Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.2 LAccepted-AOC NEAR PAYAL CINEMA P O SEVOKE ROAD SILIGURI 734 001 | DARJEELING | WEST BENGAL | 734001 | ₹40.2 L Quoted ₹41.1 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹49.4 LRejected-Finance JYOTIRMAY COLONY WARD NO 32 P O SILIGURI BAZAR P S BHAKTINAGAR SILIGURI JALPAIGURI 734005 | SILIGURI | JALPAIGURI | WEST BENGAL | 734005 | ₹49.4 L | L2 | Rejected-Finance Not Lowest Bidder |
| 3 | L3₹49.6 LRejected-Finance 45 9 6 BAGHAJATIN COLONY PO PRADHAN NAGAR SILIGURI 734 403 DIST DARJEELING WB | 734403 | ₹49.6 L | L3 | Rejected-Finance Not Lowest Bidder |
| 4 | L4₹49.9 LRejected-Finance A 4 VIVEKANANDA SUPER MARKET 2ND FLOOR HILL CART ROAD SILIGURI 734 001 DIST DARJEELING W B | JALPAIGURI | WEST BENGAL | 734001 | ₹49.9 L | L4 | Rejected-Finance Not Lowest Bidder |
| 5 | L5₹49.9 LRejected-Finance | ₹49.9 L | L5 | Rejected-Finance Not Lowest Bidder |
| Sl No | Description | Qty | Unit | MS ORIENT ENGINEERING WORKS L9 | M/S DAWN ELECTRICAL INDUSTRIES L6 | KARMIBRINDA L4 | M/S GLORIOUS CONSTRUCTION L8 | Janata Enterprises L1 | D K SARKAR L7 | Jagatbandhu Enterprises L3 | M/S. KARMAKAR ENGINEERING COMPANY L2 | PAUL CONSTRUCTION L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in Soft/ Loose soil complete all as specified and directed. | 1,000 | Sqm | 28 ₹28,000 | 30 ₹30,000 | 22 ₹22,000 | 29 ₹29,000 | 18 ₹18,000 | 22 ₹22,000 | 27 ₹27,000 | 28 ₹28,000 | 30 ₹30,000 |
| 2.00 | Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 Sqm on plan and not exceeding 1.5 m in depth getting out in soft / loose soil complete all as specified and directed. | 415 | Cum | 192 ₹79,680 | 200 ₹83,000 | 190 ₹78,850 | 195 ₹80,925 | 190 ₹78,850 | 205 ₹85,075 | 195 ₹80,925 | 190 ₹78,850 | 200 ₹83,000 |
| 3.00 | Excavation in trenches not exc. 1.50 m wide and exc. 1.50 m in depth but not exc. 3.00 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 Sqm on plan and not exceeding 1.5 m in depth getting out in soft / loose soil complete all as specified and directed. | 0.5 | Cum | 240 ₹120 | 250 ₹125 | 240 ₹120 | 248 ₹124 | 240 ₹120 | 253 ₹126.50 | 250 ₹125 | 240 ₹120 | 260 ₹130 |
| 4.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed. | 235 | Cum | 95 ₹22,325 | 100 ₹23,500 | 98 ₹23,030 | 96 ₹22,560 | 94 ₹22,090 | 90 ₹21,150 | 95 ₹22,325 | 94 ₹22,090 | 92 ₹21,620 |
| 5.00 | M&L for sand cushioning to under ground cable using locally available fine clean dry river sand over,under ground UG cable laid in treches and gently punning to cushioning to cable complete all as directed by Engineer-in-Charge. Note : For the purpose of payment only punned thickness will be measured. | 120 | Cum | 1,385 ₹1.7 L | 1,390 ₹1.7 L | 980 ₹1.2 L | 1,395 ₹1.7 L | 925 ₹1.1 L | 1,425 ₹1.7 L | 1,450 ₹1.7 L | 1,380 ₹1.7 L | 1,370 ₹1.6 L |
| 6.00 | Removing Excavated soils not exc 50 M and depositing where directed at a level not exc1.5 M above the starting point complete all as specified and directed. | 140 | Cum | 22 ₹3,080 | 25 ₹3,500 | 135 ₹18,900 | 22 ₹3,080 | 110 ₹15,400 | 18 ₹2,520 | 22 ₹3,080 | 21 ₹2,940 | 20 ₹2,800 |
| 7.00 | M & L for Hardcore of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed. | 25 | Cum | 2,550 ₹63,750 | 2,600 ₹65,000 | 1,750 ₹43,750 | 2,650 ₹66,250 | 1,390 ₹34,750 | 2,500 ₹62,500 | 2,600 ₹65,000 | 2,550 ₹63,750 | 2,500 ₹62,500 |
| 8.00 | M&L PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation of pole/strut etc including necessary form work complete all as specified and directed. | 1 | Cum | 4,650 ₹4,650 | 4,700 ₹4,700 | 4,900 ₹4,900 | 4,800 ₹4,800 | 3,950 ₹3,950 | 4,500 ₹4,500 | 4,760 ₹4,760 | 4,650 ₹4,650 | 4,600 ₹4,600 |
| 9.00 | M&L for Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations of pole etc complete all as specified and directed. | 10 | Cum | 4,500 ₹45,000 | 4,500 ₹45,000 | 4,100 ₹41,000 | 4,560 ₹45,600 | 3,150 ₹31,500 | 4,700 ₹47,000 | 4,600 ₹46,000 | 4,450 ₹44,500 | 4,400 ₹44,000 |
| 10.00 | M&L PCC 1:2:4 type B-1 (using 12.5 mm graded crushed stone aggregate) as in copings, bed plates, bed block for holdfasts, filling in pressed steel door frames, benching, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating and including necessary formwork complete all as specified and directed. | 0.2 | Cum | 6,550 ₹1,310 | 6,700 ₹1,340 | 6,525 ₹1,305 | 6,650 ₹1,330 | 4,220 ₹844 | 6,000 ₹1,200 | 6,700 ₹1,340 | 6,550 ₹1,310 | 6,500 ₹1,300 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
21 Oct 2025, 6:00 pmClosed
Garrison Engineer Sukna
Garrison Engineer Sukna, Post-Simulbari, Dist-Darjeeling, WB-734009
REPAIR AND REPLACEMENT OF CERTAIN LT PANEL BOARD UG CABLE FEEDAR PILLAR BOX AND MCCBS AND ALLIED WORKS AT CERTAIN MES INSTALLATION OF MIL STN SUKNA UNDER GE SUKNA
2025_MES_732046_1
GE Sukna/8911
Open Tender
Civil Works
270 days
SUKNA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SUKNA
₹90,000
17 Jan 2026
26 Sept 2025
23 Oct 2025
27 Sept 2025
21 Oct 2025
13 Oct 2025
27 Sept 2025 - 21 Oct 2025
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in Soft/ Loose soil complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 Sqm on plan and not exceeding 1.5 m in depth getting out in soft / loose soil complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and exc. 1.50 m in depth but not exc. 3.00 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 Sqm on plan and not exceeding 1.5 m in depth getting out in soft / loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed.
M&L for sand cushioning to under ground cable using locally available fine clean dry river sand over,under ground UG cable laid in treches and gently punning to cushioning to cable complete all as directed by Engineer-in-Charge. Note : For the purpose of payment only punned thickness will be measured.
Removing Excavated soils not exc 50 M and depositing where directed at a level not exc1.5 M above the starting point complete all as specified and directed.
M & L for Hardcore of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed.
M&L PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation of pole/strut etc including necessary form work complete all as specified and directed.
M&L for Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations of pole etc complete all as specified and directed.
M&L PCC 1:2:4 type B-1 (using 12.5 mm graded crushed stone aggregate) as in copings, bed plates, bed block for holdfasts, filling in pressed steel door frames, benching, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating and including necessary formwork complete all as specified and directed.
M&L for 25 mm thick Jallies or louvers Precast Reinforced Cement concrete 1:2:4 type B0 (Using 12.5 mm graded stone aggregate) in including all mouldings set jointed in CM 1:4 but excluding frame including demolition of existing cement concrete complete all as specified and directed.
Taking down chowkhats or frames area not exc. 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkhats or frames area exc. 1.50 Sqm but not exc. 4.00 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
S & F 30 mm thick (style thickness) factory made solid panel PVC shutter consisting of frame made out of mild steel tubes for top and bottom rails, mild steel frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheets beading and joined together with solvent cement as per specification and drawing given on MES schedule Part – II (2010) complete all as specified and directed.
S & F factory made Solid PVC door frame of size 50 mm X 47 mm made out of 5 mm plain coloured PVC sheet reinforced with mild steel square tube as per specification and drawing given on MES schedule Part – II (2010) complete all as specified and directed.
S&F 5 mm thick PVC insulation panel with EPS stuck to 1 mm plain PVC sheet suitably placed in false ceiling including GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (n. exc. 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel at 457 mm centre to centre and necessary hangers 6 mm dia GI fixed to roof and including dismantling complete all as specified and directed.
S&F 150 mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed.
S&F 100 mm butt hinges, extruded aluminium alloy with galvanized mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed.
S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and as directed.
M&L for mild steel work as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; handmade sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
S & F Steel door with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S & F Steel windows with side hung shutters including box type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dove-tailed or welded complete all as specified and directed.
S&F steel ventilator with top hung shutter and including hinges steel peg stay complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm TCT (total coated thickness) of any colour having tensile strength of 550 Mpa as in roof covering cladding to wall etc, fixed with self tapping screws complete all as specified and directed.
S&F 4 mm thick E-board (designer pattern) celing of size 60x60 cm, fixed or laid / inserted to aluminium framework with screws in false ceiling (flat or sloping) of grid size 605 x 605 mm and including anodised aluminium snap grid frame work for false ceiling hanging from structural steel / scantling with 6 mm GI wire complete all as specified and directed.
M&L 75 mm thick, PCC 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in sub floor, sub base of floor, etc complete all as specified and directed.
M& L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand.
S & F Sheet glass 3.0 mm thick, ordinary quality and glazing with oil putty or wooden beads not exceeding 0.5 Sqm in each pane glazed with putty or fixed with beads complete all as specified and directed.
S & F 4 mm thick Frosted glass, ordinary type and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane fixed to steel frame including steel pin complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided including padding concrete on roof all as specified and directed.
Dismantling of corrugated or semi corrugated Asbestos Cement (AC) sheets in roof covering complete all as specified and directed.
Dismantling wall and ceiling boards, partitions of any description or in any position (fibre, pulp, insulation etc.) any thickness, or insulation boards/ slabs/ blankets of any thickness including cover fillets complete all as specified and directed.
M&L for roof treatment in order of precedence as given below complete all as specified and as directed:- (i) Taking out of existing water proofing treatment and including padding, cleaning the surface using wire brush, brooming down and washing down with water to remove dust etc, and brushing with neat cement slurry @ 3.00 kg of cement per Sqm. (ii) 15 mm thick screed bed in CM 1:4 on surface. (iii) Cleaning of plastered surface and applying one coat of bituminous primer @ 0.40 Ltr / Sqm. (iv) Supply and laying 3 mm (Minimum) thick APP based polymeric membrane of approved manufacturer with weight not less than 3.60 Kg per Sqm, reinforced with non-woven polyester fabric weight not less than 150 gms per Sqm. Polymeric membrane shall be taken to a height of 30 cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (Cont.)
(v) Applying one coat of water proofing paint with aluminium finish over APP as per manufacturer's instruction. Note :- (a) Bituminous primer shall be "ShaliTex Primer" manufactured by M/s STP Ltd or equivalent in M/s Sika India Pvt Ltd or M/s Fosroc Chemicals or M/s Hindcon chemicals limited or M/s IWL India Limited (b) Laying APP based polymeric membrane shall be done by torch on method as per manufactures instructions. (c) A minimum overlap of 100 mm and 75 mm should be made at the end and sides of the polymeric membrane respectively and all overlaps and joints shall be sealed as per manufacturers instruction.
Supply and fixing in repair of Ultra Heavy duty capacitor box oil filled type of capacity 10 KVAr, 440 volt 3 phase incl making connection to existing MCCB/Contactors incl taking down old unsv complete all as specified & as diretced.
Supply and fixing in repair of Ultra Heavy duty capacitor box oil filled type of capacity 15 KVAr, 440 volt 3 phase incl making connection to existing MCCB/Contactors incl taking down old unsv complete all as specified & as diretced.
S&F MCCB 4P 200 Amps 415V ,50 Hz ,breaking capacity 36 KA, type DU 250 C, Including dismantling/ taking down unsvericeable one complete all as specified and directed.
S&F MCCB 4P 250 Amps 415V ,50 Hz ,breaking capacity 36 KA, type DU 250 C, Including dismantling/ taking down unsvericeable one complete all as specified and directed.
S&F MCCB 4P 400 Amps 415V ,50 Hz ,breaking capacity 36 KA, type DU 250 C, Including dismantling/ taking down unsvericeable one complete all as specified and directed.
Supply & fixing in repair of ACB 4 Pole, 415 V, 50kA with Thermal Magnetic Release (Manual Drawout type) of capacity 630 Amps incl taking down old unsv complete all as specified and as directed.
Supply & fixing in repair of ACB 4 Pole, 415 V, 50kA with Thermal Magnetic Release (Manual Drawout type) of capacity 800 Amps incl taking down old unsv complete all as specified and as directed.
M&L in replacements earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead of GI strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No. 3 connected to earthing test point and including dismantling complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 15 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
Supply and fixing earthing continuty conductor or main earthing lead fixed to pole or burried in ground or at any other situation for loop earthing extra as required of GI strip 25x4 mm complete all as specified and directed
S & F of Pole mounted Junction box with terminals of size 182 x 180 x 111 mm, made of high quality thermoplastic polycarbonate, dust & jet water proof, chemical, acid corrision, impact IK-09, insulated & shock proof IP 66, grey RAL 7035 color with internaly embedded gasket (PUR) , along with cover and metric knockout all sides including back of the base must including terminals 4Nos including fixing arrangement with MS flat of size 40X4mm , nuts , bolt and washers and MCB SP 6-32 Amps 01 No including taking down old unsv complete all as specified and as directed.
Supply and fixing of Nature Switch Smart Sensor based automatic street light Control Panel with suitable enough to take 3-Phase load of 12 KW with 03 Nos I/O MCBs of 32 Amps & 03 Nos contactors of 32 Amps & circuit wiring (copper) of 10 sqmm.The infrared sensing should be maintenance free in design and its operation should be based on Natural Light Lux level (Switching ON less than 60 Lux & switching off more than 10 Lux).The sensor along with suitable power contactors and I/O MCBs should be enclosed in a pole/wall mountable rust proof,electric shock proof,termite proof and FR grade thermoplastic enclosure (with HINGED LED) conforming to IP66 protection class 2 complete all as specified & as directed.Make :-- SWADEEP SUGAM 66 12kW3P or its equivalent in Legrand/Havells
S&F in repair of Street Light Timer switch with 24 Hour daily setting, protected with IP-53 box, 230 volt,50Hz AC,ON-AUTO-OFF on front panel, one segment of 15 Min with accuracy of +/- 5 mins, complete all as specified and directed.
M&L for painting steel tubular poles 9 mtr height with one coat of aluminium paint from bottom to top including cross arms, GI brackets etc after cleaning and preparing the surface and marking alternate yellow and black strips 30 cm height total 5 Nos with two coats of synthetic enamel point over a coat of primer complete all as specified and as directed.
M&L for painting of PCC poles 9 mtr height with one coat of aluminium paint from bottom to top including cross arms,GI brackets etc after cleaning and preparing the surface and marking alternate yellow and black strips 30 cm height total 5 Nos with two coats of synthetic enamel point over a coat of primer complete all as specified and as directed.
M&L for brick protection cover of size 230x115x75 mm to LT underground cables with sub class 'B' over burnt brick, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and directed.
Boring/Drilling (horizontally) manually under 2m deep in soil below existing road suitable for passing GI tubing of 40 to 80 mm bore complete all as specified and directed.
Supply and fixing of GI tubing light grade 40mm dia for protection of cable on pole , under road crossing or across drain , along electric pole or floor / wall including taking down old unsv complete all as specified and directed.
Supply and fixing in repair of GI tubing light grade 50mm dia for protection of cable on pole , under road crossing or across drain , along electric pole or floor / wall including taking down old unsv complete all as specified and directed.
Supply and fixing in repair of GI tubing light grade 80mm dia for protection of cable on pole , under road crossing or across drain , along electric pole or floor / wall including taking down old unsv complete all as specified and directed.
Supply, laying testing and commissoning in replacement of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) LT Cable with stranded aluminium conductor 1100 volts grade of size 16 sqmm 4 core including taking down old unsv complete all as specified and directed.
Supply, laying testing and commissoning in replacement of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) LT Cable with stranded aluminium conductor 1100 volts grade of size 25 sqmm 4 core including taking down old unsv complete all as specified and directed.
Supply, laying testing and commissoning in replacement of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) LT Cable with stranded aluminium conductor 1100 volts grade of size 50 sqmm 3.5 core including taking down old unsv complete all as specified and directed.
Supply, laying testing and commissoning in replacement of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) LT Cable with stranded aluminium conductor 1100 volts grade of size 70 sqmm 3.50 core including taking down old unsv complete all as specified and directed.
Supply, laying testing and commissoning in replacement of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) LT Cable with stranded aluminium conductor 1100 volts grade of size 120 sqmm 3.50 core including taking down old unsv complete all as specified and directed.
Supply, laying testing and commissoning in replacement of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) LT Cable with stranded aluminium conductor 1100 volts grade of size 150 sqmm 3.50 core including taking down old unsv complete all as specified and directed.
Supply, laying testing and commissoning in replacement of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) LT Cable with stranded aluminium conductor 1100 volts grade of size 300 sqmm 3.50 core including taking down old unsv complete all as specified and directed.
Supply, transportation, fixing and erection of steel tubular sewaged pole 9 mtr long complete with MS base plate ,finial taper plug nut bolts,screws as specified type 410 SP-31 as per relevant IS specification including two coats of aluminium paint over a coat of red oxide primer and including making alternate red and black strips 30 cm height (Total 5 Nos ) and removing the old U/S one complete all as specified and directed. Note :- (Excavation and PCC will be measured and paid seprately.)
Supply, transportation, fixing and erection of steel tubular sewaged pole 11 mtr long complete with MS base plate ,finial taper plug nut bolts,screws as specified type 410 SP-31 as per relevant IS specification including two coats of aluminium paint over a coat of red oxide primer and including making alternate red and black strips 30 cm height (Total 5 Nos ) and removing the old U/S one complete all as specified and directed. Note :- (Excavation and PCC will be measured and paid seprately.)
Supply and fixing in repair Switch air break, gang operated triple pole mechanically operated mounted on with 9 insulator and steel frame with operating mechanism working from ground level current rating upto 400A, 11000 V grade having nine insulators, vertical type including dismantling of existing air break gang operated switch and removal the same from site complete all as specified and directed.
Supply and fixing in repair expulsion drop out fuse carrier assembly outdoor type 400 Amps capacity including fuse element up to 60 Amps and insulator suitable for HT 11 KV complete and dismantling of existing fuse carrier assembly and removal the same from site complete all as specified and as directed.
Dehydration of transformer oil (mounted on poles/platform etc) with the help of filtering and drying plant by mechanical machines of suitable capacity to achieve dielectric strength of 50 KV at the gap of 2.5 mm and refilling the same all as specified and directed by Engineer-in-Charge.Note:-(a) Dehydration plant to be brought at site by the contractor. (b)Dehydration and filteration to be carried out when the transformer is on load at site and rate quoted shall deemed to be included the cost of arrangement of plant by the contractor and its transportation at site complete all as specified and directed.
Supply and topping up / filling of fresh transformer oil conforming to ISD-335/BS of dielectric strength 50 KV at the gap of 2.5 mm minimum for transformer complete all as specified and directed by Engineer-in-charge.
Matrerial & Labour for Painting of Transformer complete with conservator & fins of capacity 100 to 400 KVA , 11/.433 KV out door / in door type with two coats of synthetic enamelled gray spray painting including preparation of old surfaces and writing SM/MES No complete all as specified and directed by Engr -in charge.
Matrerial & Labour for Painting of Transformer complete with conservator & fins of capacity 500 to 750 KVA , 11/.433 KV out door / in door type with two coats of synthetic enamelled gray spray painting including preparation of old surfaces and writing SM/MES No complete all as specified and directed by Engr -in charge.
Repair / servicing to gang operating devices 11000 volts up to 400 amps including greasing all the moving parts and applying white petroleum jelly at the contact points including dismantling and replacing all the un-serviceable parts/spares all as directed. Note :- All the spares replaced will be measured and paid separately under respective items of Schedule 'A'.
Dismantling of steel poles/struts any size embedded in concrete including demolition of concrete, etc and removing unserviceable materials from site of work complete all as directed by Engr-in-charge.
Supply & fixing copper alloy moving contact blades and taking down unserviceable complete all as specified and directed by Engineer-in- Charge.
Supply & Fixing copper alloy contact jaw and taking down unserviceable complete all as specified and directed by Engineer-in- Charge.
Supply & fixing Tinned copper flexible jumper and taking down unserviceable complete all as specified and directed by Engineer-in- Charge.
M&L in repairs Jumper connection between OH line to GOD and GOD to drop out fuses with ACSR conductor 6/1X3.35 mm (rabbit) not exe. 2 mtr long including necessary lugs where ever required/aluminum heavy duty PG clamps contact all as directed after removing the old jumpers including PVC sleeve not more than 1.70 Rm complete all as specified and directed.
M& L for on site repair of front and rear doors LT Panel of size 500mm x 500mmx500mm including welding of butt hinges 06 Nos on front side and as per requirement on back side, aldrop latches on front and rear side,spray painting with synthetic enamel paint (one coat) complete all as specified and as directed.
M& L for on site repair of front and rear doors LT Panel of size 1000mm x 800mmx500mm including welding of butt hinges 06 Nos on front side and as per requirement on back side, aldrop latches on front and rear side,spray painting with synthetic enamel paint (one coat) complete all as specified and as directed
M& L for on site repair of front and rear doors LT Panel of size 1200mm x 800mmx500mm including welding of butt hinges 06 Nos on front side and as per requirement on back side, aldrop latches on front and rear side,spray painting with synthetic enamel paint (one coat) complete all as specified and as directed
M& L for on site repair of front and rear doors LT Panel of size 1500mm x 1000mmx500mm including welding of butt hinges 06 Nos on front side and as per requirement on back side, aldrop latches on front and rear side,spray painting with synthetic enamel paint (one coat) complete all as specified and as directed
M& L for on site repair of front and rear doors LT Panel of size 2000mm x 1000mmx500mm including welding of butt hinges 06 Nos on front side and as per requirement on back side, aldrop latches on front and rear side,spray painting with synthetic enamel paint (one coat) complete all as specified and as directed
Dismantling and taking down old unserviceable LT panel board and Supply, installation, testing and commissioning of Panel board not less than 1.0m x 0.8 m x0.50 m , outdoor cubical type factory made (CPRI approved) ,double door , front & back both side openable type fixed with Butt Hinges and locking arrangement with Aldrop latches , fabricated of CRCA sheet , inner sheet 2.0 mm thick hinged type door for individual MCCBs and outer door 3.15 mm thick,rubberised gasket, supported on 50x 50 x 6 mm angle iron and Tee section frame dust and vermin proof complete with aluminium bus bar 4 Nos, 400 Amps rated capacity mounted on porcelain insulators totally enclosed chamber for protection 3 phase 415 volt with suitable capacity aluminium bus bar / PVC insulated copper cable control wiring duly mounted on PCC foundation with suitable size of bolts, nuts & wahsers and connecting all I/C & O/G existing cables. Panel board shall be powder coated and angle iron frame painted with black synthetic enamel paint over a coat of red oxide primer complete, connecting existing cables with suitable size glands and lugs to accommodate and including the following :-
(a) Aluminium busbar 400 Amps rated capacity-04 Nos. (b) MCCB 250 Amps, 4 pole, 415 volt, 25 KA thermal &magnetic release adjestable type - 01 No (for Incoming) (c) Spreader Link for MCCB - 02 Sets (d) Indication lamp Neon/ LED type (set of three) - 01 Set (e) Danger Notice plate - 01 No. (f) Panel control wiring with 10 sqmm s/c copper wire complete - 01 Job.
Dismantling and taking down old unserviceable LT panel board and Supply, installation, testing and commissioning of Panel board not less than 1.5m x 1.2 m x0.60 m , outdoor cubical type factory made (CPRI approved) ,double door , front & back both side openable type fixed with Butt Hinges and locking arrangement with Aldrop latches , fabricated of CRCA sheet , inner sheet 2.0 mm thick hinged type door for individual MCCBs and outer door 3.15 mm thick,rubberised gasket, supported on 50x 50 x 6 mm angle iron and Tee section frame dust and vermin proof complete with aluminium bus bar 4 Nos, 600 Amps rated capacity mounted on porcelain insulators totally enclosed chamber for protection 3 phase 415 volt with suitable capacity aluminium bus bar / PVC insulated copper cable control wiring duly mounted on PCC foundation with suitable size of bolts, nuts & wahsers and connecting all I/C & O/G existing cables. Panel board shall be powder coated and angle iron frame painted with black synthetic enamel paint over a coat of red oxide primer complete, connecting existing cables with suitable size glands and lugs to accommodate and including the following :-
INCOMING :- (a) Aluminium busbar 600 Amps rated capacity-04 Nos. (b) MCCB 400 Amps, 4 pole, 415 volt, 36 KA thermal &magnetic release adjestable type - 01 No (c) Spreader Link -02 Sets OUTGOING :- (a) MCCB 250 Amps,4 pole, 415 volt 25 kA thermal &magnetic release adjestable type - 02 Nos (b) MCCB 200 Amps, 4 pole, 415 volt 25 kA thermal &magnetic release adjestable type - 01 No (b) MCCB 160 Amps, 4 pole, 415 volt 16 kA thermal &magnetic release adjestable type - 01 No (c) Spreader Link -06 Sets (d) MCB TPN 63 Amps,415 Volt 'B' curve -02 Nos (e) MCB 6 Amps, 415 Volt, 'B' curve -03 Nos (f) Indication lamp Neon/ LED type (set of three) - 01 Set (g) Danger Notice plate - 01 No. (h) Panel control wiring with 16 sqmm s/c copper wire complete - 01 Job.
Dismantling and taking down old unserviceable LT panel board and Supply, installation, testing and commissioning of Panel board not less than 1.15m x 1.35 m x0.50 m , outdoor cubical type factory made (CPRI approved) ,double door , front & back both side openable type fixed with Butt Hinges and locking arrangement with Aldrop latches , fabricated of CRCA sheet , inner sheet 2.0 mm thick hinged type door for individual MCCBs and outer door 3.15 mm thick,rubberised gasket, supported on 50x 50 x 6 mm angle iron and Tee section frame dust and vermin proof complete with aluminium bus bar 4 Nos, 600 Amps rated capacity mounted on porcelain insulators totally enclosed chamber for protection 3 phase 415 volt with suitable capacity aluminium bus bar / PVC insulated copper cable control wiring duly mounted on PCC foundation with suitable size of bolts, nuts & wahsers. Panel board shall be powder coated and angle iron frame painted with black synthetic enamel paint over a coat of red oxide primer complete, connecting existing cables with suitable size glands and lugs to accommodate and including the following :-
Supply fabricate, fixing structural mild steel RS joist , channel angle iron, flat iron and brackets etc for fabrication of cross arms, bracing supports clamps including D clamps, eye hook and back plate etc fabricated from structural steel section including nuts , bolts, washers, welding (cold and hot ) drilling holes for bolts, bend to any shape or size as indicated and directed , inclusive of one primer coat and two coats of aluminium paint after preparation of surfaces complete all as specified and directed .
M/S. KARMAKAR ENGINEERING COMPANY (BID ID -3456191)
Jagatbandhu Enterprises (BID ID -3455612)
KARMIBRINDA (BID ID -3455898)
PAUL CONSTRUCTION (BID ID -3455383)
M/S DAWN ELECTRICAL INDUSTRIES (BID ID -3455524)
D K SARKAR (BID ID -3455303)
M/S GLORIOUS CONSTRUCTION (BID ID -3455993)
MS ORIENT ENGINEERING WORKS (BID ID -3454747)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
Tenderdoc8911.pdf
Tender Documents • 1.05 MB
BOQ_819608.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid