Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹5.4 Cr
EMD Value
₹6.8 L
Closing Date
9 Oct 2024, 9:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Directorate of Municipal Administration
RAVINDRA KAMBLE
Construction of Proposed 48 TPD MRF Centre (Material Recovery Facility) of PEB Structure (Primary and Secondary Shed) at Bidar
DMA/2024-25/OW/WORK_INDENT26236
DMA/2024-25/OW/WORK_INDENT26236
Open
Other Works
Two Tender Document System(Two Cover)
DMA City Municipal Council Bidar
8 documents required · 8 mandatory
Satisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)
Executed in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)
Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Owning the following key and critical equipment for this work (xxxx, xxxx, xxxx)
Liquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing works
The Tender should be a KPWD Registered Class-II and Above Contractor (Attach Registration Certificate)
The Tenderer or his identified electrical work and executed similar electrical work totaling Rs.17.09 lakhs in any one year (ie., 2019-20 to 2023-24) along with willingness letter of his identified contractor
Liquid assets and or availability of credit facilities of not less than Rs. 135.86 lakhs (Unconditional Credit lines/Letters of Credit / Certificates from any scheduled Banks) for meeting the fund requirement etc.
Availability by owning at least 50 percentage of the required key and critical equipment for this work and the remaining 50 percentage can be deployed on lease /hire basis for all works provided, the relevant documents Applicants shall indicate the make, year of manufacture, capacity and working conditions of each of the equipments along with RC issued by R.T.O./Sale deed/purchase invoice, hire/lease agreements) shall be furnished Excavator 2 nos, Tippers 4 nos, Self-Loading Concrete mixer / Batching Plant 2/1 Nos
The tenderer should have executed in any one year i.e., 2019-20 to 2023-24 (for a continuous period of 12 months) in last five years, the following minimum quantities of work Earth work excavation / Embankment 3445.00 Cum, PCC/RCC 855.00 Cum, TMT Steel 22.00 Tonne, MS Structural steel 140796.00 Kg, SSM/BBM/Solid Block 602.00 Cum, Plastering 1023.00 Sqm, Galvanised roofing sheet 4714.00 SqM
Satisfactory completed, at least one similar development work of value not less than Rs. 268.50 Lakhs as prime contractor. Executed in any one year ie., 2019-20 to 2023-24.
To qualify for Award of this contract, each Tenderer in his name should have in the last five years i.e. 2019-20 to 2023-24, achieved in at least two financial years a minimum financial turnover (in all classes of civil engineering construction works only) of Rs.1074.00 Lakhs certified by chartered accountant with valid UDIN No.to be furnished along with necessary documents)
₹5,000
₹6.8 L
11 Sept 2024
11 Sept 2024
10 Oct 2024
30 Sept 2024
10 Sept 2024
Construction of Proposed 48 TPD MRF Centre Material Recovery Facility) of PEB Structure Primary and Secondary Shed at Bidar (CIVIL WORKS)
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution li...
Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes...
Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggr...
Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggr...
Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggr...
Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes...
Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/w...
Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR)
Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading,...
Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2...
Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, includi...
Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of appro...
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/...
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per sp...
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional c...
Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (one coats applied @ 0.83 l/10 m²) including preparing the surface after thoroughly cleaning the surface to rem...
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on spec...
Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as pe...
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming...
Providing and fixing Aluminium Turbo ventilator complete as per technical specifications. Non Power Driven with 0.9mm thickness and 38 No.s of Vanes & turbine doom thickness 1mm and total weight not l...
Electrical works
RCC Pole 9 Mtr Long, 145 Kg WL (Dwg No. BESCOM/GM/QS & S/02 Dtd 24.11.2018) as per IS-785
RCC Pole 9 Mtr Long, 145 Kg WL (Dwg No. BESCOM/GM/QS&S/02 Dtd 24.11.2018) asper IS-785
Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth
11 kV, Horizontal Cross Arm - Mild Steel (MS) (Dwg No. BESCOM/GM/QS&S/04 Dtd 24.11.2018)
LT 4 Pin Cross Arm - MS(Dwg No. BESCOM/GM/QS&S/32 Dtd 24.11.2018)
Insulator as per IS-1445 for Ceremic, IS- 7935 for GI Pin, IEC-61109 for Polymeric . 11 kV Ceramic Pin Insulator (Shell only)
Insulator as per IS-1445 for Ceremic, IS- 7935 for GI Pin, IEC-61109 for Polymeric .DISC Insulator 45 kN Porcelain
Insulator as per IS-1445 for Ceremic, IS 7935 for GI Pin, IEC-61109 for Polymeric No. 8 Strain Insulator
ACSR Conductor as per IS-398 (Part - 2/1996) Rabbit ACSR(6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM
Stringing of conductor Squirrel, Weasel, binding of conductor on each insulator and dead ending on strain or disc/strain insulator by means of clamps. Rabbit ACSR.
11 kV, 400 Amps Double Break GOS(Dwg No. BESCOM/GM/QS&S/22 Dtd 24.11.2018)
Insulated GOS Operating Rods
Distribution Transformer - 3 Phase, 11kV/433V Stacked CRGO Core with Oil as per IS-1180 (Part-1): 2014, 500 kVA, Aluminium Wdg, Star 2 (5 Star)
Erection of 300 - 500 kVA Transformer
11 kV, HG Fuse Unit with Solid Core Insulator (Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018)
H - Frame Set for fixing 11 kV, 200 Amps Single Break GOS - (For DP structure for providing New GOS for sectionalisation) - MS
Tinned Copper Fuse Wire, 100 Amps
Erection of Double Pole Transformer Structure using 9 Mtr Long RCC (145 Kg WL)/PSCC (300 Kg WL) Pole including fixing of Structure Materials, Erection of Poles etc., complete for mounting of Transform...
Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment g...
11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Meterin...
Erection of HT metering Cubicle on Platform.
10 kV, 5 kA Lightning Arrester Polymeric type with GROUND DISCONNECTOR
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 240 Sq...
Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and ...
Earth work excavation by manual means for drains, canals, waste weir, draft,approach channels, key trenches, foundation of Buildings & bridges and suchsimillar works in all kinds of soils, as per draw...
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 120 to 240 Sqmm
Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable, 3x240 Sqmm
Heat shrinkable Type Terminations 3x185 to 3x240 Sqmm
7/10 SWG Guy Wire(7/3.251 mm Dia), Std Wt: 680 Kg/KM
Guy Clamp - MS(Dwg No. BESCOM/GM/QS&S/07 Dtd 24.11.2018)
Anchor Rod using 12 mm rounds/Guy Rod - MS (Dwg No. BESCOM/GM/QS&S/07 Dtd 24.11.2018)
LT 2 Pin Cross Arms - GI
Fixing of Cross Arm, Single Top Support, EG Stirrup, Anticlimbing Device, Guy Set, Guarding etc., Fixing of 2 Pin cross arm with Insulator and Braces fixing
Fixing of Cross Arm, Single Top Support, EG Stirrup, Anticlimbing Device, Guy Set, Guarding etc.,Fixing of 4 Pin cross arm with Insulator and Braces fixing
Fixing of V-Shape/Horizontal cross arm including Single Top Support Brace and Insulator fixing
RCC Pole Clamp - GI
Load Break Switch with Panel
Heavy Duty Copper Terminal Long Barrel 240 Sqmm Copper Terminal, Apprx Wt: 218 Gm
GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long,3.2 mm thick with bolt, nut, GI Strips and washer completeMinimum Weight of GI Pipe: 7.3 Kg
Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each
Good Quality Salt for grounding purposes packed in 50 Kg gunny bag
Shed indoor Wiring
Supplying PVC flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF scr...
Supplying PVC flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF scr...
Supplying PVC flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF scr...
Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and...
Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and...
Supplying and fixing PVC/metal conduit Deep junction box19/20 mm deep Junction box .
Supplying and fixing PVC/metal conduit Deep junction box.25 mm deep Junction box . KPWD Comman SR 2023-24 Item No: 1.5.2
Supplying and fixing PVC/metal conduit Deep junction box32 mm deep Junction box . KPWD Comman SR 2023-24 Item No: 1.5.3
Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for.work...
Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for.work...
Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto.wall surface complete. upto 50 mm conduit CC floor . KPWD Comman ...
Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto.wall surface complete. upto 50 mm conduit in brick wall . KPWD Co...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs,.Machine/N...
Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs,.Machine/N...
Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs,.Machine/N...
Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs,.Machine/N...
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing.m...
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing.m...
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing.m...
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing.m...
Supplying and fixing of modular switch & connected accessories on.existing modular switch plate as per IS 3854 and IS 1293.6A One Way Switch . KPWD Comman SR 2023-24 Item No: 3.6.1
Supplying and fixing of modular switch & connected accessories on.existing modular switch plate as per IS 3854 and IS 1293.16A One Way Switch . KPWD Comman SR 2023-24 Item No: 3.6.7
Supplying and fixing of modular switch & connected accessories on.existing modular switch plate as per IS 3854 and IS 1293.6/16A Universal Socket . KPWD Comman SR 2023-24 Item No: 40243
Supplying and fixing of metal clad industrial plugs and sockets. 3pole+earth 440V PLUG.32A . KPWD Comman SR 2023-24 Item No: 3.13.4
Supplying and fixing of metal clad industrial plugs and sockets. 32A . KPWD Comman SR 2023-24 Item No: 3.13.8
Supplying and fixing of metal clad industrial plugs and sockets.2pole+earth 250V PLUG16A . KPWD Comman SR 2023-24 Item No: 3.13.1
Supplying and fixing of metal clad industrial plugs and sockets.16A . KPWD Comman SR 2023-24 Item No: 3.13.5 2pole+earth 250V SOCKET
Supplying And fixing/replacing of 6/16/32A electrical.accessories on existing switch board.16A Three Way 5 Pin Socket
Supplying of 1440rpm heavy duty exhaust fan with bracket blades.suitable to operate on 230V 50Hz, AC Supply complete. 15" Sweep (450 mm)
Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polyc...
Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polyca...
Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polyc...
Supplying and Fixing ..mm dia clampsss A GI pipe bracket upto.2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street ...
Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over.existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires
Supplying of ..feet -PVC Batten with integrated LED tube W.with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power fact...
Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, r...
Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter.on existing panel/wood board
Supply, installation of 4kg Fire Extinguisher Mono Ammonium Phosphate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 6.9 Kg, empty weight 2.9 Kg, Can Height 440MM, Diamet...
Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage curr...
Earth work excavation by manual means for drains, canals, waste weir, draft,approach channels, key trenches, foundation of Buildings & bridges and suchsimillar works in all kinds of soils, as per draw...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
KW 4 INDENT NO. 26236 FINAL.doc
Tender Document • 1.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .