| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.5 LAccepted-AOC NEAR JAMIA MASJID HOSPITAL ROAD UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC Due to being L1 | |
| 2 | L2₹31.8 L+₹51,780 (1.65%)Rejected-Finance 15A 9 CHOWBHAGA ROAD KOLKATA KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹33.0 L+₹1.7 L (5.32%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹38.3 L+₹7.0 L (22.5%)Rejected-Finance | L4 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹84,800
Closing Date
14 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITIES UDHAMPUR
GE UTILITIES UDHAMPUR PO GARHI PIN 182121
Repair/Maintenance of AC plants, cooling towers, refrigeration section and summer appliances under GE (Utilities) Udhampur.
2022_MES_507960_1
GE/U-67/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
GE UTILITIES UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹84,800
Yes
1 Apr 2022
14 Feb 2022
16 Mar 2022
14 Feb 2022
14 Mar 2022
28 Feb 2022
90 days
Amount
Repair/Servicing of cooling tower of AC plant FRP type by dismantling and taking out the honey comb PVC fills complete and PVC nozzles, descaling the PVC fills by suitable descaling solution including brushing and cleaning complete with cleaning solution and water, replacing the defective PVC filling, cleaning the nozzles and replacing the defective PVC flange alongwith rubber gasket, rusted bolts, nuts and washers etc, cleaning the water sump and XPM wire mesh with suitable cleaning solution re-assembling the same including replacing the defective water filter flanges of pipe joints etc and testing complete all as specified and directed by Engr-in-Charge. Note: PVC Fills will be measured and paid separately
Servicing of 3 Nos compressor capacity upto 7.5 TR unit by draining out the used compressor oil, opening both side covers, head covers and taking out the defective oil filter, cleanings the sump by using suitable cleaning solution, replacing the defective oil filter element, checking of suction and discharge valves, adjust them and refixing the side covers, head covers including replacing the suitable gaskets complete and re-filling of new compressor oil to the required level, removing the pully, checking the serviceability of shaft seal assy, replacement of shaft seal assly and refixing the pully including replacing the defective gas filter and testing complete all as specified and directed by Engr -in-Charge. Note: Oil filter element, gas filter and shaft seal will be measured and paid for separately.
Cleaning the external surfaces of equipment/accessories of central AC plant 5/7.5 TR capacity and painting with two coats of synthetic enamel paint of existing colour including writing SM/MES No, marking flow direction, set Nos etc complete all as specified and directed by Engr-in-Charge. Plant comprising of following :-- (a) Induction motor - 11 KW - 3 Nos. (b) Condenser - 3 Nos. (c) Compressor Unit 5 TR - 3 Nos. (e) Condenser pump set - 2 Nos. (f) LT control panel board cubical type - 1 No. (g) Cooling tower for 5 TR - 1 No. (j) Condenser line pipeing. (k) AHU units and complete piping etc.
Supply only compressor oil in sealed container manufactured by Hindustan Petrolium Limited as per site requirement or equivalent complete all as specified and directed by Engr-in-Charge.
Repair/Replacement of 5 TR compressor for air - Cooled ductable package units Hermetic Scroll Compressors and Microprocessors control panel,high pressure low pressure cut out, temperature control device of the following Nominal complete all as specified and directed by Engr-in-Charge.
Unloading, Lifting, Shifting,and placing at foundation including valve Installation, Testing and Commissioning of Air Cooled, Ductable units of 5TR capacity complete all as specified and directed by Engr-in-Charge.
Repair/Replacement of ducting made out of GI Sheet of 22 gauge in replacment of the burnt out parts of ducting complete all as specified and directed by Engr-in-Charge.
Repair/Replacement of Acoustic Lining with 25mm thick fiber glass wool with tissue paper and 28g perforated aluminium sheet in supply air ducts complete all as directed by Engr-in-Charge.
Repair/Replacement of 32mm PVC drain pipe line including clamps with accessories complete all as specified and directed by Engr-in-Charge.
Repair/Replacement of flexible double canvas connection complete all as specified and directed by Engr-in-Charge.
Copper Refrigerant Piping of size 1/8 complete all as specified and directed by Engr-in-Charge.
Copper Refrigerant Piping of size 7/8 complete all as specified and directed by Engr-in-Charge.
Four single core PVC insulated FRLS unsheathed copper conductor cable 1100 volts grade 2.5sqmm size in ISI marked with 2.5 sqmm PVC insulated FRLS copper conductor cable as earth lead to connecting to earth dolly complete all as specified and directed by Engr-in-Charge.
Four single core PVC insulated FRLS unsheathed copper conductor cable 1100 volts grade 4sqmm size in ISI marked with 4sqmm PVC insulated FRLS copper conductor cable as earth lead to connecting to earth dolly complete all as specified and directed by Engr-in-Charge.
Four single core PVC insulated FRLS unsheathed copper conductor cable 1100 volts grade 4sqmm size in ISI marked with 6 sqmm PVC insulated FRLS copper conductor cable as earth lead to connecting to earth dolly complete all as specified and directed by Engr-in-Charge.
Repair /Replacement of burnt Heating strip heater capacity 3kw with pan type humidifer all controls. Heating thermostat, humidity stat etc., complete all as specified and directed by Engr-in-Charge.
Dismantling and taking out of old unserviceable LT Panel for 5/7.5 TR at 1FOD and CHNC and supply, installing and testing LT indoor type weather proof panel floor mounted on equal angle CRCA steel sheet dust and vermin proof duly powder coated and wired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI similar design and technology shall be adopted for fabrication of panel, size of panel length 1875mm,Height 3000mm,Depth 400mm,sheet will be 1.6mm. Copy of CPRI test report shall be produced to GE along with the certificate from manufacturer of the panel that the similar design and standard have followed in these panels.The panel shall be comprising of following accessories complete all as specified and directed by Engr-in-Charge.
Earthing complete with galvanized steel earth plate electrode 600 mm x 600mm x6mm thick buried directly in ground ( earth pit not less than 2.25 metre of below normal ground level ) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 32x6mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron, including PCC pit in PCC, M-15, type B-1 RCC cover made out of cement concrete, M-15, type B-1, (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40x40x5mm frame, GI medium grade watering pipe 20mm bore and funnel with wire mesh, light grade protection pipe 40mm bore up to main board complete all as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by Engr-in-Charge.
Repair /Replacement of magnetic contactor 40amp, over load relay, single phase perventor panel for 7.5 and 5.5 TR AC plant complete all as specified and directed by Engr-in-Charge.
Repair /Replacement of compressor for air cooled ductable package units with gas 407c Hermetic Scroll Compressors and Microprocessors control panel,high pressure low pressure cut out, temperature control device of the 7.5 TR nominal capacity complete all as specified and directed by Engr-in-Charge.
Unloading, Lifting, Shifting,and placing at foundation including valve Installation, Testing and Commissioning of Air Cooled, Ductable units of 7.5 TR complete all as specified and directed by Engr-in-Charge.
Supply and charging refrigerant gas R-22 complete all as specified and directed by Engr-in-Charge.
Supply and charging refrigerant gas R-410 complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable metal plug socket and supply and fix new metal plug and socket board complete enclosure with single pole and neutral and earth plug with MCB SP 32/40 Apms, 220 Volts complete suitable for window/Split type complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable front show grill and supply and fix new front show grill for LG/Voltas /Sidwal/Godrej window type AC 1.5 Ton complete all as specified and directed by Engr-in-charge (as per sample approved by GE).
Taking out old existing reversible type unserviceable inner unit of split type AC of capacity 1.5/2.0 Ton and supply and fix new inner unit of split type AC of capacity 1.5 /2.0Ton as existing shape, size and make complete all as specified and directed by Engr-in-Charge. Make : Godrej, Carrier, Bluestar, Voltas.Hitachi.LG.
Taking out old existing reversible type unserviceable outer unit of split type AC of capacity 1.5/2.0 Ton and supply and fix new outer unit of split type AC of capacity 1.5 /2.0Ton existing shape and size without compressor complete all as specified and directed by Engr-in- Charge. Make :Godrej, Carrier, Bluestar, Voltas.Hitachi.LG.
Disconnecting from electrical system carrying to workshop & back to store/site after repair dismantling the voltage stabilizer of capacity 7.5KVA, 5KVA, 2KVA, 1KVA, 0.5KVA throughly checking, cleaning all parts by brushing and re-assembling after repalcement of required burnt unserviceable parts / componenets, testing and comminssioning complete after necessary repair/replacement of components as below:-
Rewinding of main coil (primary/secondary) with super enameled copper wire of existing size including varnishing and insulation material of capacity 7.5KVA.
Description all as per ser item No.28.01 here-in-before but for DG set of capacity 5KVA.
Description all as per ser item No.28.01 here-in-before but of capacity 2KVA.
Description all as per ser item No.28.01 here-in-before but of capacity 1KVA.
Description all as per ser item No.28.01 here-in-before but of capacity 0.5KVA.
Replacement of unserviceable relay for 7.5KVA & 5KVA,30amp 24volts DC.
Replacement of unserviceable Step down transformer 24 volts 2Amp for 1 KVA & 7.5KVA.
Replacement of unserviceable circuit plate with connection wire.
Replacement of unserviceable relay for 0.5KVA, 1KVA & 2KVA,16amp 24volts DC.
Replacement of unserviceable Voltmeter 0- 300V, AC 75 Sqm.
Replacement of unserviceable Ampre meter 0- 30Amp, AC 75 Sqm.
Replacement of unserviceable push switch.
Replacement of unserviceable time delay circuit.
Replacement of unserviceable connector switch 30amp 220volts AC.
Replacement of unserviceable 3pin socket 5Amps,240volts.
Replacement of unserviceable 3pin socket 15Amps,240volts.
Water tap internal threaded /external threaded suitable for water cooler complete all as specified and directed by Engr-in - Charge.
Taking out old existing unserviceable cooling coil and supply and fix new cooling coil of existing shape and size suitable for 1.5/2 Ton Split/Window type AC complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable condensing coil and supply and fix new condenser coil of existing shape and size suitable for 1.5/2Ton Split/Window type AC complete all as specified and directed by Engr-in-Charge.
Repair/replacement PCB for LG /Voltas/Loyed/Hitachi/Godrej window type AC 1.5 ton / 2Ton capacity complete all as specified and directed by Engr-in-Charge.
Repair/replacement PCB for LG /Voltas/Hitachi/Loyed/Godrej split type AC 1.5ton/2Ton cap complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable coil Senser and supply and fix new coil senser of existing shape and size suitable for 1.5/2 Ton Split Type AC complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable Senser and supply and fix new senser of existing shape and size suitable for 1.5/2 Ton Split Type AC complete all as specified and directed by Engr-in-Charge.
Taking out old unserviceable blower and supply and fix new blower(plastic body) of 1.5/2.0 Ton Split/Window type AC (as per sample approved by GE) complete all as specified and directed by Engr-in-Charge.
Supply and topping up of refrigerant gas R-22 in Split air conditioner of capacity 1.5/ 2 TR complete all as specified and directed by Engr-in-Charge.
Supply and topping up of refrigerant gas R-410 in Split air conditioner of capacity 1.5/ 2 TR complete all as specified and directed by Engr-in-Charge.
Supply and topping up of refrigerant gas R-600 in Referigerator complete all as specified and directed by Engr-in-Charge.
Supply and topping up of refrigerant gas R-32 in Referigerator complete all as specified and directed by Engr-in-Charge.
Supply and topping up of refrigerant gas R-134 in Water Cooler and Referigerator complete all as specified and directed by Engr-in-Charge.
L -Shape thimble brass in pk(50Nos in one pkt) (in replacement) complete all as specified and directed by Engr-in- Charge.
Thimble brass(50Nos in one pkt) (in replacement) suitable for all type of AC,Water cooler, Referigerator,Deep freezer in pkt complete all as specified and directed by Engr-in-Charge.
Reverse cycle valve (in replacement) for window type AC/ Split Type AC of capacity 1.5 Ton /2.0 Ton including welding, brazing complete all as specified and directed by Engr-in-Charge.
Flexible drain pipe for Window type/Split Type AC of any capacity complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable one and supply and fix new swing motor 0.3HP, 220 volts complete with Louvers, base ,clamps, nuts, bolts of size/shape suitable for 1.5/2.0 Ton Splt/window type AC of capacity 1.5 Ton complete all as specified and directed by Engr-in-Charge. Make:- LG/Voltas/Hitachi/Godrej.
Taking out old existing unserviceable one and supply and fix new hermetic/Rotary sealed unit compressor(rotary type) suitable for window type/split type ACs of capacity 1.5 ton and making connection to suction and discharge pipe(after disconnecting of sealed unit).New sealed unit compressor should be of same make, capacity as per latest new model of same manufacturer with same specifications conforming to original compressor including recharging with refrigerant F-22 , Hydrocarbon Gas, replacement of copper tubing of existing size for suction and discharge and replacing parts with gas brazing and carryout leakage testing with the help of halide torch, soap solution, vacuum pump and rebuilding of standard 800 PSI discharge pressure after creating vacuum with the help of vacuum pump and testing after installation in the system complete all as specified and directed by Engr-in-Charge. Make-LG/Godrej/Hitachi/universal
Taking out old existing unserviceable one and supply and fix new hermetic/Rotary sealed unit compressor (rotary type) suitable for window type/split type ACs of capacity 2 ton and making connection to suction and discharge pipe(after disconnecting of sealed unit).New sealed unit compressor should be of same make, capacity as per latest new model of same manufacturer with same specifications conforming to original compressor including recharging with refrigerant F-22 , Hydrocarbon Gas, replacement of copper tubing of existing size for suction and discharge and replacing parts with gas brazing and carryout leakage testing with the help of halide torch, soap solution, vacuum pump and rebuilding of standard 800 PSI discharge pressure after creating vacuum with the help of vacuum pump and testing after installation in the system complete all as specified and directed by Engr-in-Charge. Make-LG/Godrej/Hitachi/universal
Taking out old existing unserviceable one and supply and fix new hermitically /Rotary sealed unit compressor and making connection of suction and discharge pipe(after disconnecting of sealed unit).New sealed unit compressor should be of same make, capacity as per existing unit of latest new model of same manufacture with same specification conforming to original compressor including recharging with refrigerant gas F-22/R-134A,R-600, Hydrocarbon Gas, replacement of copper tubing of existing size for suction and discharge and changing parts with gas brazing and leakage testing with the help of halide torch, soap solution, vacuum pump and rebuilding of standard 800 PSI discharge pressure after creating vacuum with the help of vacuum pump and testing after installation in the system all as directed by Engr-in-charge for the following sealed units pertaining to Water coolers, refrigerator and deep freezers:-
New sealed unit (compressor) in original suitable for Water cooler of capacity 40/80 Ltr complete all as specified and directed by Engr-in-Charge. Make – Godrej / Blue Star /Voltas
New sealed unit (compressor) in original suitable for Water cooler of capacity 60/120 Ltr complete all as specified and directed by Engr-in-Charge. Make – Godrej / Blue Star /Voltas.
New sealed unit (compressor) in original suitable for Water cooler of capacity 150/180 Ltr complete all as specified and directed by Engr-in-Charge. Make – Godrej / Voltas /Blure Star.
New sealed unit (compressor) in original suitable for 165/170 Ltr Refrigerator, complete all as specified and directed by Engr-in-Charge. Make - Godrej /LG/Voltas.
New sealed unit (compressor) in original suitable for 270 to 290 Ltr Refrigerator, complete all as specified and directed by Engr-in-Charge. Make - Godrej /LG/Voltas.
New sealed unit (compressor) in original suitable for more than 310 Ltr Refrigerator, complete all as specified and directed by Engr-in-Charge. Make - Godrej /LG/Voltas
New sealed unit (compressor) suitable for 320 litres Deep Freezers in original, complete all as specified and directed by Engr-in-Charge. Make : Godrej /Voltas/Blue Star
In replacement and testing of complete new Fan Motor 1/16 HP single shaft for water cooler of same model and type, single phase 230V complete with base and clamps, nuts, bolts main lead as required etc against burnt defective motor complete all as specified and directed by Engr-in-Charge. Make: Air master/Crompton.
Fan motor1/20 HP single shaft for water cooler as per the original make of fan motor complete all as specified and directed by Engr-in-Charge. Make: Air master /Crompton
Fan Motor 1/35HP single shaft for water cooler complete all as specified and directed by Engr-in-Charge. Make: Air master/Crompton
Fan Motor 1/70HP single shaft for water cooler side holder, bushes with main lead complete all as specified and directed by Engr-in-Charge. Make: Air master/Crompton
Fan motor with fan suitable for LG double door 286ltr / 310 Ltr refrigerators (in replacement) complete all as specified and directed by Engr-in-Charge.
Fan motor of 165/170 Litre Refrigerator and supply and fix new fan motor of existing make, shape and size (in replacement) directed by Engr-in-Charge.
All as per Serial item No 63.00 here-in-above but suitable for single door 310 litre Refrigerator complete all as specified and directed by Engr-in- Charge .
Taking out old unserviceable Condensing coil for 165/170 to 310 Litre Referigerator and supply and fix new condenser coil of existing make shape and size complete all as specified and directed by Engr-in-Charge.
Fan Motor (in replacement) of same model and type, single phase 230V complete with base and clamps, nuts and bolts of suitable size etc. against burnt/ defective motor of capacity 1/8 HP double shaft for 1.5 /2.0 Ton window type AC including base, frame, side clamps complete all as specified and directed by Engr-in-Charge. Make: Air master/ Crompton.
All as per Serial item No 66.00 here-in-before but Blower Fan Motor single shaft for Split type AC complete with base, clamps, side holders, rubber bushes complete all as specified and directed by Engr-in-Charge.
All as per Serial item No 66.00 here-in-before Fan motor 1/7 HP for cooling coil of Split Type AC as per the original make of split type AC complete with base, frame, clamps, side holders, rubber bushes with main lead suitable for Voltas/ LG complete all as specified and directed by Engr-in-Charge. Make: Air master/Crompton.
Taking out old existing unsv Starting Capacitor of capacity 50+6 mfd and supply and fix new Multi purpose Running Capacitor of capacity 50+6 mfd for window /split type AC complete all as specified and directed by Engr –in- Charge (as per sample approved by GE).
Taking out old existing unsv Starting Capacitor of capacity 120+150 mfd supply & fix new Multi purpose starting Capacitor of capacity 120/150 mfd for window/split AC complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable Starting Capacitor of capacity 40+80 mfd supply and fix new Multi purpose starting Capacitor of capacity 40/80 mfd for water cooler complete all as specified and directed by Engr-in- Charge (as per sample approved by GE).
Taking out old existing unserviceable Starting Capacitor of capacity 40+60 mfd supply and fix new Multi purpose starting Capacitor of capacity 40/60 mfd for water cooer complete all as specified and directed by Engr-in- Charge (as per sample approved by GE).
Taking out old existing unserviceable Starting Capacitor of capacity 80/100mfd supply and fix new Multi purpose Running Capacitor of capacity 80/100 mfd for water cooler complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable Multi purpose running Capacitor of capacity 45+5 mfd and supply and fix new Multi purpose running Capacitor of capacity 45+5 mfd for window /split type AC complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable Multi purpose running Capacitor of capacity 36+6 mfd and supply and fix new Multi purpose running Capacitor of capacity 36+6 mfd for window /split type AC complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable Multi purpose running Capacitor of capacity 10 mfd and supply and fix new Multi purpose running Capacitor of capacity 10 mfd for water cooler complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable Multi purpose running Capacitor of capacity 4 mfd and supply and fix new Multi purpose running Capacitor of capacity 4 mfd for water cooler complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable Multi purpose running Capacitor of capacity 20 Mfd and supply and fix new Multi purpose running Capacitor of capacity 20 mfd for water cooler complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable thermostate and supply and fix new thermostate for water cooler of any capacity complete all as specified and directed by Engr-in-Charge (as per sample approved d by GE).
Taking out old existing unserviceable Fan Blade and supply and fix new Fan Blade of 1.5/2ton window type AC of any capacity complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable Fan Blade and supply and fix new Fan Blade of 1.5/2 ton split type AC of any capacity complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Repair/replacement of water pump motor of desert cooler including electric connection and testing for better performance complete all as specified and directed by Engr-in-Charge.
Replacement of 'T' junction for desert cooler for watering the three side of the desert cooler with nozzels complete all as specified and directed by Engr-in-Charge.
Replacement of Khas khas set for the doors of desert coolers all as directed by Engr-in-Charge.
Servicing of window/split type air conditioner 1.5 TR capacities of any make by opening the indoor/ outdoor unit ,cleaning the air filter, condenser including complete body of the unit with brush and air blower, washing with cleaning detergent & fresh water ,greasing fan motor ,rectification of loose electric connections and replacement of u/s knobs of electrical items complete all as directed by the Eng-in-Charge.
Disconnecting and taking down unserviceable overload/PTC relay for water cooler ,Deep freezer and referigerator and supply and fix new over load relay/PTC relay and testing for water cooler ,Deep freezer and referigerator satisfactory performance commissioning complete all as specified and directed by Engr-in-Charge.
Disconnecting and taking down unserviceable thermostat from split type AC and supply and fix new thermostat for split type AC 1.5/ 2.0 Ton cap AC and testing the same for satisfactory performance complete all as specified and directed by Engr-in-Charge.
Pressure testing and rectifying leakage in the system of window/split air conditioner up to 2 TR capacity including testing for satisfactory performance, commissioning complete all as specified and directed by Engr-in-Charge.
Copper tubing (in replacement) of existing size for suction and discharge and replacing parts with gas brazing and carryout leakage testing with the help of halide torch, soap solution, vacuum pump and rebuilding of standard 800 PSI discharge pressure after creating vacuum with the help of vacuum pump complete all as specified and directed by Engr-in-Charge.
Cleaning of coils of Window/Split by using alkaline based coil cleaner (Non Acid based) including taking down filters, spraying the diluted alkaline based coil cleaner, leaving it for five minutes and then flushing with running water. Fixing back the filters. Testing & re-commissioning etc.,complete all as specified and directed by Engr –in- Charge. Make: C-Shine
Taking out old existing unserviceable Fan motor 4x4 and supply and fix new Fan motor 4x4 for water cooler of any capacity complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Sub main wiring(in replacement) with two single core PVC insulated, unsheathed copper conductor cable, 1100volts grade of size 4.0 sqmm, FRLS in and including concealed PVC conduit, heavy duty, ISI marked of dia 25mm and thickness not less than 2mm with all accessories such as bends, Tees, elbows, reducer socket, bell mouth,tube ends etc including cutting chases, pinning in masonry walling & making good to facing by pointing / plastering in cement mortar 1:3 to ends or edges for concealed wiring inculding 4.00 sqmm PVC insulated copper conductor cable as earth lead to connecting to the earth dollycomplete all as specified and directed by Engr-in- Charge. Note :- Two run of wire and single run of earth wire 1RM of PVC conduit shall be measured as one unit.
Taking out old existing unserviceable diacharge valve and supply and fix new discharge valve of 1.5/2 ton split type AC complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable suction valve and supply and fix new suction valve of 1.5/2 ton split type AC complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable bush and supply and fix new bush of 1.5/2 ton split type AC make LG/ Voltas complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable filter drier and supply and fix new drier of Split /Window 1.5/2.0 Ton Ac LG. Sidwal, Carrier and Voltas (as per sample approved by GE) complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable capillary and supply and fix new capillary of 1.5/2 ton split type /window type AC complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable dead Nut and supply and fix new dead nut of 1.5/2 ton split type /window type AC complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable NRV and supply and fix new NRV of 1.5/2 ton split type /window type AC complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Remote control unit Suitable for 1.5 / 2.0 Ton split type AC working on both (Hot & Cool) (in replacement) complete all as specified and directed by Engr-in- Charge (as per sample approved by GE) .
Sub main wiring with two single core PVC insulated unsheathed copper conductor cable 1100 volts grade 6.0 Sq mm size HRFR in and including concealed PVC conduit heavy duty ISI marked 25mm dia non metallic with all accessories such as bends, Tees, elbows, reducer socket, bell mouth, tube ends etc. including cutting chases, pinning in masonry walling & making good to facing by pointing/plastering in cement mortar 1:3 to ends or edges for concealed wiring including 4.0Sqmm PVC insulated copper conductor cable as earth lead to connecting to the earth dolly complete all as specified and directed by Engr-in-Charge. Note : Two run of wire and single run of earth wire and 1 RM of PVC conduit shall be measured as one unit.
Repair of Deep frezeer of capacity 320ltr capcity by dismantling the whole condensing as well as cooling coil and finding the leakage /damage portion. Rectify the leakage and damaged parts and vaccume leakage the whole system. Then charging the refrigerent Gas and confriming no leakage. Then reassembling the same deep freezer by providing proper insulation material at the disturbed area complete all as specified and directed by Engr-in-Charge.
Repair /repalcement of broken /water leakage from connection of water cooler of capacity 40/80ltr to 150/150ltrs capcity by dismatiling the front sheet of the water cooler tank, removing the thermocol sheet and doing necessary cutting /welding /brazing work to stop the leakage and make good the damaged portion and fixing of tap connection and reassembling the front sheet including providing the thermocol as a thermal insulation to the water coolers and testing the coolers for no leakage as complete all specified and directed by Engr-in-Charge.
Taking out & re-fixing after repair to roof/building at same location / other location including shifiting where required, of split /window/casttee type AC by making hole, drilling , cutting on wall and necessary gas pipe connection , electric connections and insulations complete all as specified and directed by Engr-in-Charge. Note:- All items including gas, copper pipe and electric cable if required will be measured and paid separately in relevent items of contract.
Taking out okd existing unserviceable foam insulation and supply and fix new foam insulation of 1.5 /2 ton split type /window type AC complete all as specified and directed by Engr-in-Charge. (as per sample approved by GE).
M/S M P Construction Co
proach associates
PREM NATH KHAJURIA AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .