| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.8 LAccepted-AOC 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹43.9 L+₹1.8 L (4.32%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L2 | Rejected-AOC High | |
| 3 | L3₹44.2 L+₹2.1 L (4.96%)Rejected-AOC | L3 | Rejected-AOC High | |
| 4 | L4₹45 L+₹2.9 L (6.92%)Rejected-AOC ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L4 | Rejected-AOC High | |
| 5 | L5₹48.3 L+₹6.2 L (14.7%)Rejected-AOC | L5 | Rejected-AOC High |
Tender Value
₹51 L
EMD Value
₹1.0 L
Closing Date
27 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh A P Singh, IDSE CWE Chandimandir
HQ CWE Chandimandir
CA NO. CWE/CHM(U)-24/2022-23 REPAIR AND MAINT OF HT 11 KV DISTRIBUTION NETWORK AND CONNECTED ITEMS OF WORKS AT OTM ACCN AREA AT CHANDIMANDIR
2022_MES_530906_1
CWE/CHM(U)-24/2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
HQ CWE Chandimandir
Class C and Cat b(ii)
8 documents required · 8 mandatory
₹1,000
Yes
GE (U) Chandimandir
₹1.0 L
Yes
20 Sept 2022
14 Jun 2022
1 Aug 2022
14 Jun 2022
27 Jul 2022
6 Jul 2022
15 Jun 2022 - 24 Jun 2022
Amount
Disconnecting and taking out existing defective HT cable of any size complete including joints/protection pipes etc from trenches/ducts/poles etc complete all as specified and directed.
Taking out old damaged PCC pole of any size incl demolition of PCC work and clearing the site complete all as specified and directed.
Taking down old rusted cross arms/anti climbing devices incl clamps, nuts/bolts etc complete all as specified and directed.
Taking down old unserviceable HT insulators of any size and type complete all as specified and directed.
Disconnecting and taking out feeder pillar box of any type and size complete all as specified and directed.
Taking down old burnt HT jumpers of any size/type complete all as specified and directed.
Taking down old unserviceable HT GOD of any size/type complete all as specified and directed.
Taking out old unserviceable rubber mats of any size and type complete all as specified and directed.
Taking down old broken cable route indicator of any size/type complete all as specified and directed.
Taking down old unserviceable HT lightening arrestors of any size/type complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for laying of cable,poles etc. and getting out complete all as specified and directed.
All as per Item No. 11.00 here-in-before but depth exe 1.5 mtr and not exe 3.0 mtr complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
Un-reinforced precast concrete cable cover, class HV, type 1 flat , size 300mm x 180mm x 40mm complete all as specified and directed.
Old size bricks laid flat for protection to UG LT cables complete all as specified and directed.
Dry sand filling under and around UG cable to provide cushioning complete all as specified and directed. Note. Only punned thickness shall be measured.
Supply and fixing in trenches, ducts or fixing along the poles or passing through pipes or laid under floors etc and testing XLPE insulated , screened PVC bedded, galvanised steel strip armoured, heavy duty HT power cables ISI marked with aluminium conductor, 11000 volts grade cross sectional area 95 sqmm 3 core, 11 KV earthed, complete all as specified and directed.
All as per item No 18.00 here-in-before but 185 Sqmm 3 core
All as per item No 18.00 here-in-before but 240 Sqmm 3 core
S & F HT heat shrinkable type outdoor end termination cable jointing kit with jointing material and accessories suitable for 11000 volt (Earthed) grade XLPE cable of size 95 Sqmm, 3 core complete all as specified and directed.
All as per item No 21.00 here in before but of size 120 to 185 Sqmm, 3 core complete all as specified and directed.
All as per item No 21.00 here in before but of size 240 sqmm, 3 core complete all as specified and directed.
HT heat shrinkable type indoor end termination cable jointing kit with jointing material and accessories suitable for 11000 volt (Earthed) grade XLPE cable of size 95 Sqmm, 3 core complete all as specified and directed.
All as per item No 24.00 here in before but of size 120 to 185 Sqmm, 3 core complete all as specified and directed.
All as per item No 24.00 here in before but of size 240 sqmm, 3 core complete all as specified and directed.
HT straight through heat shrinkable type cable jointing kit for 11 KV grade, XLPE cable of size 95 sqmm 3 core complete all as specified and directed.
All as per item No 27.00 here in before but of size 120 to 185 Sqmm, 3 core complete all as specified and directed.
All as per item No 27.00 here in before but of size 240 sqmm, 3 core complete all as specified and directed.
Disconnecting HT cable of size 150/185/240 sq mm 3 core from line , taking down carefully from poles/ structure, extending the length and reconnecting by taking up and testing for working complete all as specified and directed
32 mm x 6 mm GI strip and connecting from earth test point to lightening arrestor installed on top of 11 mtr long poles four pole/ two pole structuresas in repairs complete all as specified and directed.
GI tubes 100 mm bore light grade for cable protection on poles/walls/under road/culvert etc complete all as specified and directed.
GI tubes 80 mm bore light grade for cable protection on poles/walls/under road/culvert etc complete all as specified and directed.
PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in pole foundations etc complete all as specified and directed.
PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts etc including provision of necessary form work complete all as specified and directed.
PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in pole / strut coping complete all as specified and directed.
Route indicator for HT cable disc type of size 150 mm dia CI, 8 mm thickness embossed with "MES HT CABLE" and fixed on angle iron 35 x 35 x 5 mm, 600 mm long as directed and painted in anti corrosive brown color paint incl PCC 1:2:4 type B-1 foundation block of size 300 x 300 x 300 mm, duly fixed in ground as in repairs complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 60x60cmx6 mm thick burried directly in ground ( earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised earth lead strip 32x6mm dia by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 5 of SSR Part-I 2009 connected to earthing test point panel all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber (1 : 3 : 6) type C1, CI pit cover and frame , charcol, salt including earth lead protected by 40 mm dia medium grade GI pipe and 20mm dia medium grade GI Pipe for watering complete. Note :- Earth lead strip 32 x 6 mm and GI 40 mm dia protecion pipe upto 7.5 mtr length will be deemed to include in the unit rate quoted.
Gang operated air break switches with vertical isolation complete with drop out fuse unit triple pole, 12 insulator type, manually operated, mounted on insulators and steel frame, with operating mechanism worked from ground level for rating 400 Amps, 11000 volts complete with GI operating pipe of heavy duty grade of suitable length complete all as directed.
All as per item no 39.00 here in before but of rating 200 Amps.
Servicing of the outdoor type HT 11000 volts 200 amps/400 amps capacity gang operated air break switch mounted on HT two pole/four pole structure by properly adjusting the mountings for ON/OFF operation by working from ground level, adjusting the length of operation rod ,lubricating the moving parts, tightening of all nuts/bolts, checking of all jumper connections for proper contact of male/female contacts, replacing worn out spares and testing for proper working complete all as specified and as directed. Note:- Spare parts will be measured and paid separately.
Supply only moving contact blade (male contact) suitable for 200 amps 11000 volts outdoor GOAB switch complete all as specified and directed.
Supply only spring loaded fixed contacts (female contact jaw) suitable for 200 amps 11000 volts outdoor GOAB switch complete all as specified and directed.
Supply only post insulators suitable for 200 amps 11000 volts outdoor GOAB switch complete all as specified and as directed.
Supply only tinned copper flexible wires woven connecting jumper suitable for 200 amps 11000 volts outdoor GOAB switch complete all as specified and as directed.
Supply only MS jumper carrier for 200 amps 11000 volts outdoor GOAB switch complete all as specified and as directed.
Lightening arrestors expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp complete all as directed.
Anti climbing devices, spikes type fabricated out of M.S. bars ( round,square and flat ) including nuts,bolts,Washers and clamps in two halves made to shape to suit the cross section of the pole complete all as specified and directed.
Cross arms,supports, clamps etc fabricated from structural steel section including nuts, bolts , washers, welding, bending ( cold or hot ) drilling holes for bolts bent to any shape or size as indicated or directed inclusive of one primer coat of red oxide zinc chromate one under coat and one finishing coat of aluminium paint complete all as specified and directed.
PCC 1:2:4 type B-2 using 40 mm graded crushed stone aggregate as in transformer foundation including form work as required at site complete all as specified and directed.
Pin type insulator porcelain, vitreous white/brown including one galvanised MS spindle nut and two GI washers of size 150 mm height, 150 mm dia for 11000 volts complete all as specified and directed.
Single disc porcelain, vitreous white/brown insulator 255 mm dia and 145 mm height assembly for tension with tension clamps for conductor working pressure 11000 volts complete all as specified and directed.
Steel tubular swaged poles complete with mild steel base plate, closed at top as specified, type 410 SP-55 (11 metre long) including painting with two coats of black bitumonous paint externally up to the planted depth and internally through out and remaining external portion with two coats of aluminium paint , over a coat of red oxide primer complete all as specified and directed. Note: Excavation & earthwork, foundation concrete will be meaured & paid for separately under respective item(s).
Supply and filling/spreading uniformly 40/50 mm dia stone aggregate at two pole/four pole structures or any other location at sub stations all as directed.
Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT,25x 20 cm size complete all as specified and directed.
Preparing the surfaces for repainting by removing dust/rust etc and painting of old steel tubular poles 11 Mtr long alonwith cross arms / clamps etc with two coat of aluminium paint over a coat of red oxide primer all as directed by Engineer-in-Charge , incl providing yellow & black paint with 30 cm alternate strip up to 1.2 mtr height from GL complete all as specified and directed.
Jumpers in red/yellow/blue colour for HT lines/connections made from aluminium conductor single core PVC insulated cable of suitable size complete including winding wires, aluminium tapes etc complete all as specified and directed.
Finding of fault to 11 KV UG cable with suitable fault locator equipment & pin point the fault in the faulty cable including necessary excavation and earth work for exposing the faulty portion of the UG cable complete all as specified and directed.
Cutting wild grass,bushes shrubs etc and cleaning of area/yard of sub station buildings complete all as specified and directed.
Supply and filling for topping up insulating oil with dielectric strength not less tha 50 KV complete all as specified and directed.
Chequred rubber mat for electrical purpose ISI marked of size 1 mtr X 2 mtr and 19 mm thickness complete all as specified and directed.
LT underground cable XLPE insulated, PVC sheathed, armoured heavy duty and 1100 volts grade with multistranded aluminium conductor of size 240 sqmm 3.5 core in trenches/ducts/through pipes/under culverts etc complete incl taking out the old burnt cable complete all as specified and directed.
All as per item No 62.00 here in before but size 400 sqmm 3.5 core.
All as per item No 62.00 here in before but size 10 sqmm 2 core.
Supply, installation,commissioning and testing outdoor type floor mounting double door feeder pillar box , fabricated from 3.15 mm thick CRCA sheet and MC 75 for base channel, 04 nos legs 750 mm long made from 50 x 50 x 6 mm angle iron , duly powder coated, dust/water and weather proof , grouted in PCC 1:2:4 type B-1 foundation, suitable for 415 volts, 3 phase, 4 wire , 50 Hz complete of suitable size with and including the following:- [a] Aluminium strip bus bar TPN sleeve insulated mounted on epoxy insulators of capacity 1000 amps - 01 set. [b] MCCB FP 630 amps , 415 volts, 50 Hz, 35 KA with adjustable thermal and magnetic release and Ics=100% of Icu - 01 No (Incoming) [c] MCCB TP 400 amps , 415 volts, 50 Hz, 35 KA with adjustable thermal and magnetic release and Ics=100% of Icu - 02 No (including 01 No. spare) and MCCB TP 250 amps , 415 volts, 50 Hz, 35 KA with adjustable thermal and magnetic release and Ics=100% of Icu - 01 No (Outgoing) [d] Earthing terminals - 02 Nos and danger notice plate - 01 No. [e] Pre-wired Digital meter with voltmeter, ammeter, slector switch, CTs, and Indicating Lights or approved makes - 01 Set
Supply, installation,commissioning and testing outdoor type floor mounting double door feeder pillar box , fabricated from 3.15 mm thick CRCA sheet and MC 75 for base channel, 04 nos legs 750 mm long made from 50 x 50 x 6 mm angle iron , duly powder coated, dust/water and weather proof , grouted in PCC 1:2:4 type B-1 foundation, suitable for 415 volts, 3 phase, 4 wire , 50 Hz complete of suitable size with and including the following:- [a] Aluminium strip bus bar TPN sleeve insulated mounted on epoxy insulators of capacity 400 amps - 01 set. [b] MCCB FP 250 amps , 415 volts, 50 Hz, 35 KA with adjustable thermal and magnetic release and Ics=100% of Icu - 01 No (Incoming) [c] MCCB TP 160 amps , 415 volts, 50 Hz, 35 KA with adjustable thermal and magnetic release and Ics=100% of Icu - 02 No and MCCB TP 100 amps , 415 volts, 50 Hz, 35 KA with adjustable thermal and magnetic release and Ics=100% of Icu - 01 No (Outgoing) [d] Earthing terminals - 02 Nos and danger notice plate - 01 No. [e] Pre-wired Digital meter with voltmeter, ammeter, slector switch, CTs, and Indicating Lights or approved makes - 01 Set
Disconnecting the electrical supply, disconnecting incoming/outgoing cable connections, taking down the existing transformer of capacity 200 KVA to 500 KVA from the foundation and keeping on the four pole structure or vice versa, safely using crane of suitable capacity , making all incoming/outgoing cable connections and testing for satisfactory working complete all as directed.
Disconnecting the electrical supply, disconnecting incoming/outgoing cable connections, taking down the existing transformer of capacity 200 KVA to 500 KVA from the foundation/ four pole structure and shifting to a location within 500 mtrs using crane of suitable capacity and keeping on the foundation / four pole structure safely, making all incoming/outgoing cable connectios and testing for satisfactory working complete all as directed.
R D Bansal
Shree Balaji Construction
NARINDER KUMAR SONS
M/S BALWINDER SINGH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .