Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 CrAccepted-AOC | ₹13.1 Cr Quoted ₹13.6 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹13.9 CrRejected-AOC | ₹13.9 Cr | L2 | Rejected-AOC Rejected |
| 3 | Rejected-Technical | - | - | Rejected-Technical Rejected |
Tender Value
Refer Docs
EMD Value
₹6.7 L
Closing Date
26 Sept 2024, 3:00 pmClosed
superintending Engineer
Office of the Superintending Engineer PWD Buildings Construction and Maintenance Circle, Tirunelveli
CONSTRUCTION OF COMMERCIAL TAX OFFICE BUILDING AT TIRUNELVELI IN TIRUNELVELI DISTRICT.
2024_PWD_477797_1
7(3)SE/2024-25 dated.20.08.2024
Open Tender
Civil Works - Buildings
540 days
Tirunelveli
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹6.7 L
14 Feb 2025
28 Aug 2024
27 Sept 2024
28 Aug 2024
26 Sept 2024
28 Aug 2024
Amount
Dismantling clearing away and carefully stacking materials useful for reuse of the following items: Any thickness of: (TNBP No.18)
Dismantling RCC by manual/by using depolying machineries
Brick / stone masonry in Cement mortar walls under 3m high
Dismatling Doors & windows including removal of frames, hinges and fastenings
Earth work excavation for foundation in all soils and sub soil and to full depth as may be directed except in hard rock requiring blasting but including shoring, strutting and balling out water wherever necessary and refilling the sides of foundation with excavated earth in layers of not more than 15cm thick well rammed consolidated and depositing the surplus earth within the compound with an initial lead of 10 metres and lift of 2 metres in places shown by the departmental officers clearing, leveling the site etc., complete complying with standard specification.
Earth work open excavation in all soils and sub soil and to full depth as may be directed except in hard rock requiring blasting but including shoring, strutting and balling out water wherever necessary and depositing the surplus earth within the compound with an initial lead of 10 metres and lift of 2 metres in places shown by the departmental officers clearing, leveling the site etc., complete complying with standard specification.
Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification
Supplying and filling in foundation, basement, etc with stone dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Supplying and filling with Crushed Stone(M-Sand) in layers of not more than 15 cm thick without consolidation etc. complete complying with standard specification and as directed by the departmental officers.
Cement Concrete 1:5:10 (One Cement, Five Crushed Stone Crushed Stone Sand (M-Sand) ) and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification
Pre-Construction anti-termite treatment plinth area – surface treatment stage-1 :- Completion of earth work for column footings before laying plain cement concrete 25mm dia Hole spaced at 30cm center to center on both direction will be made at the bottom of earth work and the chemical will be poured in the holes and will be sprayed in the four sides of earth work at the rate of 3 litres of chemical solution (Chlorophyrifos emulsion diluted in ratio 1:19 (One emulsion and 19 water ) per square metre payment shall be made after completion of 3 stages. stage-II :- After filling the basement before laying flooring concrete with filling Crushed stone sand(M-Sand) 25mm dia holes to adepth of 450mm will be made inside the basement and the chemical will be poured in the holes at the rate of 3 litres of chemical solution (Chlorophyrifos emulsion diluted in ratio 1:19 (One emulsion and 19 water ) per square metre payment shall be made after completion of 3 stages.
Peripheral treatment stage-III.On completion of building and leveling the outer area adjacent to the walls column ground ponds of size (900X300 mm will be filled in the ponds at the rate of 3 litre of chemical solution per Rm payment shall be made after completion of 3 stages. Stage-IV.Spraying termite solution around the building (Out side of the building) by making crowbar holes around the building before laying the plinth protection. This holes has to be closed after the treatment
Brick work in Cement Mortar 1:5 ( one Cement and five Crushed Stone(M-Sand))using best quality of country bricks of size 8-3/4" x 4-1/4" x 2-3/4" for foundation and basement including curing, etc., complete complying with standard specification.
In Foundation & Basement
In Ground Floor
Brick work in Cement Mortar 1:6 ( one Cement and six Crushed Stone(M-Sand))using best quality of country bricks of size 8-3/4" x 4-1/4" x 2-3/4" for foundation and basement including curing, etc., complete complying with standard specification.
In Ground Floor
In First Floor
In Second floor
In Third floor
In Fourth floor
in Fifth floor
Brick partition walls of 10.80cm thick using best quality of country bricks of size 8-3/4" x 4-1/4" x 2-3/4" in Cement Mortar 1:3 (One Cement and Three Crushed Stone(M-Sand)) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
In Ground Floor
In First Floor
In Second floor
In Third floor
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)
For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc.
Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part there of but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers.
Providing and laying in position, standardised concrete Mix M-25 Grade in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kg/m3 and maximum water cement ratio of 0.50, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.)
about (4.79 cu'm') 7670 kg. of M-Sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).
In Foundation & Basement
In Ground Floor
In First Floor
In Second floor
In Third floor
In Fourth floor
in Fifth floor
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)
Plain Cement Concrete 1:2:4 (one cement, two sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers. For Foundation and Basement
Supplying and filling ISS metal of following size in dispersion trench including stacking for pre measurements around the stoneware pipe or in the leach pit or soak pit to the required thickness as directed by the departmental officers etc.,complete.- a) 20mm ISS metal
Supplying and filling ISS metal of following size in dispersion trench including stacking for pre measurements around the stoneware pipe or in the leach pit or soak pit to the required thickness as directed by the departmental officers etc.,complete.- a) 40mm ISS metal
Cement concrete 1:5:10 (one cement, five Crushed stone M-Sand and ten broken stone) using hard broken granite stone jelly 40mm gauge for flooring including dewatering if found necessary and laid in layers of not more than 15cm thick in the case of foundation etc. complete complying with standard specification.
Paving the floor with best quality double charged vitrified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three crushed stone sand(M-Sand)) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Flooring with Anti skid Self Designed Colour Ceramic Tiles of size 305 x 305 x 6mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three crushed stone sand(M-Sand)) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise and similar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 of 18 / 20mm with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three Crushed Stone(M-Sand)) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc Complete as Per Standard Specification., The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard specification.
Paving the floor with Cement based Hydraulically pressed Anti skid tiles (pattern design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works).
Dadooing walls with Printed design colour glazed ceramic tiles of size 300mm x 600mm x 10mm of best approved quality laid in cement mortar 1:2 (One cement and two crushed stone sand(M-Sand)) 10mm thick and pointing with white cement using 0.40 Kg of white cement in all floors per square metre including cost of tiles, all materials, incidental charges, transportation charges and labour charges for fixing tiles neat finishing the joint flush curing as directed by the Departmental Officers complete complying with standard specification. The tiles should be got appproved by the Departmental Officers before use on work.
Dadooing walls with best approved quality Jet Black granite Slab of size 1200x600 with 18mm to 20mm thick set in Cement Mortar 1:2 (One Cement and Two Crushed Stone sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.
Manufacturing, supplying and fixing in position plain cement concrete precast pavement slab of size 450mm x 450mm of 50mm thick in Cement Concrete 1:2:4 (One cement, Two sand and Four jelly) using 20mm HBG stone jelly including cost of moulding charges, casting of slab, finishing, curing, fixing and pointing the slab with CM 1:3 (One Cement and Three Sand) to full depth of slab etc., complete complying with standard specification and as directed
Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick mixed with bonding agent Cebex112, Zydex-Zycrete 2X of other Equalent compound confirming to BIS at 200ml of one cement bag (50kg) for incresed workability and air entrainment used finishing in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick mixed with bonding agent Cebex112, Zydex-Zycrete 2X of other Equalent compound confirming to BIS at 200ml of one cement bag (50kg) for incresed workability and air entrainment used finishing including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
Plastering with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 12mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement with bonding agent Cebex112, Zydex-Zycrete 2X of other Equalent compound confirming to BIS at 200ml of one cement bag (50kg) for incresed workability and air entrainment used including finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers.
Providing Polymer Coating (Water Proof Coating) for sunken Portion of toilet with following specification and the surface shall be cleaned to remove all dust, foreign, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred throughly until no bubbles remain in the mix. Any lumps found in mix shall be removed.Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete.
Supply & Fixing PVC Trims Beading etc., complete and as directed by the departmental officers.
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900 mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
Providing Double Nosing for Granite slab flooring in steps and wall top in all floors and finishing the surface neatly etc., complete complying with standard specification and as directed by the departmental officers.
Grooving the granite slab flooring in steps and wall top in all floors and finishing the surface neatly etc., complete complying with standard specification and as directed by the departmental officers.
Brick Jelly Lime Concrete 1:2:5 (one Lime,Two Crushed Stone Sand and Five brick jelly) using 20mm brick jelly in Lime Mortar 1:2 etc., complete complying with standard specification and as directed by the departmental officers.
In First Floor
In Second floor
In Third floor
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no Sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
Finishing the top of roof with one course of approved first quality machine pressed tiles of size 230 mm x 230 mm x 20 mm thick of approved quality laid in cement mortar 1:3 (one cement and three Crushed Stone Sand (M-Sand)) 12mm thick mixed with water proofing compound confirming to Indian standard specification as approved by the departmental officers at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same mortar mixed with the water proofing compound and red oxide etc. complete complying with standard specification.
Supplying and fixing in position best approved BIS quality of PVC rain water down fall pipes having a working pressure of 4 Kg./sq.cm of following dia. including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc. and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc. complete. The rate shall be inclusive of cost of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of clamps. Special type of "U" clamp at the centre of the pipe line shall be fixed in addition to those for more than 3.0 metre pipe length etc., complete complying with standard specification.
160 mm dia pipe
110 mm dia pipe
Supply and installationi of Anutone (or) Equivalent Brand of Acoustical False Ceiling of subtex nubby, square edge, glass fibre core fully encapsulated ceiling tile of size 595 x 595 x 15mm having volume density 120Kgs/m3, weight 1.8/2.4/3 kg/m2 which is suspended by using 0.3mm thick skelet trelis T15 metal grid system. Skelet trelis T15metal grid system of 600 x 600mm module includes skelet WA15 W30 wall angel with unequal flanges of 15/19mm, length 3000mm, fixed along the perimeter of walls with the help of nylon sleves and suitable fasteners at 300mm centers. Then suspend the skelet MT15 W36 Main T wtih flange width 15mm, height 32mm and length 3600mm, , from the soffit slab with help of soffit cleat and wire rod with leveling spring clip at 1200mm centres. Skelet CT15 W12 CrossT with flange width 15mm, height 26mm and length 1200mm is interlocked into the pre-cut slots in the Main T15 at 600mm centers in the perpendicular direction to the Main T15. Finally, the skelet CT15W06 CrossT with flange width 15mm, height 26mm and length 600mm are interlocked into the precut slots in the CT15W12 CrossT
in direction parallel ot the Main T15 to result in 600 x 600mm double. The subtex nubby square edge of size 595 x 595 x 15mm shall be placed into the grid size of 600 x 600mm. Ensure arrow marks behind the tiles are oriented in one direction to achieve uniform shade. The systems to achieve noise reduction coefficient not less than 0.9 NRC, so as to have an neat appearance as directed by the department offices. The cost includes, cost of material, cost of labour, scaffolding, transportation, conveyance etc. complying to standard specification.
Supplying, fabricating, erecting and fixing Hilux (or) Equivalent Board False Ceiling upto a ceiling height of 4.5m from floor level. Using Hilux Board Plain Sheets (10mm thick)
Stainless Steel (Salem Stainless Steel) Door Frame (Box Section using Stainless Steel Plate of 1.6mm thick) of size 100mm x 60mm with a rebate of 30 / 35mm x 15mm on one side of the frame including supplying and fixing dovetail splayed end stainless steel hold fast etc.,
Supplying and fixing Solid core flush shutter of nominal thick of 35 mm with Teak ply on both sides and with T.W. lipping alround conforming to IS 2302 including supplying and fixing cost of wind appliances and furniture fittings such as 1no .200 x 12 mm aluminium tower bolt 2 nos. 150x12 mm aluminium tower bolts 1no. 250 x 16 mm aluminium aldrops, 2 nos.200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete as directed by the departmental officers.
Single leaf
Supplying and fixing solid core particle board flush shutter of nominal thick of 35 mm with necessary T.W. internal lipping conforming to IS 2302 with both sides alround Teak ply 3mm thick including supplying and fixing cost of wind appliances and furniture fittings such as 1no .200x12mm aluminium tower bolt 2nos. 150x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 2 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete as directed by the departmental officers.
Double leaves
Manufacturing supplying and fixing of steel door with the following specification MS angles of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter, 3nos. of hinges in case of single leaf and 6nos. of hinges in double leaves shutter to be provided 6nos. of holdfasts 120 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. Tower bolts 2nos. one at the top and the other at the bottom are provided 1no. Aldrop is provided incase of double leaf door at lock rail
section in the door in single leaf door, one more aldrop is provided in the inner lock rail section of the door One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place. Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter t conceal the gap between the two shutters.at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., completea. Single Leaf 1.00x2.10m (Fullysheeted)
Single leaf
Supplying and fixing PVC sliding door for Differently Abled persons toilet in with Solid PVC door shutters using 19 Gauge 19mm MS square tubes for styles and outer frames, 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm, with suitable rabate for housing the shutter including slidng arrangements. PVC sliding door with Roller
Solid PVC door shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm, with suitable rabate for housing the shutter. Solid panel PVC door with frame
UPVC Window Specification:Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and
it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work
UPVC Ventilator Specification:Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
supplying and fixing Ms grills for doors, windows and ventilators of approved design and as directed by the departmental officers including cost of ms grills labour charges and cost of one of red oxide primer coat etc., complete complying with std. specification.
Supplying and painting the walls with two coats of wall putty as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications.
Painting two coats of newly plastered wall surface with ready mixed Plastic Interior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, etc., complete complying with standard specification.
Painting two coats of newly plastered wall surface with ready mixed plastic Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, etc., complete complying with standard specification.
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Supplying, laying and jointing CPVC (chlorinated Poly vinyl chloride) pipe( Higher pressure rating with higher pipe thickness) Standard Dimension Ratio- 11)of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using cement SOLVENT (but excluding cost of such specials) and fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The CPVC pipes shall be got approved by Executive Engineer before use on works. Above Ground level-Internal
25 mm dia CPVC pipe
20 mm dia CPVC pipe
Supplying, laying and jointing CPVC (chlorinated Poly vinyl chloride) pipe( Higher pressure rating with higher pipe thickness) Standard Dimension Ratio- 11)of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using cement SOLVENT (but excluding cost of such specials) and fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The CPVC pipes shall be got approved by Executive Engineer before use on works.
EXTERNAL WATER SUPPLY
Above Ground Level
40 mm dia CPVC pipe
32 mm dia CPVC pipe
25 mm dia CPVC pipe
Supplying, laying and jointing CPVC (chlorinated Poly vinyl chloride) pipe( Higher pressure rating with higher pipe thickness) Standard Dimension Ratio- 11)of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using cement SOLVENT (but excluding cost of such specials) and fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The CPVC pipes shall be got approved by Executive Engineer before use on works.
EXTERNAL WATER SUPPLY
Below Ground Level
40 mm dia CPVC pipe
Supplying and fixing in position the following CPVC Specials of heavy type and approved quality and good variety including the labour for cutting, threading / pasting, sundries, fixing CPVC specials etc., complete complying with standard specification and as directed by the departmental Officers. (The CPVC specials should be got approved by the Executive Engineer concerned before use on works.)
Union
32 mm dia
25 mm dia
Elbow
40 mm dia
32 mm dia
25 mm dia
20 mm dia
CPVC Coupling
40 mm dia
32 mm dia
25 mm dia
20 mm dia
32 mm dia
25 mm dia
20 mm dia
Reducer Tee
32 x 25 mm dia
25 x 20 mm dia
20 x15 mm dia
Reducer Elbow
32 x 25 mm dia
25 x 20 mm dia
20 x15 mm dia
Reducer
32 x 25 mm dia
25 x 20 mm dia
20 x15 mm dia
CPVC Bend
32 mm dia
25 mm dia
20 mm dia
Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work.
32mm dia Gun Metal Gate Valve
25mm dia Gun Metal Gate Valve
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works).
Above Ground Level
110mm dia PVC soil pipe
75mm dia PVC soil pipe
Supplying and fixing in position best Indian make PVC soil pipes of various dia having 6 kg/sq.cm pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC/ MS clamp, TW plugs, brass screw etc and amking connection to all sanitary fittings, dismantling masonry/RCC works wherever found necessary and making good the dismantled portion to the original condition, including testing for any leakages etc., complete complying with standard specifications (PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earthwork excavation will be measured and paid separately in the cases where the pipelinesare proposed to laid below ground level.
160mm dia PVC soil pipe
110mm dia PVC soil pipe
Supplying and fixing in position of the following P.V.C. specials of best approved quality confirming to B .I.S. and providing leak proof joints with P.V.C. adhesive etc, including fixing to walls with necessary teak wood plugs screws etc. and giving connections to the P.V.C .pipe dismantling the brick masonry RCC floor or roof slab and making good the disturbed portion to original conditions etc. complete complying with standard specifications. (The P.V.C. specials should be got approved from the Executive Engineer before use on works).
PV C Elbow
110 mm dia
PVC Door Elbow
110 mm dia
75 mm dia
PVC Y-Single door
110 mm dia
75 mm dia
PV C Bend
110 mm dia
75 mm dia
Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with Crushed Stone(M-Sand) cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two Crushed Stone(M-Sand) and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes (including the cost of 110mm dia PVC pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).
Supplying and fixing in position White Glazed EUROPEAN WATER CLOSET of best quality and approved make with 100mm P or S trap connecting with PVC pipe of 110mm dia, double flapped rigid PVC. seat and seat cover with chromium plate brass hinges, including supplying and fixing 10 litres capacity PVC flushing tank with a pair of CI Brackets etc., complete with all fittings such as 15mm brass valve with polythene float with
brass handle union, coupling connected by means of 40mm white PVC flush and using indian adopter joint including all internal fittings such as 15mm brass connections, 15mm gm wheel valve, 15mm brass nipple (2 nos), 15mm nylon connections TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting CI brackets with 2 coats of approved paint over one coat of red oxide primer , dismantling the masonry and re doing the dismantled masonry to original condition etc. complete complying with standard specifications. The European Water Closet and flushing tank with all accessories should be got approved by the Executive Engineer before use on work. a)White glazed EWC with 10 litres capacity, PVC flushing tank fixed on wall
Supplying and fixing in position best quality and approved make Indian made white glazed earthernware wash hand basin of size 550 x 400mm with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers,
white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). a) White glazed Wash hand basin of size 550x400mm without Pedestal
Supply and fixing in position of best Indian make white glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers. (The urinal should be got approved by the Executive Engineer before use on works.)
Supplying and fixing in position Urinal partition with White Marble slab (Adanga) 18 mm to 20 mm thick of 4'0'' x 2'0''size and above of best quality including dismantling masonry, if necessary and re-doing the same to original condition, etc., complete complying with standard specification. (The Marble slab should be got approved by the Executive Engineer before use on works).
Supplying and fixing in position best quality approved make white glazed Stainless steel sink of size of1200 x 550 x 180mm including cost of 32mm dia CP waste coupling, 32mm dia PVC waste pipe with rubber plug and chain, 15mm dia brass nipple including fixing the sink in position and testing for leakages etc., complete complying with standard specifications excluding CI brackets. [The sink and specials should be got approved by the Executive Engineer before use on works]
Supplying and fixing position PVC Nahani Trap of 100mmx75mm with best PVC gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of Crushed stone sand(M-Sand) and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three Crushed stone sand(M-Sand)) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)
PVC Nahani Trap of size 100 x 75mm with PVC gratings
Supplying and fixing in position 15mm dia. brass C. P. screw down tap ( Heavy duty ) of best approved make and quality including cutting, threading wherever necessary and fixing in position etc., complete complying with standard specification ( Screw down tap to be used on works should be got approved from the Executive Engineer before use).
15 mm dia CP screw down tap
Supplying and fixing in position 15mm dia. brass C. P.Elbow action tap ( Heavy duty ) of best approved make and quality including cutting, threading wherever necessary and fixing in position etc., complete complying with standard specification ( Screw down tap to be used on works should be got approved from the Executive Engineer before use).
15 mm dia CP Elbow action tap
Supplying and fixing best approved best quality brass CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications. (The soap tray should be got approved by Executive Engineer before use on works).
Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks)
Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works).
Supplying and fixing in position CI manhole covers with CI frames (Heavy duty) of size 60cm x 60cm of best approved quality as per standard specification etc., complete compying with standard specifications
Supplying ,Laying & jointing glazed stone ware pipes of following dia best quality with Spigot and socket ends ( in reverse direction ) in dry condition and laid in loose joint ((I.e) without cement and spun yarn so that the waste water can be drained to the trenchs already available , excluding cost of earthwork excavtion , cost of refilling with Crushed Stone(M-Crushed Stone(M-Sand) Sand) Crushed Stone(M-Sand) Sand/ earth , but including laying the pipe in true alignment and gradient and Conducting required water supply test for draining with necessary tools & plants etc Complete complete complying with standard specifications and as directed by the departmental officers a) 100mm dia pipe -Loose Joint
Supplying and fixing in position 100mm dia stoneware tee of approved best quality and provding leak proof joints with cement, spun yarn, etc., including dismantling the brick work and re-doing the dismantled portion to the original condition, etc., complete complying with standard specifications (The stoneware tee shall be got approved by the Executive Engineer before use on work)
Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed by the departmental officers
50 mm thick
Drilling of 6" (150mm) dia vertical borewell to the required depth as directed by the departmental officers in all soils such as hard rock strata including all incidental charges for drilling machineries transportation for rig machineries and supporting vehicle to work spot,charges to fuel required for operation, labour charges for driling bore well to the required depth according to water table as directed by the departmental officers inculding clearing the site after completion of work complying with standard specification.
Supplying, erecting and inserting 150mm dia PVC casing pipe of approved quality and variety without slot to standard length of 6 metre suitable for 6" bore-well including jointing the casing pipe in the PVC couplers with solvent materials in the drilled holes to the required depth conforming to pressure as per IS 4985. The rate is inclusive of cost of pipe, taxes, labour charge for cutting, threading, jointing the pipe, conveyence charges of materials and all other labour charges etc. complete.
Supplying and fixing of suitable PVC endcap (6kg/cm2)for 6"dia borewell of best quality with ISI mark (the PVC endcap should be not approved by the departmental officers before execution)
Supplying laying and jointing CPVC pipes class - V-1MP a with working pressure of 10 kg./cm2 of approved quality and best quality conforming to ISS and with ISI mark of following sizes including cutting threading and fixing CPVC specials but including cost of such specials and fixing into Bore well for suction line, air pipe etc., complete complying with standard specification.
32mm dia CPVC pipe
Supplying and fixing Nylon Rope for Bore-well etc., complete Complying with Standard Specification and as directed by the departmental officers.
Supply of 4.00 sqmm three core flat copper cable with wire bounded punched copper conductor insulated and sheeted with PVC.for submersible pump motor with voltage grade upto 1100V confirming to and marked with IS (694-1990) complying with standard specification etc.complete.
Supplying single phase 3 HP submergible pump of approved make conforming to IS 8034 and all cost of materials. The quality and standard of the product should be got approved by the departmental officers before use on works. Necessary Warranty card should be got approved before erection of submergible pump with all accessories.
Supply three phase capacitor type 5.0 HP monoblock motor with suitable for 220V 50HZ, AC electrical supply with 1420/1440 RPM motor of best quality and make with ISI mark on a suitable pedestal with foundation bolt and nut with panel board with accessories such as 1No. 15Amps DPIC switch, 1 No. voltmetre 0 to 500V with control switch, 3Nos. Indicator lamps with 5 amps control switch,1no. 15Amps fuse carrier and giving electrical wiring connections. The rate includes supplying and fixing of 1no. of foot valve pump set including wiring from panel board to motor, etc., complete (The pump should be tested for a minimum of three days at contractor’s own cost)
Supplying and fixing PVC water tank of approved by quality conforming to ISI specification 2000 litres capacity having suitable cover, bolt including cost of tab, taxes, transportation to work spot, fixing in position a place as shown and directed by the departmental officers including conducting required water test complete complying with standard specification.
Electrical Items: Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) (Higher End )
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End
Wiring with 3 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Modular Light point (Higher End)
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil)(Higher End) (For Street Light Point)
Wiring with 2 x 1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with MS switch Box and 5A FT switch with painting of suitable colour continuous earth wire connection of 1.5 sq.mm copper wire for light point / fan point (for electronic regulator). (For Lift shaft)
Wiring with 2 x 1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with 150mm x 100mm x 75mm MS switch box for 5A 3 pin non interlocking flush type CS plug with painting of suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for open plug point (For Lift shaft)
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3 pin module socket with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point ( 8 points / Coil) Higher End
Supply and fixing of WT bulk head fitting with guard suitable with 7W / 9W LED bulb
supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.
Supply and fixing of 24W LED square type Surface mounting fitting (Havells Integra Nxt DL / Eq) with Aluminium (99% Purity) Sink, available in Sqaure shape. PC diffuser in white powder coated finish with built in electronic low THD (<10%) LED driver 6500K CCT; CRI ≥ 80 with 1.5 sqmm PVC unsheathead FRLS copper wire from terminals to the fitting and necessary connection complete.
supply and fixing of 18W LED Round type Recessed fitting with LED (Higher end) on false Ceiling from ceiling with PVC unsheathed copper leads from terminals to the fitting.
Supply and fixing of single box type 4' 20W LED fitting with CRCA body complete with TW round blocks on wall or ceiling with 20W LED tube with PVC unsheathed FRLS Copper leads from terminals to the fitting. (Higher End)
Supply and fixing of Twin box type 4' 20 W LED fitting with CRCA body complete with conduit pipe suspension from the ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting with 2 nos of 20 W LED tubes. (Higher End)
supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting .
Supply and fixing of 1200mm (48") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 300 mm down rod with fan clamp with side plates and cross arm of size 450mm (18")
Supply and fixing of 300mm (12") sweep (light duty) AC exhaust fan complete without provision of hole in the wall.
Supply and fixing of louvers shutters arrangements for 300mm (12”) sweep (light duty) AC Exhaust fan.
Supply & Fixing of AC / DC 76mm Buzzer /call bell suitable for 230 Volts 50 c/s single phase AC supply on suitable TW round block with 1 Module GI flush mounting box, 1 Module combined plastic cover plate and 1 module Modular type Bell push Switch with indicator complete (Higher End).
Supply and fixing of 3nos.6A two module socket, 1no. 6/16A two module socket, 3nos. 6A one module switch, 1no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI) in flush with wall with connections. Higher End
Supply and fixing of 1no. 6/16A two module socket, 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI) in flush with wall with connections. Higher End
Supply and fixing of 32A, 10kA Double pole MCB in sheet steel enclosure in flush with wall and making good of the concealed portion with necessary earth connection. (The MCB and metal enclosure should be of Higher End).
Supply and fixing of 32A, 10kA FP MCB in sheet enclosure in flush with wall and making good of the concealed portion with necessary earth connection. (The MCB and metal enclosure should be of Higher End). (For pump and RO)
Supply and fixing of 63A, 10kA FP MCB in sheet enclosure in flush with wall and making good of the concealed portion with necessary earth connection. (The MCB and metal enclosure should be of Higher End). (For Ductable AC units & UPS)
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 20A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End
Supply and fixing of 4 way 7 segment triple pole neutral MCB distribution board in sheet steel enclosure double door type with metal door with IP 42 protection with 25A 4 pole MCB as incoming and 3Nos 25A DP RCCB with 30mA sensitivity as sub incomer and 12Nos. 6 A to 20A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. (Higher End) (To LDBs)
Supply and fixing of 4 way 7 segment triple pole neutral MCB distribution board in sheet steel enclosure double door type with metal door with IP 42 protection with 40A 4 pole MCB as incoming and 3Nos 40A DP RCCB as sub incomer and 12 Nos. 6 A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. (Higher End) (Set plug - UPS DB)
Supply and fixing of 6 way 7 segment triple pole neutral MCB distribution board in sheet steel enclosure double door type with metal door with IP 42 protection with 63A 4 pole MCB as incoming and 3Nos 63A DP RCCB as sub incomer and 18Nos. 6 A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. (Higher End)
Supply and fixing of 4 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB as incoming and 3 nos. 32A TP MCB, 3 nos. 6A to 32A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. Higher End (for UPS DB)
Supply and fixing of 4 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 100A 4P MCB as incoming and 3nos. 63A TP MCB, 1no 32A TP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. Higher End
Supply and fixing of 63A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with earth connection only. (For Lifts)
Supply and fixing of 315 A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with earth connection only. (For TNEB Mains)
Supply and fixing of dust and vermin proof cubical type LTCT metering box of size 3ft x 1 ft x 4ft made of 16SWG CRCA sheet steel with door, lock and key arrangement with angle iron support comprising of three compartments for 3 phase energy meter with base plate & view glass arrangements, bus bar arrangements with 1 1/4" x 1/4" insulated tinned Copper bus bar for 3phases & neutral with provision for CTs and sealing arrangements as per TANGEDCO norms
and 3nos 315A (500V) fuse units and MS cable entry box. The earth bus with two runs of 1 1/4" x 1/8" tinned copper flat must be run all round the panel to provide double earth connection.The buses should be mounted on the SMC bus insulators with proper spacing and should be provided with heat shrinkable sleeves using RYB & Black colours.The bus bar chamber should be segregated from the adjacent chambers by providing 12mm thick hylem sheet. The panel should be painted with two high quality enamel paint over one coat of red oxide primer, the cable size, location etc., should be marked with white paint affixed with Danger sign with 19/16 PVC insulated Cu wire interconnection from meter to fuse unit and necessary connection complete cconfirming IE rules.
Supply and fixing of 3 phase 315A aerial fuse unit for 3 nos 315A fuse units(500V) on suitable MS sheet covered with 6mm thick hylem sheet on suitable angle iron work the tapping pole with necessary clamps.
1. 315 A TPN switch disconnector fuse units interior only with HRC fuses double break-1No (2) 250 A TPN switch disconnector fuse units interior only with HRC fuses double break-2 Nos (3) 200 A TPN switch disconnector fuse units interior only with HRC fuses double break-2 Nos(4) 63A TPN switch disconnector fuse units interior only with HRC fuses double break- 2Nos.
In each cubical switch, live portion of bus bar should be shrouded by 6mm thick hylem sheet sepearator, and properly earthed by tinned solid copper flat as I.E rules CEIG specifications. The earth bus with two runs of 11/4"x1/4" tinned copper flat must be run all round the panel
to provide double earth connection. The panel should be painted with two high quality ename paint over one coat of red oxide primer, the cable size capcity of switch loaction etc, should be marked with white paint and metalllic danger board affixed complete with mounting on base channel 3"x11/2"x1/2" iron frame work support complete (The TPN switches should be L& T/ siemens make only.) (Incoming supply)
Supply and run of 2 of 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in rigid pipe concealed in wall and ceiling and making good of the concealed portion with suitable colour. [For call bell, Inverter]
Supply and run of 2 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with contiinuous earth wire connection of 6 sq.mm copper wire and making good of the concealed portion with suitable colour (For LDBs)
Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire and making good of the concealed portion with suitable colour (For AC Plugs and Computer Set plug)
Supply and run of 4 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 6 sq.mm copper wire and making good of the concealed portion with suitable colour (For 32 A FP MCB & 7 Seg - Light pt)
Supply and Run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed position. (For 63A incoming DB's, 63A 4P)
Supply and Laying of 3 1/2 x 35 sq.mm. aluminium PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.(For 63A Mains & Pump room)
Supply and clamping of 3-1/2 x 35 sq.mm. aluminium PVC LTUG armoured cable on post or on wall with MS clamps.
Supply and fixing of brass cable gland for 3-1/2 x 35 sq.mm. aluminium PVC armoured LTUG cable with earth connection
Supply and providing cable end termination of 3-1/2 x 35 sq.mm. aluminium PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete.
Supply and clamping of 3-1/2 x 50 sq.mm. aluminium PVC LTUG armoured cable on post or on wall with MS clamps.
Supply and frxing of brass cable gland for 3-1/2 x 50 sq.mm. aluminium PVC armoured LTUG cable with earth connection.
Supply and providing cable end termination of 3-1/2 x 50 sq.mm. aluminium PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete.
Supply and clamping of 3-1/2 x 185 sq.mm. aluminium PVC LTUG armoured cable on post or on wall with MS clamps. (From Panel to raising mains)
Supply and fixing of brass cable gland for 3 1/2 x 185 sq.mm aluminium PVC LTUG armoured cable with earth connection.
Supply and providing cable end termination of 3 1/2 x 185sqmm PVC LTUG Aluminium armoured cable withnecessary aluminium cable sockets by crimping etc. with electrical connection comple.
Supply and clamping of 3 1/2 x 240 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps. (For LTCT Service, main switch)
Supply and fixing of brass cable gland for 3 1/2 x 240 sqmm PVC armoured LTUG cable with earth connection.
Supply and providing cable end termination of 3 1/2 x 240 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete.
Supply and fixing of 300mm width x 50mm height GI Hot dip galvanized powder coated 16SWG preforated cable tray on ceiling or wall with suitable fastereners, bolt nuts, clamps and necessary connection complete.
Supply and fixing of 65mm (2½") G.I. pipe (Class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting & masonry work for fixing the post (for cable tray)
Earthing as per the ISI specification with an earth electrode of 2.1mt class 'B' GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry.
Earthing as per P.W.D standard with an earth electrode of 2 Mtr. Class 'B' GI pipe of dia not less than 32mm complete with necessary masonry work.
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection.
Supply and fixing of 2kVA Single Phase In & Single Phase out Online UPS of Microcontroller based High frequency and Double Conversion Online Technology with inbuilt isolation transformer system, LCD/ LED Display with suitable SMF battery to provide minimum 1hour backup along with Powder coated MS Rack and interlink cables with following specifications: 1.Output Voltage Range : 208V/220V/230V/240V AC 2. Voltage THD (Linear Load) : ≤2% 3. Voltage THD (Non-Linear Load) : ≤4% 4. Current THD : < 10% 5. Overload : >110%, 30s turn to Bypass mode; >150% instant turn to Bypass mode 6. Short Circuit protection : 5 cycles turn off inverter, no transfer to Bypass, provide Alarm (AC mode) ; 5cycles turn off inverter, provide Alarm (Battery mode), Input fuse blown or breaker action 7. Waveform : Pure sinewave 8. Transfer time : (AC mode to Battery mode - Zero) (Inverter to bypass - <4ms) 9. Efficiency : 85% to 92% 10. Noise Level : less than 50dBA @ 1meter (with fan speed control) 11. Warranty : Two years on Electronics & one year on battery.(Microtek / Numeric make / Eq), (Battery make : Exide)
Supply and fixing of 15kVA Three Phase In & Single Phase out Online UPS of Microcontroller based High frequency and Double Conversion Online Technology with inbuilt isolation transformer system, LCD/ LED Display with suitable SMF battery to provide minimum 1hour backup along with Powder coated MS Rack and interlink cables with following specifications: 1. Output Voltage Range: 208V/220V/230V/240V AC 2. Voltage THD (Linear Load) : ≤2% 3. Voltage THD (Non-Linear Load) : ≤4% 4. Current THD : < 10% 5. Overload : >110%, 30s turn to Bypass mode; >150% instant turn to Bypass mode 6. Short Circuit protection : 5 cycles turn off inverter, no transfer to Bypass, provide Alarm (AC mode) ; 5cycles turn off inverter, provide Alarm (Battery mode), Input fuse blown or breaker action 7. Waveform : Pure sinewave 8. Transfer time : (AC mode to Battery mode - Zero) (Inverter to bypass - <4ms) 9. Efficiency : 85% to 92% 10. Noise Level : less than 50dBA @ 1meter (with fan speed control) 11. Warranty : Two years on Electronics & one year on battery.(Microtek / Numeric make / Eq), (Battery make : Exide)
Supply and installation of air termination rod of 2mtr length of material AlMgSi of diametre ø 16/10 mm crimped on both the ends (Tappered Type). The rod shall be mounted with stainless steel clamp and fixing accessories. It should satisfies IEC 62561-1 & 2 and it should Withstand Minimum wind velocity of 150m/s.
Supply and clamping of 8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used as down conductor system with necessary Conductor Holder,glue, connectors, joints and expansion piece etc as per IEC 62561-2 recommendation and site condition
Supply and run of Rust resistant non corossive 10 mm dia Copper Bonded Steel round conductor used for Earth termination inside the concrete and soil with necessary masonary and excavation work.
Supply of Maintenance Free Copper bonded Earth rod of 3000mm length having the dia of 17.2 mm with copper coating thickness of 254 microns. The rod has been tested for Dimension, Marking, Tensile Strength, Salt mist, coating thickness, Electrical resistivity test before and after corrosion test as per IEC 62561-2.
Supply and Installation of Battery operated LCD type Lightning counter - LCD screen shows the number of lightning strikes, hour and date of lightning events Buttons enable TIME/DATE setting and log viewing. Replaceable battery, working life minimum five years, Complies with IEC/EN 62561-6.
Supply and insallation Cabinet Type Class 1 and 2 Combined Model SPD in 4P enclosure box to arrest surges and overvoltages in the power linedue to lightning, switching action etc. they must be installed in the incoming MCC panel / DB of the respective buling in parallel to the power circuit by using 4 of 6 Sqmm Cu(84 / 0.3) .Model: PSV4-12.5/400TT (3 phase power network)
Supply, Testing Commissioning and Handing over of 125 KVA Diesel Generator set with acoustic enclosure conforming to CPCB IV+ Norms and BIS Specifications of 0.8 P.F. Three phase 415V/ 420 Volts, 50Hz, 1500 RPM CPCB Approved capacity developing 156 BHP with acoustic enclosure water cooled clock wise rotating feed pump with 100KW/ 125KVA operating capacity brushless alternator close coupled underneath fuel tank standard safeties LLOP with stop solenoid battery with lead Electric start and vibration fitting and accessories and AMF panel as detailed below including transporting & unloading charges.
(A) Engine: Water cooled diesel engine suitable for Generator application conforming CPCBIV+ norms and IS standards with a shaft out put of 156BHP at 1500 RPM under NTP conditions. The Engine shall comprise the following standard fitting flexible coupling fly wheel, air cleaner, fan blower, radiator, water pump, fuel filter, lubricating oil filter, etc.(Kirloskar Green / Cummins)
(B) 12/24 Volt Electronic starting Equipment: Complete with starter motor, dynamo, standard batteries with cable, flexible exhaust piping of 50cms length
(C) Engine Instrument Panel / Mounted: Starting push botton / starting key, lubricating oil, temperature gauge, lubricating oil pressure gauge, water temperature gauge, safety control for low lubricating oil, pressure, safety control for high water temperature, safety control for over speed, hour meter (mechnical ) and RPM indicator, battery charging ammeter. The engine should be capable of providing 10% over load for one hour for every 11 hours continuous at full load.
D)ALTERNATOR: 125KVA/100KW Capacity of brushless alternator, AC 3 phase, 50Hz, 415/420V, 0.8 PF, 1500 RPM under NTP conditions, conforming to CPCB IV+ Norms.
(E) AMF CONTROL PANEL: The AMF control panel (cubical) should be fabricated with vermin proof and dust proof best quality sheet steel and floor mounted with removable rear panels and hinged front doors with enamel painted and incorporating the following with suitable provision for connection incoming and outgoing leads having been made on the control panel.
30.1No Earth fault relay 31.Isolator to isolate the neutral 1. The control panel should be complete with necessary fuses, cables, label, other accessories with neutral isolation arrangements. 2. The engine should trip for the following: a) Low lubricating oil pressure b) High water temperature c) Over speed 3.Supply and fitment of Auto Mains Failure Panel, 1 EB Service wih 200 Amps switch and contactors SUF Control relays, timers etc suitable for auto change over of DG & EB Service. F.FUEL TANK 230 litres fuel tank shall be fabricated out of 14 SWG CRCA MS sheet and is part of base frame. It is duly painted and fitted with inlet and outlet connections and mechanical fuel gauge. Fuel tank can be easily removed for cleaning or any maintenance.
G.BASE FRAME: Base frame should be fabricated with MS channel frame of rigidly welded construction for mounting of generaor set. The engine and alternator should be coupled by suitably designed diaphragm type flexible coupling with guard and mounted on the base frame with proper alignment.
H) ACOUSTIC ENCLOSURE: The Acoustic enclosure, Self standing weather proof Acoustic canopy conforming CPCBIV+ norms floor mounting type with modular construction with the provision to assemble and dismantle easily and designed to suit all weather condtions and compliance to IS standards. Erection of acoustic enclosure suitable for 125KVA Diesel generator complete with all accessories as above and suitable supports etc. as approved by competent authority to suit updated CPCB norms.
I) Erection of generator set with proper alignment over the existing foundation.
J)Supply of manuals for operation & maintenance of DG set with warranty card etc. K) CEIG approval: Preparation of site plan physical layout, electrical line schematic Diagram 10 sets, getting drawing approval from CEIG preparation of complection report rectification report etc., arranging CEIG inspection and obtaining CEIG safety certificate, payment of CEIG inspection fees if necessary and preparation of one set of approval Drawing and copy of safety certificate in a neat frame work.
(L)TESTING AND COMMISSIONING After the installation of DG set on its foundation, the DG set should be tested and commissioned with first charging of lubrication oil to its level, first charging of battery and run the set for eight hours on full load test complete. The Genset engine and alternator make should be approved by department officials before used on work. (SR)
Supply and fixing of Exhaust Pipe with Silencer for Genset.
Providing suitable concrete foundation with cement concrete 1 : 2: 4 for height of 2 feet with sand cushion all around the foundation and erection of 125 kVA Generator set with proper alignment over the foundation
Supply and errection of 1.5 Ton (4500 K.cal/hr) ABS Plastic Split type Inverter Air conditioner conforming to IS 1391 (Part-2) 1992 with Amdt No. 1 to 2 fitted with inverter compressor operating on refrigerant of non CFC suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with 5 star rating as per BEE specification and capable of performing the functions
1) Cooling 2) Dehumidifying 3) Air circulating 4) Filtering The installation work for the above split type AC units inculdes the following 1. Mounting/ Fitting Indoor and Outdoor units at the respective locations. 2. Laying refrigerant pipeline of required length not exceeding 4 metres distance and connecting both units after drilling hole/holes in the wall, if required. Thickness of copper tubing shall not be less than 0.8mm 3. Insulating the suction pipe with expanded polyethelene foam 5mm tubing 4. Laying 25mm dia flexible PVC drain pipe to throw out the condensate water being formed with in the indoor unit. 5. Leakage testing the entire system. 6. Charging refrigerant gas in the unit. 7.Suitable electric wiring to be provided with 2.5 sqmm PVC insulated copper wire between indoor units upto 6 mtrs length and up to switch with in 3 meters of the location of indoor unit. (Carrier / Bluestar / O-General / Daikin)
Supply erection, testing and commissioning of 2.0 TR (6000 K.cal/Hr) ABS Plastic Split type Inverter Air conditioner conforming to IS 1391 (Part-2) 1992 with Amdt No. 1 to 2 fitted with inverter compressor operating on refrigerant of non CFC suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with 5 star rating as per BEE specification and capable of performing the functions 1) Cooling 2) Dehumidifying 3) Air circulating 4) Filtering
The installation work for the above split type AC units inculdes the following 1. Mounting/ Fitting Indoor and Outdoor units at the respective locations. 2. Laying refrigerant pipeline of required length not exceeding 4 metres distance and connecting both units after drilling hole/holes in the wall, if required. Thickness of copper tubing shall not be less than 0.8mm
3. Insulating the suction pipe with expanded polyethelene foam 5mm tubing 4. Laying 25mm dia flexible PVC drain pipe to throw out the condensate water being formed with in the indoor unit. 5. Leakage testing the entire system. 6. Charging refrigerant gas in the unit. 7.Suitable electric wiring to be provided with 2.5 sqmm PVC insulated copper wire between indoor units upto 6 mtrs length and up to switch with in 3 meters of the location of indoor unit. (Carrier / Bluestar / O-General / Daikin)
Supply and Installation of 4 KVA Electronic Automatic Voltage Stabilizer V- GUARD make VND 500 Model with Input Voltage range of 150Volt - 285Volt and Output Voltage range 200Volts to 230 Volts with High and Low Voltage cut off and 3 minutes time delay relay with demonstration.
Supply and Installation of 5 KVA Electronic Automatic Voltage Stabilizer V- GUARD make VND 500 Model with Input Voltage range of 150Volt - 285Volt and Output Voltage range 200Volts to 230 Volts with High and Low Voltage cut off and 3 minutes time delay relay with demonstration.
Supply and laying of 5/8" and 3/8" soft drawn copper refrigerant pipe of 0.8mm thick by flaring connection with interconnection wire between indoor & outdoor unit and 25mm drain pipe. (Extra beyond 3 mts/AC unit)
Supply and fixing of MS stand for fixing outdoor unit.
Supply, Installation, testing and commissioning and handing over of Air-Cooled self contained ceiling suspended 8.5 TR Ductable airconditioning units with indoor unit comprising scroll type compressor, evaporator coil, fan motor controls & insulated drain pan enclosed in a sheet metal cabinet and outdoor unit comprising Condenser coil & fan enclosed in powder coated sheet metal cabinet Unit shall be suitable for operation on 415V ∓ 10% Volts,50 HZ, AC Supply, units shall be supplied with microprocessor control panel. (Make : Blue star/Carrier/Eq)
Supply, fabrication and fixing of MS channel for mounting the Airconditioning Indoor Unit.
Supply, fabrication and fixing of MS channel for mounting the Airconditioning Outdoor Unit.
Supply and filling of R410A Refrigerant Gas
Supply, Fabrication and Erection of fabricated ducting made up of GI sheets of 22 Gauge thickness.
Supply, Fabrication and Erection of fabricated ducting made up of GI sheets of 24 Gauge thickness.
Supply and providing Acoustic for initial portion of Ducting with 12mm thick fiber glass rigid board covered with Tissue Paper and Aluminium Perforated Sheet.
Supply and fixing of extruded Aluminium powder Coated, supply and return Air Grilles / Diffusers with volume control dampers.
Supply and fixing of flexible Canvas connection
Supply and fixing of Duct Mouth Dampers
Supply and fixing of 50 mm thick Anti Vibrating Rubber Pads
Supply and providing thermal insulation of 9 mm thick vidoflex with Aluminium Foil.
Supply and fixing of Refrigirant piping out of hard drawn copper pipe set of 28.60 mm size
Supply and fixing of Refrigirant piping out of hard drawn copper pipe set of 15.9 mm size.
Supply and providing of pipeline nitrile rubber insulation for refrigerant and drain pipe lines
Supply and providing of 1.5sqmm copper flexible cable
Supply and providing of 0.5sqmm 4 core flexible signal cable
Supply and fixing of 1" PVC water drain pipe line
Design, Supply,Installation, Testing of 400A, 3L+N, Sandwich type Aluminium Bus Bar Trunking system, Straight run feeder (Rising Main)Indoor IP55 protected, insulation class F (155oC), Dust and Vermin proof made up of Galvanised iron, with provisions for Aluminium Earthing Plug in points at every floor necessary angle iron supporting etc.Reference standard: IEC 61439-6. Reference temperature: 40 °C, Protection degree: IP55. Thickness: 1.6 mm, N° of conductors: 4. Painted: RAL 7032 . Halogen Free, The insulation between bars is ensured by a multi sheath made with PET film class F(155°C)Complete with Aluminium busbar Flexible with provision for rotary handle mechanism with bottom Cable entry and top Busduct outgoing provision and connections complete.
Supply and Installation of 250A MCCB with suitable enclosure and Acessories and earth connection complete
Supply and Installation of 400A Flange End for raising mains with necessary accessories and connections complete.
Supply and Fixing of Tap Boxes 100A 25KA MCCB with suitable enclosure and Acessories and earth connection complete
Supply and Laying of 25x6mm Aluminimum Earth Flat with necessary clamps/supports for earth connection.
Supply and Fixing of MS Supports for with necessary accessories for fixing Rising Main.
Design, Engineering, supply, fabrication, erection, testing, commissioning and handing over of 13 persons capacity, 884 Kg, Passenger Lift with M/C room, Speed 1.5 m/s with Stainless Steel Panels, Disable friendly, microprocessor based controller &, VVVF drive with enhanced ride comfort and leveling functions, Fire rated doors and ARD, single side entry, gearless Lift as per the following specifications for Commercial Tax Building at Palayamkottai No. of floors: Ground +4 floor, 5 stops
6. Total Travel: 14.4 metres 7. Levelling Accuracy: High level accuracy with smooth and jerk free stopping. 8. Construction of Car: High quality stainless steel car with Neat hair line finish vinyl flooring and false ceiling. 9. Position of machine: Directly above the lift shaft. (Gearless) 10. No. of landing entrance: 5 11. No. of car entrance: one 12.Car entrance door: Power operated V3F drive Centre opening sliding stainless steel scratch proof door with hair line finish. 13. Landing entrance door: Centre opening stainless steel door with hair line finish with provision for emergency key opening at all landings. 14.Lift well existing: 1900mm (width) x 2500mm (depth) (As per IS 14665 Part I 2000) 15. Lift pit depth 1600mm (as per IS 14665) (part I) – 2000) 16.Car size: 1100mm (width) x 2000mm (Depth) as per IS 14665 (part I) – 2000) 17.Car clear opening: 900 mm width x 2000mm height (as per IS 14665) (part I) – 2000)
31.Servicing and maintenance: Free comprehensive servicing and maintenance should be provided by lift contractor during the guarantee period of one year. 32. Automatic Rescue device: To facilitate the landing of the lift to the nearest floor at the time of power failure. This shall consists of suitable type battery system with charger, invertor, under voltage protection system etc., complete with all accessories. 33. Intercom:To be provided by the lift contractor with in-built intercom ( push type) in car panel and with provision of push type intercom in machine room and ground floor entrance. 34. Floor annunciator with music with announcement in both Tamil and English. 35. Special features: a. Infra-red door sensor with full height screen c. Voltage stabilizer for circuit control. d. Stainless Steel signal fixtures. e. Vandal proof S.S. Button with S.S. cover f. SS door frames for landing doors. g. VF door operator. h. Call Register signal i. Stainless steel facia plate for car operating panel and landing fixtures. j. On – Off switch for fan and light k. Over load warning indicator with audio announcement
36. Other standard features: Over speed governor, phase failure and phase reversal relay alarm bell, T. Guide brackets for car and counter weight, rubber padding under winding unit, motor of adequate capacity, electro magnetic brake with compression springs car safety gears buffer, electro mechanical door locks emergency key side supporting angles, motor over load protection devices final limit switch main suspension ropes counter weights lifting joint joist for mounting the machineries. 37. Guarantee: Guarantee for the materials and workmanship of equipments complete should be offered by lift firm for a period of not less than one year. 38.Site testing in accordance with IS 14665 should be carried out at the time of handing over. 39. Supply of operation and maintenance manual with necessary tools for operation. 40. Lift licence : Preparation of drawing, payment of charges to CEIG and insurance policies if any and obtaining CEIG safety certificate as per lift act should be done by lift contractor. (make: Johnson / Kone/ OTIS)
VARGEESH CONSTRUCTION (BID ID -1148785)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid