GE (AF) BORJHAR
Garrison Engineer (AF) Borjhar, Military Engineer Services, Guwahati Airport- PO, Borjhar Airport, Guwahati-15, Assam, Pin- 781015, Tele 0361 - 2840127
Repair / maint/ rewinding of ceiling fan, exhaust fan, wall fan and repair to geyser. Repair / maint of internal electrification at Mountain Shadow under GE (AF) Borjhar.
2025_MES_739443_1
8512/BOR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) BORJHAR
MES Contractor enlisted as Class D category b(i) having deposited Standing Security of Rs 1,00,000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
7 documents required · 7 mandatory
₹500
GE (AF) BORJHAR
₹80,000
Yes
12 Nov 2025
12 Nov 2025
17 Dec 2025
12 Nov 2025
10 Dec 2025
26 Nov 2025
Taking down of ceiling fan of any size/ sweep after disconecting the wire from existing ceiling rose and refixing the same after cleaning the dust, oiling, greasing & hanging clamps/Rubber real (if required) complete including providing twin core flexible copper conductor multistranded cord from ceiling rose to connector of fan complete all as specified and as directed by Engr -in- charge. Notes : Works will be carried out at the site.
Servicing of ceiling fan of any make and sweep after opening and cleaning rotor bearing and stator properly and oiling/ greasing of bearing/ bushes, reassembling the same, fixing and connecting on its existing position and testing on completion all as specified and as directed including taking down. Note : (a) Overhauling of ceiling fans will be carried out at AGE E/M Yard only. (b) The spares required shall be measured and paid separately in the relevant items.
Taking down old unserviceable rusted ceiling fan blades and providing new ceiling fan blades with fixing new screw as apporpriate shape/ size suitable for ceilling fan of any make and size 1200/ 1400 mm sweep complete all as specified and directed.
M&L for replacement of wall fan blades, made from ABS plastic of suitable size complete all as specified and as directed.
Painting of ceiling fan 1200/1400 mm sweep/ Exhaust fan 225 to 450 mm sweep complete including fan blade down rod with synthetic enamel paint of white in colour including cleaning and removing dust and dirt and making smooth surface for painting including writing MES No complete all as specified.
Taking out/ removing of worn out gun metal bush and supply and fix new gun metal bush for various make of ceilling fan of size 1200 to 1400 mm sweep complete all as specifide and as directed (Make - MSP).
Supply and fix bearing for ceiling fan. (Make - TATA/SKF No.6201).
Supply and fix bearing for ceiling fan. (Make - TATA/SKF No.6202).
Supply and fix bearing for ceiling fan. (Make - TATA/SKF No.6203).
Supply and fix bearing for ceiling fan. (Make - TATA/SKF No.6204).
Taking out/ removing of defective capacitor and supply and fix new capacitor of 2.25/ 2.5 MFD 230 volts with conector (capacitor holder with nut) including PVC clamps nuts, as approved make for various make of ceilling fan complete all as specified as directed (Make – USHA / UNIVERSAL).
Taking out/ removing of defective capacitor and supply and fix new capacitor of 4 MFD as approved make for various make of exhaust fan complete all as specified as directed (Make – USHA / UNIVERSAL).
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 of SSR Part-I (2009) including filling of charcoal dust, common salt all around Earth plate upto 150mm, 20mm bore GI medium grade watering pipe, 15 mm bore light grade earth lead protection pipe upto main board, funnel with wire mesh, 40mm thick RCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate reinfor
Refixing or hanging only ceiling fan after re-winding fan under Serial item No. 13.00 here in above and connecting up including provision of 3 core 1.5 Sqmm cable from ceiling rose or connector to fan (max up to 1m length) all as specified and directed
Takning down/ removing of exhaust/ wall mounted fan of any type and size after disconnecting the conection from exiting ceiling rose to connector and transportation to work shop /cleaning externally dismantling and examining the rotor/ stator / bearing/ bushes etc for serviciablity/ repairing/ replacing/ defective parts and oiling /greasing/re-asembling/ testing for propper functoining checking for safety/ security and propper locking transporting back to building / site to workshop/ hanging / fixing and connecting the electrical conection testing of noise free smooth runing etc. all as directed
ced with suitable handle and angle iron frame and necessary excavation and earth work in any type of soil etc. complete all as specified and as directed including testing on completion. Note : The rate quoted shall inclusive of GI wire 4 mm dia with GI pipe protection 15 mm, light grade up to 7.5 mtr.
Fixing only Exhaust fan after winding fan any hight under Serial item No. 15.00 here in above and connecting up including provision of 3 core 1.5 Sqmm cable from ceiling rose or connector to fan (max up to 1mtr length) all as specified and directed
Supply only Split pin
Supply, fixing and connecting up flexible copper wire twin core of 23/.0078.
Removing brocken/ cracked Canopy of any make and type and supply and fix new canopy of existing make and size all as directed. Make : Usha/ Orient/ Keasal/ Himadri/ Thermacool /Jet airway
S&F rubber reel/ pad of suitable size for ceiling fans of any size and any make as required complete all as specified and as directed
S&F metallic clamps for hanging of ceiling fans with nuts and bolts, split pin and rubber bush, etc. complete all as specifed and as directed
S&F alloy steel heavy duty 'D' hook hanger with M10 x 75mm fasteners for hanging of ceiling fans complete all as specified and as directed.
S&F fastner bolts with nuts and washers of size 4 inch long, 10mm dia with complete accessories all as specified and as directed.
S&F louver for 300mm sweep exhaust fans made of 0.5mm thick GI sheet including taking down old corroded one complete all as specified and as directed.
Taking down carefully storage type water heater (Geyser) of any type and any make upto 50 Litres capacity after disconnecting all electric connections, descaling the inner container, heating element, base assembly etc. by using chemical and cleaning thoroughly, filling the inner container with water and checking and arresting leakage if any, reassembling the geyser after servicing and replacing unserviceable spare parts and refixing including water line connections and testing on completion complete all as specified and as directed: Notes : (i) Spare parts like heating element, thermostats, flexi connection for hot water/ PVC connections etc. shall be measured and paid separately. (ii) Painting shall be measured and paid separately.
S&F copper/ steel tank for geysers of 25 litres capacity including replacement of copper alloy nuts, bolts, etc. complete all as specified and all as directed.
S&F copper/ steel tank for geysers of 50 litres capacity including replacement of copper alloy nuts, bolts, etc. complete all as specified and all as directed.
M&L for repair to geyser inner water tank of 25/ 50 ltrs capacity by gas welding/ brazing for water tightness and testing complete
S&F heating element cup type/ tringular type/ press type/ thread type of 1500 watt make of Usha/Bajaj / Havells all as specified and directed by Engineer-in-Charge
S&F heating element cup type/ tringular type/ press type/ thread type of 2000 watt make of Usha/Bajaj / Havells all as specified and directed by Engineer-in-Charge
S&F thermostat with automatic cut off suitable for geysers of ranges 20 degree Centrigade to 90 degree Centrigade complete all as specified and as directed.
S&F indicating lamp (neon lamp) round or rectangular type suitable for geyser, single phase, 230 volts, 50 Hz complete all as specified and as directed. Note : Two Nos of lamps contain green or ambigo and red colour shall be counted as one unit.
S&F air realese valve for geyser as specified and as directed
S&F Non returned valve 15mm for geyser all specified and as directed
S&F hot water connection pipe heavy duty with steel guarded PVC connection pipe, 450mm long with self locking nut at both ends, 15mm bore complete all as specified and as directed. Make : Havells/ Parryware/ Prayag
S&F steel body top cover for geyser, 50 Litres capacity including necessary screws complete all as specified and as directed. Make : As per sample (ISI marked)
S&F steel body top cover for geyser 25 Litres capacity including necessary screws complete all as specified and as directed. Make : As per sample (ISI marked)
S&F steel body cover (bottom) for geyser 50 Litres capacity including necessary screws complete all as specified and as directed. Make : As per sample (ISI marked)
S&F steel body cover (bottom) for geyser 25 Litres capacity including necessary screws complete all as specified and as directed. Make : As per sample (ISI marked)
S&F apparatus plate with gasket for geysers 50 litres capacity including necessary screws complete all as specified and as directed.
S&F apparatus plate with gasket for geysers 25 litres capacity including necessary screws complete all as specified and as directed.
S&F anchor bolts 75mm long made out of stainless steel complete all as specified and directed
S&F gasket rubber ring of Heater plate of any size geysers.
S&F plug top, 15 Amp, 3 pin, 240 volts complete all as specified and as directed.
S&F 2.5 Sq.mm 3 core, 1100 volt grade PVC insulataed, PVC sheathed copper conductor cable, confirming to IS : 694 for connection of geyser to socket and to 15 amps switch socket combination complete all as specified and as directed.
M&L for galvanised steel water tubing medium grade of 15mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by Engr-in-Charge.
S&F PVC connection pipe, 450mm long with self locking nut at both ends, 15mm bore complete all as specified and as directed. Make : Havells/ Parryware/ Prayag/ Supeme.
Taking down carefully old point wiring (light, fan, socket, bell point or power point) complete including unserviceable fixtures like switches sockets, holders, ceiling roses etc removing from site and keeping in safe custody for taking credit and making good disturbed surfaces of wall/ ceiling with cement plaster in cement mortar (1:6) and distempering / white washing to match the existing surface complete all as specified & directed.
Taking down carefully old unserviceable fittings like FTL, PL, CFL, LED luminaires removing from site and keeping the unserviceable fixtures etc in safe custody for taking credit and making good disturbed surfaces of wall/ ceiling with cement plaster in cement mortar (1:6) and distempering/ white washing to match the existing surface complete all as specified & directed.
Taking down old unserviceable Empty Box/ Bus Bar Chamber/ DB’s of any capacity with MCCB's or MCB fixed on wall and making good disturbed surfaces of wall/ floor with cement plaster in cement mortar (1:6) and distempering/ white washing to match the existing surface complete all as specified & directed.
All as per Serial item No. 70.00 here in above but with One light point controlled by two 2 - way switches with cables 1.5 sq. mm size all as specified and directed.
One light point controlled by one no one way 6 Amps switch complete.
One fan point controlled by one no one way 6 Amps switch complete.
One calling bell point controlled by one no 5 Amps bell push switch complete.
One 6 Amps socket outlet point on the same board with other switches complete
One 6 Amps switch socket combination point on independent board complete
Taking down and dismantling of ceiling fan, segregation of unserviceable parts, cutting and removing of burnt out copper winding, cleaning the armature, rewinding of fan armature with appropriate gauge of super enamelled copper wire with necessary insulating materials such as vertex paper, cotton tape, PVC insulation tape, Rotter soft etc varnishing with approved grade of insulation varnish and heating up, re-assembling the fan complete with replacement of unserviceable spares parts, (spare parts will be measured & paid separately) including necessary lathe work for fixing of bush/ bearing greasing the same with approved grade of grease, making all electrical connection and supply and fixing the following items and including necessary transportion to MES workshop, for 1200/1400/1500mm sweep fan :- Notes : (i) Repairs works for spares will be measured and paid separately under respective items. (ii) Cost of split pin, lock nuts, rubber bush, capacitor clamps, screws, bolts, nuts and washers, etc if required to be fitted shall deemed to be included in the quoted rate.
S&F modular switch single pole one way, 6 Amp, AC,230 V all as specified and directed. Make : Anchor/ Crabtree/ Legrand
S&F modular bell push, 6 Amp, AC,230 V all as specified and directed. Make : Anchor/ Crabtree/ Legrand
S&F modular switch single pole one way, 16 Amp, AC,230 V all as specified and directed. Make : Anchor/ Crabtree/ Legrand
S&F modular socket 6A, AC, 230V complete all as specified and directed. Make : Anchor/ Crabtree/ Legrand
S&F modular socket 6 /16 Amp, AC, 230V complete all as specified and directed. Make : Anchor/ Crabtree/ Legrand
S&F rotary step modular electronic fan regulator (2 module) flush type AC, 230V complete all as specified & directed. Make : Anchor/ Crabtree/ Legrand
S&F white cover plate with frame, 1 module.
S&F white cover plate with frame , 2 module.
S&F white cover plate with frame, 3 module.
S&F white cover plate with frame, 4 module.
S&F white cover plate with frame , 6 module.
S&F white cover plate with frame, 8 module.
Taking out defective/ burnt out winding of exhaust fan of various make of size 200 to 300 mm sweep working on 230 to 380 volts single phace / AC, material and labour for Rewinding with supper enamelled new copper wire of apropriate Gauge including varnishing good quality varnish heating up and re assembling the fan/ testing/ transpotation/ placment of connector flexible copper wire size 23/0.0040, 3 core up to one metre complete all as specifiede and directed.
All as per Serial item No. 52.00 here-in-before but with two single core PVC insulated unsheathed multi stranded copper conductor cable (FRLSH) of size 4 Sqmm 1100 volts grade and one single core PVC insulated unsheathed multistranded copper conductor (FRLSH) of size 4 Sqmm 1100 Volts grade as earth continuity conductor (as per colour code) including PVC concealed conduit (medium grade)of suitable size with all accessories such as bend, elbow, tee etc for 15 Amps switch socket combination point on independent board complete all as specified and directed.
S&F metal flush box 1/2 moudle
S&F metal flush box 3 moudle
M&L for point wiring with two single core PVC insulated unsheathed multistranded copper conductor cable (FRLSH) of size 1.5 Sqmm 1100 volts grade with one single core PVC insulated unsheathed multistranded copper cable(FRLSH) of size 1.5 Sqmm 1100 volts grade as earth continuity conductor (as per colour code), drawn through in and including PVC concealed conduit (medium grade)of suitable size with all accessories such as bend, elbow, tee etc and making grooves in any type of brick wall/ ceiling, plastering and making good disturbed surfaces as per existing and connected to common earth dolly, sunk type metal box for housing / mounting the modular switch sockets with mounting plate / cover plate complete all as specified and directed for the following items : Make : PVC Cable - MESCAB/ KEI / RR Kable PVC Conduit/ Casing Caping - Precission /Prestoplast
One light point controlled by one no one way 6 Amps switch complete.
One fan point controlled by one no one way 6 Amps switch complete.
One calling bell point controlled by one no 5 Amps bell push switch complete.
One 6 Amps socket outlet point on the same board with other switches complete
One 6 Amps switch socket combination point on independent board complete
S&F metal flush box 4 moudle
S&F metal flush box 6/8 moudle
S&F ceiling Rose surface PVC/ polycarbonate 65 x50 mm three terminals (ISI Marked), AC, 230 Volts complete all as specified & directed. Make : Anchor / Havells Reo / Maru
S&F switch piano flush type single pole one way (ISI Marked), 6 Amp, AC,230 V all as specified and directed. Make : Anchor (Code-38014) / Havells Reo / Maru
S&F bell push flush type (ISI Marked), 6 Amp, AC, 230 V all as specified and directed. Make : Anchor / Havells Reo / Maru
S&F socket outlet flush type 2 in 1, 6A, AC, 230V complete all as specified and directed. Make : Anchor / Havells Reo / Maru
S&F switch & socket combination flush type 2 in 1, 6A, AC, 230V complete all as specified and directed. Make : Anchor / Havells Reo / Maru
S&F switch socket combination flush type 2 in 1, 6 Pin, 20/10 Amp, AC, 230V with four fixing holes complete all as specified and directed. Make : Anchor / Havells Reo / Maru
M&L for point wiring with two single core PVC insulated unsheathed multistranded copper conductor cable (FRLSH) of size 1.5 Sqmm 1100 volts grade with one single core PVC insulated unsheathed multistranded copper cable(FRLSH) of size 1.5 Sqmm 1100 volts grade as earth continuity conductor (as per colour code), drawn through in and including PVC concealed conduit (medium grade)of suitable size with all accessories such as bend, elbow, tee etc and making grooves in any type of brick wall/ ceiling, plastering and making good disturbed surfaces as per existing and connected to common earth dolly, sunk type metal box for housing / mounting the modular switch sockets with mounting plate / cover plate complete all as specified and directed for the following items :- Make : PVC Cable - MESCAB/ KEI / RR Kable PVC Conduit/ Casing Caping - Precission /Prestoplast
Supply & fixing Lamp holder PVC/ Polycarbonate insulated body with back plate for angle/ batten fittings complete.
Supply and fixing retrofit LED lamp 10 watt light complete all as specified.
Supply and fixing of surface mounted batten type, slim LED luminaires 10 W, 220 - 240 V AC, 50 Hz, IP 20 with aluminium extruded housing, polycarb
onate diffuser & end caps, minimum efficacy 100 lumens/watt with 120 degree viewing angle, CCT 6500, CRI ≥ 80, power factor ≥0.9, IP 20, surge protection 4.0 KV, THD < 20% integral electronic driver with short circuit protection and open circuit protection, surge voltage protection complete all as specified and directed. Make : Havells (Type- Endura Linear Neo)/ Philips/ Wipro/ Surya(SLE BT 10- IL)/ Jaquar (Type- Glaze)
Supply & fixing of surface mounted batten type, slim LED luminaires 20 W, 220 - 240 V AC, 50 Hz, IP 20 with aluminium extruded housing, polycarbonate diffuser & end caps, minimum efficacy 100 lumens/watt with 120 degree viewing angle, CCT 6500, CRI ≥ 80, power factor ≥0.9, IP 20, surge protection 4.0 KV, THD < 20% integral electronic driver with short circuit protection and open circuit protection, surge voltage protection complete all as specified and directed. Make : Havells (Type- Endura Linear Neo)/ Philips/ Surya(SLE BT 20- NEO MAX)/ Jaquar (Type- Glaze)
Supply of high efficacy recess mounted LED luminaires 36W, 240V AC, 2X2 tile in CRCA housing with full opal diffuser with flicker control technology to reduce harmful invisible flicker present in LED lighting sources, CCT 6500K, CRI ≥ 80, rated voltage 240V AC, power factor ≥0.95, IP 20, surge protection 2.5 KV, integral electronic driver with output short circuit protection and open circuit protection, surge voltage protection complete all as specified and directed. Make : Orient AQUA RECESS 2X2 FC - LTRAQ -36 -C -FC/ Surya(TROFFER SLE DS 36 22S XX)/ Philips/ Havells
Supply and fixing 25 Watt Highly efficient front openable IP 66 LED street light with aluminium pressure die-cast housing, toughned glass in the front and penaut lens for batwing light distribution to ensure uniform light distribution, higher spacing between poles and maintenance free-system.
Fabricate, supply & fix GI pipe bracket 25mm dia- 1.2 mtr long & 2 set of clamps made out of 30x5mm ms flat & fixed with anchor bolt suitable for 20 watt security light fitting .
M&L for LED Bulk head light of capacity 10W Pressure die cast AL housing IP 65 protected. Complete all as directed Make : Crompton of cat pt no. LBHE-10-CDL, Havell's Cat part No- HEXAFT10WLED857SSYMBOPC of crompton or euivalent make of HPL/ Philips/ Bajaj.
S & F in repairs single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB SP 20 Amps complete all as specified and directed.
S&F in repair of switch piano flush type single pole one way (ISI Marked), 6 Amp, AC,230 V all as specified and directed. Make : Anchor (Code-38014) / Havells Reo / Maru
S&F in repair of bell push flush type (ISI Marked), 6 Amp, AC,230 V all as specified and directed. Make : Anchor / Havells Reo / Maru
S&Fin repair of socket outlet flush type 2 in 1, 6A, AC, 230V complete all as specified and directed. Make : Anchor / Havells Reo / Maru
S&F in repair of switch & socket combination flush type 2 in 1, 6A, AC, 230V complete all as specified and directed. Make : Anchor / Havells Reo / Maru
S&F in repair of switch socket combination flush type 2 in 1, 6 Pin, 06/16 Amp, AC, 230V with four fixing holes complete all as specified and directed. Make : Anchor / Havells Reo / Maru
Supply and fix in repairs of DB 8 way MCB SPN double door, glazed type, IP 43 protection, Glazed door, isolated neutral bar, insulated bus bar assembly, mechanical strength of IK09, complete all as specified and directed. Make : Legrand / Indo asian / Havells or its equivalent in specified makes in CA.
Supply and fix in repairs of DB 12 way MCB SPN double door, glazed type, IP 43 protection, Glazed door, isolated neutral bar,insulated bus bar assembly, mechanical strength of IK09 complete all as specified and directed. Make : Legrand / Indo asian / Havells or its equivalent in specified makes in CA.
Supply & fix in repair of MCB TPN 63 Amps 'C' Series 10 KA, 415 volts complete all as specified and directed.
Supply and fix in repairs of DB 4 way MCB TPN double door, glazed type, IP 43 protection,Glazed door, isolated neutral bar, insulated bus bar assembly, mechanical strength of IK09 complete all as specified and directed. Make : Legrand / Indo asian / Havells or its equivalent in specified makes in CA.
Supply & fix in repair of MCBs single pole (SPN) 6 to 32 Amps with 10 KA breaking capacity of 'C' series in distribution boards conforming to IS/IEC 60898-1 (ISI marked) complete all as specified and directed.
Supply & fix in repair of MCBs single pole (SP) 6 to 32 Amps with 10 KA breaking capacity of 'C' series in distribution boards conforming to IS/IEC 60898-1 (ISI marked) complete all as specified and directed.
S&F in Replacement of existing sub main wiring with two run of single core (FRLS) PVC insulated and unsheathed cable with copper conductor (Multi strand) having nominal area 4.0 Sqmm drawing into and including PVC casing and caping of adequate size and making electric connections including one run (FRLS) PVC insulated single core copper conductor cable 4.0 Sqmm as a earth continuity conductor (green colour) in and including in non metallic rigid PVC conduit, including cutting chases in brick wall, replastering and making good to match the existing specifications complete all as specified and directed by Engineer-in-Charge. Make : KEI/ Havells/ Anchor/ polycab. Note : (i) Rate quoted shall deemed to be included chases of sinking for boxes cutting and making holes in wall/floor for passing in or through conduit (ii) Two run of 4.00 sqmm single core (FRLS) PVC insulated copper conductor cable one run of 4.0 sqmm copper conductor cable (FRLS) as a earth lead and one run of PVC conduit of suitable size will be measured as a one unit.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
Tndr8512.pdf
Tender Documents • 1.07 MB
BOQ_827980.xls
BOQ • 0.88 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .