| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.1 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹45.3 L+₹36,334 (0.81%)Rejected-Finance FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L2 | Rejected-Finance BEING L2 REJECTED | |
| 3 | L3₹46.6 L+₹1.7 L (3.69%)Rejected-Finance | L3 | Rejected-Finance BEING L3 REJECTED | |
| 4 | L4₹47.1 L+₹2.1 L (4.78%)Rejected-Finance | L4 | Rejected-Finance BEING L4 REJECTED | |
| 5 | L5₹49.1 L+₹4.2 L (9.24%)Rejected-Finance | L5 | Rejected-Finance BEING L5 REJECTED |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
23 Sept 2023, 6:00 pmClosed
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
REPAIR REPLACEMENT OF INTERNAL ELECTRIFICATION INCLUDING REPLACEMENT OF LIGHT FITTINGS REPAIR REWINDING OF CEILING FANS EXHAUST FANS GEYSERS AT NAVY NAGAR NAD COLONY NOFRA OFFRS AND BAZAR AREA MD ACCN AND METER PANELS MS SHEET METAL ENCLOSURE SUBMAIN
2023_MES_616200_1
8709/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NW KARANJA
D and above b i
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹94,000
Yes
26 Oct 2023
29 Aug 2023
26 Sept 2023
29 Aug 2023
23 Sept 2023
11 Sept 2023
Amount
Notes : (i) The work consists of 01 job as under:- JOB (A) : TPP 23-24 Ser No. 55 (ii) Please refer schedule 'A' notes before quoting the tender. (iii) Amount of Schedule of Credit shall be deducted off line by the department. ITEMS FOR JOB 'A'
Taking down carefully copper /aluminium point wiring (light, fan socket or power) through stove enamelled steel conduit/pvc conduits including complete fittings such as switches, ceiling roses, pendants, regulators, sockets,, switch sockets, electrical fittings etc removing and making good disturbed surfaces of walls/ceiling etc, complete all as specified and directed.
Taking down carefully by unscrewing from boards/outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store complete all as specified and directed.(To be measured only when found serviceable in all respects complete for reuse)
M&L for Point wiring with single core 1100 volts grade 1.5 sqmm size PVC FRLS insulated unsheathed stranded copper conductor cable using color code drawn through PVC conceiled conduit with all accessories for modular fitting such as cover plates ,frame plates,metal boxes of adequate size and including 1.5Sqmm PVC insulated unsheathed copper conductor cable for continous earth conductor (using green colour) to common earth and connecting to earth dolly complete all as specified and directed for the following
One light /fan/ call bell point controlled by one switch
One 5 pin socket outlet 5 Amps on independent board
One 5 pin socket outlet 5 Amps on same board
One light point controlled by 2 way switch SP, 5 Amp, 240 Volts
All as per BOQ item No 1.03 above but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FRLS PVC insulated sheathed cable with FRLS PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent board complete all as specified and directed.
M&L for point wiring with 1.5 sqmm (nominal area) PVC insulated and unsheathed multistranded FRLS copper conductor cable (using colour code as per IS), 1100 volts grade drawn through and including surface PVC casing caping (ISI marked) and shall be of one of the make M/s Precision/ M/s Asian/M/s Prestoplast/M/s BEC with all accessories including surface/ concealed sheet steel terminal/CI box with 3mm thick hylam/masonite sheet top including 1.5 sqmm size PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor (using green colour) to common earth and connecting to earth dolly, complete all as specified and directed.
All as per BOQ item no 1.09 but One light point controlled by 2 way switch SP, 5 Amp, 240 Volts complete all as specified and directed.
All as per BOQ item no 1.09 above but one 5 amp socket point on same board complete all as specified and directed.
All as per BOQ item no 1.09 above but one 5 amp multi socket indepenedent complete all as specified and directed.
All as per BOQ item no 1.08 hereinbefore, but using 2.5 sqmm ( nominal area) multistranded FRLS copper conductor cable/wire & 2.5 sqmm size PVC insulated unsheathed copper conductor cable for earth continuity ( green colour) for one 5 pin socket outlet 5 / 15 Amp multi purpose independent point controlled by 15 Amp switch, SP one way, 240 Volts & Socket, complete all as specified and directed.
All as per BOQ item no 1.09 hereinbefore, but using 4 sqmm (nominal area) multistranded copper conductor cable/wire for one 5/15 Amp socket point controlled by 15 Amp switch, SP one way 240 Volts & Socket, complete all as specified and directed.
S&F switch piano flush button single pole one way, 6 Amp complete all as specified and directed.
S&F Switch socket outlet 2 in 1, 3 pin, 6 Amp flush type complete all as specified and directed
S&F Socket outlet 2 in 1, 3 pin, 6 Amp flush type complete all as specified and directed
S&F Switch bell push flush type 5 Amp all as per complete all as specified and directed
S&F Switch socket outlet 15 Amp, 5-in-1, controlled by one switch complete all as specified and directed
S&F Switch flush button, single pole two way, 6 Amp complete all as specified and directed
S&F Socket type EME fan 5 step regulator for ceiling fan of suitable size, complete all as specified and directed
S&F switch type EME fan 5 step regulator for ceiling fan of suitable size, complete all as specified and directed
S&F Lamp holder/angle holder insulated body with black/white plate for batten fittings complete all as specified and directed
S&F in repairs modular step type fan regulator complete all as specified and directed
S&F in repairs modular switch 1 module 6 amp one way complete all as specified and directed
S&F in repairs modular switch 1 module 16 amp one way complete all as specified and directed
S&F in repairs modular socket 2 module universal type 5/6 amp one way complete all as specified and directed
S&F in repairs modular socket 2 module universal type 15/16 amp one way complete all as specified and directed
S&F in repairs modular bell push 6A 1 module complete all as specified and directed
S&F in repairs Bell buzzer, ding dong 230v 50hz single pole complete all as specified and directed
S&F in repairs modular cover plates with frame up to 4 module as per site requirements apart from the rates included in the point wiring for cover plates and metal flush boxes which is catered for new point wiring in item no 1.03 above complete all as specified and directed. NOTE-Cover plates considered in this item only for the maintanance of switches of existing modular fitting qtrs
S&F in repairs modular cover plates with frame 6 to 8 module as per site requirements apart from the rates included in the point wiring for cover plates and metal flush boxes which is catered for new point wiring in item no 1.03 above complete all as specified and directed . NOTE-Cover plates considered in this item only for the maintanance of switches of existing modular fitting qtrs
S&F in repairs modular metal flush box as per site requirements 6 to 8 modules complete all as specified and directed. NOTE-metal flush boxes considered in this item only for the maintanance of switches of existing modular fitting qtrs
M&L for wiring for circuits/sub main wiring with FRLS PVC insulate sheathed 2 x 6 sqmm stranded copper conductor cable 1100 volts grade heavy duty drawn into PVC conduit with 6 sqmm PVC insulated green copper cable for continues earth PVC pipe not less than 20 mm dia with all accessories in replacement complete all as specified and directed
M&L for wiring for circuits/sub main wiring with FRLS PVC insulate sheathed 2 x 4 sqmm stranded copper conductor cable 1100 volts grade heavy duty drawn into PVC conduit with 4 sqmm PVC insulated green copper cable for continues earth PVC pipe not less than 20 mm dia with all accessories in replacement complete all as specified and directed
M & L for submain wiring with 4 runs of single core 6 sqmm PVC insultaed, unsheathed multi stranded copper conductor cable, 1100 Volts grade conforming to IS-694 1990 with ISI mark, drawn through PVC casing capping 25 mm size including one run of 6 Sqmm PVC insulted multistanded copper conductor cable, 1100 Volts grade conforming to IS -694, 1990 green colour for earth continuity and connecting up to common earth dolly in replacement complete all as specified and directed. Note:- Four runs of 6 sqmm cable, one run of 6 sqmm earth wire will be measured as one running metre
M & L for submain wiring with 4 runs of single core 16 sqmm PVC insultaed, unsheathed multi stranded copper conductor cable, 1100 Volts grade conforming to IS-694 1990 with ISI mark, drawn through PVC conduit of suitable size including one run of 16 Sqmm PVC insulted multistanded copper conductor cable, 1100 Volts grade conforming to IS -694, 1990 green colour for earth continuity and connecting up to common earth dolly in replacement complete all as specified and directed. Note:- Four runs of 16 sqmm cable, one run of 16 sqmm earth wire will be measured as one running metre
S&F in repairs LED building security light fitting with suitable size bracket/angle to fit security light of 60w IP 66 protection LED complete all as specified and directed
S&F in repairs LED batten with sensor 18W LED tube light having function of 25% brightness without motion and 100% brightness on detection of motion in wall/surface connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as specified and directed
S&F in repairs LED batten with 22W LED tube light in wall/surface connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as specified and directed
S&F in repairs LED batten with 24W LED tube light in wall/surface connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as directed and specified
S&F in repairs double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 12 way double door open able, complete all as specified and directed
S&F in repairs double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 8 way double door open able, complete all as specified and directed
S&F in repairs double door MCCB DB VTPN 4 way made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, with thimble flame retardant copper conductors and 250 Amps rated bus bar double door open able complete all as specified and directed
S&F in repairs 6 to 32 AMP MCB single pole 240 V 10 KA (C-Series) complete all as specified and directed.
S&F in repairs 40 AMP MCB DP 240 V 10 KA (C-Series) complete all as specified and directed.
S&F in repairs LED recess mounted 2x2 luminarie 36w fitting complete all as specified and directed
S&F in repairs LED Bulk head fittings 9/10W luminaire including LED light driver holder connecting up with three core flexible copper conductor calbe of suitable size complete with all acccessories complete all as specified and directed
S&F in repairs LED tube rod 20 watt change with existing 36 watt tube rod complete all as specified and directed
S&F in repairs Batten MS suitable for 18/22/24W LED rod with accessories including suitable 1.5 sqmm 2 core wire for connecting with ceiling rose complete all as specified and directed.
S&F in repairs LED batten 10w, 2 feet with LED tube light in wall/surface connecting with all required accessories like flexible cable from ceiling rose etc complete all as specified and directed
S&F in repairs LED batten with sensor 9/10W LED tube light, 2 feet having function of 25% brightness without motion and 100% brightness on detection of motion in wall/surface connecting with all required accessories like flexible cable from ceiling rose etc complete all as specified and directed
S&F in repairs MCCB 4 pole, thermal magnetic release range 100 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed
S&F in repairs MCCB 4 pole, thermal magnetic release range 125 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed
S&F in repairs MCCB 4 pole, thermal magnetic release range 63 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed
Taking out cover plate of bus conductor duct of multistoreyied building,inspection cleaning, servicing including replacement of rusted nuts bolts,insulators etc ,cutting of damage end of outgoing cables and reconnection using proper size of cable lugs and preparation of old painted surface by scrapping and brooming down and material and labour for two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for checking & repairing of DBs/ meter panel board/Circuits/submain wiring and other connected work including rectification of faults complete all as specified and directed Note : Each job consist of minimum 10 complaints from various locations to be rectified.
S&F in repairs wall light fitting of (Make Havells ct no-LHJCO2108499 or equivalent approved by GE) with & including 10w LED lamp complete all as specified and directed
S&F in repairs epoxy coated connector of capacity 100A post type for bus bar trunking system complete all as specified and directed
Taking out two wire from meter and bus bar/MCB SPN/SP with keeping in veiw safety and replaced with 2 run of 10 sqmm wire of meter with suitable size of cable lugs both end and reconnection with meter and bus bar/MCB SPN/SP complete all as specified and directed. NOTE : Rate of lugs will deemed to be included in quoted rate by the contractor.
S&F in repair/replacement of old existing sunken/terminal box of size 10x10cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls complete all as specified and directed
S&F in repair/replacement of old existing sunken/terminal box of size 15x7.5cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls complete all as specified and directed
S&F in repair/replacement of old existing sunken/terminal box of size 20x15cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls complete all as specified and directed
S&F in repair/replacement of old existing sunken/terminal box of size 20x25cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls complete all as specified and directed
S&F in repairs emergency bulb LED 10W, 230V, 50Hz, with 4 hour backup complete all as specified and directed.
S&F in repairs round recessed 15W/18W warm white LED downlight dimmable with high lumen 230V, compatible with Legrand Dimmer as per sample complete all as specified and directed
S&F in repairs RCCBs 63 Amps double pole 100mA breaking capacity complete all as specified and directed.
S&F in repairs LED driver for 36 watt 2x2 recessed mounted LED panel suitable for VDG 36100P complete all as specified and directed.
S&F in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm 2 core saddle on wall to fix bldg security light/ flood light etc, complete all as specified and directed.
S&F in repairs LED 100 watt Highbay luminaire complete fixing arrangement fixed on ceiling with anchor incuding hanging arrangement, connecting up to 3 core multistranded copper conductor complete all as specified and directed
S&F Meter Box consisting space to fix MCCB as Incomer and 09 nos meter and providing 09 nos MCB RCBO 40 Amps 100 mA, METER box double door fixed type wall mounted CRCA approved FACTROY MADE, 2 mm thick sheet enclousure. The rates including taking down old meter and connecting in new panel with required wires with out any extra cost complete all as specified and directed.The panel should cosists of the following :- INCOMING (1) MCCB 100 AMP 4 P 16 kA thermal magnetic based with o/c, s/c protection & ROH - 01 nos (2) Indicating lamps RYB-03 nos. OUT GOING :(1) 40 amp MCB RCBO 100 mA -09 nos. (2) Space for refixing existing electrical meter - 09 nos NOTE - Contractor should visit the site and to prepare panel as per size required to fit in below stair case complete all as specified and directed by Engr-in-charge
M.K Enterprises
ELECTRO ASSOCIATES
Dinesh Enterprises
PRASHANT ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .