Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 LAccepted-AOC NO 10 CHINNASWAMI NAGAR ASHOK NAGAR NEAR OLD RAILWAY STATION KANCHIPURAM TAMILNADU 631502 | KANCHIPURAM | TAMIL NADU | 631502 | L1 | Accepted-AOC Single bidder |
Tender Value
₹2.8 L
EMD Value
₹5,576
Closing Date
28 Nov 2024, 9:30 amClosed
The Executive Engineer, PWD Mahe
Public Works Department, Mahe. Near Sub Court, Mahe
Replacement of the damaged LT UG cable extending power supply to the street light posts and the damaged fittings along the IKK master road from stadium road junction upto Railway Station, Mahe, Puducherry.
2024_PWDC2_16935_1
29/EEM/24-25/20(24-25)
Open Tender
Electrical Works
Item Rate
30 days
Work at Mahe
Please refer Tender documents.
3 documents required · 3 mandatory
₹525
₹5,576
21 Jan 2025
22 Nov 2024
28 Nov 2024
22 Nov 2024
28 Nov 2024
22 Nov 2024
Amount
Code No. Non PSR:- Supply and fixing of LED flood light luminaries 200W (Power output), suitable for street light bracket/ high mast bracket, white light with pressing die cast aluminium, Diffuser clear toughen glass housing IP 65/66, efficacy> 110Lm/Watt, LED chip package 5050, CRI> 70, rated voltage: 240V, rated frequency 50HZ safe operating voltage range 140V-280V AC and with necessary over voltage, short circuit open circuit & surge protection. The luminaries shall be warranted for three years on site replacement /rectification. The NABL type test report, Driver safety test report as per BIS, LM80 report from chip manufacturer shall be furnished. (Make:- Philips/Havells/Crompton / Everyday /Bajaj).The rate is inclusive of all taxes. (APP. Rate. Vide Lr. No. 2343/ PW /SE.II/ AE(P)- 6/SB-150/2019-20/990, dt.20/08/19)
Code No. 17.1.15:- Checking and rectifying the fault in the street light fittings
Code No. 17.2.11:- Fixing testing and commissioning of Sodium vapour / Mercury vapour / Metal halide street light fittings on existing poles as required
Code No. 17.17:- Checking and rectifying the fault in the control panel of per highmast / street light / traffic island park illumination
Code No. 17.1.9:- Replacement of timer switches of control panel of highmast / per median light / traffic island park illumination Make: L&THagger / Legrand - Lexic
Code No. 17.1.10:- Replacement of power contactor of control panel of highmast / per median light / traffic island park illumination Make: Siemens / L&T
Code No. 2.10.5:-Supplying and fixing 5 A to 32 A rating , 240/415 V, 10 kA, "C" curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc .as required. - Triple pole and neutral
Code No. Non PSR:- Supply of 2.5 sq.mm x 3 core PVC sheathed multicore flexible copper cable. Make:- Finolex/ Polycab/ Power- flex/Havells. (Inclusive of GST) (Approved by SE-III vide Lr.No. 05/ PW / SE-III/kkl/JE5/2022-23, dt. 12.04.2022)
Code No. Non PSR:- Supply of ISI marked 4 x 16 sqmm armoured aluminium PVC U.G. cable - 1.1 KV grade. Make:- Finolex / Polycab/ Havells. (Inclusive of GST )(Rate App. Lr.No.05 /PW/SE-III/ KKL/ JE5/2022-
Code No. 7.1.1:- Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc.as required - Upto 35 sq.mm
Code No. 9.1.20:- Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 31/2 X25 sq.mm (28 mm)
Code No. Non PSR:- Supply & Laying of Potential Earth Electrodes Model STANDARD PS53C 48mm dia, wall thickness 3.25mm, terminal size:32 x 10 mm, terminal hole dia 12 mm, hot dip galvanized 80 to 100 microns, 3 meler long, pipte inner space filled with high conductive material, including 2 bags (25kg per bag) of Earth Life Compound, as IS 3043. Base Metal IS marked branded mild steel pipes. (App No. 235/ PW/SE-I/AE(P)/ F.No. CB-312/2015-16, dated 06.10.15.
Code No. 5.13:- Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I.pipe from earth electrode including connection with copper thimble excavation and re-filling as required
Code No. 3381:- Hire charges for ladder vechicle
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .