testing & commissioning of 15mm dia 3 piece SS ball (socket type) valves regular bore, lever operated, body and end connectors of carbon steel including operating handle for the compressed air outlet.
Supply, welding/threading, testing and commissioning of 15mm dia quick release single coupling for the compressed air outlets consisting of both socket and plug for hose pipe of 6mm dia & suitable for working pressure of 7.0bar complete in all respect.
Supply, welding/threaded, testing & commissioning of compressed air Automatic liquid drain trap of 15mm dia.
Supply, installation, testing and commissioning of Pressure gauge 2" dial with 15NB isolation valve inclluding all accessories complete and as directed by EIC.
Design, Fabrication, Supply and fixing/grouting in wall of suitable size MS angle iron supports/ flat/ brackets as per site requirement for painting the same with two coats of synthetic enamel paint over a coat of zinc chromite primer for supporting the compressed air line complete in all respects and as directed by EIC/OIC.
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N as per CPWD specifications.
Rupees Five Lakh Eighty Nine Thousand Thirty One and Eighty Two Paise Only
Supplying and fixing Dry Chemical powder type Fire extinguisher of 6 Kg Capacity Cartridge type, fitted with min 60 grams capacity CO2 gas cartridge strictly manufactured to IS: 4947 Std, provided with MAP dry powder manufactured to IS: 14609 Std, provided with controllable discharge mechanism with discharge nozzle, with suitable wall mounting clamps, epoxy polyester powder coated strictly manufactured to IS: 15683 Std suitable for A, B & C - Class of Fire. In addition to above extinguisher to be supplied with a Spare CO2 Gas cartridge suitable for each DCP Type Fire extinguisher
Supplying and fixing Carbon Di-Oxide (CO2) type Fire Extinguisher of Capacity 4.5 Kgs conforming to IS: 15683-2006 with CCOE /PESO Approval Initial Filling : Pure CO2 Gas. Material of Cylinder : The cylinder shall be made from brand new seamless cylinders confirms to IS: 7285, ISI MARK Valve confirming : IS: 3224. Design, Construction & Testing : As per IS: 15683, Fitted with discharge hose with horn along with standard accessories. The body shall be externally powder coated with PO Red shade. Suitable wall mounting clamps & standard accessories are required to be supplied along with supplied Fire extinguishers. The extinguishers shall be suitable for B, C & Electrical Fire.
Rupees Eighty Thousand One Hundred Thirty Five and Fifty Paise Only
Rupees Thirty Nine Lakh Twenty One Thousand Five Hundred Eighty Nine and Seventy Three Paise Only
Rupees Five Crore Seventy Three Lakh Nine Thousand One Hundred Forty Seven and Seventy Five Paise Only
Approximate Amount Put to Tender
Rupees One Crore Three Lakh Fifteen Thousand Six Hundred Forty Six and Fifty Nine Paise Only
Rupees Six Crore Seventy Six Lakh Twenty Four Thousand Seven Hundred Ninety Four and Thirty Five Paise Only
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
raw.json
RAW_JSON
TN125.pdf
TENDER_DOCUMENT • 0.45 MB
ElectricalTenderDrawings.pdf
TENDER_DOCUMENT • 2.34 MB
139ECSForm.pdf
TENDER_DOCUMENT • 0.48 MB
139CHECKLIST.pdf
TENDER_DOCUMENT • 0.19 MB
139PBF.pdf
TENDER_DOCUMENT • 0.74 MB
139PQnew.xlsm
TENDER_DOCUMENT • 0.04 MB
139PB.xlsm
TENDER_DOCUMENT • 1.08 MB
139PQF.pdf
TENDER_DOCUMENT • 0.20 MB
139TBF.pdf
TENDER_DOCUMENT • 4.31 MB
CivilTenderDrawing.pdf
TENDER_DOCUMENT • 0.27 MB
139UNDERTAKING.pdf
TENDER_DOCUMENT • 0.57 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .