Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹13.1 LAccepted-AOC | 1st | Accepted-AOC The lowest bidder M/s Agrawal Builders has been accepted please. | |
| 2 | 2nd₹13.4 L+₹25,785.25 (1.97%)Rejected-Finance 84 A VIJAY NAGAR COLONY LALGHATI PO NAYAPURA BHOPAL 462032 | 462032 | 2nd | Rejected-Finance L2 | |
| 3 | 3rd₹13.5 L+₹40,226.50 (3.07%)Rejected-Finance 10 2 NARAYAN BAG INDORE M P | 3rd | Rejected-Finance L3 | |
| 4 | 4th₹14.5 L+₹1.4 L (10.6%)Rejected-Finance | 4th | Rejected-Finance L4 |
Tender Value
Refer Docs
EMD Value
₹29,800
Closing Date
15 Jan 2021, 6:00 pmClosed
GE AWC MHOW
GE AWC Mhow Baircha Road Mhow Cantt
PROVISION OF STREET LIGHTS AT IB UNDER GE (AWC) MHOW
2020_MES_404662_1
8448 GE(AWC) /MHOW / OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
GE AWC MHOW
All as per Tender Documents and NIT.
7 documents required · 7 mandatory
₹500
Yes
GE AWC MHOW
₹29,800
Yes
25 Jan 2021
18 Dec 2020
16 Jan 2021
18 Dec 2020
15 Jan 2021
2 Jan 2021
Amount
Excavation in trenches in any type of soil, n. exc. 1.5m wide and n. exc. 1.5m deep and getting out for laying of cables/pipes etc including forming bottom surfaces to the required level/slope complete.
Excavating in trenches exc 1.5m wide but exc 1.5m and n exc 3.0m deep for foundation of poles strut/stays etc n exc 10 sqm on plan and getting out in any type of soil.
Returning filling in, including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick in any type of soil complete.
Removal of surplus excavated soil to a distance n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above starting point complete.
Material and labour for approved river sand cushioning for under ground cable in trenches 8 cm before laying and 15cm after laying of cable and punned thickness of sand shall be measured and paid for consolidated thickness complete all as specified and directed.
M&L for cement concrete1:4:8 type D2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L cement concrete 1:3:6 type C2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L for cement concrete 1:2:4 type B1 using 20mm graded stone aggregate in coping & the like etc. including weathering slightly rounded/chamfered angle with & including necessary use & waste of form wk for fair finished surfaces complete all as specified and directed.
Supply and laying galvanised iron pipe 'light Grade' 40 mm in trenches , under floors, roads, along poles for protection of cables with all necessary fittings, including sealing ends complete all as specified and directed .Make Jindal/Prakash Surya/Tata
Supplying, laying and testing cable XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 Core,complete all as specified and directed (Make:- Polycab,Havells, Gloster) .
Supplying, laying and testing cable XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 4 Core,complete all as specified and directed (Make:- Polycab,Havells, Gloster) .
Supplying and laying unreinforced PCC Cable protection cover , Class LV ,Type1 flat ,size 250mm x 150mm x 40mm as cable protection laid flat width wise complete all as specified and directed
Material and laying steel tublar swaged poles with cast iron base plate, 410-SP-31, as per sample of length 09 Mtrs duly painted, finial taper plug,bolts, nuts,& screws complete all as specified and directed.Make- NTC Kanpur/Bharat Conduit/ BCW Kanpur
Supply and Fixing steel tublar swan neck pole with cast iron base plate, 410-SP-31, as per sample of length 09 Mtrs duly painted, finial taper plug,bolts, nuts,& screws complete all as specified and directed. Make- NTC Kanpur/Bharat Conduit/ BCW Kanpur
Supply and Fixing steel tublar swan neck pole with double swan neck and cast iron base plate, 410-SP-31, as per sample of length 09 Mtrs duly painted, finial taper plug,bolts, nuts,& screws complete all as specified and directed. Make- NTC Kanpur/Bharat Conduit/ BCW Kanpur
Supply and fix high quality integrated LED Luminaire with a system lumen of minimum 15000 Lm and system wattage of maximum 120 W with an efficiency 125 Lumen/Watt. CCT of 5700K with SDCM of < 5 and CRI > 70D. The housing should be top openable and of high quality presser die cast aluminium LM 6 alloy with PF > 0.95 and THD<10% & Surge Protection of 4 kV. Input voltage of 140 - 270 V. Life time of 50k hours @L70. Product should be suitable for continuous operation (16 to 18 Hrs/day). The Ingress protection should be minimum IP 66 with an IK rating of 08. The luminaire should have Integrated peanut optics to provide a high quality glare free lightning system. The luminaire should be of Class - B serviceability. The luminaire should be compliant to CISPR-15 & IES 61547 (EMC, EMI compliant). The Driver should be potted/encapsulated & should be a BIS approved Driver & not a printed circuit board without casing, mounted inside luminaire.The luminaire should be capable of withstanding voltage stress of 440 V for 8 hours should have an auto shutdown @325 V and have an auto recovery feature. It should have a provision of 10 kV series SPD in the same housing. BIS approval for board driver & the luminaire needs to be submitted for records. LM 79 & LM 80 reports must be submitted from a NABL accredited laboratory all as complete all as specified & directed. Make- Philips (BRP 340 LED 138 CW HO SLC S1 PSU GR), Bajaj, Havells.
Supply & fixing of LED street light fitting 90 W having system Efficacy >125 lm/W, system output of minimum 11500 Lumens, THD< 10%, PF>0.95, CRI >70, CCT 5700, Full IP 66 (with out Glue) protected single piece die cast aluminium housing having toughned glass/PC with Impact resistance IK07, Luminaire should be suitable for pole dia of 48 - 60 MM. LED driver should be potted & Encapsulated. BIS compliant driver should sustained 440 V stress voltage protection for 8 hours, high cut off : 325V(+/- 15 V) & should have feature of auto restart. Driver shall have 4 kV surge protection & feasibility of 10 kV external SPD housed in luminaire. The luminaire should be of class B serviceability . BIS approval for both driver & the luminaire needs to be submitted for records. LM-79 & LM-80 reports must be submitted from a NABL accredited laboratory all as complete all as specified & directed. Make- Philips (BRP 409 LED 115 CW SLA FG PSU GR V2), Bajaj, Havells.
Supply & fixing of LED street light fitting 70 W having system Efficacy >120 lm/W, system output of minimum 8200 Lumens, THD< 10%, PF>0.95, CRI >70, CCT 5700, Full IP 66 (with out Glue) protected single piece die cast aluminium housing having PC with Impact resistance IK07, Luminaire should be suitable for pole dia of 48 - 60 MM. LED driver should be potted & Encapsulated. BIS compliant driver should sustained 440 V stress voltage protection for 8 hours, high cut off : 325V(+/- 15 V) & should have feature of auto restart. Driver shall have 4 kV surge protection & feasibility of 10 kV external SPD housed in luminaire. The luminaire should be of class B serviceability . BIS approval for both driver & the luminaire needs to be submitted for records. LM-79 & LM-80 reports must be submitted from a NABL accredited laboratory all as complete all as specified & directed. Make- Philips (BRP 062 LED), Bajaj, Havells.
Supply and fix LED Post top light (including bulb of 5 star rating) to be used with 9 W bulb of E27 base having powder coated aluminium housing and with high great polymar gaskit, including IP 65 rated with rotationally symmetric light distribution. Operating voltage of 20 - 240 V, 50 Hz all as complete all as specified & directed. Make- Philips (Glide post Model No. : 58175), Bajaj, Havells.
Supply and fix LED Garden spike light 7 W having system output of minimum 300 lumens, CRI > 80, full IP 65 protected, aluminium housing Operating voltage of 20 - 240 V, 50 Hz all as complete specified & directed. CCT as directed by engr-in-charge.
Supplying and fixing in replacement of PVC junction box of size 200mmX160mmX98mm , including connector block , two holes for incoming and outgoing cables, providing cable glands double compression as per requirement, providing DIN rail for mounting MCB and Clamps made out of MS FI 25X4mm, MS hexagonal bolts, nuts and washers for arrangements to pole/ surfaces complete all as specified and directed by Engr-in-Charge. (Make-Hensel /Syntex/ Siemens)
Supply, fixing, testing and commissioning in replacement of nature switch of capacity 8 KW single phase consisting power contactor of suitable rating , MCB SP 25 AMPs – 03 No. complete.Make-Swadeep or equivalent
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 32mm X 6mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 3 SSR Part-I with connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt alround earth plate, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover reinforced with 6mm dia bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh, and 40 mm dia GI light grade earth lead protection pipe, complete all as specified and directed.
supply & fix writing for circuit/submain wiring alongwith earth wire with the sizes of 2 x 2.5 sqmm + 1 x 1.5 sqmm earth wire FRLSH PVC insulated copper conductor, single core cable in PVC conduit surface/recessed as required complete all as specified and directed.
S & F MCCB 4P ,415 Volts 25 KA 40-100 Amps complete all as specified and directed. Make:-Havells/L&T/Indo Asian
supply & fix writing for circuit/submain wiring alongwith earth wire with the sizes of 2 x 1.5 sqmm + 1 x 1.5 sqmm earth wire FRLSH PVC insulated copper conductor, single core cable in existing surface/recessed as required complete all as specified and directed.
Drilling (Horizontally) existing road (Maximum 10 mtr wide) suitable for passing GI tubing 40 mm complete all as specified and directed. (GI tubing light grade measured and paid under respected item).
POONAM ELECTRIC INDUSTRY
S.S. Engineers
shanti electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .