Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 LAccepted-Finance BAWAR POKAR BAKARGANJ PATNA BIHAR 800004 | PATNA | BIHAR | 800004 | ₹1.3 L | L1 | Accepted-Finance As per evaluation sheet |
| Sl No | Description | Qty | Unit | UNITED CONSTRUCTION COMPANY L1 |
|---|---|---|---|---|
| 1.01 | Wiring for circuit/ submain wiring alongwith earth wire with the 4 X 10 sq. mm + 2 X 6 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. | 15 | Mtr. | 650 ₹9,750 |
| 1.02 | Wiring for circuit/ submain wiring alongwith earth wire with the 4 X 6 sq. mm + 2 X 6 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required ( VTPN to Four Pole Enclosure) | 30 | Mtr. | 450 ₹13,500 |
| 1.03 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 16 sq. mm + 1 X 6 sq. mm earth wire . | 25 | Mtr. | 550 ₹13,750 |
| 1.04 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 4 sq. mm + 1 X 4 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required . | 90 | Mtr. | 250 ₹22,500 |
| 1.05 | Supplying and fixing 32 Amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of Four poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | 2 | Each | 1,450 ₹2,900 |
| 1.06 | Supplying and fixing 32 Amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of Triple poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | 1 | Each | 1,200 ₹1,200 |
| 1.07 | Supplying and fixing 40 amps amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of double poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | 2 | Each | 1,500 ₹3,000 |
| 1.08 | Supplying and fixing 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of double poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | 5 | Each | 1,200 ₹6,000 |
| 1.09 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of single poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | 24 | Each | 350 ₹8,400 |
| 1.10 | SPNDB :- Supplying and fixing 12 way , Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) | 2 | Each | 3,000 ₹6,000 |
Tender Value
₹1.4 L
EMD Value
₹2,745
Closing Date
4 Aug 2025, 5:00 pmClosed
Registrar
Registrar office, IIT Patna
Electrical work to provide power to several machine in CSE Dept block2, Math Dept Block 1 and Mechanical Dept Block 3 in IIT Patna.
2025_IITP_870618_1
IITP/ELECTMAINT/NIT01/25-26
Open Tender
Electrical Works
30 days
IIT Patna
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹2,745
5 Jan 2026
26 Jul 2025
5 Aug 2025
26 Jul 2025
4 Aug 2025
26 Jul 2025
Amount
Wiring for circuit/ submain wiring alongwith earth wire with the 4 X 10 sq. mm + 2 X 6 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Wiring for circuit/ submain wiring alongwith earth wire with the 4 X 6 sq. mm + 2 X 6 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required ( VTPN to Four Pole Enclosure)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 16 sq. mm + 1 X 6 sq. mm earth wire .
Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 4 sq. mm + 1 X 4 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required .
Supplying and fixing 32 Amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of Four poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 32 Amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of Triple poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40 amps amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of double poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of double poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of single poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
SPNDB :- Supplying and fixing 12 way , Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
SPNDB :- Supplying and fixing 8 way , Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
Four Pole MCB Metal Enclosure:- Supply fixing of 4P sheet steel enclosure on recess/ surface.
Double Pole MCB Metal Enclosure:-: Supply fixing of P sheet steel enclosure on recess/ surface.
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A modular socket-1 nos & 15/16 Amodular socke - 1 nos modular socket outlet and 5/6A Switch - 1 Nos 15/16 A Switch- 1 Nos modular switch, connections etc. as required.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid