Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC 5B FF NAND VIHAR AZAD NAGAR NEAR GODARA PETROL PUMP HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹38.5 L+₹12.6 L (48.9%)Rejected-Finance | L2 | Rejected-Finance HIGHER | |
| 3 | L3₹41.7 L+₹15.8 L (61.2%)Rejected-Finance | L3 | Rejected-Finance HIGHER | |
| 4 | L4₹41.9 L+₹16.0 L (61.9%)Rejected-Finance | L4 | Rejected-Finance HIGHER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
10 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Amritsar
GE Amritsar pin 143001
REPAIR/MAINTENANCE OF DBs, METER BOXES, SUBMAIN WIRINGS AND OTHER FITTINGS AND FIXTURE AT MAP ACCN UNDER GARRISON ENGINEER AMRITSAR CANTT
2024_MES_653738_1
GE/ASR-36/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE Amritsar
class D category b i
8 documents required · 8 mandatory
₹500
GE Amritsar
₹90,000
22 Sept 2024
14 May 2024
11 Jun 2024
14 May 2024
10 Jun 2024
28 May 2024
Amount
Material and Labour for repairs to meter panel board by disconnecting electrically and changing of MCCB/MCB SPN/Meters etc. complete including connecting of earth wires properly, terminating LT Cables in MCCBs, tightening of electric connections including replaement of meter panel door as per existing where ever required as directed by Engr-in-Charge with suitable fixing arrangements, painting of meter panel board with two coats of synthetic enamelled paint over a coat of red oxide primer & writing down Qtr No. on respective meters, replacement of broken viewing glass as site requirement ; Complete all as specified and directed by Engineer-in-Charge. NOTE: The items requires for replacement, if any will be measured and paid seperately as supply only under ser item No. 02 to 04 here-in-after
Supply only MCCB triple pole and neutral (four pole) 100 Amps, 415 volts, 50 Hz, having thermal setting range 70% to 100% and adjustable magnetic setting and breaking capacity 16 KA including making incoming and outgoing connections ; Complete all as specified and directed by Engineer-in-Charge.
Supply only MCCB triple pole and neutral (four pole) 63 Amps, 415 volts, 50 Hz, having thermal setting range 70% to 100% and adjustable magnetic setting and breaking capacity 16 KA including making incoming and outgoing connections ; Complete all as specified and directed by Engineer-in-Charge.
Supply only MCB of SPN 32 Amps current carrying capacity, 240 V, 10KA 'C' curve fixed in the MCB DB complete with connection testing & commissioning ; Complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in repairs meter panel box door made out of MS plain black sheet of 1.60mm thick CRCA, cut to existing size or directed by Engr-in-Charge, including necessary fixing arrangement such as round headed screws, clout nails or riveting, welding and fixed and steel framing of required size with suitable plain lap joints with riveted or welded seams, bending or turning up, mitred angles, etc.,including painting of meter panel board with two coats of synthetic enamelled paint over a coat of red oxide primer ; Complete all as specified and directed by Engineer-in-Charge.
Material and Labour for sub main wiring with 1100 volt grade two single core FRLS Wire PVC insulated and unsheathed cable with stranded copper conductor 6.0 sqmm drawn into and including electrical grade PVC conduit not less than 25 mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 6.0 sqmm multi - stranded copper conductor as earth wire in green colour ; Complete all as specified and directed by Engineer-in-Charge. including taking down old unserviceable sub main wiring. NOTE: Two runs of 6.0 sqmm PVC FRLS multi stranded copper cable wire and One run of 6.0 sqmm PVC FRLS multi stranded copper cable earth wire and One run (01 meter) PVC conduit of suitable size ISI mark will be measured and one unit length.
Material and Labour for IR test of internal wiring complete with polarity test as ; Complete all as specified and directed by Engineer-in-Charge.
Material and Labour for checking & earthing resistance with earth tester 100 volts with spikes & wires ; Complete all as specified and directed by Engineer-in-Charge.
Supply and Laying in trenches/drawn through pipes or in road crossings/paths/drains/ ducts/floors/along poles/equipments etc., of LT cable under ground, heavy duty, armoured, XLPE insulated with multi-stranded aluminium conductor cable conforming to IS-7098 Part-I (1998), 1100 Volts grade of 25 Sqmm 4 core nominal cross sectional area including necessary double compression copper gland and connecting up using suitable size aluminium lugs testing, including taking down old Unserviceable one from site ; Complete all as specified and directed by Engineer-in-Charge. NOTE: Excavation & earthwork will be measured and paid separately
Excavating in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation for erection of poles, stays, laying cables, stays etc and getting out in soft/loose soil and in road cutting ; Complete all as specified and directed by Engineer-in-Charge.
Returning, filling in excavated material/soil including spreading, leveling, watering and well ramming in layers n exc 25cm in soil ; Complete all as specified and directed by Engineer-in-Charge.
Removing excavated material/surplus soil not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meter above starting point ; Complete all as specified and directed by Engineer-in-Charge.
Supply & laying double wall corrugated (DWC) high density poly ethylene (HDPE) of size 63mm outer dia & 50mm inner dia including all necessary fittings, PN-4 rating, pressure 6 Kgf/cm², conforming to IS-16205 (Part-24) with high ring stiffness & cursh resistance capacity, etc., laid in trench for protection of submersible flat cable ; Complete all as specified and directed by Engineer-in-Charge.
Material and Labour for sub main wiring with 1100 volt grade two single core FRLS Wire PVC insulated and unsheathed cable with stranded copper conductor 6.0 sqmm drawn through existing surface/recessed steel/rigid PVC concealed conduit including 6.0 sqmm multi - stranded copper conductor as earth wire in green colour complete all as specified and directed. including taking down old unserviceable sub main wiring from site ; Complete all as specified and directed by Engineer-in-Charge. NOTE: Two runs of 6.0 sqmm PVC FRLS multi stranded copper cable wire and One run of 6.0 sqmm PVC FRLS multi stranded copper cable earth wire will be measured and one unit length.
Material & Labour in repairs for earthing complete with galvanised earth plate electrode 600mm X 600mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 metres below ground level) with top edge of earth plate not less than 1.5metres below normal ground level, connected to GI Wire of size 4mm dia by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No.3 of MES SSR 2009, Part – I (Specifications) and connected to main switch board/LT feeder panel including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in alternate layers with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel round bars @ 150mm both ways center to center with suitable lifting handle to cover, earth pit made of PCC 1:3:6 type C-1, GI protection pipe light grade 20 mm bore up to 7.5metres length from earth electrode including testing ; Complete all as specified and directed by Engineer-in-Charge. NOTE: (i) Earth lead and protection pipe beyond 7.5 m shall be measured and Paid separately. (ii) On testing after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt. (iii) Rate quoted shall be includingusive of excavation and earth work and PCC all as specified in the item (iv) Earthing work will be carried out in the presence of MES representative
Material and Labour for distribution board, vertical, made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, VTPN 4 way, 415 volts grade with insulated rated bus bar assembly with isolated neutral bar,door earthing, earth bar IP- 43 protection with poly urithene (PU) gasketing, IK-08 Mechanical impact resistance, door earthing flush to wall, including testing suitable for fixing MCCB, MCB TPN/TP/SPN/SP etc, including dismantling of old Unserviceable one of any type/size from site and making good to disturbe surface wall ; Complete all as specified and directed by Engineer-in-Charge. NOTE FOR SER NO. 02 TO 04 & 16 TO 22: MCB DB & MCBs should be of same make.
Supply and Fixing MCCB triple pole and neutral (four pole) 100 Amps, 415 volts, 50 Hz, having thermal setting range 70% to 100% and adjustable magnetic setting and breaking capacity 16 KA including making incoming and outgoing connections ; Complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing MCCB triple pole and neutral (four pole) 63 Amps, 415 volts, 50 Hz, having thermal setting range 70% to 100% and adjustable magnetic setting and breaking capacity 16 KA including making incoming and outgoing connections ; Complete all as specified and directed by Engineer-in-Charge.
Material and Labour for distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, SPN 12 way, 240 volts grade with 200 Amps insulated rated bus bar with nickel plated brass, isolated neutral bar and door earthing, earth bar IP- 43 protection with poly urithene (PU) gasketing, IK-08 Mechanical impact resistance, flush to wall, including testing suitable for fixing MCB SPN, SP etc, including dismantling of old Unserviceable one of any size/type from site and making good to disturbe surface wall ; Complete all as specified and directed by Engineer-in-Charge. NOTE: Necessary blank plates if required any to cover the blank MCB's place in DB and the rate shall be deemed to includinguded in the quoted rates.
Material and Labour for distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, SPN 08 way, 240 volts grade with 200 Amps insulated rated bus bar with nickel plated brass, isolated neutral bar and door earthing, earth bar IP- 43 protection with poly urithene (PU) gasketing, IK-08 Mechanical impact resistance, flush to wall, including testing suitable for fixing MCB SPN, SP etc, including dismantling of old Unserviceable one of any size/type from site and making good to disturbe surface wall ; Complete all as specified and directed by Engineer-in-Charge. NOTE: Necessary blank plates if required any to cover the blank MCB's place in DB and the rate shall be deemed to includinguded in the quoted rates.
Supply and Fixing MCB of SP 5 to 32 Amps current carrying capacity, 240 V, 10KA 'C' curve fixed in the MCB DB complete with connection testing & commissioning ; Complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing MCB SPN 32 Amps current carrying capacity, 415 V, 10KA 'C' curve fixed in the MCB DB complete with connection testing & commissioning ; Complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing switch socket combination 2 in 1, 3 pin, 5 and 15 Amp, 240 volts flush type universal including taking down old Unserviceable one from site ; Complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing Wall mounted, indoor, HELIOS Mirror Light LED with aluminium die cast, suitable for and including 10 watt 6000K, WH LED light, prewired with 3 core flexible copper cable (1.0 mm² size/core) from connector to light fittings and connecting up including taking down old Unserviceable one from site ; Complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing LED lights fitting 1x 20W, 220V, AC, 5700K, decorative box type with driver, double sided connection, CRI> 80, PF>95%, THD<10%, Lumen>2100 lm including LED tube light connecting up with 3 core flexible copper conductor cable (1.0 mm² size/core) from ceiling rose including taking down old Unserviceable one from site ; Complete all as specified and directed by Engineer-in-Charge.
Bharatbuilder
innovative associates
PAWAN KUMAR GOVT. CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .