Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹34.7 L+₹1.5 L (4.61%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 Bidder | |
| 3 | L3₹36.8 L+₹3.6 L (10.8%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 Bidder | |
| 4 | L4₹38.4 L+₹5.2 L (15.8%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 Bidder | |
| 5 | L5₹39.4 L+₹6.2 L (18.6%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 Bidder |
| Sl No | Description | Qty | Unit | M/s AKHIL SHARMA L2 | vmd traders L1 | M/S SUSHEEL KUMAR Govt. CONTRACTOR L4 | M.S Sharma Enterprises L5 | HIMALAYA ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavating over area , exc 1.5 deep and getting out in any type of soil, complete all as specified and as directed. | 15 | Cum | 100 ₹1,500 | 200 ₹3,000 | 95 ₹1,425 Lowest | 190 ₹2,850 | 100 ₹1,500 |
| 2.00 | Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, & n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in any type of soil, complete all as specified and as directed. | 10 | Cum | 100 ₹1,000 | 200 ₹2,000 | 95 ₹950 Lowest | 190 ₹1,900 | 100 ₹1,000 |
| 3.00 | Returning, filling incl spreading leveling watering and well ramming in layers not exceeding 25mm in any type of soil complete all as specified and as directed. | 7.5 | Cum | 50 ₹375 | 200 ₹1,500 | 48 ₹360 | 10 ₹75 Lowest | 100 ₹750 |
| 4.00 | Removing excavated material (soils) exceeding 250 m but n.exc. 500m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. | 7 | Cum | 50 ₹350 | 200 ₹1,400 | 48 ₹336 | 10 ₹70 Lowest | 100 ₹700 |
| 5.00 | Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed. | 920 | Sqm | 5 ₹4,600 | 5 ₹4,600 | 4 ₹3,680 Lowest | 5 ₹4,600 | 10 ₹9,200 |
| 6.00 | Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 Square Metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt ), all as specified and directed by Engineer-in Charge. | 36 | Each | 50 ₹1,800 | 50 ₹1,800 | 45 ₹1,620 | 10 ₹360 Lowest | 100 ₹3,600 |
| 7.00 | Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), all as specified and directed by Engineer-in Charge. | 4 | Each | 50 ₹200 | 50 ₹200 | 45 ₹180 | 10 ₹40 Lowest | 100 ₹400 |
| 8.00 | Dismantling cast iron pipe & reinforced concrete drain pipes, jointed in cement mortar of any dia upto 100mm complete all as specified and as directed. | 42 | RM | 5 ₹210 Lowest | 10 ₹420 | 10 ₹420 | 10 ₹420 | 100 ₹4,200 |
| 9.00 | Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish of the premises complete all as specified and as directed. | 955 | Sqm | 10 ₹9,550 | 13 ₹12,415 | 2 ₹1,910 Lowest | 10 ₹9,550 | 20 ₹19,100 |
| 10.00 | Dismantling wall and ceiling boards, fibre pulp insulation etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed. | 390 | Sqm | 5 ₹1,950 | 3 ₹1,170 | 2 ₹780 Lowest | 10 ₹3,900 | 10 ₹3,900 |
Tender Value
₹42.6 L
EMD Value
₹85,500
Closing Date
11 Mar 2026, 6:00 pmClosed
GE SOUTH UDHAMPUR
GE SOUTH UDHAMPUR
SPECIAL REPAIRS OF TOILET AND BATHROOM ALONGWITH TREATMENT OF ROOF IN BLDG NO NP01 AND NP02 UNDER GE SOUTH UDHAMPUR
2026_MES_753223_1
GE/S(U)-123/2025-26
Open Tender
Civil Works
Works
240 days
GE SOUTH UDHAMPUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE SOUTH UDHAMPUR
₹85,500
11 Apr 2026
18 Feb 2026
12 Mar 2026
18 Feb 2026
11 Mar 2026
4 Mar 2026
Excavating over area , exc 1.5 deep and getting out in any type of soil, complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, & n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in any type of soil, complete all as specified and as directed.
Returning, filling incl spreading leveling watering and well ramming in layers not exceeding 25mm in any type of soil complete all as specified and as directed.
Removing excavated material (soils) exceeding 250 m but n.exc. 500m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 Square Metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt ), all as specified and directed by Engineer-in Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), all as specified and directed by Engineer-in Charge.
Dismantling cast iron pipe & reinforced concrete drain pipes, jointed in cement mortar of any dia upto 100mm complete all as specified and as directed.
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish of the premises complete all as specified and as directed.
Dismantling wall and ceiling boards, fibre pulp insulation etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed.
Dismantling of plain or corrugated steel sheeting any gauge and thickness including Nainiital or similar pattern roof coveriongs complete all as specified and as directed.
Dismantling water tanks and removing to store exc 1000 & n.exc 2000 ltrs of capacity complete all as specified and as directed.
Demolition of reinforced cement concrete in roof floor (other than ground floors) beams staircase, landing chajja and similar work complete all as specified and as directed.
Demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Demolition of brick/stone masonry built in CM. complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for including scrubbing down with water etc and disposed of the rubbish from the premisses and necessary wooden props and struts minimum 2 nos per sqm to safe the existing structure complete all as specified and as directed.
Demolition and breaking up drain pipes 150/200mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and as directed.
M&L for 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in floor and finished even and fair complete all as specified and as directed.
M&L for providing cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates for filling in the pressed steel door frame/hold fast complete all as specified and as directed.
Providing cement concrete 1:2:4 type B0 in steps, seismic and other similar bands, parapets and railings up to 60 cm in hieght, coping, kneeless apex stones , bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles complete all as specified and directed.
M&L for Precast cement concrete Block (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as in bond stones set in cement mortor 1:6 all as specified and directed.
M&L for Plain cement conc 1:4:8 type D-2 using 40mm graded agg as in conc bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200mm bore pipes all as specified.(Note- thickness of bed below the barrel of pipes 15 cm and width of bed : Outer diameter of drain pipes (not of sockets/collars) plus 30 cm all as specified and as directed.
M&L for Plain cement conc 1:4:8 type D-2 using 40mm graded agg as in conc bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150mm bore pipes complete all as specified and as directed.
M&L for providing 75 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection and sub base finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and as directed.
M&L PCC 1:5:10 type E2 using 40 mm graded brick aggregate as in filling under sunken floors etc complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and as directed.
M&L for Reinforced cement concrete (Nominal Mix) type B1 1:2:4 using 12.5mm graded stone aggregate as chajjas , slabe or similar works etc completed all as specified and as directed.
M&L for PCC 1:2:4 type B1 (using 20 mm graded aggregate) in surafce channel and drains complete all as specified and as directed.
Providing Precast cement concrete 1:2:4 type B-1 (20mm graded aggregate ) as in manholes cover slab etc all as specified and directed by Engr-in-charge.
M&L for RCC B1 1:2:4 using 20mm graded stone aggregate as slabs supported on walls, beams and columns in floor, roofs, landing, balconies, canopies, deck slabs and in shelves and the like etc. including necessary form work complete all as specified and as directed.
M&L brick work with sub class B bricks straight or curved on plan to any radius built in CM 1:6 complete all as specified and as directed.
M&L brick work with sub class B bricks straight or curved on plan to any radius built in CM 1:6 but except bricks complete all as specified and as directed.
M&L half brick work with sub class B bricks straight or curved on plan to any radius built in CM 1:4 all as specified and directed.
M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted built in cement mortar 1:6 complete all as specified and directed by Engr-in-charge. Note PCC Bond Stone shall be paid separately under appropriate item and volume of bond stone shall be deducted.
All as per item No 34 above but except stone complete all as specified and as directed.
M&L for Rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement including mixing integral water proofing compound in the proportion as mentioned in manufacturer's instructions complete all as specified. (Water proofing compound to be measured and paid for separately).
M&L for Rendering 10mm thick on brick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement all as specified and directed.
M&L for Rendering 5mm thick on brick or concrete surface as in ceiling in cement mortar 1:3 finished even and smooth without using extra cement all as specified and as directed.
M&L for rendering 5mm thick on fair faces on roof surfaces of concrete surfaces in cement mortar 1:4 with WPC complete all as specified & directed. (WPC will be measured and paid separately).
Supply only integral water proofing compound complete all as specified and as directed.
M&L for glazed coloured ceramic tiles in dado/vertical surface size 600mmx300mmx10mm thick set and jointed in neat cement slurry and pointed in coloured cement to match the surface including 10 mm thick rendering as backing coat to receive the tiles on fair faces of brick /concrete surfaces in cement mortar 1:3 and finished even and rough complete all as specified and directed.
M&L for Non skid Ceramic coloured tiles 300x300x7mm thick in floor etc incl 10mm thick screed bed in cement mortar 1:4 for laying floor finishes under floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and as directed.
M&L for pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete , of frame size 105 x 60 mm, including one shop coat of red oxide zinc chrome primer complete all as specified and as directed.
M&L for factory made, 2nd class hard wood 35 mm thick, plain framed, panelled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered partical board with commercial veneering on both sides. The size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F factory made mild steel ventilators box type with upper top hung shutters and bottom fixed type shutters including pintol hinges,steel peg stay and one shop coat of red oxide primer complete all as specified and as directed. Note :- i) The window shall be fabricated as per Drg No CEUZ/TD/1302/2009 Sheet 1/3 to 3/3 ii) MS fillets, glazing, wire gauge shall be measured and paid separately
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing;frame work for water tanks and similar work conforming to Fe 290 Gd E-165 complete all as specified and as directed.
S&F stainless steel wire cloth 0.36mm nominal and average width of apreture 1.40mm and fixed with tinned teaks or wire staple complete all as specified and as directed.
M&L for rolled mild steel work of angle iron as in frames of doors , coolar stand ,Cup Board,stairs & Monkey Guard etc conforming to grade Fe 410-O or Fe-310-O complete all as specified and as directed.
S&F Hard Drawn steel wire fabric cut to length bent to shape required and tying,welding to the angle iron frame etc complete all as specified and directed.( weight n.exc 4kg /sqm )
S&F AC designer composite ceiling board 4 to 6mm thick in 600x600mm panel confirming to IS-14682 TYPE-B category-3 including GI frame, holdfast and suspenders complete all as specified and as directed by Engr-in-charge
Extra over stone walling for hammer dressing with miximum depression on face from straight edge held against the dressed surface not exceeding 20 mm to face stones (Granite or Trap stone) and dressing of face beds and joints, as specified of random rubble walling, uncoursed or brought upto courses complete all as specified and as directed.
M&L for pre painted galvalume aluminium zinc coating GI based corrugated sheets 0.5 mm thick of any colour having tensile strenght of 550/MPA as in roof covering, cladding to wall fixed with self taping screws complete all as specified and as directed.
M & L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
1st Layer:- Grading with cement concrete - M & L for 50 mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate)) for grading in roof all as per Para 11.42.2 of SSR Part –I 2020.
2nd Layer :- Application of Bitumen Primer - Bitumen primer @ 0.40 Ltr /Sqm by the same membrane manufacturer of density at 250C, 0.87 to 0.89 Kg /Litre and viscosity 70-160 cps shall be applied on the prepared surface.
3rd Layer: Laying of 3 mm thick APP Modified five layered membrane reinforced with non-woven polyester matt - Providing and laying 3 mm thick APP (Atactic Polypropylene Polymer) modified prefabricated five layer, weight not less than 3.00 Kg /sqm proofing membrane, black finished reinforced with polyester non woven fabric (wt not less than 150 gms /sqm) laid on primed surface by forced application and membrane shall be laid using butane torch and sealing all joints etc all as per Para 11.44.5 of SSR Part-I.
S&F Aluminium handles, cast type, 150 mm long complete all as specified and as directed.
S&F for 150mm size aluminium barrel tower bolt of extruded section and fixed.all as specified and directed.
S&F Stainless steel curtain rails, 25 mm dia chromium plated with fixing brackets, stops, rollers etccomplete all as specified and as directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm colour PVC sheet reinforced with M.S. Square tube, in opening as per specifiecation and drawings.
S&F factory made solid panel PVC moulded door shutter 30mm thick style consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement forstyle and colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading and jointed together with solvent cement supply & fixing in the frame at site. complete all as specified and as directed.
S & F in repair Wash hand basin, flat back 550x400mm, vitreous china (white) including Pedestal pan and trap including connection to drain brass chromium plated waste fitting, and iron brakets complete all as specified and as directed.
M&L for preparation of wooden surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.
M&L for preparation of steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of primer. all as specified.
M&L for applying two coats of white washing on ceiling including preparation of new/old plastered surfaces complete all as specified.
M&L two coats of oil bound distemper on walls including preparation on old surfaces including applying 1 mm thick layer of wall putty on walls to give uniform surface complete all as specified and directed. Note :- (Before applying of wall care putty, complete removing of Old treatment as directed and approved by Engr-in-charge). Note :This items will be executed upto 6th floor on external surface.
Removing existing piant by scrapping with truecare wall sander : L-01/H-01 (haviing mechanical vaccum mechanism) having RPM not less than 1500, standing pad 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint etc by skilled labour complete all as specified and as directed.
Providing and applying 1m thick waterproof cement based putty @ 1 kg per Sqm of Asian paints of its equivalent over the plastered/old painted wall after scrapping to prepare the surface even and smooth, complete all as specified and as directed. (Step 1 kg putty per minute). Step 2 ( Apply the first coat the prepared mixer with the help fully automatic airless spray machine of putty application of Asian Paints/Birla opus and equivelent spray Machine (Model : EH 230 DI) or equivalent having DC Electric Motor of 3.3KW having flow speed fo max 6 Ltrs per minutes with a maximum pressure 230 bar having maximum tip size 0.041" or by manual. Step 3 (Allow 6-8 hrs time to dry the putty surface. Note :This items will be executed upto 6th floor on external surface.
Sanding of the putty surface with Asian Paints/Birla opus and equivelent truecare wall sander : L-01/H-01 (haviing mechanical vaccum mechanism) having RPM not less than 1500, standing pad 240 Grit having dia of 7"/9" to make the surface free from dust, loose paint etc by skilled labour complete all as specified and as directed. Note :This items will be executed upto 6th floor on external surface.
Providing and applying one coat of acrylic waterbased interior/exterior grade primer @ 0.8 Ltr (undiluted)/10Sqm diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application of Asian Paints/Birla opus and equivelent trucare Graco or equivalent having an electric motor of min 1 HP wiht a flow speed of min 1 Ltr per minute having a pressure of 3300 PSI Allow 6-8 Hrs to dry the surface fro painting of subsequent coats, complete all as specified and as directed.Note :This items will be executed upto 6th floor on external surface.
Providing and applying two coats of smooth acrylic emulsion with rich matt finish having voc less than 50 Grams per Ltr complying leed criteria @ 1 Ltrs (undiluted)/10Sq2 diluted with water in 2:1 ration applied over priming coat with fully automatic airless spray machine of paint application of Asian Paints/Birla opus and equivelent having an electric motor of min 1 HP with a flow speed of min 1 Ltr per minute having a presure of 3300 PSI allow 6-8 hrs to dry the surface in bioth the coats of paint, Complete all as specified and as directed
Note :- (a) (Application of Sr item No 01 to 05 here-in above) The tendered shall Submit a copy of MoU towards triparty agreement between tenderer, Manfacturer of Paints from Asian Paints/Birla opus and their Applicators for material and execution of work from any of the said Manfacturers. Financial Bids of only those bidders shall be admitted whosoever shall be submit a legitimate MOU. Note :This items will be executed upto 6th floor on external surface. (b) Terms of MOU so entered between tenders, Applicators and Manfutctures mentioned above shall also cover the guarntee from manfacturer of Paints for any defect in work executed by their applicators for a period of 5 Years. All other aspects with regard to payments or execution of work.
Note :- (c) (Applicable to Sr Item other than covered under Note 01 to 05 here -in-before). The necessary steel scafflonding upto G+3 Storeyed wherever required to executive the work shall be provided by the contractor with all safety equipments and the cost of providing scaffolding & safety equipments shall be deemed to be included in the quoted rates of the contractor and nothing extra shall be admisible on this account. (d) The work shall be executed in AOR of AGE B/R-I and is being restricted area and head loss etc shall be considered before quonting the rates by the contractor as nothing extra shall be admissible on this account.
S&F Vitreous china Urinal, Half stall type white match with urinal fittings complete all as specified and as directed.
S&F vitreous China wash down water closet pan pedestal pattern, white (excluding fixing bolts, flushing cistern and flush pipe) with P or S trap but including plastic water closet seal, seat cover ,white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminium hinging device including connection to drain and flush pipe complete all as specified and as directed.
S&F in repair water closet white vitreous china ware Orissa pattern of size 580x440mm with integral foot rest ‘P’ or ‘S’ trap 100mm dia front or back inlet incl provision of PCC bedding type B1, 1:2:4 ( 20 mm graded aggregate) and connection pipes ( excluding flushing cistern but including flushing pipe 32 mm dia MS chromium plated) (rate also include for taking off unhygienic of WC).
S&F in repair 10 ltr PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed.
Supply only flush pipe of PVC 32 mm dia for low level cistern complete all as specified and as directed.
S&F MS grating 100mm dia fixed to floor trap complete all as specified and as directed.
M&L 600 mm long brass chromium plated towel rail fancy type complete all as specified and directed.
S&F PVC connection 15mm size with PTMT nuts of lengh 450mm complete all as specified and as directed.
S&F steel peg set colour coated of six as per sample complete all as specified and as directed.
PVC (SWR) pipes 110mm bore single socketed , in any length with rubber ring joints fixed to wall complete all as specified and as directed.
PVC (SWR) pipes 75mm bore single socketed , in any length with rubber ring joints fixed to wall complete all as specified and as directed.
S&F PVC (SWR) bend any radius for 110mm bore pipe complete all as specified and as directed.
S&F PVC (SWR) bend any radius for 110mm bore pipe complete all as specified and as directed.
S&F PVC (SWR)branch piece single (single Y) equal or unequal for 110mm bore pipe complete all as specified and as directed.
S&F PVC (SWR)branch piece single (single Y) equal or unequal for 75mm bore pipe complete all as specified and as directed.
S&F PVC (SWR) junction single (single T) equal or unequal for 100mm bore pipe complete all as specified and as directed.
S&F PVC (SWR) junction single (single T ) equal or unequal for 75mm bore pipe complete all as specified and as directed.
S&F PVC (SWR) reducers for100mm bore pipe complete all as specified and as directed.
S&F PVC (SWR)'P' Trap for110mm bore pipe complete all as specified and as directed.
S&F cast iron floor trap 75 mm, with grating including jointing to waste pipe complete all as specified and as directed.
Taking up or down 15 mm bore steel tubing with connections for cleaning for refixing or removing to store yard complete all as specified and as directed.
Taking up or down 20 mm bore steel tubing with connections for cleaning for refixing or removing to store yard complete all as specified and as directed.
M&L 15mm bore galvanised steel water tubing medium grade (ISI Marked) with all fittings and fixed complete to walls and or laid under floors etc complete all as specified and as directed.
M&L 20mm bore galvanised steel water tubing medium grade (ISI Marked) with all fittings and fixed complete to walls and or laid under floors etc complete all as specified and as directed.
M&L Gun metal globe of gate valve with iron wheel head, screwed both ends of size 20mm complete all as specified and as directed.
M&L Gun metal globe of gate valve with iron wheel head, screwed both ends of size 15mm complete all as specified and as directed.
S&F fancy type chromium plated angle valve cast copper alloy, screwed down, high pressure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions chromium plated of size 15 mm complete all as specified and as directed.
S&F of Bib tap cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe of size 15mm bore chromium plated complete all as specified and as directed.
S&F fancy type chromium plated With long shank and cup (concealed type ) cast copper alloy, screwed down, high pressure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions chromium plated of size 15 mm complete all as specified and as directed.
S&F as in repair chromium plated shower roses 125 mm long with or without swivel joints, any size, including fixing fixing to steel pipe or union complete all as specified and direceted.
S & F in repairs 15 mm dia WHB mixer centre hole chromium plated screwed down high pressure with crutch or butterfly handle screwedboth ends for iron pipes or for unions and fixed complete all as specifie and as directed.
S &F sheet glass shelf assembly/corner consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plate bracket guard and railing 60 cm long in repair complete all as specified and as directed.
S&F rotational moulded polyethylene water storage tanks ( cylindrical vertical with thread closed top) hoisted and fixed in position all as specified in SSR Part-I of capacity 1000 liters including all accessories complete all as specified and as directed.
S&F in repair Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and as directed.
S & F in repairs 15 mm dia wall mixer, chromium plated screwed down high pressure with crutch or butterfly handle screwedboth ends for iron pipes or for unions and fixed complete all as specifie and as directed.
S & F in 4mm dia galvanised steel wire,150x100mm mesh, made up into mattresses or cages, lapped,wired and laid in position,including closing after filling complete all as specified and as directed.
Brick work with sub-class 'B' bricks in one brick thick honey comb walling, built in cement mortar 1:6 complete all as specified and directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
All as per srl item No. 111 above but 5mm dia and over including 10mm dia in stirrups, spaces and binders etc all as specified and as directed.
M&L 200mm bore Reinforced concrete pipes,class NP2,laid and jointed complete with coller all as specified and as directed.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed
M&L for 150mm bore salt glazed stone ware drain pipes laid in trenches and jointed complete all as specified and as directed.
Taking down carefully, copper/ aluminum point wiring (light, fan, socket or power) complete including fitting such as switch, sockets, ceiling rose, pendants socket,fan regulators any type, rectangular board ,light fittings,terminal boxes etc removing materials for taking credit and making good disturbed surfaces of walls floors and ceiling complete all as directed.
Point wiring for one light/ fan/bell point controlled by one switch using 1.5 Sq mm FRLSH copper conductor cables (multistanded) PVC insulated and unseathed in and including PVC concealed conduit as per site requirement (size not less than 20mm dia), medium grade with Modular sunken boxes & PVC/Metal back plate for mounting modular type switches, sockets & regulators etc with cover plate modular type including supplying and laying PVC insulated and stranded unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire connected to earth dolly including cutting of chases in wall / ceiling etc and making good the disturbed surfaces match to existing with cement mortar and putty white/ colour wash complete all as directed .
All as per item no 117 above but cable 2.5 sqmm FRLSH for one 3/5 pin 6 Amp socket outlet point on the same board with other switch.
All as per Srl item No 117 but for 3/5 Pin 16 Amps socket outlet independent board with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 2.5 sq mm earth wire standard and connected to earth dolly.
S&F for modular switch 6 Amps single pole one way 230 V, 50 Hz, AC , with inner / outer cover required module complete all as specified and directed by Engr In charge.
S&F for modular switch 16 Amps single pole one way 230 V, 50 Hz, AC , with inner / outer cover required module complete all as specified and directed by Engr In charge
S&F for modular socket 3/5 Pin 6 Amps flush type 230 V, 50 Hz, AC , with inner / outer cover required module complete all as specified and directed by Engr In charge.
S&F for modular socket combined 2-in-1, 6 Pin 6 & 16 Amps 230 V, 50 Hz, AC , flush type with inner / outer cover required module complete all as specified and directed by Engr In charge.
M &L Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Blockcomplete all as specified and directed by Engr In charge.
S&F Sheet metal enclosure double door type for DBs (when MCB to be used) 4 way 240 volts with suitable rated busbar and neutral link including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
S & F in replacement MCB Single pole and neutral 240 volt any rating from 40/63 amps"C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable .
S & F in replacement MCB single pole 240 volt any rating from 6 to 32 amps "C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable .
S&F Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 6 Sqmm in PVC concealed conduit 25mm dia including PVC insulated copper conductor cable 6 Sq mm as earth lead all as specified. Including taking down old sub main wire complete all as specified and as directed.
S&F LED tube light fitting Garnet 20W Batten LED, Housing made of extruded AL with lumen O/P should not be less than 100 lum/watt making all connection using flexible cable of suitable size from ceiling rose to fitting.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with cable of suitable size complete all as specified and as directed.
Supply and fixing replacement LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp,clamps,suitable bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
Supply and fix electric water heater,storage with steel inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate,NRV, connection piece etc.
Supply and fix exhaust fan, plastic body AC single Phase. 230V of size 250mm sweep with, blades, and frame and louvers.
stage.html
html • 0.05 MB
techsummary_843654.pdf
BOQ Comparative Chart
xlsx
finsummary_843654.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
TENDER123.pdf
Tender Documents • 1.05 MB
BOQ_843654.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .