Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹34.8 LAccepted-AOC 2 2 BLOCK B MAYUR RESIDENCY MISRAPUR KURSI ROAD LUCKNOW 226026 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226026 | 1 | Accepted-AOC L1 | |
| 2 | 2₹36.9 L+₹59,033 (1.62%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | 2 | Rejected-Finance Not L1 | |
| 3 | 3₹39.0 L+₹2.6 L (7.21%)Rejected-Finance | 3 | Rejected-Finance Not L1 | |
| 4 | 4₹43.8 L+₹7.5 L (20.5%)Rejected-Finance 210 C RAM DASS KA HATA SADAR CANTT LUCKNOW UP PIN 226002 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226002 | 4 | Rejected-Finance Not L1 | |
| 5 | Rejected-Technical 179 143 1 INDA NEAR SHAKTI BHAVAN KHARAGPUR 721305 | MEDINIPUR WEST | WEST BENGAL | 721305 | - | Rejected-Technical INELIGIBLE DUE TO NOT ENLISTED IN REQUISITE CATEGORY OF b (ii) |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
19 Feb 2022, 6:00 pmClosed
CWE Lucknow
229 MG Road Lucknow
MAINTENANCE/SERVICES TO APFC PANELS RING MAIN UNITS HT CABLE TERMINATION JOINTS AIR BREAK SWITCH AIR CIRCUIT BREAKERS CT AND PT OF RMU AND PERIODICAL CALIBRATION OF RELAYS OF RMU UNDER GE E/M
2021_MES_489057_3
CWE/LKO/EM/T-53 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE E/M LUCKNOW
₹76,000
Yes
28 Mar 2022
31 Jan 2022
21 Feb 2022
31 Jan 2022
19 Feb 2022
7 Feb 2022
Amount
Diconnecting the all elecrical connection and taking out the unserviceable components from APFC panel 125 KVAR and supply,fixing and testing (as per the existing cat part of the Schneider make mentioned against the respective items of APFC panel) the following new components of the APFC panel incl testing complete as directed.
Note for item no. 1.00 to 1.22: - (i) If any part missing in the description, the tendeerer has deemed visited the site before quoting the tender and include the items in the quoted rate. (ii) any civil work required at site to be included in quoted rate for the said item. (iii) Retro fitment job at site to be carried out by only Panel make company engineer. (iv) Power factor correction system shall be got tested by the contractor from Govt approved agency/manucfactuer premises, test roport /inspection report will be submitted to GE. (v) The quoted rate for the item no. 1.00 is deemed incluisve of disconnecting and taking out of any unserviceable component required to be repaired/replaced. (vi) All new components of APFC panel to be installed shall be measured and paid separately under respective item.
Supply and Fix in repair/ replacement as per the existing make and cat part for 250 Amp 3 pole MCCB 36 KA, built in μP based trip unit having protection functions LSIG. Variable current setting for L,S,I and G and variable time delay setting for L,S and G. Last fault trip history on LCD screen of MCCB i.e fallty phase, type of fault and interrupted current with ROH + spraders etc. Cat part No (LV525620+LV431563+LV429338)
Supply and Fix in repair/ replacement as per the existing make and cat part for 6 stage APFC relay-varlogic APFC relay- classic range (cat part 51207)
Supply and Fix in repair/ replacement as per the existing make and cat part for VAF , PF meter (cat part No 30002567)
Supply and Fix in repair/ replacement as per the existing make and cat part for LED lamp red direct integral LED 230 volts (cat part No XB7EVO04MPN)
Supply and Fix in repair/ replacement as per the existing make and cat part for LED lamp green direct integral LED 230 volts (cat part No XB7EVO03MPN)
Supply and Fix in repair/ replacement as per the existing make and cat part for LED lamp yellow direct integral LED 230 volts (cat part No XB7EVO05MPN)
Supply and Fix in repair/ replacement as per the existing make and cat part for Single pole MCB SP 2 Amp 10 KA (Cat part No A9N1PO2C)
Supply and Fix in repair/ replacement as per the existing make and cat part for Current Trnasformer 250/5A, Class-1.0, 10 VA
Supply and Fix in repair/ replacement as per the existing make and cat part for 63 Amp MCCB 3 pole 36 KA, CVS TMD type (cat part NO LV510335) for 25 KVAr
Supply and Fix in repair/ replacement as per the existing make and cat part for TVS E type, TP, power contractor 50 Amps (cat part N0-LC1E50M7) for 25 KVAr
Supply and Fix in repair/ replacement as per the existing make and cat part for Var Plus Max Al detuned reactor 25 KVAr 440 &% 50 HZ (cat part No LVRO7250A44L0) for 25 KVAr
Supply and Fix in repair/ replacement as per the existing make and cat part for Capacitor VarPlus box energy (MD-XL) 440V range 25 KVAr (cat part No MEHVBENY250A44) for 25 KVAr
Supply and Fix in repair/ replacement as per the existing make and cat part for 32 Amp MCCB, 3 pole 36 KA, CVS TMD type (cat part No -LV510332) for 10 KVAr
Supply and Fix in repair/ replacement as per the existing make and cat part for TVS E type, TP power contractor 32 Amp (cat part no LC1E3210M7) for 10 KVAr
Supply and Fix in repair/ replacement as per the existing make and cat part for VarPlus Max AL detuned reactor 10 KVAr 440 7% 50 HZ (cat part No LVRO7100A44LO) for 10 KVAr
Supply and Fix in repair/ replacement as per the existing make and cat part for Capicitors- VarPlus box Engergy (MD-XL) 440 range 10 KVAr (cat part No MEHVBENY100A44) for 10 KVAr
Supply and Fix in repair/ replacement as per the existing make and cat part for 16 Amp MCCB 3 pole 36 KA CVS TMD type (cat part No LV510330) for 5 KVAr
Supply and Fix in repair/ replacement as per the existing make and cat part for TVS E type TP power contractor 18 A (cat part No LC1E1810M7) for 5 KVAr
Supply and Fix in repair/ replacement as per the existing make and cat part for Var Plus Max AL dentuned reactor 5 KVAr 440V &% 50 HZ (cat part No LVRO7050A44LO) for 5 KVAr
Supply and Fix in repair/ replacement as per the existing make and cat part for Capacitor VarPlus box energy (MD-XL) 440 range 5 KVAr (cat part No MEHVENYO50A44)
Supply and Fix in repair/ replacement as per the existing make and cat part for Fresh air fan as per recommended manufacturer
Prediodical servicing of air circuit breaker and disconnecting the electrical connection from unserviceable parts and taking out the unserviceable material from the ACB and supply and fix the new material as per existing make/model/capacity incl cleansing and greasing fixed and movement parts etc. complete as specified and directed. Note :- (i) The rates quoted by the contactor shall include cost of any other spare parts not mentioned herein but essentially required for functioning of the system. (ii) Unit rates quoted by tenderers shall deem to include for, bolts, washers, lugs, thimble, wires and petty items required for efficient and smooth functioning of the equipment without any extra cost to the Govt.
Supply only Shunt release
Supply only Under voltage release
Supply only Earth fault release
Supply only Remote fault indicator
Supply only Microswitch for indication
Supply only lockable trip push botton
supply only locking ACB in isolating position
Supply only locking ACB in any position
Supply only racking interlock
Supply only door interlock
Supply only mechanical operation counter
Supply only Mounting kit for front mounted counter
Supply only sspring charge indication micorswitech
supply only racking pad lock assembly
Cable joint kit for 11 KV (earthed) grade cable for straight through heatshrink type joint complete with jointing material and accessories sutable for XLPE armoured aluminium conductor cable of size 50-95 sqmm etc complete as specified and directed Make-Mseal/Raychem RPG/3M
Cable joint kit for 11 KV (earthed) grade cable for straight through heatshrink type joint complete with jointing material and accessories sutable for XLPE armoured aluminium conductor cable of size 120-185 sqmm etc complete as specified and directed Make-Mseal/Raychem RPG/3M
Cable joint kit for 11 KV (earthed) grade cable for out door termination heatshrink type joint with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50-95 sqmm Make-Mseal/Raychem RPG/3M
Cable joint kit for 11 KV (earthed) grade cable for out door termination kit heatshrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 120-185 sqmm Make-Mseal/Raychem RPG /3M
Cable joint kit for 11 KV (earthed) grade cable for end termination indoor heatshrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50-95 sqmm Make-Mseal/Raychem RPG /3M
Cable joint kit for 11 KV (earthed) grade cable for end termination indoor heatshrink type joint complete with jointing material and accessories suitable XLPE armoured aluminium conductor cable of size 120-185 sqmm Make-Mseal/Raychem RPG /3M
Hiring of cable fault detector machine to detect exact position of faulty XLPE /PVC HT cable, 11000 Volts grade heavy duty aluminium conductor of any size and any length including excavation , relaying of protection cable cover, & removing and earth filling etc complete as specified and directed. Note : If any defect occurred at any place of Lucknow cantt area, the contractor will provide machnic & fault locator with material with in one hours for rectification of defects. If the contractor not provide the machanie and material with schedule time, the amount will be deduct @Rs. 1000/- per hrs after receiving phone/massage/ whatsapp /email etc complete as specified and directed.
M&L for cutting the trees branches, cleaning the sub station/4/2 pols structure/RMU area and taking out out grass roots and spraying the chemical (Roundup) in sub station in the ration 1: 15 for buring the grass every three month as specified and directed by Engr-in-charge.
S&F in repair VCB (trolley) 630A/800A of as per existing model and make (Areva -model No VMX& PIX-MW) ,Schnieder (model No SE-2012-W33-1-0015-),(C&S model No 12YR18/800), /ABB model No Vlnd12.08.25 incl all accessories as per existing VCB and also suitable for housing in the existing VCB panel etc complete as specified and directed. (Note- Tenderer has deemed visited the site before quoting the rate)
Prediodical serving RMU of 11 KV rating eveery month fixed/ moving contact & blowing out dust and applying the proper lubrication/ greasing of all moving parts,gas charging, tighting of all joints nut,bolt,washer, removing the moisture by jel/heating system and replacement of defective components as per existing make/model/capacity of VCB incl connecting the all electrical connection and caliveration of relay,testing the high voltage,timing & CRM etc complete all as specified and directed. Make- ABB/simens/Schnieder/Crompton
Note - (i) The above job to be carried out by OEM (ii) Replacing new items shall be measured and paid separately as supply only. (iii) If any defect occurred at any place of Lucknow cantt area, the contractor will provide machnic with in one hours for rectification of defects. If the contractor not provide the machanie and material with schedule time, the amount will be deduct 1000/hrs after receiving phone/massage/ watsup /email etc complete as specified and directed. (iv) Other part which is not included but requierd for functioning of equipment is included in the quoated rate &The contractor shall arrange for the standby supply for testing of relays, (v) Contractor visit the site before quoting the tender (vi) If any accident occured during the working. The contractor full resposible for settelement of any dispute
Supply only 400 series bolted type as per existing make/model
Supply only O ring 72x6 bushing 400 series bolted as per existing make/model
Supply only SF6 Gass cylinder (9 Kg)
Supply only shaft for operating handle as per existing make/model
Supply only 2PA machanisum w/o hex rod as per existing make/model
Supply only linkage between K and A as per existing make/model
Supply only ashida nano relay with modbus as per existing make/model/capacity
Supply only push button as per existing make/model/capacity
Supply only bracket A mechanisum hldg 2 push butoons as per existing make/Model
Supply only opening /closing finger as per existing make/model/capacity
Supply only 3 PKE mechanisum w/o Hex rod as per existing make/model
Supply only bracket for K machanisum as per existing make/model
Supply only bracket for CT MTG RMU RHS as per existing make/model
Supply only 24 KV VPIS cord as per existing make/model
Supply only capacitor unit VPIS 9-15 KV without cord
Supply only leak detector : type LS790B leak seeker as per existing make/model
Supply only pressure refilling equipment (KAR-6) as per existing make/model
Supply only ronis lock & key for RMU with Key A as per existing make/model
Supply only ronis key with hardware as per existing make/model
Supply only ronis key interlock of LBS with Key B as per existing make/model
Supply only ronis key interlock of LBS with Key C as per existing make/model
Supply only fuse holder assy as per existing make/model
Supply only terminal protector silcab for 11 KV as per existing make/model
Supply only T rhroud (new) for 11 KV as per existing make/model
Supply only reducer stud for cable bushing A as per existing make/model/cap
Supply only trip coil only Y1 /Y2 control volts 24 VDC
Supply O Ring 65x5 for LBS mech bushing as per exising make/model/cap
Supply only spring charging motor with gear 24 V DC as per existing make/model/cap
Supply only monometer+gas desity switch as per existing make/model
Supply only electronic motor kit for C module-Mgvcl as per existing make/model
Supply only standard motorised kit for V model as per existing make/model
Supply only bracket for RMU (new indication) as per existing make/model
Supply only position inicator as per existing make/Model
Supply only indicator local as per existing make/model
Supply only monometer assy as per existing make /Model
Supply only motorised kit for C model
Supply only capacitor unit VPIS 15-24 KV without cord
Supply only s series bushing as per existing make/model/capacity
Supply only O ring for S series bushing as per existing make/model/cap
Supply only VPIS bracket B (for V module-EL mechanisum)
Supply only upper bracket for VPIS (for C model)
Supply only bracket VPIS bottom (for V modul GPV mech)
Supply only O ring for S series busing as per existing make/model/size
Supply only battery 12 VDC, 12 AH as per existing make/model
Supply only 11 KV boot as per existing make/model/size
Supply only lithim battery suitable for RMU 1/2 AA 3.6 Volts or as per existing make/ model/ capacity
Supply, install, testing and commissioning of Indoor type 100 kVAr Automatic power factor correction(APFC) Panel. APFC panel with metalised polypropylene capacitor Bank, MPP heavy Duty of capacity 100 KVAR (20x4+10x1+5x1+3x1+2x1) with over current with stand capacity of 3.0I and step banking as per load requirement with minimum 08 steps relay controller microprocessor based with minimum operating current 11 mA) 3-phase 3-CT operated having provision of multifunctional display, set optimizing control of capability with having facility of display system voltage, current, active power,apparent power, reactive power, cos phi, power factor (COS, P.F, V, I, KW, KVA, KVAR, THD I % and THD V%upto 33rd level) with alarm output including alarm system and front panel programming including connection with PVC copper cable of suitable size, housed in powder coated PBI sheet housing with hinged door, dust proof and connection with main etc all as directed with following components:-
(all components &capacitors bank shall be housed inenclouser factory made, made out of 16 SWG MS sheet, indoor in installation KIOSK type dust and vermin proof with suitable ventilating shutters (louvers), powder coated sheet metal feeder pillar box as per IS-5039 all as specified having locking arrangement with MCCB TP, 200 Amp (25 Ka with TM Release) 01 no. Set of CT,s, Contactor Capacitor duty TP 415 volt with AC Coil including MCBs indicating lamps and bypass system, alarm bell 240v, 50 Hz – 01 No etc complete to achieve point 0.99/1.00 near to unity. Contd....
Capacitors, switchgears and panel should be manufactured completely in- house and of the specified make including necessary foundation pillar type copper bus bars of suitable size, 3 phase system complete all as specified and directed.
Supply, install, testing and commissioning of Indoor type 125 kVAr Automatic power factor correction(APFC) Panel. APFC panel with metalised polypropylene capacitor Bank, MPP heavy Duty of capacity 125 KVAR (50x1+25x2+10x1+5x2+3x1+2x1) with over current with stand capacity of 3.0I and step banking as per load requirement with minimum 08 steps relay controller microprocessor based with minimum operating current 11 mA) 3-phase 3-CT operated having provision of multifunctional display, set optimizing control of capability with having facility of display system voltage, current, active power,apparent power, reactive power, cos phi, power factor (COS, P.F, V, I, KW, KVA, KVAR, THD I % and THD V%upto 33rd level) with alarm output including alarm system and front panel programming including connection with PVC copper cable of suitable size, housed in powder coated PBI sheet housing with hinged door, dust proof and connection with main etc all as directed with following components:-
(all components &capacitors bank shall be housed inenclouser factory made, made out of 16 SWG MS sheet, indoor in installation KIOSK type dust and vermin proof with suitable ventilating shutters (louvers), powder coated sheet metal feeder pillar box as per IS-5039 all as specified having locking arrangement with MCCB TP, 250 Amp (25 Ka with TM Release) 01 no. Set of CT,s, Contactor Capacitor duty TP 415 volt with AC Coil including MCBs indicating lamps and bypass system, alarm bell 240v, 50 Hz – 01 No etc complete to achieve point 0.99/1.00 near to unity. Contd......
Capacitors, switchgears and panel should be manufactured completely in- house and of the specified make including necessary foundation pillar type copper bus bars of suitable size, 3 phase system complete all as specified and directed.
Supply, install, testing and commissioning of Outdoor type 100 kVAr Automatic power factor correction(APFC) Panel. APFC panel with metalised polypropylene capacitor Bank, MPP heavy Duty of capacity 100 KVAR (20x4+10x1+5x1+3x1+2x1) with over current with stand capacity of 3.0I and step banking as per load requirement with minimum 08 steps relay controller microprocessor based with minimum operating current 11 mA) 3-phase 3-CT operated having provision of multifunctional display, set optimizing control of capability with having facility of display system voltage, current, active power,apparent power, reactive power, cos phi, power factor (COS, P.F, V, I, KW, KVA, KVAR, THD I % and THD V%upto 33rd level) with alarm output including alarm system and front panel programming including connection with PVC copper cable of suitable size, housed in powder coated PBI sheet housing with hinged door, dust proof and connection with main etc all as directed with following components:-
(all components &capacitors bank shall be housed inenclouser factory made, made out of 16 SWG MS sheet, indoor in installation KIOSK type dust and vermin proof with suitable ventilating shutters (louvers), powder coated sheet metal feeder pillar box as per IS-5039 all as specified having locking arrangement with MCCB TP, 200 Amp (25 Ka with TM Release) 01 no. Set of CT,s, Contactor Capacitor duty TP 415 volt with AC Coil including MCBs indicating lamps and bypass system, alarm bell 240v, 50 Hz – 01 No etc complete to achieve point 0.99/1.00 near to unity. Contd...
Capacitors, switchgears and panel should be manufactured completely in- house and of the specified make including necessary foundation pillar type copper bus bars of suitable size, 3 phase system complete all as specified and directed.
Prediodical serving VCB of 11 KV rating fixed/ moving contact & blowing out dust and applying the proper lubrication/ greasing of all moving parts,gas charging, tighting of all joints nut,bolt,washer, removing the moisture by jel/heating system and replacement of defective components as per existing make/model/capacity of VCB incl connecting the all electrical connection and caliveration of relay,testing the high voltage,timing & CRM etc complete all as specified and directed. Make- Areva/schnieder/abb/C&S/simens
Note: - (i) The above job to be carried out by engineer of authorised OEM only. (ii) Replacing new items shall be measured and paid separately as supply only. (iii) If any defect occurred at any place of Lucknow cantt area, the contractor will provide machnic with in one hours for rectification of defects. If the contractor not provide the machanie and material with schedule time, the amount will be deduct 1000/hrs after receiving phone/massage/ watsup /email etc complete as specified and directed. (iv) Other part which is not included but requierd for functioning of equipment is included in the quoated rate &The contractor shall arrange for the standby supply for testing of relays, (v) if any accident occured during the repair , the contractor full responsible for settelement of all issue.
Supply only closing coil as per existing make/model/capacity
Supply only triping coil as per existing make/model/capacity
Supply only earth fault relay as per existing make/moede/capcity
Supply only isolating contact flat type as per existing make/model/capacity
Supply only spring charging motor as per existing make/model/capacity
Supply only digital volt meter as per existing make/ model/capcity
Supply only digital ammeter as per existing make/model/capacity
Supply only digital indicator lamp as per existing make/model/capcity
Supply only cast regin wound CT as per existing ratio/make/model/capacity
Supply only annaunciators as per existing make/model/capcity and size
Supply only breaker housing
HBX-LR
HVX-HR
Insulating rod
Supply only operating machanisum without coil and motor as per existing make/model/capacity
Supply only breaker auxiliary switch as per existing make/model/capacity
Supply only motor cut off switch as per existing make/model/capacity
Supply only main drive shaft asssembly as per existing make/model/capacity
Supply only trip fork linkage assembly as per existing make/model/capacity
Supply only retchet wheel as per existing make/model/capacity
Supply only pin for retchet as per existing make/model/capacity
Supply only handle block assembly as per existing make/model/capacity
Supply only closing coil box assembly (without coil) as per existing make/model/capacity
Supply only trip coil box assembly (without coil) as per existing make/model /capacity
Supply only motor cut off lever assy as per existing make/model/capacity
Supply only trip prop support assembly as per existing make/model/ capacity
Supply only pin for release lever as per existing make/model/capacity
Supply only release lever as per existing make/model/ capacity
Supply onlhy auxilary switch drive assembly as per existing make/model/capacity
Supply only charging pawl as per existing make/model/capaacity
Supply only buffer for spring as per existing make/model/capaacity
Supply only over stop and stop pin
Supply only phase busbar spout as per existing make/model/capacity any phase
Supply only circuit spout as per existing make/model/capacity
Supply only limit switch assembly as per existing make/model/capacity
Supply only vaccum intrurrpter as per existing make/model/size/capacity
Supply only Tnc switch as per existing make/model/capacity
Supply only Power Pack units with maintenance free solid batteries in sheet metal enclosure as per existing make/model/capacity
Supply only high voltage fuse as per existing make/model/capacity
Supply only Elstein HFS panel heater 300 watt suitable for 11/33 kv VCB for removing the moisture
Supply only male/female /cluster contact as per existing make/model/capacity
Prediodical serving CSS of 11 KV rating, disconnecting the HT cables of any size and servicing the fixed/ moving contact & blowing out dust and applying the proper lubrication/ greasing of all moving parts,gas charging, tighting of all joints nut,bolt,washer, removing the moisture by jel/heating system of HT & LT side, Dehydration ¢rifuging tranformer oil and repair and replacement of defective components as per existing make/model/capacity of CSS & unserviceable wiring and reassembling the CSS incl connecting the all electrical connection and testing complete all as specified and directed.
Note :- (i) The contractor shall arrange for the standby supply for testing of relays, (ii) The rates quoted by the contactor shall include cost of any other spare parts not mentioned herein but essentially required for functioning of the system. (iii) Testing of above job to be carried out by engineers of authorised dealer/services centre of concerned OBC (iv) No extra payments will be made to the contractor for the same. (v) Unit rates quoted by tenderers shall deem to include for, bolts, washers, lugs, thimble, wires and petty items required for efficient and smooth functioning of the equipment without any extra cost to the Govt.
Supply only MCCB 3 pole 315 Amp 50 KA
Supply only MCCB 3 pole 100 Amp 35 KA
Supply only Digital Voltmeter
Supply only Digital Ammeter
Supply only Winding temp gause
Supply only Oil temp gause
Supply only Battery as existing capacity
Supply only Power pack as per existing capacity
Supply only LED Indicator
Supply only Shunt release
Supply only Under voltage release
Supply only Earth fault release
Supply only Remote fault indicator
Supply only Microswitch for indication
Supply only UN-CO module for breaker control
Supply only Heavy duty capacitors
Supply only Capacitor dutry contractor
Supply only APFC controller
APFC relay as per exising stage, make and model
Supply only heater as per existing make/model/cpacity
Unnati Engineers
M/s Naresh Chand
M/S PRATAP BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .