| 3 | L3₹37.6 L+₹4.0 L (12.0%)Rejected-Finance PLOT NO 10 9 OM VIHAR PHASE 1 A UTTAM NAGAR NEW DELHI 110059 | WEST DELHI | DELHI | 110059 | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹44.6 L+₹11.1 L (32.9%)Rejected-Finance BARIYAWAN BARIYAWAN BARIYAWAN BARIYAWAN AMBEDKAR NAGAR UTTAR PRADESH 224210 | AMBEDKAR NAGAR | UTTAR PRADESH | 224210 | L4 | Rejected-Finance Not Being Lowest |
Tender Value
₹50 L
EMD Value
₹10,000
Closing Date
27 Jun 2022, 6:00 pmClosed
GE (Central) Delhi Cantt-10
GE (Central) Delhi Cantt-10
REPAIR/ REPLACEMENT OF UNSV PARTS OF LT PANEL INCLUDING EARTHING SUB MAIN WIRING DB AT CHURCH RD KANDHAR LINE RR COLONY AND UNSERVICEABLE ELECTRICAL FITTING WITH LED LIGHT FITTING INCLUDING MCBs MCCB AND OTHER MISC WORKS AT 61 CAV 48 MVH 105 TA 202 C
2022_MES_527856_1
GE/C-23/2022-23
Open Tender
Civil Works
Item Rate
270 days
GE (Central) Delhi Cantt-10
REPAIR/ REPLACEMENT OF UNSV PARTS OF LT PANEL INCLUDING EARTHING SUB MAIN WIRING DB AT CHURCH RD KANDHAR LINE RR COLONY AND UNSERVICEABLE ELECTRICAL FITTING WITH LED LIGHT FITTING INCLUDING MCBs MCCB AND OTHER MISC WORKS AT 61 CAV 48 MVH 105 TA 202 C
9 documents required · 9 mandatory
₹500
Yes
GE (Central) Delhi Cantt-10
₹10,000
Yes
1 Jul 2022
1 Jun 2022
29 Jun 2022
1 Jun 2022
27 Jun 2022
15 Jun 2022
1 Jun 2022 - 15 Jun 2022
Amount
Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc and making good disturbed surfaces of walls, floors etc.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid new PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall/ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded new metal flush box duly make embossed, concealed in walls with for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:-
(a) One light/Exh fan point controlled by one No one way switch
(c) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
(d) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
All as per item No 2 but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board.
M&L point wiring with PVC unsheathed multi stranded copper conductor cable 1.5 sqmm (nominal dia) FRLS 1100 Volts in existing PVC concealed conduit in new M S steel terminal boxes of wall thickness not less than 1.6mm including 3 mm thick laminated top sheet cover including using 1.5 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth all as specified and directed by Engr-in-Charge. PVC Cable
(a) One light/Exh fan point controlled by one No one way switch
(b) One bell / buzzer point controlled by one bell push
(c) One light point controlled by two Nos two way switches
(d) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
(e) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
M&L point wiring with PVC unsheathed multi stranded copper conductor cable 2.5 sqmm (nominal dia) FRLS 1100 Volts in existing PVC concealed conduit in new M S steel terminal boxes of wall thickness not less than 1.6 mm including 3 mm thick laminated top sheet cover including using 2.5 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth for one power point, all as specified and directed by Engr-in-Charge. PVC Cable
M&L in replacement switch piano flush button type single pole one way 6 Amps all as specified.
M&L in replacement switch piano 6 amp SP two way, ISI marked
M&L in replacement socket outlet 6 Amp flush button type all as specified
M&L in replacement bell push single pole 6 Amps all as specified
M&L in replacement switch piano flush button type single pole 16 Amps.
M&L in replacement socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole .
M&L in replacement regulator electronic switch type 5 steps suitable for 1200/1400 mm sweep 230 volts all as specified and directed.
M&L in replacement bell electric (dingdong) 230 volt, SP all as specified and directed.
M/L in replacement insulated body, angle holder (metal ring) with back plate ISI marked complete all as directed.
S&F ceiling rose surface PVC 65x50 mm type with three terminals. (For Exhaust Fans)
M&L in replacement sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket 240 Volts grade 10Amps complete with one single pole MCB 'C' series 10 A capacity all as specified and directed.
M&L in replacement Modular socket outlet 5 pin 6 Amp socket 2 module complete all as specified.
M&L in replacement switch Modular type 16 Amps one way, 1 module, 230V AC complete all as specified.
M&L in replacement Modular socket outlet 5 pin 6/16 Amp universal socket 2 module complete all as specified.
M&L in replacement Modular five stepped type electronic fan regulator 120W, 2 module 230V AC complete all as specified and directed by Engineer-in-Charge
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. (Mirror light)
Supply and fix LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
supply and fix recessed mounting LED FLAT panel 2"x2" made of crca sheet steel duly power coated with high efficient LED and glaire free full opal diffuser , IP 20 Suitable for 36 watt,230 volts ,50 Hz AC Supply, Neutral White,with electronic driver and incluiding all fixing accessories complete all as specified and directed.
S&F in replacement of decorative type (Comet) wall mounted luminaire with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base.
Supply and Fixing LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base
Supply and Fixing LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base.
Supply & fix in repair factory made epoxy powder coated Distribution Board TPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 40 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623.
Supply and fix MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix in repair MCCB 125 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting .
Supply and fix in repair MCB SPN 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply and fix in repair MCB DP 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply and fix in repair MCB SP 6 to 32 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply and fix in repair MCB SPN 40 to 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
S &F exhaust fan 300 mm in replacement sweep metal type including provision of 3 core PVC insulated sheathed 1100 volts grade flexible cable with stranded copper conductor from ceiling rose to fan, length as per requirement at site.
Supply and fixing Ventilating Fan 250 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmmincluding writing MES NO. 2 CM height with synthetic enamelled black paint complete all as specified and as directed.
Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed. Note: Three run of 6 Sqmm shall be measured as one lenght.
Supply and fix in repair Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories(Surface) in walls all as specified and as directed. Note: Three runs of 10 sqmm shall be measured as one length
M&L for earthing complete with galvanized steel earth plate 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel besides welding at all joints including excavation and earth work, GI pipe light grade 15mm bore for protection of G.I. wire from earth electrode to the Main switch/Distr Board, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B-1 using 20mm graded stone aggregate chamber and MS angle iron frame 40 x 40 x 3 mm and RCC cover 40 mm thick RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, round, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified & directed.
Cutting the existing wall/removing existing steel bar to make a hole for fixing of exhaust fan through packing of wooden ply to support the ventilating/ air circulating fan including necessary nut and bolts of suitable size incl make good of disturbed surface complete all as directed by Engr-in charge.
Supply and Fix in repair 45 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete as specified and directed. (Make Wipro/Bajaj/Havells.
Supply & Fix only swich & socket combined 5 pin 6 Amp, all as specified and directed by Engr-in-Charge.
Supply & Fix only swich & socket combined 5 pin 16 Amp, , all as specified and directed by Engr-in-Charge.
Supply only hylum sheets 3 mm thick (ISI marked) of the following sizes :-
(a) Sheet 4" x 4" single cutting suitable for one piano switch
(b) Sheet 4" x 4" two cuttings suitable for two piano switches
(c) Sheet 4" x 7" three cuttings suitable for three piano switches
(d) Sheet 4" x 7" one cutting for 6 Amp socket and two cuttings for piano switches
(e) Sheet 8" x 10" incl cuttings for switches and sockets 6/16Amps as directed.
(f) Sheet 10" x 12" incl cuttings for switches and sockets 6/16Amps as directed.
M & L for in replacement only single core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 2.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
M&L in replacement copper cable flexible 3 core PVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge.
M&L in replacement copper cable flexible 3 core PVC insulated of size 40/.0076 ll as specified and directed by Engr-in-Charge.
S & F hole fastner madeup of MS 6" long with complete nut bolt all as specified.Make:as per sample
S & F hole fastner madeup of MS 4" long with complete nut bolt all as specified.Make:as per sample
S&F GI Pipe bracket bent to shape drilled welded made out of light grade GI pipe 32mm dia 1.5 mtr long and fixing on the wall where as directed by the Engr-in-Charge for fixing of building security light fitting including clamps, nuts, bolts and washers complete all as specified by the Engr-in-Charge .
S&F in replacement capacitor of 2.5 MFD,
S&F in replacement capacitor of 3.5 MFD,
S&F in replacement capacitor of 6 MFD,
Supply & Fix only exhaust fan motor capacity 1/4 HP 230 volts suitable for 250 mm size exhaust fan complete all as directed.
M&L in replacement sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket 240 Volts grade 20Amps complete with one single pole MCB 'C' series 20 A capacity all as specified and directed.
S &F Wall fan 400 mm 3 blade in replacement sweep metal type including provision of 3 core PVC insulated sheathed 1100 volts grade flexible cable with stranded copper conductor, length as per requirement at site.
Supply and fix surface ceiling mounted, LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed by Engr-in-charge.
M&L earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc of size 25x4 mm thick galvanised strip duly fixed on suitable size of porcelain/ PVC insulator complete all as specified and directed.
Taking down carefully unserviceable distribution boards including disconnecting of incoming and outgoing connections complete all as specified and directed.
Supply and fix Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through metallic/ non metallic conduit in walls all as specified and as directed.
Schedule of Credit
M/s Adhikari construction co.
LAMBA ENTERPRISES
m/s VK construction company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .