Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAccepted-AOC 601 6TH FLOOR MANGOOR VALLEY NEAR GURUDWARA MANGOOR HILLL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹5.8 L+₹3,045 (0.53%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹5.8 L+₹4,045 (0.71%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹5.9 L+₹13,305 (2.32%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹6.4 L+₹62,615 (10.9%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
16 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER ABOHAR
GARRISON ENGINEER ABOHAR PUN 152116
REPAIR / MAINT INCLUDING GEN SERVICING OF STAND BY GEN SETS AT E/M INSTALLATIONS AT MIL STN ABOHAR.
2024_MES_660344_1
TOKEN NO GE ABH-27/24-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
ABOHAR MIL STN
AS PER NIT
7 documents required · 7 mandatory
₹500
GE ABOHAR
₹20,000
Yes
1 Jan 2025
18 Jun 2024
18 Jul 2024
18 Jun 2024
16 Jul 2024
2 Jul 2024
Amount
Material and Labour for annual maintinance/ Servicing, repair of Diesel Gen Set of capacity 320/200KVA 1500 RPM at 0.8 pf, 3 phase, 415 Volts, 50 Hz, coupled with water cooled engine including dismantling and opening of unserviceable spare parts of the DG set engine and cleaning with replacement of Fuel Filter, By pass filter, lube oil Filter, Air filter (Make of these items- Ashok Layland/Crompton Greaves/Kirloskar/Mahindra. Also checking of its all parts for serviceability and replacement of defective parts(Labour cost included) and minor spares required for functioning of DG set and re-assembling complete engine testing on load to the entire satisfaction of Engr-in-Charge. MAKE: Ashok Layland/Crompton Greaves/Kirloskar/Mahindra Note :- 1. Servicing of DG Set to be carried out by Engineers of authorised dealers/service center by follwing A, B, C check. 2. All major defective/unserviceable spare parts/items reqd for replacement shall be measured and paid separetely under appropriate items as mentioned in following here-in-after. 3. Contractor should provide technical inspection of each DG Set by an engineer of corresponding make installed at site before supplying of material and incorporate the same at the site.
All as per item No. 1 but for 160 KVA DG set.
All as per item No. 1 but for 125 KVA DG set.
All as per item No. 1 but for 5 to 63 KVA DG set.
S&F Radiator hose pipe set with clamp complete for 5 to 63 KVA DG Set Make: Ashok Layland/Crompton Greaves/Kirloskar/Mahindra
S&F Radiator hose pipe set with clamp complete for 125 to 320 KVA DG Set Make: Ashok Layland/Crompton Greaves/Kirloskar/Mahindra
Labour only for attending the complaints of DG set with AMF Panel carried out by manufacture's authorised mechanic from the servicing centre without any delay for rectifying the defects by carefully opening and check the DG set parts to find out defects if any at site and replace the defected parts from the DG Set for smooth functioning as directed and specified by the Engr in charge at site (Replacement of parts shall be measured and paid seperately under relevant schedule).
Fuel flexible pipe, 1, 1/4 to 3/8 " PVC best quality complete and directed by Engr-in-Charge.
Indicating Lamp suitable for DG set complete and directed by Engr-in-Charge.
Battery terminal heavy duty of brass complete and directed by Engr-in-Charge.
Multi stranded copper condutor PVC insulated 16 Sqmmsingle core heavy duty upto 1.5 m length complete and directed by Engr-in-Charge.
Alternator Fan belt set 200/320 KVA DG set complete and directed by Engr-in-Charge. Make: Ashok Layland/Crompton Greaves/Kirloskar/Mahindra
Alternator Fan belt set 15 to 63 KVA complete and directed by Engr-in-Charge. Make: Ashok Layland/Crompton Greaves/Kirloskar/Mahindra
Oil pressure gauge for 125 to 320 KVA DG set of existing make complete and directed by Engr-in-Charge.
Oil pressure gauge for 5 to 63 KVA DG set of existing make complete and directed by Engr-in-Charge.
Oil temperature gauge for 125 to 320 KVA DG set of existing make complete and directed by Engr-in-Charge.
Oil temperature gauge for 63 to 5 KVA DG set of existing make complete and directed by Engr-in-Charge.
Water temp gauge with senser for 125 to 320 KVA DG set of existing make complete and directed by Engr-in-Charge.
Water temp gauge with senser for 63 to 5 KVA DG set of existing make complete and directed by Engr-in-Charge.
Solenoid Valve for 125 to 300 KVA DG Set cap complete and directed by Engr-in-Charge.
Solenoid Valve for 63 to 5 KVA DG Set cap complete and directed by Engr-in-Charge.
AVR for 125 to 300 KVA DG Set cap complete and directed by Engr-in-Charge.
AVR for 63 to 5 KVA DG Set cap complete and directed by Engr-in-Charge.
Self starter 12 volts complete and directed by Engr-in-Charge. Make:Lucas/ Tvs or Equivalent make.
Self starter 24 volts Make:Lucas or Equivalent make complete and directed by Engr-in-Charge.
Engine Start/stop valve for any cap DG set of existing make complete and directed by Engr-in-Charge.
Starting ignition switch for any cap DG set of existing make complete and directed by Engr-in-Charge.
M&L for servicing, cleaning and descaling of radiator assembly by using suitable chemical (MAC solution) and by blower fan and by injecting water in high pressure in water tubings so as to remove all dirts etc in the fins and soldering of puncture tubes to stop leakage and testing of DG Set of 5 to 320 kVA capacity mentioned below here in after as required at site and directed by Engr-in-Charge.
M & L for removing existing old rusted paint on DG set of painted surface and applying with two coats of synthetic enamel spray paint to match with existing colour good finish and printing of MES No., SrNo. of following capaity complete all as specified and directed.
All as per item No. 30 but for 320 KVA DG set.
All as per item No. 30 but for 160 KVA DG set.
All as per item No. 30 but for 63/40/30 KVA DG set.
All as per item No. 30 but for 15 KVA DG set.
M& L for servicing, repair, calibration and testing of fuel injector assembly incl replacement of barrels plungers cups injector and commissioning the same as required at site of DG Set of following capacity mentioned below here in after complete all as specified and directed by Engr-in-Charge.
All as per item No. 35 but for 125 to 320 KVA DG Set.
All as per item No. 35 but for 5 to 63 KVA DG Set.
M&L for servicing ,repair and overhauling of self starter 12/24 V DC complete replacement of worn out fields , armature, solenoid and bendex pinion along with carbon brushes etc of DG Set of following capacity mentioned below here in after complete in all respect all as directed.
All as per item No. 38 but for 125 to 320 KVA DG Set.
All as per item No. 38 but for 5 to 63 KVA DG Set.
Supply and fixing in repair muffler (exhaust silencer) of existing specification suitable for DG Set of following capacity mentioned below here in after complete all as specified and directed by engineer in charge.
All as per item No. 41 but for 125 to 320 KVA DG Set.
All as per item No. 41 but for 5 to 63 KVA DG Set.
M&L for servicing ,repair and charging of battery 12 V DC complete checking of battery and lead connection,tightening of clamping bolts including washing of corroded terminals with ammonia soluation consist of 115 gms of backing soda ensuring cleaning soluation does not enter into vent holes and apply petroleum jelly on terminals including electrolyte solution level high enough to touch top edge of lead plates having specific gravity of 1.28 kg/l complete in all respect all as directed by Engg-in-Charge.
M&L for draining out old engine oil from DG Sets and supply and refilling 15W 30 new engine oil to DG Sets complete all as specified and directed by engineer in charge
M&L for draining out old coolant from DG Sets and supply and refilling DAFC 30% new coolant to DG Sets complete all as specified and directed by engineer in charge
Supply only disttiled water for Battery of DG sets complete all as specified and directed by Engr-in-charge.
Supply and replacement of lead acid battery 12 volt 180 AH DC fully charged condition complete all as specified and directed by Engr-in-charge.
Supply and replacement of lead acid battery 12 volt 150 AH DC fully charged condition complete all as specified and directed by Engr-in-charge.
Supply and replacement of lead acid battery 12 volt 100 AH DC fully charged condition complete all as specified and directed by Engr-in-charge.
Supply and replacement of lead acid battery 12 volt 80 AH DC fully charged condition complete all as specified and directed by Engr-in-charge.
Material and labour for Maintenance of DG Set panel and cleaning of dust inside with blower, cleaning of moving part /contacts from CT cleaner, tightening of loose parts /electrical wires, cleaning of contactors, relays and junction points, servicing/ adjustment of relay, complete testing of AMF relay with necessary settings and load management system complete with replacement of worn out unserviceable components /burnt wires thimbles /lugs complete tested For DG set up to 320 KVA complete all as specified and directed. Note :- Parts /components for replacement shall be measured and paid seperately.
Microprocessor based AMF Module incorporating controller of supply and restoring timer 3 impulse automatic engine start /stop/ logic & fails to start locknut Mains/generator voltage, frequency sensing complete all as specified and directed by engineer in charge
Contactor 4 pole suitable for 125 KVA DG set as per existing complete all as specified and directed by engineer in charge
Contactor 4 pole suitable for 200 KVA DG set as per existing complete all as specified and directed by engineer in charge
Contactor 4 pole suitable for upto 40 KVA DG set as per existing complete all as specified and directed by engineer in charge
Battary charger in AMF Panel complete all as specified and directed by engineer in charge
Repair & Maintenance of existing canopy of eco friendly DG Set above cleaning of internal & external parts, tightening of loose parts, replacing of unserviceable door locks and keys, replacing of damaged or burned inside sponge insulations, welding of rusting parts complete all as specified and directed.
M&L for providing earthing complete with galvanised steel earth plate electrode 60 x 60cm x 6.0mm thick buried dirictly in ground (Earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level,connected to and including galvanised earth strip 32 X 6mm mm size upto 7.5 meter long by means of bolts,nuts check nuts and washers of all galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-1 and connected to test point including GI pipe medium grade 40mm dia for protection of earth lead, necessary excavation/ earth work in any type of soil/rock strata,funnel with wire mesh and watering pipe(GI,light grade) 20mm dia,PCC pit with 50mm thick PCC cover etc. including testing complete all as directed by Engineer-in-Charge.
Supply and fixing ON LOAD Change over switches ( outdoor type), 4 pole 415 volts of capacity 63 Amps complete taking down old unserviceable and making necessary connections including all provisions for fixing in panel compartments as existing using necessary links of suitable metals and cleaning the terminals with CTC solutions complete all as specified and directed by Engr-In-Charge .
All as per Ser Item No 60 but 160 Amps rating
All as per Ser Item No 60 but 200 Amps rating
All as per Ser Item No 60 but 400 Amps rating
All as per Ser Item No 60 but 630 Amps rating
Supply and fixing MCCB TPN/TP 415 Volts of rating 250 Amps of braking capacity 36 KA of 4 pole confirming to (Adjustable Thermal and Magnetic Release Setting with short circuit settings) complete taking down old unserviceable one and making necessary connections including all provisions for fixing in panel compartments as existing using necessary links of suitable metals and cleaning the terminals with CTC solutions complete all as specified and directed. Make : Havells/Legrand/IndoAsian (optium 2.0)/Schneider/HPL/Standard
All as per item No.65 above but of rating 200 Amps with braking capacity 25 KA. Make : Havells/Legrand
All as per item No.65 above but of rating 100 Amps with braking capacity 25 KA. Make : Havells/Legrand
All as per item No.65 above but of rating 63 Amps with braking capacity 16 KA. Make : Havells/Legrand
SHRI SHYAM CONSTRUCTION CO.
HARSH CONSTRUCTION CO.
PUNEET ENTERPRISES
P.K ENTERPRISES
TARA ENTERPRISES
DASHMESH ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .