Loading…
Loading…
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
10 Apr 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
TENDER ELG
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less where V= Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.(In this connection scanned copy of Annexure VIB duly filled up must be attached with offer).
The tenderer must have successfully completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender .Other terms and conditions shall follow of GCC, April 2022. Definition of Similar nature of work has given below (1.1)
Defination of Similar Work :- As per CEE's letter No. EL/112/0, dated 16.09.2025 : Name / Description of Work - Item Sl. 2.(ii) under "LT Electrical Works" : Wiring or Rewiring of Staff Quarters/Service Buildings/Station Buildings/ Covered Sheds/PF Sheds or lighting arrangements for street/ yard/ circulating area/Subway/ROB/Tunnels/ lights by erecting Rail/ Tubular poles with fittings and associated electrical works such as laying of cables, Earthing arrangements etc. Definition of Similar Nature of Work -Execution of any HT or LT Electrical work.
13 conditions · 4 needing a document upload
Scanned copy of valid GST (Goods & Service Tax)Registration Certificate.
The following documents should be attached with the tender ( Annexure-V (A) certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. & Scanned copy POA/Partnership deed is to be uploaded Duly filled up by the bidder
Partnership deeds, power of Attorney etc. (if any) : The tender shall clearly specify whether the tender is submitted on his own or on behalf of a partnership concern. If the tender is submitted on behalf of partnership concern he should submit the certified copy of the partnership deed along with the tender authorisation to sign the documents on behalf of the partnership firm. If these documents are not enclosed along with the tender document, the tender will be treated as hearing lease submitted by the individual signing the tender documents. The Railway will not consider any power of Attorney granted by the tender or any changes in the composition of the firm made subsequent to the execution of the contract. It may however recognize such power of Attorney and change after obtaining proper legal advice, the cost of which will be chargeable to the contract.(Scanned copy POA/Partnership deed is to be uploaded Duly filled up by the bidder. As per clause no. 14(e) of GCC'22, the following documents to be uploaded in terms of Company registered under Companies Act2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) above.
Scanned copy of valid Trade license or Propitorship Certificate.
List of the Works completed in the last three financial years giving description of work. Organization for whom executed, approximate value of contract at the time of award, date of award and date of scheduled completion of work. Date of actual start, actual completion and date of payment and final value of contract should also be given. (Supportive documents/ certificates from the organization with whom worked/are working should be enclosed) (Please attach scanned copy of Annexure-I duly filled up).
List of works in hand indicating Supportive documents/certificates from the organization with whom worked/are working should be enclosed) description of work, contract value, approximate value of balance work yet to be done and date of award. (Supportive documents/certificates form the organization with whom worked/are working should be enclosed).(Please attach scanned copy of Annexure-IV duly filled up)
Railway Officers Associated with tenderer:RAILWAY OFFICERS ASSOCIATED WITH TENDERER 1. ExRailway Officer as tenderer: Should tenderer be a retired Gazetted Officer working before his retirement on any of the Railways owned and administered by the President of India, or should the tenderer being partnership firm have as one of its partners a retired Gazetted Officer as aforesaid, or should the tenderer being an incorporated company have any such retired Officer as one of its Directors, or should the tenderer have in his employment any retired Gazetted Officer as aforesaid, full information of such person shall be submitted along with his tender in the format given in annexure-VI to this chapter of this tender document. (Authority: ACS No.3 to GCC July,2014vide Boards letter No.2014/CEI/CT/O/9/RET dt.22.01.2015)(please attach scanned copy of Annexure-VI duly filled up by the firm).
Option for receiving payment through Letter of Credit . (Please attach scannedcopy of ANNEXURE 1 LC & ANNEXURE 2 LC duly filled up by the firm if optedfor)
The following documents should be attached with the tender: (i)Scanned copy of Pan Card. (ii)Scanned Copy of EFTMANDATE FORM Duly filled up by the bidder(iii)Tender Document (duly digitally signed by the bidder)
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Submission of Documents in support of Eligibility Criteria : All documents in support of fulfillment of eligibility criteria with respect to completion of 'Similar Nature of work for technical Eligibility criteria 'and 'Total Contract value for Financial Eligibility Criteria' should be uploaded online in the website with scanned copy at the time of tender bidding with the details. No post - tender communication , in any form will be made or entertained , after opening of tenders in this regard .Railways may however call for the originals of the credentials for verification or any clarifications/Confirmations on the contents of the documents submitted .Eligibility of tenderers shall be decided solely on the basis of the documents submitted alongwith the tender offers and any subsequent document whatsoever submitted in this connection would not be given any cognizance on any account.
The Contractor/(firm) must go through the entire tender document along with all attachment for any kind of guidance regarding execution of the job & payment there after. In case any thing is left out or not clear then they should consult the General Condition of Contract & standard Specification as attached (uploaded ).The bidders are also advised to preserve a copy of entire tender document/ (Set) for their convenience.
Electrical (General) work in connection with "Howrah - Modernization of Signal Workshop".
EL-HWH-25-21-3600~ER
EL-HWH-25-21-3600
Open
Works - General
180 Days
Howrah, West Bengal
₹0
₹2.2 L
10 Apr 2026
20 Mar 2026
27 Mar 2026
131 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,37,51,829 | ||
| — | — | — | 1,60,600 | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 550.00 | — | — | |
| — | — | — | 16,300 | ||
| Wiring of 6A / 3 pin Plug board consisting with one plug socket and one 6A switch by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 100.00 | — | — | |
| — | — | — | 19,250 | ||
| Wiring of 6/16A 3 pin Plug board consisting with one 16/6A 3 pin plug socket and one 16A switch by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 50.00 | — | — | |
| — | — | — | 17,040 | ||
| Wiring of Multi Plug board consisting with three nos. 6A / 3 pin plug socket, three nos. 6A switch, one no. 6/16A 3 pin plug socket, one no. 16A switch, one no. 10A fuse kit-kat / MCB and one indicator ( Red ) by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4 sq. mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 30.00 | — | — | |
| — | — | — | 34,000 | ||
| Wiring of Submain by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 500.00 | — | — | |
| — | — | — | 23,200 | ||
| Wiring of Mainline by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 10 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 100.00 | — | — | |
| — | — | — | 44,530 | ||
| Extra cost for conceal wiring in respect to PVC conduit / casing for light, fan, plug, power plug, multi-plug point etc. including make good of wall surface as its original condition | — | 730.00 | — | — | |
| — | — | — | 11,400 | ||
| Extra cost for conceal wiring for main / submain with respect to PVC conduit / casing including make good of wall surface as its original condition | — | 600.00 | — | — | |
| — | — | — | 1,06,820 | ||
| Extra cost involvement for modular switch, bell push, plug socket, fan regulator, USB point, TV socket etc. with other accessories ( Make of Modular switch, socket, box, cover plate etc. - ABB / Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) ) | — | 1090.00 | — | — | |
| — | — | — | 19,533 | ||
| Wiring of AC Machine ( Window / Split ) / Water Cooler point by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) and each switch board comprising with one power unit which includes one double pole MCB, one single phase starter and one 6/16A 3 pin socket and plug with indicating light and all other associated work ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 17.00 | — | — | |
| — | — | — | 5,00,000 | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 4 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for 03 phases and 01 neutral in GI conduit of 25mm dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 1000.00 | — | — | |
| — | — | — | 2,17,500 | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for phase and neutral in GI conduit of suitable dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 1500.00 | — | — | |
| — | — | — | 35,100 | ||
| Fixing, connection and commissioning of Street Light luminaire with suitable dia heavy gauge GI bend pipe with GI clamps made of GI flat of size 40mm x 6mm and GI nut-bolts on structure / wall ( LED Street / Flood / Highbay light fitting will be supplied by Railway ) | — | 150.00 | — | — | |
| — | — | — | 22,200 | ||
| Fixing, connection, testing and commissioning of indoor LED luminaire fittings with suitable arrangement. ( LED indoor light fitting will be supplied by Railway ) | — | 300.00 | — | — | |
| — | — | — | 10,400 | ||
| Fixing, connection and commissioning of BLDC Ceiling fan with suitable size GI clamps made of GI flat and GI nut-bolts. ( BLDC Ceiling Fan will be supplied by Railway ) | — | 200.00 | — | — | |
| — | — | — | 4,950 | ||
| Fixing, connection and commissioning of AC Exhaust Fan with suitable size and shape GI clamps / GI nut & bolts including necessary masonry work ( AC Exhaust Fan will be supplied by Railway ) | — | 30.00 | — | — | |
| — | — | — | 730 | ||
| Installation, connection and commissioning of Wall Bracket fan with GI clamps made of GI flat of suitable size and GI nut-bolts on wall / structure. ( Wall Bracket Fan will be supplied by Railway ) | — | 10.00 | — | — | |
| — | — | — | 1,970 | ||
| Installation, connection and commissioning of Air Circulator Bracket fan with GI clamps made of GI flat of suitable size and GI nut-bolts on wall / structure. ( Air Circulator Bracket Fan will be supplied by Railway ) | — | 10.00 | — | — | |
| — | — | — | 41,03,200 | ||
| Supply of Dry Type Resin casted 750 KVA capacity, 6KV / 415V, 50 Hz, Outdoor type Transformer, Vector Group :- Dyn11 ( 6 KV Delta connection, 415V Star connection ), Insulation Class - H, copper winding, Air natural cooling with off load tap changing links and as per reference standard IS 2026-11 & IEC 60076-11 complete with powder coated MS sheet encloser with fully covered HV & LV Cable terminal box. ( Make - Hitachi ABB / Siemens / Voltamp Transformers Ltd. / Kirloskar Electric Company Ltd. / BHEL ) ( Please see detailed technical specification ) | — | 2.00 | — | — | |
| — | — | — | 2,05,160 | ||
| Installation, connection, testing and commissioning of above 750 KVA dry type transformers including dismantling of existing transformer along with all supporting structure of transformer shed and shifting of released transformers from Sub-station to Howrah Power House store with transportation, loading and unloading work including reconstruction / recommi- ssioning of shed with necessary modification and repairing of civil work of shed and structure after commissioning of two nos. new transformer. | — | 2.00 | — | — | |
| — | — | — | 2,22,304 | ||
| Supply of cubicle LT panel boards, made of 14 SWG (2mm) MS sheet duly powder coated for APFC Capacitor Bank consisting with the following : a) Super Heavy Duty Capacitor ( MPP ) suitable for 3 Ph, 440V, 50 Hz supply system (25 KVAR x 4 nos.) - 100 KVAR b) Power Factor Controller similar to EPCOS Model No. BR 6000 series or equivalent including CT's - 1 no. c) Capacitor Contactor suitable for operation on 3 Ph, 440V, 50 Hz supply system suitable for 25 KVAR capacitor - 4 nos. d) MCCB, TP, 320-400A, 415V, 50 Hz, 50 kA - 1 no. Complete with CTs, Ammeter, Voltmeter, Selector Switches for ammeter and voltmeter, LED indication lamps for Phases and ON / OFF indication for breaker including fabrication and copper banking ( Make for Capacitor - EPCOS / ABB / Siemens / Keltron / Havells / Alcon / Usha ) ( Make for Power Factor Controller and Contactor etc. - LK (L&T) / Siemens / ABB / Schneider / EPCOS ) ( Make for MCCB etc. - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) ( Make for Meters - Secure / LK (L&T) / Genus / Conzerv / Selec / Rishabh / Socomec / C&S ) | — | 2.00 | — | — | |
| — | — | — | 11,116 | ||
| Fixing, connection, testing and commissioning of above panel including all incoming and outgoing cables glanding, cable socketing and connection and construction of concrete foundation or suitable wall hanging arrangement as per site condition with all associated accessories | — | 2.00 | — | — | |
| — | — | — | 91,520 | ||
| Supply of Lightning Air Terminal with below specifications : a) Stainless Steel Material 316L which is suitable for corrosive Environment b) CPRI (Government of India) Laboratory - Tested & Certified for 70kA (8/20 Micro Second) c) Lightning Impulse Current Tested - 100kA (10/350 micro sec) from NFC 17-102 Accredited International Lab. d) Triggering Time (delta T) = delta 60 micro seconds e) Mechanical Test, Environment test ( Salt Mist Treatment, Humid Sulphurous atmosphere treatment ) f) 20 Year Warranty g) CE certified h) Protection Radius - 107 Metre ( Level IV / Standard ) similar to Model - VTR/ESE/RP/107 or equivalent including installation, testing and commissioning. ( Make : ABB / VTR / Raychem / Veraizen Earthing / Ennob / True Power Ltd. ) | — | 1.00 | — | — | |
| — | — | — | 11,730 | ||
| Supply of GI High Mast 5 Meter Long ( 3 Meter + 2 Meter ) with below specifications : a) 58 mm outer dia b) High Mast Pipe Wall Thickness 3.5 mm c) Base Plate 300mm X 300mm X 8mm including installation, testing and commissioning which includes necessary Mounting arrangement i.e. Guy Wire, U Clips, Insulators, Nut Bolt and Fasteners etc. along with all other accessories. ( Make : ABB / VTR / Raychem / Veraizen Earthing / Ennob / True Power Ltd. ) | — | 1.00 | — | — | |
| — | — | — | 29,220 | ||
| Supply of Single Core 70 sq.mm insulated Copper Flexible Down Conductor cable tested by 100 kA impulse test at 10/350 Microsecond for connection from Air Terminal to Earth Pit including laying of cable with necessery metallic / PVC protective covering wherever exposed to human intervention with suitable arrangement, testing and commissioning of cable. ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 30.00 | — | — | |
| — | — | — | 12,963 | ||
| Supply of 6 Digit Mechanical Lightning Strike Counter with IP67 enclosure box which will count the number of strike events including installation, testing and commissioning. ( Make : ABB / VTR / Raychem / Veraizen Earthing / Ennob / True Power Ltd. ) | — | 1.00 | — | — | |
| — | — | — | 3,338 | ||
| Supply of Test Link Box with IP67 enclosure box with accessories including installation, testing and commissioning. ( Make : ABB / VTR / Raychem / Veraizen Earthing / Ennob / True Power Ltd. ) | — | 1.00 | — | — | |
| — | — | — | 28,116 | ||
| Supply of Maintenance Free Copper Bonded Solid Earthing Rods with 25 kg Earth Enhance Compound with below specifications : a) Certified by CPRI and NABL Accredaited Lab b) ROHS certified c) Low Carbon High Tensile Rod d) Length of Electrode 3000 mm (3 Meter) e) Rod dia 17.2 mm f) Molecular Copper Plating thickness 254 microns as per UL 467 g) Connection terminal size 32 mm x 6 mm with 10 mm hole along with nut bolt and washer including installation, testing and commissioning as per RDSO spec. no. RDSO/SPN/197 ver. 1.0 or latest and conforming to RDSO Drg. No. SDO/RDSO/E&B/001 or latest. ( Make : ABB / VTR / Raychem / Veraizen Earthing / Ennob / True Power Ltd. / OBO Bettermann ) | — | 3.00 | — | — | |
| — | — | — | 1,977 | ||
| Supply of Heavy Duty Fiber Reinforced Polymers Pit Cover with below specifications : a) Weight Carrying Capacity 5 Ton b) Lockable arrangement c) Top Dia 162 mm d) Bottom Dia 242 mm e) Height 230 mm f) As per IEC 62561-5 g) M5 Nut Bolts HDG 4.6, 30 mm length with 2 nos. of plain washer h) Tested by NABL Accrediated LAB including installation, testing and commissioning. ( Make : ABB / VTR / Raychem / Veraizen Earthing / Ennob / True Power Ltd. / OBO Bettermann ) | — | 3.00 | — | — | |
| — | — | — | 3,55,776 | ||
| Supply of LT cubicle type indoor wall / floor mounted Distribution Panel Board made of 14 SWG ( 2mm ) MS sheet duly powder coated comprising with the following items with complete SCADA compatible remote operation and monitoring facility : a) MCCB with Microprocessor Release of breaking capacity 36kA at 415V, AC 50Hz ( Ics = 100% Icu ) with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt ground fault protection, 4) Inbuilt Instantaneous protection, 5) Adjustable neutral overload protection, 6) Provision of Thermal Memory, 7) Microprocessor protection- based MCCB must have facility of individual 'LSIG' fault indication suitable for Release Range ( 63-160 )Amp, 4 Pole - 1 no. b) MCCB, 4 Pole, ( 63-160 )Amp, 415V, 50Hz, 36kA, ( Ics = 100% Icu ) Microprocessor based release with above features mentioned in (a) - 5 nos. c) Tinned Copper Busbar ( 4 Bar ) each of capacity 300 Amps., 415V, 50 Hz, 50kA - 1 set d) Static Multifunction panel mounting LED Energy Meter suitable for operation on 3Ph, 415V, 50Hz supply, Cl 1 with provision of RS485 having display parameters - V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours, On hours, Phase angle, Interrupts, THD, Events ( High-Low ), Neutral Current, K Factor - 6 nos. e) CT of suitable ratio for MFM & Ammeter - 18 nos. f) LED indication lamp for Phases and "ON, OFF & TRIP" indication for operating status of breakers - 21 nos. complete with all other accessories like control cable, MCBs, gland, socket, fuse, push button, TNC switch, selector switch, rotary handle operating mechanism, spreader terminals, interlocking arrangement, auxiliary contacts, shunt release, terminal blocks & NO/NC relays for SCADA RTU connectivity etc. with internal wiring by single core FRLS grade copper conductor cable of suitable size and 1100V grade along with fabrication work, cable glanding, socketing etc. for above panel. ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) ( Make for Energy Meter - ABB / Schneider / Secure / Legrand / LK (L&T) / Genus / Conzerv / Elmeasure / Stelmec / HPL / Socomec / Anchor / C&S ) | — | 1.00 | — | — | |
| — | — | — | 17,789 | ||
| Fixing, connection, testing and commissioning of above panel including all incoming and outgoing cables glanding, cable socketing and connection and construction of concrete foundation or suitable wall hanging arrangement as per site condition with all associated accessories | — | 1.00 | — | — | |
| — | — | — | 11,18,820 | ||
| Supply of LT cubicle type indoor wall / floor mounted Distribution Panel Board made of 14 SWG ( 2mm ) MS sheet duly powder coated comprising with the following items with complete SCADA compatible remote operation and monitoring facility : a) MCCB with Microprocessor Release of breaking capacity 36kA at 415V, AC 50Hz ( Ics = 100% Icu ) with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt ground fault protection, 4) Inbuilt Instantaneous protection, 5) Adjustable neutral overload protection, 6) Provision of Thermal Memory, 7) Microprocessor protection- based MCCB must have facility of individual 'LSIG' fault indication suitable for Release Range ( 160-400 )Amp, 4 Pole - 2 nos. b) MCCB, 4 Pole, ( 63-160 )Amp, 415V, 50Hz, 36kA, ( Ics = 100% Icu ) Microprocessor based release with above features mentioned in (a) - 5 nos. c) MCCB, 4 Pole, ( 40-100 )Amp, 415V, 50Hz, 36kA, ( Ics = 100% Icu ) Microprocessor based release with above features mentioned in (a) - 5 nos. d) Tinned Copper Busbar ( 4 Bar ) each of capacity 500 Amps., 415V, 50 Hz, 50kA - 1 set e) Static Multifunction panel mounting LED Energy Meter suitable for operation on 3Ph, 415V, 50Hz supply, Cl 1 with provision of RS485 having display parameters - V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours, On hours, Phase angle, Interrupts, THD, Events ( High-Low ), Neutral Current, K Factor, Maximum Demand (kW & kVA), Bi- directional (Import- Export) Energy integrating facility etc. - 2 nos. f) Static Multifunction panel mounting LED Energy Meter suitable for operation on 3Ph, 415V, 50Hz supply, Cl 1 with provision of RS485 having display parameters - V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours, On hours, Phase angle, Interrupts, THD, Events ( High-Low ), Neutral Current, K Factor - 10 nos. g) Flush mounting 96 x 96mm, 3Ph LED Voltmeter, Cl 1, Input voltage measurement range 50-520V AC (P-P), Aux. supply 80-300V AC, Inbuilt selector switch for 3 phase measurement, site programmable - 2 nos. h) Flush mounting 96 x 96mm, 3Ph LED Ammeter, Cl 1, CT secondary site selectable 1A / 5A, Aux. supply 80-300V AC, Inbuilt selector switch for 3 phase measurement, site programmable - 2 nos. i) CT of suitable ratio for MFM & Ammeter - 36 nos. j) LED indication lamp for Phases and "ON, OFF & TRIP" indication for operating status of breakers - 42 nos. complete with all other accessories like control cable, MCBs, gland, socket, fuse, push button, TNC switch, selector switch, rotary handle operating mechanism, spreader terminals, interlocking arrangement, auxiliary contacts, shunt release, terminal blocks & NO/NC relays for SCADA RTU connectivity etc. with internal wiring by single core FRLS grade copper conductor cable of suitable size and 1100V grade along with fabrication work, cable glanding, socketing etc. for above panel. ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) ( Make for Meter & Energy Meter - ABB / Schneider / Secure / Legrand / LK (L&T) / Genus / Conzerv / Elmeasure / Stelmec / HPL / Socomec / Anchor / C&S ) | — | 1.00 | — | — | |
| — | — | — | 55,941 | ||
| Fixing, connection, testing and commissioning of above panel including all incoming and outgoing cables glanding, cable socketing and connection and construction of concrete foundation or suitable wall hanging arrangement as per site condition with all associated accessories | — | 1.00 | — | — | |
| — | — | — | 5,01,322 | ||
| Supply of LT cubicle type indoor wall / floor mounted Distribution Panel Board made of 14 SWG ( 2mm ) MS sheet duly powder coated comprising with the following items with complete SCADA compatible remote operation and monitoring facility : a) MCCB with Microprocessor Release of breaking capacity 36kA at 415V, AC 50Hz ( Ics = 100% Icu ) with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt ground fault protection, 4) Inbuilt Instantaneous protection, 5) Adjustable neutral overload protection, 6) Provision of Thermal Memory, 7) Microprocessor protection- based MCCB must have facility of individual 'LSIG' fault indication suitable for Release Range ( 100-250 )Amp, 4 Pole - 1 no. b) MCCB, 4 Pole, ( 63-160 )Amp, 415V, 50Hz, 36kA, ( Ics = 100% Icu ) Microprocessor based release with above features mentioned in (a) - 2 nos. c) MCCB, 4 Pole, ( 40-100 )Amp, 415V, 50Hz, 36kA, ( Ics = 100% Icu ) Microprocessor based release with above features mentioned in (a) - 5 nos. d) Tinned Copper Busbar ( 4 Bar ) each of capacity 300 Amps., 415V, 50 Hz, 50kA - 1 set e) Static Multifunction panel mounting LED Energy Meter suitable for operation on 3Ph, 415V, 50Hz supply, Cl 1 with provision of RS485 having display parameters - V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours, On hours, Phase angle, Interrupts, THD, Events ( High-Low ), Neutral Current, K Factor, Maximum Demand (kW & kVA), Bi- directional (Import- Export) Energy integrating facility etc. - 1 no. f) Static Multifunction panel mounting LED Energy Meter suitable for operation on 3Ph, 415V, 50Hz supply, Cl 1 with provision of RS485 having display parameters - V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours, On hours, Phase angle, Interrupts, THD, Events ( High-Low ), Neutral Current, K Factor - 7 nos. g) CT of suitable ratio for MFM - 24 nos. h) LED indication lamp for Phases and "ON, OFF & TRIP" indication for operating status of breakers - 27 nos. complete with all other accessories like control cable, MCBs, gland, socket, fuse, push button, TNC switch, selector switch, rotary handle operating mechanism, spreader terminals, interlocking arrangement, auxiliary contacts, shunt release, terminal blocks & NO/NC relays for SCADA RTU connectivity etc. with internal wiring by single core FRLS grade copper conductor cable of suitable size and 1100V grade along with fabrication work, cable glanding, socketing etc. for above panel. ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) ( Make for Meter & Energy Meter - ABB / Schneider / Secure / Legrand / LK (L&T) / Genus / Conzerv / Elmeasure / Stelmec / HPL / Socomec / Anchor / C&S ) | — | 1.00 | — | — | |
| — | — | — | 25,066 | ||
| Fixing, connection, testing and commissioning of above panel including all incoming and outgoing cables glanding, cable socketing and connection and construction of concrete foundation or suitable wall hanging arrangement as per site condition with all associated accessories | — | 1.00 | — | — | |
| — | — | — | 8,04,768 | ||
| Supply of LT cubicle type indoor wall / floor mounted Distribution Panel Board made of 14 SWG ( 2mm ) MS sheet duly powder coated comprising with the following items with complete SCADA compatible remote operation and monitoring facility : a) MCCB with Microprocessor Release of breaking capacity 36kA at 415V, AC 50Hz ( Ics = 100% Icu ) with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt ground fault protection, 4) Inbuilt Instantaneous protection, 5) Adjustable neutral overload protection, 6) Provision of Thermal Memory, 7) Microprocessor protection- based MCCB must have facility of individual 'LSIG' fault indication suitable for Release Range ( 160-400 )Amp, 4 Pole - 2 nos. b) MCCB, 4 Pole, ( 63-160 )Amp, 415V, 50Hz, 36kA, ( Ics = 100% Icu ) Microprocessor based release with above features mentioned in (a) - 5 nos. c) MCCB, 4 Pole, ( 40-100 )Amp, 415V, 50Hz, 36kA, ( Ics = 100% Icu ) Microprocessor based release with above features mentioned in (a) - 5 nos. d) Tinned Copper Busbar ( 4 Bar ) each of capacity 500 Amps., 415V, 50 Hz, 50kA - 1 set e) Static Multifunction panel mounting LED Energy Meter suitable for operation on 3Ph, 415V, 50Hz supply, Cl 1 with provision of RS485 having display parameters - V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours, On hours, Phase angle, Interrupts, THD, Events ( High-Low ), Neutral Current, K Factor, Maximum Demand (kW & kVA), Bi- directional (Import- Export) Energy integrating facility etc. - 2 nos. f) Static Multifunction panel mounting LED Energy Meter suitable for operation on 3Ph, 415V, 50Hz supply, Cl 1 with provision of RS485 having display parameters - V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours, On hours, Phase angle, Interrupts, THD, Events ( High-Low ), Neutral Current, K Factor - 10 nos. g) Flush mounting 96 x 96mm, 3Ph LED Voltmeter, Cl 1, Input voltage measurement range 50-520V AC (P-P), Aux. supply 80-300V AC, Inbuilt selector switch for 3 phase measurement, site programmable - 2 nos. h) Flush mounting 96 x 96mm, 3Ph LED Ammeter, Cl 1, CT secondary site selectable 1A / 5A, Aux. supply 80-300V AC, Inbuilt selector switch for 3 phase measurement, site programmable - 2 nos. i) CT of suitable ratio for MFM & Ammeter - 36 nos. j) LED indication lamp for Phases and "ON, OFF & TRIP" indication for operating status of breakers - 42 nos. complete with all other accessories like control cable, MCBs, gland, socket, fuse, push button, TNC switch, selector switch, rotary handle operating mechanism, spreader terminals, interlocking arrangement, auxiliary contacts, shunt release, terminal blocks & NO/NC relays for SCADA RTU connectivity etc. with internal wiring by single core FRLS grade copper conductor cable of suitable size and 1100V grade along with fabrication work, cable glanding, socketing etc. for above panel. ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) ( Make for Meter & Energy Meter - ABB / Schneider / Secure / Legrand / LK (L&T) / Genus / Conzerv / Elmeasure / Stelmec / HPL / Socomec / Anchor / C&S ) | — | 1.00 | — | — | |
| — | — | — | 40,238 | ||
| Fixing, connection, testing and commissioning of above panel including all incoming and outgoing cables glanding, cable socketing and connection and construction of concrete foundation or suitable wall hanging arrangement as per site condition with all associated accessories | — | 1.00 | — | — | |
| — | — | — | 75,660 | ||
| Supply of SPN DB ( Metal Enclosure with Metal Door ), 8 way, 50Hz, complete with 4 nos. SP MCB of current rating from 6A to 32A, 10kA, 240V, 50Hz as per requirement of load and 1 no. DP RCBO of current rating 40A, 300mA, 10kA, 230V, 50Hz ( Make of MCB, RCBO and Metal Distribution Board - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S / Havells ) | — | 15.00 | — | — | |
| — | — | — | 1,815 | ||
| Fixing, connection and commissioning of above SPN MCB DB with suitable arrangement including all incoming and outgoing cable connection with suitable cable termination arrangement. | — | 15.00 | — | — | |
| — | — | — | 1,72,665 | ||
| Supply of TPN MCB DB ( Metal Enclosure with Metal Door - IP 43 ), 3Ph, 4 way per phase, 415V, 50Hz, complete with 4 nos. SP MCB of current rating from 6A to 32A, 10kA, 240V, 50Hz per phase as per requirement of load and 1 no. FP RCBO, of current rating 63A, 300mA, 10kA, 415V, 50Hz. ( Make of MCB, RCBO and Metal Distribution Board - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S / Havells ) | — | 15.00 | — | — | |
| — | — | — | 2,055 | ||
| Fixing, connection and commissioning of above TPN MCB DB with suitable arrangement including all incoming and outgoing cable connection with suitable cable termination arrangement. | — | 15.00 | — | — | |
| — | — | — | 71,100 | ||
| Supply of MCCB with Thermal - Magnetic Release of breaking capacity 36 kA at 415V AC, 50Hz of capacity 25-32A / 32-40A / 40-50A, 4 Pole complete with metal enclosure with spreader terminals including fixing, connection, testing and commissioning. ( Make - L&T /Siemens / ABB / Hager / Legrand / Schneider / C&S ) | — | 12.00 | — | — | |
| — | — | — | 15,00,000 | ||
| Laying of cable underground through 100 mm diameter HDPE pipe by Micro Tunneling cable laying method including supply and jointing of HDPE pipe (PE-100 grade, PN-10 or higher). ( Cable will be supplied by Railway ) | — | 1000.00 | — | — | |
| — | — | — | 91,200 | ||
| Trenching and laying of cable under ground by soil cutting through suitable dia HDPE pipe including supply of HDPE pipe (PE-100 grade, PN-10 or higher) alongwith refiling of trench by excavated soil and make good of surface as its original condition. ( Cable will be supplied by Railway ) | — | 600.00 | — | — | |
| — | — | — | 47,500 | ||
| Trenching, laying under road / track through 100 mm dia GI pipe ( medium gauge ) including supply of GI pipe and commi- ssioning of cable including back filling of trench with excavated soil after laying of cable ( Cable will be supplied by Railway ) | — | 100.00 | — | — | |
| — | — | — | 2,10,900 | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting and commissioning of cable through 80mm dia GI pipe including supply of GI pipe alongwith make good of floor surface as its original condition after laying of cable ( Cable will be supplied by Railway ) | — | 300.00 | — | — | |
| — | — | — | 42,500 | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting and commissioning of cable alongwith make good of floor surface as its original condition after laying of cable ( Cable will be supplied by Railway ) | — | 500.00 | — | — | |
| — | — | — | 48,000 | ||
| Drawing of cable on wall / structure with suitable size and shape GI clamps including supply of suitable size GI Clamp and GI nut- bolts and commissioning of cable ( Cable will be supplied by Railway ) | — | 1200.00 | — | — | |
| — | — | — | 1,21,772 | ||
| Supply of heavy gauge GI fabricated Cable tray with GI supporting structure and GI nut-bolts and washer of suitable sizes as per site requirement including fixing and commissioning. | — | 2.00 | — | — | |
| — | — | — | 51,830 | ||
| Supply of Straight Through jointing kits ( Heat shrinkable ) suitable for XLPE / PVC insulated stranded Aluminium conductor cable of size 3 x 120-150 sq.mm., 11 KV grade complete with all accessories including jointing, testing and commissioning. ( Make - m-seal / Raychem / Mahindra / Densons / 3M / Polycab ) | — | 2.00 | — | — | |
| — | — | — | 20,980 | ||
| Supply of Indoor End Termination jointing kits ( Heat shrinkable ) suitable for XLPE / PVC insulated stranded Aluminium conductor cable of size 3 x 120-150 sq.mm., 11 KV grade complete with all accessories including jointing, testing and commissioning. ( Make - m-seal / Raychem / Mahindra / Densons / 3M / Polycab ) | — | 2.00 | — | — | |
| — | — | — | 5,374 | ||
| Supply of Straight Through jointing kits ( Heat shrinkable ) suitable for XLPE / PVC insulated stranded Aluminium conductor cable of size 4 / 3.5 x 50-95 sq.mm., 1100V grade complete with all accessories including jointing, testing and commissioning. ( Make - m-seal / Raychem / Mahindra / Densons / 3M / Polycab ) | — | 2.00 | — | — | |
| — | — | — | 6,488 | ||
| Supply of Straight Through jointing kits ( Heat shrinkable ) suitable for XLPE / PVC insulated stranded Aluminium conductor cable of size 4 / 3.5 x 120-185 sq.mm., 1100V grade complete with all accessories including jointing, testing and commissioning. ( Make - m-seal / Raychem / Mahindra / Densons / 3M / Polycab ) | — | 2.00 | — | — | |
| — | — | — | 7,576 | ||
| Supply of Straight Through jointing kits ( Heat shrinkable ) suitable for XLPE / PVC insulated stranded Aluminium conductor cable of size 4 / 3.5 x 225-300 sq.mm., 1100V grade complete with all accessories including jointing, testing and commissioning. ( Make - m-seal / Raychem / Mahindra / Densons / 3M / Polycab ) | — | 2.00 | — | — | |
| — | — | — | 10,556 | ||
| Supply of Straight Through jointing kits ( Heat shrinkable ) suitable for XLPE / PVC insulated stranded Aluminium conductor cable of size 4 x 400 sq.mm., 1100V grade complete with all accessories including jointing, testing and commissioning. ( Make - m-seal / Raychem / Mahindra / Densons / 3M / Polycab ) | — | 2.00 | — | — | |
| — | — | — | 17,370 | ||
| Supply of Sheet Moulded Compound ( SMC ) JB box, fire retardant of size 450 x 375 x 200 mm ( IP-55 ) / equivalent size heavy duty, outdoor type, UV ray protected, self fire- extinguishing, shock resistance IK08 or above and IP65 degree of protection grade transparent polycarbonate DB box including fitment with suitable size and shape Mild Steel ( MS ) bracket by replacing existing damage box and accessories if any with testing and commissioning. ( Make : Hensel / Sintex / OBO Bettermann / RMC / Grasp / ABB / Legrand / Spelsberg / EPP Composites ) | — | 6.00 | — | — | |
| — | — | — | 16,240 | ||
| Supply of LED Signage Board containing script of officer's designation made of high quality acrylic 8mm sheet with laser make - acast / ub / astari, in aluminium extruded slot of 24g and Light Emitting Diodes - Red & Green ( Make / brand of LED chip - NICHIA, OSRAM, SEOUL, PHILIPS, LUMILEDS, AVAGO, CREE ) complete with necessary electronic driver and all other accessories including fixing, connection, testing and commissioning of LED Signage Board with suitable clamps / fixtures. | — | 10.00 | — | — | |
| — | — | — | 28,830 | ||
| Installation, testing and commissioning of 1.5 TR Split AC machine including outdoor unit with MS angle stand including necessary power cable and all other accessories. ( Split AC machine will be supplied by Railway ) | — | 15.00 | — | — | |
| — | — | — | 50,175 | ||
| Supply of Refrigerant Copper Pipe line of required size and length with nitrile rubber insulation and all other accessories including fixing, testing and commissioning of above pipe line for above Split AC units. | — | 75.00 | — | — | |
| — | — | — | 10,300 | ||
| Supply of Drainage system for each above Split & Window AC machine for discharge of condensate water with all accessories by 1.5 inch dia PVC pipe and drain line of each machine connected by 0.5 inch cotton braided PVC flexible pipe with all other accesso- ries along with fitment and commissioning. | — | 100.00 | — | — | |
| — | — | — | 9,948 | ||
| Earthing with 2 nos.of 50 mm diametre, 3.0 metres long heavy gauge GI pipe ( Make - Tata / Jindal / Bansal ) including construction of earth pit and necessary earth connection from pit by suitable Galvanized Iron ( GI ) strip. ( For details not covered in this specifications, Indian Standard Code of Practice for earthing IS : 3043 - 1987, Reaffirmed - 1996 should be followed ) | — | 4.00 | — | — | |
| — | — | — | 60,589 | ||
| Supply of Gl Flat for Earth Bus including connection from "earth pit and fixing and commissioning on Sub-station " building wall by Gl nut-bolts and washer with supporter for earthing of HT and LT equipments | — | 1.00 | — | — | |
| — | — | — | 37,650 | ||
| Supply, installation and commissioning of different size and suitable width self- illuminated LED display system with all necessary accessories : 1) Aluminium panel - 3mm Pvdf coated aluminium composite panel.(Make-Alstone/Aludecor/Alstom/ Timexbond ) Designed artwork by ER shall be on router cut 3D alphabets of 2" depth to be flushed with the ACP sheet. 2) 1" X 1" 18g MS square pipe structure with red oxide and white enamel paint, ISI marked. 3) Imported translucent Acrylic sheet for making alphabets : a) Physical form - Sheets b) Thickness range - 3mm (+/-) 0.5mm c) Colour - White mild translucent d) Outdoor Stability - UV Stabilised e) Output - Excellent to cast Vinyl and self display f) Make - acast / Mitsubishi / sumiplex 4) 26g Galvanised iron sheet / 3mm acp for back panel. ( Make - Tata / Jindal / Bansal ) 5) Light Emit- -ting Diodes ( LED ) sign modules - ( Make of LED chip - NICHIA/ CRE / OSRAM/ SEOUL/ PHILIPS/ LUMILEDS/ AVAGO ) a) Power consumption - 1 W each module b) Operating Temperature - (-) 40 deg to 60 deg C c) Viewing Angle - 150 degree d) Input Voltage - 12V DC e) Protection Class inbuilt - IP 66 or higher f) Standards - UL94HB g) Certifications - UL. CE. C tick. ROHS h) Housing material of the module - PC & ROHS compliant i) Colour - White / Red / Warm white 6) Power Drivers -( Make-Union / Meanwell or similar ) a) Protection Class - IP 65 b)Rated Supply Voltage - 108V - 305V AC c) Fre- -quency - 50/60 Hz d) Power Factor - greater than 0.9 e) Driver Output current - .8A to 25 Ampere f) Operating Temperature - (-) 40 deg to 60 deg C g) Output Voltage Tolerance -10% | — | 50.00 | — | — | |
| — | — | — | 49,132 | ||
| Sub-station earth by supply, digging and insertion of earth pipe made of heavy gauge GI pipe of size 50 mm dia x 3 mtrs.long ( Make - Tata / Jindal / Bansal ) including construction of total 4 nos. earth pit as per Sr.DEE/G/E.Rly/HWH's drg. no. Misc./ 10/Rev. Each earth pit provided with 3 nos. of above pipe duly sorted by GI strip of size 50 mm x 6 mm including necessary earth connection from pit to CSS / HT / LT panel board / transfor- mers etc. by GI strip of size 50mm x 6mm with GI nuts & bolts. | — | 2.00 | — | — | |
| — | — | — | 20,97,737 | ||
| Goods & Services Tax ( at present @ 18% ) | — | 1.00 | Lumpsum | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .