Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 CrAdmitted-Finance AASHIYANA GARDEN PHASE 4 CHIRA CHAS BOKARO JHARKHAND | BOKARO | BOKARO | JHARKHAND | ₹2.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.7 Cr+₹3,651.96 (0.01%)Admitted-Finance | ₹2.7 Cr+₹3,651.96 (0.01%) | L2 | Admitted-Finance |
| 3 | L3₹2.8 Cr+₹7.3 L (2.71%)Admitted-Finance MANSINGHDIH BENGABAD GIRIDIH JH 815312 | GIRIDIH | JHARKHAND | 815312 | ₹2.8 Cr+₹7.3 L (2.71%) | L3 | Admitted-Finance |
| 4 | L4₹2.8 Cr+₹7.5 L (2.78%)Admitted-Finance 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | ₹2.8 Cr+₹7.5 L (2.78%) | L4 | Admitted-Finance |
| 5 | L5₹2.8 Cr+₹8.6 L (3.20%)Admitted-Finance GIRIDIH | ₹2.8 Cr+₹8.6 L (3.20%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Ms Surendra Narayan Deo L5 | MS Preeti Enterprises L6 | Manish Kumar Singh L3 | M/S SARVODAYA CONSTRUCTION L1 | RAJ CONSTRUCTION L4 | M/s INDIAAZ CONSTRUCTION AND CONSULTANT L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth a obtained to a distance up to 50M including all lifts with leveling ramming the foundation trenches removing roots of trees shurbs all complete as per approved design and per building specification and direction of E/I. | 766.71 | M3 | 109.36 ₹83,847.62 | 80 ₹61,336.96 Lowest | 100 ₹76,671.2 | 89.54 ₹68,651.39 | 92.12 ₹70,629.51 | 103.89 ₹79,653.71 |
| 2.00 | Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B) | 684 | M3 | 11.17 ₹7,640.28 | 90 ₹61,560 | 15 ₹10,260 | 9.15 ₹6,258.6 Lowest | 9.4 ₹6,429.6 | 10.61 ₹7,257.24 |
| 3.00 | Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume). | 679.12 | M3 | 39.82 ₹27,042.48 | 32 ₹21,731.78 | 30 ₹20,373.54 Lowest | 32.6 ₹22,139.25 | 33.54 ₹22,777.62 | 37.83 ₹25,691.03 |
| 4.00 | Providing coarse clean sand in filling in foundation trenches or plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts includng cost of all materials, Labour, rotalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume). | 438.14 | M3 | 223.35 ₹97,859.69 | 190 ₹83,247.55 | 200 ₹87,629 | 182.88 ₹80,127.96 Lowest | 188.15 ₹82,436.98 | 212.18 ₹92,965.61 |
| 5.00 | Providing designation 75A work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.m. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials ranking out joints to 15mm depth, curing taxes and royalty all complete as per building specification and direction of E/I. | 15.21 | M3 | 3,840.03 ₹58,418.38 | 3,600 ₹54,766.8 | 210 ₹3,194.73 Lowest | 3,144.22 ₹47,833.02 | 3,234.84 ₹49,211.62 | 3,400 ₹51,724.2 |
| 6.00 | Providing designation 75B work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.m. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials ranking out joints to 15mm depth, curing taxes and royalty all complete as per building specification and direction of E/I. | 101.66 | M3 | 2,720 ₹2,76,512.48 Lowest | 2,800 ₹2,84,645.2 | 3,500 ₹3,55,806.5 | 3,070.8 ₹3,12,174.46 | 3,159.31 ₹3,21,172.3 | 3,400 ₹3,45,640.6 |
| 7.00 | Providing designation 75Bwork in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints of screening materials, scaffolding, ranking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. | 443.59 | M3 | 2,220 ₹9,84,778.68 Lowest | 3,500 ₹15,52,579 | 3,600 ₹15,96,938.4 | 3,149.74 ₹13,97,205.77 | 3,240.51 ₹14,37,470.79 | 3,500 ₹15,52,579 |
| 8.00 | Providing designation 125mm thick reinforced designation 75A brick work in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening, carriage of materials, raking out joints to 15mm depth curing taxes and royalty (but excluding the cost of reinforcement) all complete as building specification and direction of E/I. | 701.96 | M2 | 512.03 ₹3,59,423.04 | 530 ₹3,72,037.21 | 400 ₹2,80,782.8 | 419.25 ₹2,94,295.47 | 331.33 ₹2,32,579.41 Lowest | 500 ₹3,50,978.5 |
| 9.00 | Providing P.C.C/R.C.C. M-150 with normal mix of (1:2:4) in foundation and plinth with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in cement mixer and placing in position, vibrating, skirting, curing, tax and royalty all completejob as per building specification and direction of Engineer-in-charge. | 55.6 | M3 | 4,358 ₹2,42,291.73 | 3,500 ₹1,94,589.5 Lowest | 5,000 ₹2,77,985 | 4,387.81 ₹2,43,949.07 | 4,514.27 ₹2,50,979.87 | 5,090.89 ₹2,83,038.21 |
| 10.00 | Providing P.C.C./R.C.C. M-75 with normal mix of (1:4:8) in foundation and plinth with approved quality of stone metal grade III 953.2mm to 22.4mm size) & clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in cement mixer and placing in position, vibrating, skirting, curing, tax and royalty all completejob as per building specification and direction of Engineer-in-charge. | 29.83 | M3 | 3,580.92 ₹1,06,811.68 | 3,700 ₹1,10,363.6 | 4,200 ₹1,25,277.6 | 2,932.06 ₹87,457.49 Lowest | 3,016.56 ₹89,977.95 | 3,401.87 ₹1,01,470.98 |
Tender Value
₹3.3 Cr
EMD Value
₹3.3 L
Closing Date
2 Dec 2020, 11:00 amClosed
Nodal Officer
e-Procurement Cell, Office of the Chief Engineer Combined office Building. Building Construction Department, Line Tank Road, Ranchi.
Proposed Construction of ITI and Hostel Building at Chirudih under Nawadih Block ,Dist-Bokaro
2020_BCD_46535_1
BCD/CE/08/Bokaro/2020-21
Open Tender
Civil Works - Buildings
Item Rate
330 days
Bokaro
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
EE BCD Builidng Division Bokaro
₹3.3 L
17 Dec 2020
25 Nov 2020
3 Dec 2020
25 Nov 2020
2 Dec 2020
25 Nov 2020
Amount
Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth a obtained to a distance up to 50M including all lifts with leveling ramming the foundation trenches removing roots of trees shurbs all complete as per approved design and per building specification and direction of E/I.
Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B)
Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
Providing coarse clean sand in filling in foundation trenches or plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts includng cost of all materials, Labour, rotalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume).
Providing designation 75A work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.m. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials ranking out joints to 15mm depth, curing taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 75B work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.m. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials ranking out joints to 15mm depth, curing taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 75Bwork in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints of screening materials, scaffolding, ranking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 125mm thick reinforced designation 75A brick work in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening, carriage of materials, raking out joints to 15mm depth curing taxes and royalty (but excluding the cost of reinforcement) all complete as building specification and direction of E/I.
Providing P.C.C/R.C.C. M-150 with normal mix of (1:2:4) in foundation and plinth with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in cement mixer and placing in position, vibrating, skirting, curing, tax and royalty all completejob as per building specification and direction of Engineer-in-charge.
Providing P.C.C./R.C.C. M-75 with normal mix of (1:4:8) in foundation and plinth with approved quality of stone metal grade III 953.2mm to 22.4mm size) & clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in cement mixer and placing in position, vibrating, skirting, curing, tax and royalty all completejob as per building specification and direction of Engineer-in-charge.
Providing P.C.C./R.C.C. M-100 with normal mix of (1:3:6) in foundation and plinth with approved quality of stone metal grade III 953.2mm to 22.4mm size) & clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in cement mixer and placing in position, vibrating, skirting, curing, tax and royalty all completejob as per building specification and direction of Engineer-in-charge.
Providing P.C.C./R.C.C. M-200 with normal mix of (1:1.5:3) in foundation and plinth with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I.
Providing R.C.C. M-200 in band at plinth level with nominal mix of (1:1.5:3) of approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I.
providing R.C.C. M-200 with nominal mix of (1:1.5:3) in band at lintel level with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I.
providing R.C.C. M-200 with nominal mix of (1:1.5:3) in lintel with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I.
Providing R.C.C. M-200 with nominal mix of (1:1.5:3) in roof slab with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I.
Providing R.C.C. M-200 with nominal mix of (1:1½:3) in beam of all types with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I.
Providing R.C.C. M-200with nominal mix of (1:1.5:3) in Column with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I.
Providing av. 63mm thick R.C.C. M-200 with nominal mix of (1:1.5:3) chajja with approved quality of stone chips 20mm to 10mm size graded and clean coarse sand of F.M. 2.5 to 3 including making drip course in concrete screening, centering, shuttering and mixing drip course in mixer and placing in position, vibration skirting, 6mm cement plaster (1:4) in ceiling and sides of chjja with sand of F.M. 1.5 curing (but excluding the cost of reinforecment) taxes and royalty all complete as per building specification and direction of E/I.
Providing 25mm thick Damp Proof Course with cement concrete M-200 with nominal mix of (1:1.5:3) with approved quality of stone chips of 20mm to 6mm size graded and clean course sand of F.M. 2.5 to 3 including screening, shuttering and mixing cement concrete in mixer with 5% cicio or any other approved water proffing compound and placing in position, striking, curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing R.C.C. M-200with nominal mix of (1:1.5:3) in Stair Case with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I.
Providing Precast R.C.C. M-200 with nominal mix of (1:1.5:3) slab of desired size with approved quality of stone chips and clean coarse sand of F.M. 2.5 to 3 including curing, shuttering carrying the slab manually to site and laying in position all complete (but excluding the cost of reinforcement) taxes and royalty, all complete as per building specification and direction of E/I.
S/F 35mm thick solid core type non-decorative single leaf flush door and windows with black board core banded with high quality phenol formaldehydes synthetic resin both side commercial veneered of standard make with oxidized iron fittings such as hinges, sliding door bolts tower bolts, handles or rings hooks and eyes, cleats sand block as per schedule taxes and royalty all complete as per building and direction of E/I.
S/F 35mm thick solid core type non-decorative Double leaf flush door and windows with black board core banded with high quality phenol formaldehydes synthetic resin both side commercial veneered of standard make with oxidized iron fittings such as hinges, sliding door bolts tower bolts, handles or rings hooks and eyes, cleats sand block as per schedule taxes and royalty all complete as per building and direction of E/I
Providing TMT steel reinforcement 8mm dia rods to 12mm dia as per approved design and drawing excluding carriage of M.S. roads (Straight or in coils) to work site, cutting, bending end binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I.
8mm dia-10 dia 35%
20-25mm dia 65%
Providing and fixing fan hook of 16mm dia TMT M.S. bar I meter long bent to required size and shape placed in position and fixed in RCC slab/beam at the time of casting all complete as per building specification and direction of E/I.
S/F local make collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat disgonal with top and bottom rails of T iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts nuts locking arrangements steppers handles including applying a priming coat of red lead paint carriage hoisting and taxes all complete as per building specification and direction of E/I.
S/F local make fully glazed steel door, windows or ventilation of standard rolled 'Z' and mullion steel section and size as per IS - 38 joints met welded with 100 x 16 x 3mm M.S. lug fixed in cement concrete (1:2:4) blocks, 15 x 10 x 10cm size including cost of oxidized iron fitting with hinges, handle per step catch springs, 3mm thick plain glass panes with aluminum beads and inner frame fixed with lugs with 20mm long 6.3mm GI. counter sunk machine screw and nuts and applying a coat red lead paint carriage to work site hoisting and plcing in all position in all storys and taxes all complete as per building specification and direction of E/I.
S/F 20mm dia M.S. bar 1M long holding down bolt with nuts washers 100 x 100 x 6mm plate fitted and fixed with cement concrete (1:2:4) as per approved design all complete as per building specification and direction of E/I.
Providing designation 75B one brick flat soiling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
Providing 25mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layers 19mm. Thick (1:2:4)with 12mm to 6mm. Size graded stone chips and top layer 6mm. Thicks (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I.
Providing 50mm thick 2nd class patent stone flooring (1:2:4) with 20mm, to 6mm size graded stone chips finished with flooring coat of neat cement in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I.
Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curing, taxes and royalty all complete as per building specification and direction of E/I.
Extra for providing and fixing 20mm x 4mm glas strips in joints of flooring complete as per specification and direction of E/I.
Providing and laying vitrified/ Industrial floor tiles in Different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and confirming to IS 15622/ISO 13006, of approved make , in all colour and shades laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointed with grey cement [email protected] kg /sqm including grouting the joints with white cement and matching pigment etc.Size of tiles 300x300x10mm
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
Providing 12mm thick cement plaster (1:6) -with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty as per building direction of E/I.
Providing 6mm thick cement plaster (1:4) in ceiling with coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty as per building direction of E/I.
Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I.
Water proofrng for Old and New Roof Slab :- Providing and laying waterprooflng treatment on roof slab by applying two Component, factory a designed ready to use, acrylic modified flexible,material applied with brush, roller or spray for wate proof i n g coating as per manufactlrer specificatio With following steps :-
(a)surface preparation :-Provrding and cleaning of concrete surface to remove dLrst, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from sofftt to identify seepage, leakage. On identiiication of seepage, cement grouting to be done with non shrink expanding admixture of Sika lndia Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc or equrivallent. Providing and reparing of all corners and joinis such as those betr,veen the parapet wall and the roof slab etc shall be chamfered with '150mm X '150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent Before chamfering a prime coat shall be given with the sl u rry ?!gc!ylic polyrner Repai rin g su rface irreg ularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modilied repair moriar ir;cluding a coat of bonding agent of the same with ceme nt slurry rncluding all rnaterial, labour, tools complete.
(b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, llexrble cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application ,45 gsm oI Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/SqmUcoat For the fJUrpose of n'ieasurernent tite entire treated surface will be measured."
(c) :2nd Cr:ai :-T,: apply the 2nd coat of two component acrylic modified, reatiy to-use, flexible cementttious material right angle to the '1st coat over the glass fibre liad surface. 2nd coat should be applied @0.7 kgl Sqrnt/coat. For the pltrpose of measurement the entire treated surface will be rneasurecl." Alte r three days of drying the 2nd coat, therainwater ouilets to be plugged and ponding test to be done for 48 hours to rrjerrtify se epage, leal<age from soffit and if found necessary rectification lo be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectifcation to be done as per satrsfaction of E/C protected from damage before screed over it. Watqr proofing Brand:*Sika Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2Kl MYK Aqraiin TG Product Performance - Chemical Base Part A. Acrylic copolmer, Part B Specially graded cementitious powder - Density 1.6 l.rg/l (mixcd density) at +27oC Tensile Strength - 2 lllmm2 after 28 clays (with Fibre cloth) (According to ASTM D 2370)Prillcut Bond Streric;tl-r '-2 I'J/mm2 (concrete lajlqry) (Aqgcrdlglq ISO 4624) Slant-Shear Bond Strength -4 N/mm2 (According to FIP 5.'15) Elongation at Break -35% without Fibre Cloth and 20% wilh Fibre Clot (Accordrng to ASTM D 2370)
(d) Protection of treated surface with PCC- The treated surface should be covered with 25mm/50mm PCC of M-20 grade(1:1.5:3) with proper slope ( '1:120) towards tlre rain outlets in alternatepanels of 2 mt x 2mt keeping 6 mrn gap betuieen the panel joint. lntegralwater proofing admixture conforming to lS 2645 @ of 100 ml per bag of of cement to be added in the scree d concrete(pard separately for thts ltems).-All corners shall be charrmfered with 150mm X 150 mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface slrould be packed properly with rich concrete and the peripheral mouih to be sealed with moisture insensitive epoxy putty of Sika lndia Pvt.Ltd / IVIYK Schomberg / Dr FixiUFosroc .For the purpose ofrreasurement the entire treated surface will be measured."
(e) Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand - Sika lndia Pvt Ltd / MYK Schomberg / Dr Fixit/Fosroc Warranty for Five years.
Covering of treated surface wrth PCC :- Providing 25 mm thick Cementn Concrete M20(1:'1.5:3) r'naintaining slope in alternate 2 mIx 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and clcaned sand of F M 2 5 io 3 including screening,shuttering,and mixing cerite nt c0ncrete in mixer with admixture of integral water proofing and placing rn position,strikirrg cLrring,t-a]glgnd royality all complete as per buildirrg specifictionJand direction of E/l.Panels that has been left should be casteci nextday.-lhere should be 6 mm gap between Panels.Brand- Sika *Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421ic , Dr Frx,t Prdiproof LWr
Provrding and filling of 6mm Groove between 25 mm PCC Panels with PolysLrlphide Sealant (Poring Grade)as per drawings and technical specifications and dii-ection of E in Charge (with 1B% GST).Brand:-Sika- Polysulphide, Fosroc-l-hioflex 600 Dr. Fixit Pidiseal PS(42P),MYK Seal PS or Euivallent
Providing two coat of oil bound distemper of approved shade and make over a primer coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding, washing floors and taxes all complete as per building specification and direction of E/I.
Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper scaffolding , curing and taxes all complete as per building specification and direction of E/I.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Providing two coats of synthetic enamel paint of approved shade and make over new wooden surface including preparing the surafce after cleaning, removing dirt scales, smokes, grease and sand papering, including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specificatio).
Providing primer one coat of red lead paint of approved make over steel surface including preparing the surface after cleaning removing dust, dirt. Scales amokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (mode of measurement of area shall be multiple by the co-efficient as indicated in building specification)
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
providing 150mm wide brick draing in cement mortar (1:6) with av. 150mm and 125mm apron including stacking serviceable material within 15M lead and disposal of unserviceable material with all leads all complete as per direction of E/I.-
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement:3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over75mm thick bed of dry brick ballast 40 mm nominal size, well rammedand consolidated and grouted with fine sand, including finishing the topsmooth
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
Providing and fixing 18mm thick gang saw cut, mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias nad similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treate with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade No. - 2 and M.S. top cover of required thiskness for rolling shutters.
Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness,including hinges, jamb, lock jamb, bead and if required angle threshold ofmild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressedmild steel welded or rigidly fixed together by mechanical means, includingM.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strikeplateand shock absorbers as specified and applying a coat of approved steelprimer after pre-treatment of the surface as directed by Engineerin-charge: Profile B- Fixing with adjustable lugs with split end tail to each jamb
Providing and fixing pressed steel door frames confirming to IS : 4351 manufactured from commercial mild steel sheet of 1.25mm thickness including hinges jamb, lock jamb bead and if required angle threshold of mild steel angle of section 50 x 25mm, or base ties of 1.25mm pressed mild steel welded or riidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strikeplate and shock absorbers as specified and applying a coat of approved steel primer after-treatment of the surface as directed by Engineer-in-Charge.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use ofchequered plate wherever required, all complete
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with sea; ring conforming to IS:5382, leaving 10mm gap for thermal expansion, Single socketed pipes
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Coupler - 110mm
Bend - 110mm
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and laying water proofing treatment on roofs of slabs byapplying cement slurry mixed with water proofing cement compoundconsisting of applying: a) after surface preparation, first layer ofslurry of cement @ 0.488 kg/sqm mixed with water proofing cementcompound @ 0.253 kg/sqm. b) laying second layer of Fibre glasscloth when the first layer is still green. Overlaps of joints of fibrecloth should not be less than 10 cm. c) third layer of 1.5 mmthickness consisting of slurry of cement @ 1.289 kg/sqm mixedwith water proofing cement compound @ 0.670 kg/sqm and coarsesand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hoursfollowed by water curing for 48 hours. The entire treatment will betaken upto 30 cm on parapet wall and tucked into groove in parapetall around. d) fourth and final layer of brick tiling with cement mortar(which will be paid for separately. For the purpose of measurement the entire treated surface will be measured
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) - Powder coated aluminium (minimum thickness of powdercoating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
Carriage of Material
Bricks
Stone chips
Stone Metal
Local Sand
Providing and fixing male ended 15mm dia brass bib cock of approved quality (Wt. not less than 350 gms.) with extra socket all compere as per specification and direction of E/I.
Providing and fixing brass/C.I.Stop cock of approved quality all complete as per specification and direction of E/I.
(A) BRASS STOP COCK15 mm dia
Providing and fixing G.M. non return valve Horizontal/Vertical type of approved quality as per specification and direction of E/I.
Horizontal - 32mm dia
Vertical -32mm dia
25 mm dia (Vertical)
Providing and fixing N.P./C.P. brass/PVC procelain shower rose of 15mm inlet etc. all complete as per specification and direction of E/I.
Shower Rose - 125mm
Providing and fixing G.M. full way valve of approved quality as per specification and direction of E/I.
25 mm dia
32mm dia
Cutting chhajja or corince for laying G.I. pipe and restoring the same with R.C.C. (1:2:4) brick work in cement mortor (1:4) as per specification and direction of E/I.
Making holes in walls for laying G.I. pipe and restoring the same after pipe laying as per specification and direction of E/I.
250 mm thick wall
125 mm thick wall
Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I.
Glass self
Mirror (300 x 450mm)
Mirror (600 x 450mm)
C.P. brass tower rail
C.P. brass dish container medium quality with screw and hinges etc.
Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of Parry Emdustan or any other.... all complete as per specification and direction of E/I.
Supplying, fitting and fixing 40mm high viterous white glazed earthen E.W.C. with 'p' trap of Parry/hindustan or any other approved I.S.S. make including supplying and fixing 15 liters C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grams 15mm P.V.C. alkathene pipw 45cm. long with brass coupling at both ends and white/black plastic solid state seal and lead o commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approvd paint over a coat of red oxide priming, all complete as per specification and direction of E/I.
Witl, "P" trap - 12.5 liters low level P.V.C. cistern
Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthen ware urinal of 'Hindustan "Parry" or any other approved I.S.S. make with 5 liters capacity C.I. automatic flushing cistern of reliance for any other I.S.S. approved make with all fittings with C.I. or R.S., brackets, standard size G.I. flush pipe with fitting clamps, 15mm, C.I. body brass spindle stop cock of approved quality weight not less than 400 grams, 15mm P.V.C./Alkthene pipe 450mm long with brass coupling at both ends and doing plumber joints including painting coat of red oxide cutting wall and floor making good the same etc. all complete as per specification and direction of E/I.
Flat back or standing corner (600mmx 350mm)
Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on pointed C.I. or R.S. brackets 32m C.I. brass waste 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grms. 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I.
Earth work in exacvation for laying R.C.C. spun pipe All complete job as per building specification and direction of E/I.
Labour for laying, fitting and fixing NP2 R.C.C. spun pipe with collars in lines, level and grade providing approved jointing materials and joints properly fillrs to make them lead proof including providing sight rails, bonning rod, night, guard, Red light and barrier etc. all complete as per specification and direction of E.I.
150mm dia R.C.C. spun pipe
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge 100 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range5 cm to 20 cm, in recharge pit, in the required thickness, for allleads & lifts, all complete as per direction of Engineer-in-charge
Supplying, filling, spreading & leveling gravels of size range 5 mm to10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mmto 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge
Supplying NP2 R.C.C. hume pipe with colour as work site as per direction of E/I. 150mm dia
Supplying materilas and labours for construction of inspection chewbas of designation 75B brick size 750mm deep x 600 x 450 internal dimension Direction of E.I.
Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank.
DT : Basic rates for 125/115mm dia drilled Tube-well for drilling in all kinds of soil and rock for installation of hand pump with DTH rig Machine all complete including supplying all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant, for making 125/115 mm dia boring etc. and cost of transporting rig machine and other vehicle up to site of work as per specification and direction of E/I.. (Basic Rates) Drilling upto 30 mtr. Depth below G.L. in Rural Area
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required
Kitchen sink without drain board
Kitchen sink without drain board
610x510 mm bowl depth 200 mm
610x460 mm bowl depth 200 mm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
25 mm dia
32 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
15 mm dia
20 mm dia
Providing and fixing PTMT grating of approved quality and colour.
C.P. Gratings
Circular type - 100mm dia
Circular type - 125mm dia
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Single tee with door 75x75x75 mm
Single tee with door 110x110x110 mm
Single tee without door 75x75x75 mm
Single tee without door 110x110x110 mm
75 mm bend
110 mm bend
Special type C.P. Bath room Fitting for V.I.P.Buildings(JAL, Jaquar, Mark or Equivalent)
Angular Stop Cock (2 way bib cock/ stop cock)
telephonic shower with flexible pipe
Towel rail 24''
glass shelf22''
Towel Ring
Point wiring in PVC consuit, with piano type switch - Wiring for light point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size PVC/G.I. box etc. as required
Group A
Twin control point wiring in PVC conduit, with piano type switch - Wiring for Twin Control light point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, 2 way paino type switch, phenolic laminated sheet, suitable size PVC/G.I. box etc. as required.
Wiring for light/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FRPVC insulated copper conductor single core cable in surface/recessed conduit with Modular type switch phenolic laminated sheet suitable size M.S. box and earthing the point with 1.5 sq.mm. FRPVC insulated copper conductor single core cable etc. as required
Group - C
Wiring for twin control light point with 1.5 sq.mm FRPVC insulated copper conductor single core cable in surface/Recessed PVC conduit 2 way modular switch modular plate suitable G.I. box and earthing the paint with 1.5 sq.mm FRPVC insulated copper conductor for single core cable etc. as required
Wiring for light/power plug with 2 x 4 sq.mm FRPVC insulated copper conductor single core cable in surface/recessed PVC conduit along with 1 No. sq.mm FRPVC insulated copper conductor single core cable for loop earthing as required
Wiring for Curcuit submain wiring along with earth wire with the following sizes of PVC insulated copper conductor single core cable in surface of recessed PVC sonduit as required
2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire
2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire
2 x 6 sq.mm + 1 x 6 sq.mm earth wire
2 x10sqmm. +1x10 sqmm. Earth wire
4 x 4 sq.mm + 2 x 4 sq.mm earth wire
4 x 6 sq.mm + 2 x 6 sq.mm earth wire
4 x 10 sq.mm + 2 x 10 sq.mm earth wire
4 x 16 sq.mm + 2 x 16 sq.mm earth wire
Supplying and fixing following piano type switch/socket on the existing switch box/cover including connections etc. as required.
5/6 amps, one way switch
S/F 5/6 Amp. Switch & Socket (on boarel)
S/F step fan regulator
S/F Modular switch/Socket on the existing modular plate and switch box including connection but exckuding modular plate etc. as required
5/6 amp switch & 3 pin 5/6 amp socket/outlet
S/F metal box of 150 x 75 x 60m deep on surface/recessed with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amp. Socket outlet and 5/6 amp piano type switch connection etc. as required (For light plug to be used in non residential buildings)
S/F metal box of 180 x 100 x 60m deep on surface/recessed woth suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 and 15/16 amp. Socket outlet and 15/16 amp. Piano type switch connection etc. as required
S/F 3 pin 5 amp ceiling rose on the existing junction box wooden block including connection etc. as required
S/F brass vatton/Angle Holder including connection etc. as required
S/F call bell Buzzer suitable for A.C./D.C. single phase 230 volts complete etc. as required
I.T.C. of prewired flourecent fitting with all type complete with all accessories 2 nos. down rods of 20mm dia x 1.6mm thick steel conduit up to 30 cm length etc. as required
I.T.C of ceiling fan including wiring the down rods of standard length (Up to 30 cm) with 1.5 sq.mm FRPVC with 1.5 sq.mm. FRPVC insulated copper conductor single core cable etc. as required
I.T.C of exhaust fan up to 450mm sweep in the existing opening including making the hole to suit the size of the above fan making good the damage connection testing commissioning etc. as required
S/F rewireable double pole/TP&N switch disconnector - Providing and fixing following capacity double pole/TP&N sheet metal switch disconnector fuse unit in existing metal board with rewireable type fuses, including drilling holes in metal board, making connections, etc as required.
100 amps, TP&N
Providing and fixing following rating and capacity four pole MCCB in existing cubicle panel board, including drilling holes in cubicle panel, making connections, etc. as required.
25/100 amps, 16KA, fixed thermal setting
S/F busbar chamber - Providing and fixing following capacity busbar chamber with 4 strips of suitable size made of copper, heavy duty, complete with all accessories including connections, earthing the body, etc. as required.
S/F T.P. MCB DB - Supplying and fixing following way, three pole and netural, sheet MCB ditribution board, 415 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
16 way Double Doordoor
S/F the following way single pole and nutral sheet steel M.C.B. D.B. consumer unit 240V on surface/recess complete with tinned copper busbar, nutral busbar earth plate dinbar hinged front acrylic cover fro MCB knob datachable gland plate inter connection phosphatied and powder painted including earthing etc. as reuired (Without MCB/RCCB/Isolator)
4 way (4 + 12) double door
6 Way (4 + 18( double door
S/F 5 amp. To 32 amp. Rating 240 volt "C" series miniature circuit breaker suitable for inductive load of following pole in the existing MCB DB complete with connection testing and commissioning etc. as required
Supplying and fixing following rating, double pole, 240 volts, isolator in the exisitng MCB DB complete with connections, testing and commissioning etc. as required.
S/F DP MCB isolator - Supplying and fixing following rating, double pole 240 volts, isilator in the existing MCB DB complete with connections, testing and commissioning etc. as required
S/F following rating single pole 240 volts isolator in the existing MCB DB complete with connection testing and commsissioning etc. as required
Earthing with G.I. earth pipe 4.5 mtr. Long, 40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. charcoal and salt as required.
Earthing with G.I. earth pipe 4.5 mtr. Key & 40mm dia thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required (But without charcoal or coke and salt)
Extra for using salt and coke for G.I. or copper plate earth electrode etc. as required
S/L 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode including soldering etc. as required
P/F copper lightning conductor final - Providing and fixing of lightning conductor final, made of 25mm dia 300mm long, copper tube, having single prong at top, with 85mm dia 3mm thick copper base plate base including holes etc. complete as required.
P/F of lighting G.I. final made of 25mm dia 300mm long copper tube having single prong at top with 85mm dia 3mm thick copper base plate including holes etc. complete as required
Reverting sweating and soldering of copper/G.I. tape )With another copper G.I. tape base of the final or any other metalic object) as required
P/F copper lightning conductor tape in horizontal run - Providing and fixing copper tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)
P/F copper lighning conductor tape in vertical run - Providing and fixing copper tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)
P/F G.I. tape 20mmx 3mm thick on parapet or surface of wall for lighting conductor complete as required
P/F testing joint made of 20mm x 3mm thick copper strip 125mm long with 4 nos. of tinned brass bolts nuts check nuts and spring washers etc. complete as required
S/F Vertical type Tp MCB DB 415 volts sheet steel dust protected duly phosphatised & powder painted inclusive of 200 amp tinned copper busbar common netural link earth bar dinbar for mounting MDB'S detachable gland knock out plate and with 100 Amp 10 KA MCCB as in comer inter connecting between incomer MCCB and busbar of following ways (But without MCB'S) as required 4 way with 100 amp. MCCB incomer
4 way 8 + 12 Double Door
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm. but not exceeding 120 sq.mm. direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
S/D PVC insulated 3.5 core50sqmm Al. Armoured cable.
Supplying and fixing LED Batten (20/22W) make as [per approved by E/I.
Supplying fitting &fixing LED Flood light (50/60W) make as per approved by E/I.
S/F 9/10 watt LED Bulb Make as per approved by E/I
S/F LED Bulb : Supplying and fixing of 15/16 W LED lamp in existing holder. Make:- BAJAJ/ Philips /Hevalls
Supply of Ceiling Fan 1200mm(48")
Supply of Metal Exhaust Fan 300mm (12")
Supply of exhaust Fan 15" (380mm). Make as per approved by E/I
S/F LED Bulb : Supplying and fixing of 20/22 LED batten in existing holder. Make:- BAJAJ/ Philips /Hevalls
Supplying and fixing of 45/48 W LED Light
Providing and fixing of XLPE, Aluminium Armoured PVC Cable confirming to IS IS7908 (Part-1) 1988 0f grade 1.1KV. Make:- Havells / Finolex / Polycab
3.5 Core 120 Sq. mm. 1.1 KV XLPE Al. Ar. Cable.
Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.
(a) From 0.00 M to 50.00 M below G.L.
(b) From 51.0 M to125.00 M
(c) From126.0 M to150.00 M
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp
Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP
Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I.
Supply fitting and fixing lowering 50 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I.
Non Schedule
Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes ,royalty etc all complete job as per direction of E/I.
MAIN LT PANEL:-
Supplying, installation, testing and commissioning of cubical type MV Panel made out of 14 SWG sheet steel, totally enclosed IP-54 protection, free standing, floor mounted dust and vermin proof, indoor type compartmentalized powder coated of approved shade after antirust treatment (with min seven tanks ) suitable with busbar interconnection with suitable size of copper lead/solid Aluminium strips, control circuits & bottom base channel of MS section not less than 75mmx75mmx5mm (thick), Fabrication shall be done in transportable section ,entire panel shall have a common earth busbar at rear with 2 nos earth stud cable alleys, cable gland plates in two half as required as per single line diagram & specification enclosed with the following switchgears. (Main LT panel)
INCOMER:-
315 Amp (36KA),manual,fixed,MCCB (2 Nos. )
CHANGE OVER:-
315 Amp,4 POLE (1 Nos. )
1 Set phase indication lights (R, Y, B)
1 No. Volt Meter (digital type) with inbuilt VSS & control fuses.
1 No.Ammeter (digital type) with inbuilt ASS
AL. BUSBAR CHAMBER:-
400 Amps. TP&N Aluminium bus bars (50 KA)
OUT GOINGS:-
4 pole MCB 63A,16 kA with fixed thermal magnetic setting.(5 Nos. )
4 pole MCB 40 A,16 kA with fixed thermal magnetic setting.(12 Nos. )
6/32 A,DP (5 Nos. )
TOTAL COST OF MAIN LT PANEL
Add 12 % GST
Add 1% Labour Cess
M/s INDIAAZ CONSTRUCTION AND CONSULTANT
Manish Kumar Singh
RAJ CONSTRUCTION
Ms Surendra Narayan Deo
MS Preeti Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.09 MB
BOQ_61194.xls
BOQ • 0.43 MB
SBD-08.pdf
Tender Documents • 2.85 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .