| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.8 LAccepted-AOC | L1 | Accepted-AOC ok | |
| 2 | L2₹13.4 L+₹1.4 L (12.0%)Rejected-Finance | L2 | Rejected-Finance Not responsive | |
| 3 | L3₹13.5 L+₹1.5 L (12.6%)Rejected-Finance | L3 | Rejected-Finance Not responsive | |
| 4 | L4₹14.2 L+₹2.2 L (18.2%)Rejected-Finance | L4 | Rejected-Finance Not responsive |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
29 Sept 2020, 5:00 pmClosed
Executive Engineer
CCS HAU Hisar
Special repair to 6 type house No 9 situated in New Campus at CCS HAU Hisar
2020_HRY_144562_1
3174-C
Open Tender
Civil Works
Works
120 days
CCS HAU HISAR
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
Executive Engineer C2
₹19,000
3 Nov 2020
16 Sept 2020
3 Oct 2020
16 Sept 2020
29 Sept 2020
16 Sept 2020
Amount
Civil work 1 to 68:- Loading , unloading for sand /earth/ building rubbish. (HSR 4.1)
Disposal/ carriage of material / building rubbish ( metalled road) with a lead of 2 K.M. excluding loading, unloading {HSR 5.2(a)}
Dismantling brick work, tile masonry or tile lining and tile terracing {HSR 8.5(b)+ note} (b) in cement (ground floor)
Dismantling brick work, tile masonry or tile lining and tile terracing {HSR 8.5(b)+ note} (First floor)
Dismantling concrete {HSR 8.6(d)} (d) cement concrete plain 1:2:4 mix (ground floor)
Dismantling concrete {HSR 8.6(d)} (d) cement concrete plain 1:2:4 mix First floor
Dismantling concrete {HSR 8.6(e) + note} (e) reinforced cement concrete with cleaning and straightening and cutting of bars if required
Dismantling concrete {HSR 8.6(e) + note} (e) reinforced cement concrete with cleaning and straightening First floor
Dismantling roofing (HSR 8.8(g)} (g) demolishing mud phaska in tile terracing First floor
Dismantling roofing (HSR 8.8(g)} (g) demolishing mud phaska in tile terracing 2ndfloor
Dismantling cement conglomerate/terrazzo floors 25 mm to 50 mm thick without concrete base. (HSR 8.26) ground floor
Dismantling cement conglomerate/terrazzo floors 25 mm to 50 mm thick without concrete base. (HSR 8.26) First floor
Scraping {HSR 8.32(c)} (c) Cement plaster Ground floor
Scraping {HSR 8.32(c)} (c) Cement plaster First floor
Scraping {HSR 8.32(c)} (c) Cement plaster second floor
Scraping {HSR 8.32(a)} (a) White wash and colour wash
Cement concrete 1:8:16 with brick ballast 40 mm nominal size in foundation and plinth. (HSR 10.26)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size in foundation and plinth (HSR 10.41)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size in first storey upto 4 metres above plinth level (HSR 10.59)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work in shelves excluding steel reinforcement, but including centring and shuttering, laid in position, complete in all respects. (HSR 10.81)
Extra over item Nos. 10.79 to 10.94 , if 1:1.5:3 mix is used, instead of 1:2:4 {HSR 10.95(a)}
11.43 cm thick brick wall laid in cement sand mortar 1:4 in superstructure (HSR 11.48(a)
Terracing consisting of tiles 22.86 cm X 11.43 cm X 3.81 cm laid over 87.50 mm mud filling on a layer of 25 mm mud plaster and an other layer of mud mortar for laying the tiles, including two coats of bitumen laid hot at 1.65 kg per sqm on top of R.C.C slab including grouting with cement sand mortar 1:3 and top surface to be left clean etc. (excluding cost of brick tiles) (based on 13.13) Note:- Old tiles will be supplied by the department free of cost.
Terracing consisting of tiles 22.86 cm X 11.43 cm X 3.81 cm laid over 87.50 mm mud filling on a layer of 25 mm mud plaster and an other layer of mud mortar for laying the tiles, including two coats of bitumen laid hot at 1.65 kg per sqm on top of R.C.C slab including grouting with cement sand mortar 1:3 and top surface to be left clean etc. (HSR 13.13) ground floor
Terracing consisting of tiles 22.86 cm X 11.43 cm X 3.81 cm laid over 87.50 mm mud filling on a layer of 25 mm mud plaster and an other layer of mud mortar for laying the tiles, including two coats of bitumen laid hot at 1.65 kg per sqm on top of R.C.C slab including grouting with cement sand mortar 1:3 and top surface to be left clean etc. (HSR 13.13) First floor
Top khurra 0.6 m X 0.6 m for rain water pipe in 25 mm thick cement concrete 1:2:4 over 50 mm thick cement concrete 1:8:16 (HSR 13.50)
Bottom khurra on ground 1.2 m X 0.6 m consisting of brick-on-edge laid in cement mortar 1:3 over 75 mm cement concrete 1:8:16 including 12 mm thick cement plaster 1:3 (HSR 13.57)
Cement concrete 1:2:4 gola 10 cm X 10 cm quadrant along junction of roof with parapet wall finished smooth, where specially specified (HSR 13.64)
Providing and fixing PVC rain water pipe pressure of ISI mark in cement mortar during masonry work {HSR 13.89(a)} (a) 100 mm dia PVC pipe 6 kg. pressure
Providing and fixing PVC bend ISI mark {HSR 13.90(a)} (a) 100 mm dia PVC bend
Floating coat of 1.50 mm thick neat cement laid in one operation to the topping (HSR 14.3)
Conglomerate floor 50 mm thick cement concrete topping 1:2:4 (HSR 14.10)
18 mm thick grey polished skirting or dado consisting of bottom layer of 15 mm thick cement sand plaster 1:3 and finished with 3 mm thick topping of neat cement rubbed and polished including rounding off junction with floors (HSR 14.18)
Providing and fixing vitrified tiles of size 600 x 600 mm of approved make in flooring laid in any patterns as specified over base of 20 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade to tiles (HSR 14.89) Notes: i. Tile shall be premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSONS, RAK & SIMPOLO ii. Tiles shall be fixed by using PVC spacers of required size and the space between tiles shall be filled up with cement based grout of approved make & colour. Nothing extra shall be paid for this.
Providing and fixing vitrified tiles of size 600 x 600 mm of approved make in skirting / dado laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade to tiles (HSR 14.90) Notes: i. Tile shall be premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSONS, RAK & SIMPOLO ii. Tiles shall be fixed by using PVC spacers of required size and the space between tiles shall be filled up with cement based grout of approved make & colour. Nothing extra shall be paid for this.
Providing and fixing ceramic tiles/ anti skid tiles of size 400 mm x 400 mm or above size of approved make in flooring, laid in any pattern as specified over base of 20 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of tiles Notes: i. Tile shall be premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSONS, RAK & SIMPOLO ii. Tiles shall be fixed by using PVC spacers of required size and the space between tiles shall be filled up with cement based grout of approved make & colour. Nothing extra shall be paid for this. (HSR 14.91)
Providing and fixing 1st quality ceramic glazed wall tiles confirming to I.S. 15622 (thickness to be specified by the manufacturer) of approved make in all colour, shades except burgundy, bottle green, black of any size of approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement coarse sand mortar 1:3 and jointed with grey cement slurry, including pointing in white cement mixed with pigment of matching shades complete (HSR 14.92 (b) (b) size of ceramic glazed tiles 300 mm x 450 mm
Providing edge moulding to 17-20 m thick granite stone counters, vanities etc. including machine polished to edge to give high finish etc. complete as per design apprvoed by Engineer-In-Charge (Moulding) (HSR 14.98 (i) (i) Single moulding
12 mm thick cement plaster 1:4 on walls (HSR 15.5) ground floor
12 mm thick cement plaster 1:4 on walls (HSR 15.5) First floor
15 mm thick cement plaster 1:4 on the rough side of single or half brick wall. (HSR 15.10) ground floor
15 mm thick cement plaster 1:4 on the rough side of single or half brick wall. (HSR 15.10) First floor
15 mm thick cement plaster 1:4 on the rough side of single or half brick wall. (HSR 15.10) second floor
20 mm thick cement plaster 1:4 in 2 coats work. (HSR 15.15)
10 mm thick cement plaster 1:4 on underside of ceiling (HSR 15.52) ground floor
10 mm thick cement plaster 1:4 on underside of ceiling (HSR 15.52) First floor
Cement pointing 1:2 flush on brick and tile walls (HSR 15.62)
Cement pointing 1:2 flush on flat brick flooring (HSR 15.71) ground floor
Cement pointing 1:2 flush on flat brick flooring (HSR 15.71) First floor
Painting one coat with synthetic enamel paint in all shades on old wood work or metallic or plastered or concrete surfaces to give an even shade including rubbing down old paint (HSR 16.7)
Applying priming coat with cement primer in all shades on newly plastered or concrete exterior surfaces (HSR 16.25)
White washing two coats (HSR 16.47)
Distempering with washable oil bound distemper (of approved manufacture) two coasts excluding priming coat on new work (HSR 16.57)
Finishing walls with exterior decorative cement based paints such as snowcem , Robbiacem etc. on new work, two coats to give an even shade (HSR 16.61)
Providing and applying two coats of white cement based putty over plastered surface and grinding the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc., complete (J.K/ Birla make). (HSR 16.81)
Wrought iron and mild steel (using angles, flats square bars. tees and channels) ladders, grills, gratting frames, window guards, iron door openable or fixed stair case or parapet or any other type of railing , gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position {HSR 18.12}
Parapet railing of 40 mm internal dia G.I. pipe class 'B' as per I.S. 1239 as hand rail using flats and square bars as supporting members and base plate welded as per design specified including cutting, welding rods and fixed in position complete in all respect. ( HSR 18.13 (b)
Steel reinforcement TMT bars FE-500 EQR/FE-500 D grade or more for RCC work, where no included in the complete rate of RCC incluidng straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position, complete in all respect for all heights/depths/storeys/basements etc. Note: Reinforcement shall be measured in length including hooks, if any, separtely for different diameters as actually used in work excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (HSR 18.22)
Laying brick on end edging length wise 22.86 cm deep and 6.83 cm wide including excavation of earth and refilling the excavated soil and compacting along brick edging complete in all respect with other than brick soling. {HSR (24.6(b)}
Providing and applying two coats of Dr. Fixit Pidicrete URP – SBR Latex (Pidilite make) solution made of URP + cement in the proportion of 1:1.5 (as recommended by the manufacturer) on deteriorated concrete surfaces of slab and columns, complete in all respects as directed by the Engineer-in-Charge. (NS)
Rubbing and polishing the existing terrazo flooring with carbporandum stones ( two rubbing- with fine and extra fine grade stones), jointed with cement slurry including cost of powder, wax polish, oxlanic acid, etc. complete in all respect as directed by the Engineer- in – charge / Haryana PWD Specifications. (NS)
Providing and fixing marble strips of size 14 mm to 17 mm thick and 40 mm wide in cement concrete/ terrazzo flooring fixed in position, complete in all respects as per drawing and design or as directed by Engineer-in-Charge. (NS)
Tacking (making rough) the exposed reinforced cement concrete surface for cement plaster (horizontal and vertical surface) including removing of loose concrete, disposing off the malba and cleaning the surface etc., complete in all respect as directed by Engineer-in-Charge. (NS)
Scraping of brick tiles of size 22.86 cm x 11.43 cm x 3.81 cm in cement mortar, complete in all respect as directed by Engineer-in-Charge. (NS)
Providing and fixing 15 mm to 18 mm thick Z-Black granite stone (polished) on worktop laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade including rubbing and polishing, complete. (NS)
Providing and fixing C.I. grating over 100 mm dia rain water pipe, fixed in position, complete in all respects. (NS)
Collection of 1st class bricks, at the site of work including carriage , loading, unloading and stacking, etc., confirming to Haryana PWD Specification No.3.5 complete in all respects (N.S.)
Providing and applying two coats of Dr. Fixit Fastflex (Pidilite make) solution made of powder and polymer in the proportions as recommended by the manufacturer (7 kg powder + 5 kg polymer) on sound and clean surface of walls/roof (horizontal /vetical sarfaces) including prepration of surface & repair of surface using a suitable Dr. Fixit repair material, complete in all respects as directed by the Engineer-in-Charge and manufacturars specifications. (NS)
Public helath work 69 to 152:- Loading , unloading for sand /earth (HSR 4.1-a)
Disposal of surplus excavated soil with a lead of 3 K.M. excluding loading, unloading (HSR 5.2-b)
Dismantling brick work, tile masonry or tile lining and tile terracing (HSR 8.5-b) (b) in cement
Dismantling concrete (HSR 8.6-e) (e) reinforced cement concrete with cleaning and straightening and cutting of bars if required
Removing door and windows(wood and steel) with chowkats by making recesses in walls when the wall is not to be dismantlled :- (HSR 8.18 a & b) (a) doors
Removing door and windows(wood and steel) with chowkats by making recesses in walls when the wall is not to be dismantlled :- (HSR 8.18 a & b) (b) Windows
Dismantling cement conglomerate/terrazzo floors 25 mm to 50 mm thick including concrete base (HSR 8.25)
Scraping white wash and colour wash (HSR 8.32-a)
Scraping of cement plaster (HSR 8.32-c)
Dismantling white or coloured glazed tiles ( to be carefully removed) (HSR 8.38)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size in foundation and plinth (HSR 10.41)
Cement concrete 1:2:4 with stone aggregate 20mm nominal size for reinforced concrete work in slabs with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement , but including centring and shuttering, laid in position , complete in all respects. (HSR 10.82)
Extra over item Nos. 10.79 to 10.94 , if 1:1.5:3 mix is used, instead of 1:2:4 (HSR 10.95-a)
First class brick work laid in cement sand mortar 1:4 in foundation and plinth (HSR 11.4)
Base course of floors consisting of 100 mm thick cement concrete 1:8:16 and 100 mm sand or stone filling(HSR 14.1)
Screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping (HSR 14.4)
Providing and fixing ceramic tiles/ anti skid tiles of size 400 mm x 400 mm or above size of approved make in flooring, laid in any pattern as specified over base of 20 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of tiles (HSR 14.91) Note : tile shall be of premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSONS & RAK
Providing and fixing 1st quality ceramic glazed wall tiles confirming to I.S. 15622 (thickness to be specified by the manufacturer) of approved make in all colour, shades except burgundy, bottle green, black of any size of approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement coarse sand mortar 1:3 and jointed with grey cement slurry, including pointing in white cement mixed with pigment of matching shades complete (HSR 14.92-b) b) size of ceramic glazed tiles 300 mm x 450 mm
12 mm thick cement plaster 1:4 on walls (HSR 15.5)
Applying priming coat with cement primer in all shades on newly plastered or concrete exterior surfaces(HSR 16.25)
Providing and applying two coats of white cement based putty over plastered surface and grinding the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc., complete (J.K/ Birla make). (HSR 16.81)
Painting two coats with synthetic enamel paint in all shades on old wood work or metallic or plastered or concrete surfaces to give an even shade including rubbing down old paint (HSR 16.5)
Distempering with washable oil bound distemper (of approved manufacture) two coasts excluding priming coat on new work (HSR 16.57)
Steel work, fixed independently without connecting plates, including cutting, hoisting and fixing in position in :- (HSR 18.1-a) (a) R.S. joists
Steel reinforcement TMT bars FE-500 EQR/FE-500 D grade or more for RCC work, where no included in the complete rate of RCC incluidng straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position, complete in all respect for all heights/depths/storeys/basements etc. Note: Reinforcement shall be measured in length including hooks, if any, separtely for different diameters as actually used in work excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement (HSR 18.22)
Labour for laying, jointing, fixing and testing G.I./P.V.C./W.I. pipe lines and specials tees, bends, sockets elbows etc. inside building and testing etc. complete including cutting threading. (HSR 28.18 (b) INCLUDING COST OF SPECIALS (i) 15 mm internal diameter of pipe line
Labour for laying, jointing, fixing and testing G.I./P.V.C./W.I. pipe lines and specials tees, bends, sockets elbows etc. inside building and testing etc. complete including cutting threading. (HSR 28.18 (b) INCLUDING COST OF SPECIALS (ii) 20 mm internal diameter of pipe line
Labour for laying, jointing, fixing and testing G.I./P.V.C./W.I. pipe lines and specials tees, bends, sockets elbows etc. inside building and testing etc. complete including cutting threading. (HSR 28.18 (b) INCLUDING COST OF SPECIALS (iii) 25 mm internal diameter of pipe line
Extra for fixing and jointing union couplings in G.I and W.I pipe lines. (HSR 28.21-a) (a) 15 mm internal diameter
Extra for fixing and jointing union couplings in G.I and W.I pipe lines. (HSR 28.21-b) (b) 20 mm internal diameter
Extra for fixing and jointing union couplings in G.I and W.I pipe lines. (HSR 28.21-c) (c) 25 mm internal diameter
Fixing and jointing gun metal peet valves (heavy pattern) with hand wheels, on G.I pipelines laid in the ground or inside buildings including cartage from divisional stores or nearest railway station to site of works. (HSR 28.29-a) (a) 15 mm internal diameter
Fixing and jointing gun metal peet valves (heavy pattern) with hand wheels, on G.I pipelines laid in the ground or inside buildings including cartage from divisional stores or nearest railway station to site of works. (HSR 28.29-b) (b) 20 mm internal diameter
Fixing and jointing gun metal peet valves (heavy pattern) with hand wheels, on G.I pipelines laid in the ground or inside buildings including cartage from divisional stores or nearest railway station to site of works. (HSR 28.29-c) (c) 25 mm internal diameter
Constructing brick masonry inspection chambers sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 percent lime mortar2:3 in foundation cement concrete 1:2:4 benching 12 mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/C.C. topping. 50 mm thick with 455 mm x 455 mm/ 455 mm x 610 mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I specification painted with 3 coats of black bitumastic superior paint complete as per standard design. (HSR 29.84-b) (b) size 450 mm x 600 mm inside (with 455 mm x 610 mm cover and frame single seal pattern I weighing 38 kg with C.C. topping)
Providing and fixing in position best Indian make (to the approval of the Engineer-in-charge). Indian type Orissa or orya water closet suite for sinking into floor, with raised foot treads complete with 100 mm H.C.I ‘P’ trap with or without vent as required and all other necessary fittings as fully described in item no. 30.1 above (excluding cost of C.I. flushing cisterns) (Based on HSR 30.2) (a) 580 mm (i) White
Providing and fixing in position best Indian make European type water closet suite with concealed ‘P’ of ‘S’ trap with or without vent (as approved by the Engineer-in-Charge) and all other necessary fittings as fully described in item No. 30.3 above (excluding cost of C.I. high level cistern) (Based on HSR 30.6) (i) White
Extra over item no. 30.3 to 30.6 for providing and fixing best Indian make plastic hygenic seat with lid complete instead of hollow black or white plastic seat and lid. (HSR 30.13-a) (i) White plastic seat ( Solid)
Providing and fixing in position best Indian make (ordinary) lavatory suites consisting of Lavatory in vitreous china ware size as given below (to the approval of the Engineer-in-charge) including china plug for tap hole where necessary, R.S or C.I brackets for building into wall including painting; 32 mm C.P. brass waste with C.P brass chain and rubber plug; 15 mm C.P brass screw down pillar tap with jamnuts or couplings best design ( as approved by the Engineer-in-charge) all fittings best Indian make and; to the approval of the Engineer-in-charge all brass work chromium plated and complete in all respects including cutting and making good the walls and floors and painting of fittings etc. (HSR 30.41-iv) White (iv) size 550 mm x400 mm with one no tap
Providing and fixing in position 32 mm dia G.I waste pipe embedded in wall or lead waste pipe (weighing 3.47 kg per meter and 2.8 mm thick) up to floor level including cost of wipped solder joint etc., complete (as required by the Engineer-in-charge) (HSR 30.48)
Providing and fixing in position best Indian make chromium plated brass bottle trap 32 mm diameter (HSR 30.50)
Providing and fixing in position best Indian make shower with 15 or 20 I/d out let. (HSR 30.66-c) (c) C.P. brass with revolving joint
Providing and fixing in position best Indian make paper holders fixed into wall with C.P brass screws complete in all respects including cutting and making good the walls etc. (HSR 30.67-a) (a) C.P. brass
Providing and fixing in position best Indian make towel rails fixed in with rawlslugs embedded in walls with C.P brass screws. Complete in all respects including cutting and making good the walls etc.(HSR 30.68(b)(ii) (b) 20MM DIA. C.P BRASS ADJUSTABLE (ii) 600mm long
Providing and fixing in position best Indian make soap dish fixed into wall with C.P brass screws and complete in all respects including cutting and making good the walls etc. (HSR 30.70 (a) (ii) (a) C.P. BRASS (ii) soap dish small
Providing and fixing in position best Indian make bevelled edge 5.5 mm thick mirror mounted on asbestos sheet ground fixed in position by means of 4 nos. chromium plated brass screws and washers over rubber washers and rawl plug embedded in the wall of chromium plated brass clamps with C.P brass screws ( as required by the Engineer-in-charge) complete including cutting and making good the walls etc. (HSR 30.71(a)(i) (a) Indian Make (i) 600mmx450mm
Providing and fixing in position 15 mm i/d C.P brass bib cocks of best quality ( as required by the Engineer-in-charge) (HSR 30.75 a&c) (a) Bib cock long body
(c) Bib cock
Providing and fixing in position C.P brass stop cock (as approved by the Engineer-in-charge) (HSR 30.76a-ii) (a) 15 MM STOP COCK (ii) concealed stop cock with flange
Providing and fixing in position best Indian make C.P brass inlet connection 15mm with 375mm pipe and C.P brass nuts. (HSR 30.83)
Providing and fixing in position H.C.I soil waste vent or antisyphonage pipes to I.S.I specifications of E.L.C manufacture or of any other reputed firm including cutting and wastage etc. and cutting holes in walls, roofs or floors etc. and making good to its original condition but excluding cost of lead jointing. (HSR 30.84 (a) & (b) (a) 100 mm internal diameter
(b) 75 mm internal diameter
Providing lead caulked joints to H.C.I pipes and specials conforming to I.S.I specification of E.L.C manufacture or any other reputed firm including cost of lead yarn, fuel and tools etc. (HSR 30.87-a&b) (a) 100 mm internal diameter
(b) 75 mm internal diameter
Providing and fixing in position M.S. or heavy flat iron clamps made out of M.S flat not less than 5mm of the approved design for fixing C.I soil waste vent or anti pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting (HSR 30.88-a&b) (a) for 100mm internal diameter pipes
(b) for 75mm internal diameter pipes
Providing and fixing H.C.I. floor traps I.S.I. marked of the self cleaning design with C.P. brass hinged grating with frame with or without vent arm and including cement concrete 1:2:4 under the around the floor trap where required upto floor level complete in all respects including cutting and making good the walls and floors, etc., minimum depth of water should be 150 mm with a minimum seal of 50 mm (HSR 30.89-b) (b) With 75 mm internal dia outlet
Providing and fixing in position H.C.I specials for soil, waste, vent or anti-syphonage pipes to I.S.I marked including cutting and wastage etc/., and making good to its orFiginal condition but excluding cost of lead jointing. (HSR 30.91) (a) For 100 Mm I/D Pipes (i) heal rest bend
(iv) single junction with door 100mmx100mm x 100mm
(xiv) bend plain
(xx) P-trap
(xxii) collars
For 75 Mm I/D Pipes (iv) single junction with door 75mmx75mmx75mm
(xiv) Plain bend
(xvii) Cowls
(xviii) Collars
Providing and fixing lead inlet connection with brass union for flushing and warning pipes complete in all respects. (HSR30.93-c) (c) 15 mm alkathene pipe inlet connection
Cutting chase in brick walls in cement or in floor for embedding G.I. or H.C.I. pipe lines and making good the same to its original condition (HSR 30.95-a) (a) (a) size 75 mm X 75 mm
Providing and fixing in position automatic brass ball valves in tanks (HSR30.110-b-ii) (b) With Plastic Ball (ii) 20 mm internal diameter
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with H.C.I. grating 150 mm X 150 mm cast iron cover weighing approximately 7.26 kg. and frame clear opening 300 mm X 300 mm and outside size 330 mm X 330 mm and chamber including cost of all brick work in cement mortar 1:5 cement concrete 1:8:16 in foundations, and cement concrete 1:2:4 in coping around C.I. cover and frame et. With three coats of black bitumastic superior paint of approved manufacture on all C.I. work as per standard design, minimum depth of water should be 150 mm with a minimum seal 50 mm (HSR 30.114-b) (b) 100 mm internal diameter H.C.I. gully trap
Providing and fixing HDPE WATER STORGE TANKS of sintex, diplas O.K. Supreme make with covers/ lids marked with IS: 12701 on roof top of buildings including cost of hoisting and placing in position, making connections with inlet and outlet pipes, providing overflow & scour provisions with suitable plug on scour pipe including cost of nipples, washers, flanges for connections in tanks complete in all respects to the satisfaction of Engineer-in- Charge. (HSR 30.119) (a) 500 ltr,. capacity
Supply of G.I. pipe ‘B’ class ISI marked of ‘Ravindra’/ ‘Jindal’ ‘Parkash ( Surya)’/BST make (NS) (a) 15 mm internal dia
(b) 20 mm internal dia
(c) 25 mm internal dia
Supply of G.I. Union couplings of Unik / Unco make (NS) (a) 15 mm internal dia
(b) 20 mm internal dia
(c) 25 mm internal dia
Supply of G.M. Peet valve (heavy type) of DRP/Leader/Bajaj make ISI marked. (NS) (a) 15 mm internal dia
(b) 20 mm internal dia
(c) 25 mm internal dia
Providing and fixing in position PVC flushing cistern 8.0 ltrs. capacity of Hindware/ Cera make ISI marked, white, alongwith fittings complete in all respect. (NS)
Supply and fixing in position stainless steel sink made of 1 mm thick Salem stainless steel sheet with complete fittings of Jayna/ Bluestar make as per AISI 304/18/8 including cutting and making good the walls and floors and painting of fittings etc. , complete (NS) Overall size = 610 mm x 510 mm x 200 mm Bowl size + 535 mm x 432 mm x 200 mm
Providing and fixing in position PVC flexible waste pipe 32mm dia size of best quality alongwith coupler etc., complete in all respect (NS).
Providing and fixing CP brass jet alongwith flexible pipe and patti etc.of best quality, complete in all respect for EWC (without cost of CP brass concealed stop cock) (NS)
Electrical work 153 to 201:- MOULDED CASE CIRCUIT BREAKERS: (HSR 31.12(c) Supply and erection of moulded case circuit breaker on wall or on existing pedestal including bonding to earth and necessary connections:- (a)15Amp to 60Amp 415V 25KA 3 Phase
MINITURE CIRCUIT BREAKER AND ISOLATOR: (HSR 31.17) Supply and erection of MCBs/isolator 240/415 V in existing distribution board including making necessary connection:- (a) Miniature Circuit Breakers of 9 K.A. Breaking canpacity. (i) 6 to 32 amp. MBC SP
(ii) 32Amp TPN MCB
Supply and Erection of fittings & access :- (HSR 31.18) (vii) call bell 220 to 230 v AC Bakelite with double coil
(xi)Bakelite angle / straight button holder large size.
(xii) 5 Amp switch on existing sheet
(xiii) 5 Amp socket on existing sheet
(xiv)15 Amp switch on existing sheet
(xv)15 Amp socket on existing sheet
(xviii) Bakelite sheet including fixing with brass screws and washer a) 5mm Thick
Pipe Laying :- (HSR31.21) S/E of pipe for wiring purpose i/c bends inspection boxes etc. Where necessary and painting as required (xxi)Heavy gauge welded conduit pipe 20mm dia 1.60mm thickness on flushed
(xxii) Heavy gauge welded conduit pipe 25mm dia 1.60mm thickness on flushed
Earthing :- (HSR 31.22) (i) Earthing with G.I earth pipe 4.5 mm long and 40 mm dia with masonry enclosures on the top etc as required.
(ii) Extra for Salt & Charcoal for G.I Pipe Earthing with top enclosure complete
(xii) Pdg. and laying earth connections from earth electrode with 4.00 mm dia G.I wire in 15 mm dia G.I. pipe from earth electrode as required.
(xiii) Pdg. and laying earth connections from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode as required.
Laying of underground cable 1 mtr below ground level covered with sand and bricks including excavation and refilling of trenches:- (HSR 31.27) (ii) 10 Sqmm to 16 Sqmm 2 to 4 core
Wiring in 1.5 sqmm PVC insulated copper conductor cable in 1.6 mm thick conduit pipe (HSR 31.36) (ii) Light Point. (a) Short Point
(b) Medium Point
(c) Long Point
(vii) 3 Pins 5 Amp plug point including earthing the 3rd pin etc. (a)Short Point
(b)Medium Point
(c) Long Point
(viii)3 Pin 15 Amp plug point with 4 sqmm PVC insulated copper conductor cable including earthing (b) Medium Point
(c) Long point
Wiring in 1.5 sqmm PVC insulated copper conductor cable in existing conduit pipe and MS boxes covered with 5mm thick bakelite sheet including cost of switches wall socket ceiling rose etc. (HSR 31.38) (i) Fan Point. (b) Medium point
(c) Long Point
(ii) Light Point (a) Short Point
(b) Medium Point
(c) Long Point
(iii) Twin control light point with 2 way 5amp single pole switch (a)Short Point
(b)Medium Point
(c)Long Point
(vi) Call Bell point including M.S Box of size 180x100 mm x60 mm deep c) Long Point
3 Pins 5 Amp plug point including earthing the 3rd pin etc. (a)Short Point
(c)Long Point
(viii) 3 Pin 15 Amp plug point with 4 sqmm PVC insulated copper conductor cable including earthing (a) Short Point
(c)Long Point
S/E of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe.HSR-31.40 (i)Cable Size 1.5 sqmm (3/0.81)
(iii)Cable Size 4 sqmm (7/0.85)
(iv)Cable Size 6 sqmm (7/1.05)
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBs and ELCBs etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect upto to the entire satisfaction of the Engineer-in-charge of the work.HSR-31.41 (v)4-Way, TP&N (Horizontal)( 8+12 )
S/E of PVC conduit pipe ISI marked ( Medium ) recessed in wall / ceiling etc. including cost of PVC bends , inspection box and all other material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of work HSR-31.44 (b) 25mm dia
S/E of MS box made of 16 gauge MS sheet recessed in wall with arrangement of fixing brass screws , 2 nos check nuts and 1 no. PVC bush of required size including all labour and material required to complete the job in all respect up to the entirer satisfaction of engineer in charge of work .HSR-31.49 (i) With 2 coats of primer.
S/E of socket size rotary step type electronic regulator for AC ceiling fan Anchor make operated on 120/280 VAC supply complete including cutting of existing Bakelite Sheet and amking necessary connectio etc. Upto the entire satisfaction of the EIC.HSR-31.55
S/E of PVC pipe ISI markes medium recessed in wall / ceiling etc including cost of PVC bends , inspection boxes , iron hooks and cement concrete etc complete in all respect upto the entire satisfaction of EIC of work.HSR-31.58 (b) PVC pipe of 40mm dia
Supply, installation testing and commissioning of wall/free standing floor mounting dust & vermin proof compartmentalized cubical panel made out of 2mm thick CRCA sheet, required hardware 3mm thick Bakelite sheet provided all along the bus bar and cable alley separating switches compartment and supporting suitable channel duly painted by 2 coat of Zinc/Red oxide primer followed by 2 coats of powder coating in grey or required shade after rinsing. The panel having PU/Neoprene rubber gasket of not less than 3mm thickness separate detachable gland plate MS base channel hinged door with inter locking arrangement for equipment/switch wear. Transparent acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar Bakelite sheet 3mm thick for separately cable alley to BBC from switch chamber extended solid copper bars upto cable alleys shall provided for outgoing connection which shall be paid as extra items. Side walls and cable alley compartments shall be having bolted type doors with detachable extension type structure. The panel will be complete with control wiring (copper) and fuse protection (Only outer area on all sides shall be measured).HSR-31.63
Supplying and fixing of copper bus bar duly tinned by means of SMC/DMC type insulator high tensile nuts and bolts spring washers fixing to same in existing panel including bending, cutting in required shape and size and insulation with colour coding heat shrinkable PVC insulation complete in all respect.HSR-31.64
Street Light Erection of 7 mtr octagonal pole with single arm bracket with LED light with connections i/c cost of RCC 1:1.5:3 for foundation size 0.7*0.7*1.8M with min. 8 nos. 12mm dia longitudinal MS reinforcement rods with rings of 8mm dia not more than 200mm CC for fixing the pole i/c the cost of labour and material required to complete the job in all respect upto entire satisfaction of EIC ( excluding Pole & foundation Bolts , bracket , light etc.) NS
MAHARANA ENTERPRISES
Suraj Bhan Contractor
nagpal and company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .