| 1 | L1₹19.1 LAccepted-AOC FLAT NO 4 C GH 39 MANSA DEVI COMPLEX SECTOR 05 PANCHKULA 134 109 HRY | PANCHKULA | PANCHKULA | HARYANA | 134109 | ₹19.1 L Quoted ₹19.6 L | L1 | Accepted-AOC The lowest bidder |
| 2 | L2₹22.3 L+₹2.7 L (13.9%)Rejected-AOC | ₹22.3 L+₹2.7 L (13.9%) | L2 | Rejected-AOC Other than the lowest bidder |
| 3 | L3₹23.0 L+₹3.4 L (17.4%)Rejected-AOC 546 14 JUTOGH CANTT SHIMLA HP 171008 | SHIMLA | HIMACHAL PRADESH | 171008 | ₹23.0 L+₹3.4 L (17.4%) | L3 | Rejected-AOC Other than the lowest bidder |
| 4 | L4₹25.7 L+₹6.1 L (31.0%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹25.7 L+₹6.1 L (31.0%) | L4 | Rejected-AOC Other than the lowest bidder |
| 5 | L5₹26.3 L+₹6.7 L (34.0%)Rejected-AOC BOOTH NO 119 SECTOR 9 PANCHKULA 134109 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134109 | ₹26.3 L+₹6.7 L (34.0%) | L5 | Rejected-AOC Other than the lowest bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
30 Sept 2021, 6:00 pmClosed
GE JUTOGH
GE JUTOGH, JUTOGH CANTT SHIMLA (HP) - 171008
REPAIR AND MAINTENANCE OF OVER HEAD LINES, UG CABLE, ELECTRIC POLES, LT PANEL, DISTRIBUTION PANEL AND LT SWITCHGEARS AT JUTOGH, SANJAULI, KUFRI AND KELVIN GROVE UNDER GE JUTOGH
2021_MES_472367_1
GE/JUT-37 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
JUTOGH
CLASS D CATEGORY b (i)
7 documents required · 7 mandatory
₹500
GE JUTOGH
₹60,000
Yes
9 Nov 2021
2 Sept 2021
2 Oct 2021
2 Sept 2021
30 Sept 2021
16 Sept 2021
Amount
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose/soft soil and getting out for underground cable/erection of poles, stays , trench etc complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and directed.
Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified and directed.
M&L in replacement for shackle type porcelain vitreous white or brown insulator including Galvanised steel straps, washers, insulator bolts and nuts for working pressure 1100 volts, 75 mm height, 90 mm dia, section of strap 31mmx3mm & dia of bolt 12 mm complete all as specified and directed.
M&L in replacement for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 10 sqmm 2 core complete all as specified and directed.
M&L for earthing complete with galvanized steel earth electrode plate of size 60x60x6mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less then 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to GI earth lead strip of size 25X4.0 mm at two points by means of GI nuts bolts, check nuts and washers and connected to earthling test point drawn through 40 mm dia GI pipe for protection pipe incl PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part-I including testing and dismantling ,taking down old unser earthing complete all as specified and directed. Note: (i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead upto 7.5 mtr, char coal dust, common salt, porcelain insulator,PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh are incl in quoted rate and watering pipe, earth lead protection pipe, test poit, and earth lead exceeding 7.5 mtr are measured and paid separately.
M&L for earthing complete with galvanized steel plate earth electrode 60cmx60cmx6mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less then 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to galvanised earth lead wire of 4.0mm dia at two points by means of GI nuts bolts, check nuts and washers and connected to earthling test point drawn through GI pipe for protection of earth lead wire incl PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part-I including testing and dismantling ,taking down old unser earthing complete all as specified and directed. Note: (i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead upto 7.5 mtr, char coal dust, common salt, porcelain insulator, PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh are incl in quoted rate and watering pipe, earth lead protection pipe, test poit, earth lead exceeding 7.5 mt are measured and paid separately.
Supply , Fixing & laying GI tubing light grade 15 mm dia used as water pipe or protection pipe in earthing complete all as directed. Note: All required items and accessories , bend, joints, nut bolts, clamps etc are incl in quoted rates complete all as specified and directed.
Supply, Fixing & laying GI tubing light grade 20 mm dia used aswater pipe or protection pipe for earth lead wire in earthing or alongwith pole / wall/ culvert / drainage etc for mechanical protection of cable complete all as specified and directed. Note: All required items and accessories , bend, joints, nut bolts, clamps etc are incl in quoted rates.
Supply , Fixing & laying GI tubing light grade 40 mm dia used as protection pipe for earth lead strip in earthing or alongwith pole / wall/ culvert / drainage etc for mechanical protection of cable complete all as specified and directed. Note: All required items and accessories , bend, joints, nut bolts, clamps etc are incl in quoted rates.
Supply , Fixing & laying GI tubing light grade 80 mm dia for road crossing along with pole/culvert /drainage for mechanical protection of cable complete all as specified and directed. Note: All items and accessories , bend, joints, nut bolts, clamps etc are incl in quoted rates.
Supply & fixing or laying in replacement HDPE (DWC) tubing outer dia not less than 50 mm fixing on poles, walls under floors, laying on surface etc as reqd at site complete all as specified and directed. Note: (i)The rates of required accessories, bend, joints etc are deemed to be included in quoted rates . (ii) The rate of clamps, nut-bolts and any other MS items for fixing on wall/surface are measured and paid separately under relevent item.
Disconnecting & taking out defective underground cable any size and any type from trenches, pole, pipe, floor, wall etc complete all as specified and directed.
Supply and laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 35 sqmm 3.5 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc. Note: (i) Earth work, removing, returning filling and pipe will be measured and paid separately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates. (iii) All equipments , machinery or tools if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost complete all as specified and directed.
All as per Srl Item No 14.00 above butfor 3.5 core 50 Sqmm complete all as specified and directed.
All as per Srl Item No 14.00 above butfor 3.5 core 70 Sqmm complete all as specified and directed.
All as per Srl Item No 14.00 above butfor 3.5 core 95 Sqmm complete all as specified and directed.
All as per Srl Item No 14.00 above butfor 3.5 core 120 Sqmm complete all as specified and directed.
All as per Srl Item No 14.00 above butfor 3.5 core 150 Sqmm complete all as specified and directed.
All as per Srl Item No 14.00 above butfor 3.5 core 185 Sqmm complete all as specified and directed.
All as per Srl Item No 14.00 above butfor 3.5 core 240 Sqmm complete all as specified and directed.
All as per Srl Item No 14.00 above butfor 3.5 core 300 Sqmm complete all as specified and directed.
All as per Srl Item No 14.00 above butfor 3.5 core 625/630 Sqmm complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for cement concrete (unreinforced) or road cutting complete all as specified and directed.
M&L cement concrete 1:2:4 type B-0 (using 12.5.0 mm graded crushed stone aggregate) as in filling demolished surface or as leveling course or in foundation or under tiles or in any required work and make surface clear complete all as specified and directed.
M & L in replacement cross arms, bracings, supports, clamps and back plates fabricated from structural steel section incl nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primercoat, one under coat and one finishing coat of paint. incl dismantling and taking down old unsv complete all as specified and directed.
S&F in replacement MCCB 400 Amps, 36 KA 4 pole 415 Volts AC, adjustable overload setting , adjustable short circuit setting with double break contacts with spreader and phase barrier complete all as specified and directed.
S&F in replacement MCCB TPN 250 Amps , 415 Volts, 35/36 KA ,4 POLE, overload adjustable short circuit adjustable type incl complete connection complete all as specified and directed.
S&F in replacement MCCB TPN 160 Amps , 415 Volts, 25 KA ,4 POLE, overload adjustable short circuit fixed type incl complete connection complete all as specified and directed.
S&F in replacement MCCB TPN 100 Amps , 415 Volts, 16/18 KA ,4 POLE, overload adjustable short circuit fixed type incl complete connection complete all as specified and directed.
Disconnecting & taking out defective underground cable from trenches, pole, pipe, floor, wall etc and locate the fault manualy, rectify the defect and relaying cable including connecting and testing for any size complete all as specified and directed. Note: Excavation/earth work, joint and any other item shall be measured & paid separately under relevent item.
S&F straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5/4 C x 25-50 Sqmm complete all as specified and directed. Note: Earth work will be measured and paid separately.
S&F straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 C x 70-150 Sqmm complete all as specified and directed. Note: Earth work will be measured and paid separately.
S&F straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 Cx 185-400 Sqmm complete all as specified and directed. Note: Earth work will be measured and paid separately.
Supply, fixing or laying in replacement HDPE (DWC) tubing outer dia not less than 90 mm fixing on poles, walls under floors, laying on surface etc complete all as specified and directed. Note: (i) The rates of required accessories, bend, joints etc are deemed to be included in quoted rates . (ii) The rate of clamps, nut-bolts and any other MS items for fixing on wall/surface are measured and paid separately under relevent item.
Re-stretching existing/retrieved ACSR conductor on LT pole and binding conductor on insulator properly using new binding wire/jumper wire complete all as specified and directed. Note : (i) Each Run of line conductor shall be measured & paid for separately. (ii) Insulators if required are measured and paid separately.
S&F Busbar Chamber of size not less than 0.4m x 0.4m x 0.3m with set of 04 aluminium busbar 200 Amps rating each fixed on suitable insulators with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. Bus bar chamber will be fixed on 04 nos of legs made with MS Angle. Length of each leg will be not less than 0.6m. The Chamber shall be fixed more than 30 cm above the normal ground level complete with PCC foundation (1:2:4 ) type B2 complete all as specified and directed.
S&F changeover switches 4 pole 400 Amps , 415 volts in sheet metal enclosure incl fixing on wall/LT panel/any other surface using nut/bolts/Anchor fastners and dismantling and taking down old unser switch/MCB/MCCB/DB as available on site any type any size complete all as specified and directed.
S&F changeover switches 4 pole 200 Amps , 415 volts in sheet metal enclosure incl fixing on wall/LT panel/any other surface using nut/bolts/Anchor fastners and dismantling and taking down old unser switch/MCB/MCCB/DB as available on site any type any size complete all as specified and directed.
S&F changeover switches 4 pole 160 Amps , 415 volts in sheet metal enclosure incl fixing on wall/LT panel/any other surface using nut/bolts/Anchor fastners and dismantling and taking down old unser switch/MCB/MCCB/DB as available on site any type any size complete all as specified and directed.
Supply, installation, testing and commissioning outdoor type cubical LT panel board of size not less than 1.2 mX 1.0 m x .6 M outer shell made out of 3.15 and inner shell made out of 2.0 mm thick MS sheet and MS angle section 50 x 50 x 6mm on PCC 1:2:4 type B-1 platform 60cm above the ground level and 45cm below the ground level, factory fabricated with front and back openable double door system (each door hinged with body at 4 places) lockable, openable by keys, having pad lock arrangement with both side, with pad lock of three keys 2 nos. olouvers and air vent, gasket ‘u’ type for natural flow of air, completed dust & vermin proof suitable for 3 phase 4 wire 415 volt 50 Hz factor fabricated ( Factory approved from CPRI) having modern fabrication followed by power coated painting having thickness not less than 100 microns TPN aluminum bus bar 600 Amps insulated with colour coded heat shrinkable and shall be mounted on suitable size ‘F’ class insulators, marking connection with aluminum strip conductor of and general construction to IS-8623 of 1993 comprising of the following:-
Onload change over switch 400 Amps 4 Pole - 01
MCCB 400 Amps, 36 KA 4 pole 415 Volts AC, adjustable overload and fixed short circuit (incoming)-01 No
MCCB 125 Amps, 16 KA 4 pole 415 Volts AC, overload adjustable and fixed short circuit (Outgoing), -06 Nos.
RYB indication LED type, 22.5mm dia, 230 volts protected with MCB SP 2 Amp showing 3 phase supply -03 Nos
Misc items like screws, cable tie, copper cable 1.5/ 2.5 Sqmm, cabe lugs, sleeves etc complete
Note (i) The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming to IS-694. (iii) Panel drawing shall be got approved before placing of order from Engr-in-Charge/GE. (iv) The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated.
KATWAL TECHNOCRATS
M/S kuldeep kumar khullar
R D Bansal
SHARMA ELECTRICAL ENGINEERS
Rajesh Agencies
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .