Executive Engineer Electrical BSNL Gorakhpur
Telephone Exchange Raptinagar Gorakhpur
Shifting, redeployment and down sizing of Diesel Engine Alternator sets of different capacity from T. Exch. Sahadatganj to Akbarpur and Akbarpur to Main Exch Civil Lines Ayodhya, in OA Ayodhya.
2023_BSNL_169149_1
13/TED/GKP/2023-2024
Open Tender
Electrical Works
Item Rate
30 days
Ayodhya
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
ACCOUNTS OFFICER(Cash)BSNL O/o The GMTD GORAKHPUR
₹2,255
2 Dec 2023
29 Sept 2023
12 Oct 2023
29 Sept 2023
10 Oct 2023
29 Sept 2023
SUB HEAD-I (Minor repairing of DG at TE Sahadatganj) 1. Supply and fixing of Hose pipes kit for 15 KVA DG set etc complete as required.
2. Supply and fixing of coupling clip of Hose pipes for 15 KVA DG set etc complete as required.
3. Supply and fixing of steel wire braded fuel pipes with both end junction bolts for priming pump, filter and main pump etc. in 15 KVA DG set etc complete as required.
4. Supply and fixing of returning fuel pipe (54inch long) for 15 KVA DG set etc complete as required.
5. Supply and fixing of V- Belt for DC alternator etc complete as required.
6 Dismantling, repairing of 12 volts DC alternator for 120AH 12Volt battery charging of 15KVA DG set including wiring, refixing etc complete as required.
7. Repairing of Self Starter of 15KVA set i/c replacement of carbon brushes, copper bush and replacement of 12 volts broken solenoid with new one etc. complete as required.
8. Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size Upto 35 sq. mm on wall surface as required.
9. Supplying and making end termination with aluminium lugs for 4x16 sq mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
10. Dismantling and refixing of change over switch on the wall i/c grouting and fixing with nuts and bolts i/c connection, testing and commissioning etc. as reqd. (make:-Havells, HPL or S/S make)
SH-II ( T. Exch Sahadatganj to T Exch Akbarpur) 11. Dismantlling of the 62.5 KVA DEA set at T. E. Sahadatganj i/c dismantlling of the exhaust pipe, cable, fuel tank, control panel etc. complete as reqd.
12 Loading of the above E/A set by using the crane/ lifting pulley or manually at Tel. Exch. Sahadatganj including pulling out from DG room / foundation etc complete as required.
13. Shifting of the above Diesel engine alternator set with exhaust pipe, cable, fuel tank, control panel etc from Tel exchange Sahadatganj to Tel Exch Akbarpur etc. complete as reqd..
14. Unloading of the above E/A set with exhaust pipe, cable, fuel tank, control panel etc by using the crane/ lifting pulley or manually at T Exch Akbarpur including pushing / placing in the DG room and DG foundation placing the DG set etc complete as reqd.
15. Installation of the above 62.5KVA DEA set at T. Exch. Akbarpur i/c installation of exhaust pipe, cable, fuel tank, control panel etc. connection of cables, earthings as reqd.
16. Supply and fixing of Hose pipes kit for 62.5 KVA DG set etc complete as required.
17. Supply and fixing of coupling clip of Hose pipes for 15 KVA DG set etc complete as required.
18. Supply and fixing of steel wire braded fuel pipes with both end junction bolts for priming pump, filter and main pump etc. in 15 KVA DG set etc complete as required.
19. Supply and fixing of returning fuel pipe (54inch long) for 15 KVA DG set etc complete as required.
20. Supply and fixing of V- Belt for DC alternator etc complete as required.
21. Dismantling, repairing of 12 volts DC alternator for 120AH 12Volt battery charging of 15KVA DG set including wiring, refixing etc complete as required.
22. Repairing of Self Starter of 15KVA set i/c replacement of carbon brushes, copper bush and replacement of 12 volts broken solenoid with new one etc. complete as required.
23. Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size Upto 95 sq. mm on wall surface as required.
24. Supplying and making end termination with aluminium lugs for 3.5x95 sq mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
SH-III ( Tel. Exch Akbarpur to Tel Exch Civil Lines Faizabad) 25. Dismantlling of the 180 KVA DEA set at T. E. Akbarpur i/c dismantlling of the exhaust pipe, cable, fuel tank, control panel etc. complete as reqd.
26. Loading of the above 180KVA E/A set by using the crane/ lifting pulley or manually at Tel Exchange Akbarpur including pulling out from DG room / foundation i/c loading of exhaust pipe, control panel, fuel tank, fuel pipie etc complete as required.
27. Shifting of the above Diesel engine alternator set with exhaust pipe, cable, fuel tank, control panel etc from Tel exchange Akbarpur to Tel Exch Civil Lines Faizabad etc. complete as reqd..
28. Unloading of the above 180KVA E/A set by using the crane/ lifting pulley or manually at Tel Exch Civil Lines Faizabad including pushing / placing in the DG room and DG foundation placing the DG set etc complete as reqd.
29. Installation of the above 180 KVA DEA set at Tel Exch Civil Lines Faizabad i/c installation of exhaust pipe, control panel, fuel tank, fuel pipe etc. including connections of cables, earthing etc as reqd.
30. Servicing of 180 KVA make DG set including replacement of consumables i.e. Lub oil, Lub oil filters, diesel filters, bypass filters, coolant, air filters etc. (Make & item should be manufacturer's recommended)
31. Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size Upto 185 sq. mm on wall surface as required.
32. Supplying and making end termination with aluminium lugs for 3.5x185 sq mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .