Shri Jaswant Singh
GE (W) Agra
REPAIR/ MAINT TO MES OFFICE UNDER AOR AGE B/R-II OF GE (WEST) AGRA
2026_MES_779782_1
8012/1189/E8
Open Tender
Civil Works
Item Rate
180 days
GE (W) Agra
Please refer tender document
9 documents required · 9 mandatory
₹500
GE (W) Agra
₹60,000
20 Jul 2026
20 Jul 2026
17 Aug 2026
20 Jul 2026
10 Aug 2026
4 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling/ demolition of polymeric water proofing membrane single layer with and including plaster, PCC, Padding, brick coba etc on roofs complete including removal of material and debris away from the site etc complete all as specified and directed. | 120 | Sqm | - | - |
| 2 | M&L for Remove loose and damaged concrete roof screed in pockets with mechanical cutter. Clean the concrete screed with high pressure water jet to remove dirt and loose particles. Brush apply a bond coat of Pidicrete URP mix in the ratio of 1:1 (URP 1: Cement 1) by volume to make it lump free slurry when applied on in the pre wet surface complete all as specified and directed. | 120 | Sqm | - | - |
| 3 | M&L for Laid to fall roof screed in correct slope and gradient. Mix Dr. Fixit Pidicrete URP 10% by weight of cement in (M20) concrete in ratio of 1:1.5:3 i.e., one bag of 50kg cements: 1.5 times volume of sand: 3 times volume of aggregates: 25L water. Level the repair mortar and finish with trowel. Moist cure should be done for 7days. Air cure screed for 7days, before application of roof top coat coating system etc complete all as specified & directed. | 120 | Sqm | - | - |
| 4 | M&L for Apply one coat of Cipoxy 16D primer in the ratio 1:1 spreading at the rate of 0.200 kg-0.250 kg /sqm in complete dry condition where moisture contain below 7% (should be checked with moisture meter)Allow the primer coat to dry for 6 to 8 hours. Apply 1st coat of Roofseal Classic without dilution spreading at the rate of 0.70/litre/Sq.mt/Coat until all surface is covered. Lay a 45 GSM Fibre glass mesh as a reinforcing material which is incorporated in the coating when the first coat is still in wet condition. Allow the first coat to dry for approximately 4 to 6 hours. Apply the second of chemical with the same application coverage, but in a direction perpendicular to that of the first and second coats. Allow each coat to air cure for a minimum of 4-6 hours after application. Check to see no void surface is left untreated / uncoated.Allow the system to air cure for 7 days minimum etc complete all as specified & directed. | 120 | Sqm | - | - |
| 5 | M&L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 including demolition of old brick work built in CM complete all as specified & directed | 5 | Cum | - | - |
| 6 | Taking down cement or cement lime plaster of any discription on brick or stone walls/ ceilings etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. | - | Sqm | - | - |
| 7 | M&L for 10 to 12 mm smart care ready mix repair plaster is a specially designed ready to use cement-based plaster with high quality polymer additives and well graded sand and fillers wihich can be used for plastering (as per manufacturer instructions) over exterior wall surface complete all as specified and directed | 500 | Sqm | - | - |
| 8 | Material & Labour for preparing newly plastered surfaces of wall, applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm including putty over new surface of wall complete all as specified and directed. | 500 | Sqm | - | - |
| 9 | M&L for 10-12mm thick smart care ready mix repair plaster with high quality polymer additives and well graded sand and fillers which can be used for plastering (as per manufacturer instructions )over interior surface of wall complete all as specified and directed. | 300 | Sqm | - | - |
| 10 | Preparing newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer and two or more coat of wall care putty to obtain smooth finish on wall complete all as specified and directed. | 300 | Sqm | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
BOQ_873418.xls
BOQ • 10.61 MB
Tender.pdf
Tender Documents • 0.80 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].