| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC 2ND FLOOR PLOT NO 338 UDHYOG VIHAR PHASE IV GURUGRAM 122015 HARYANA | GURUGRAM | HARYANA | 122015 | ₹1.4 Cr | L1 | Accepted-AOC accepted |
| 2 | L2₹1.4 Cr+₹4.1 L (2.98%)Rejected-AOC TAILOR MARKET MAIN BAZAAR MANDI ADAMPUR 125052 | HISAR | HARYANA | 125052 | ₹1.4 Cr+₹4.1 L (2.98%) | L2 | Rejected-AOC rejected |
| 3 | Rejected-Technical C 311 IIND FLOOR RAMPHAL CHOWK PALAM EXTENSION SOUTH WEST DELHI DELHI 110077 | SOUTH WEST DELHI | DELHI | 110077 | - | - | Rejected-Technical rejected |
| 4 | Rejected-Technical 315 INDUSTRIAL AREA II PANCHKULA 134113 | PANCHKULA | HARYANA | 134113 | - | - | Rejected-Technical rejected |
Tender Value
₹99.6 L
EMD Value
₹2.0 L
Closing Date
6 Jan 2022, 5:00 pmClosed
Executive Engineer
Electrical Division PWD BnR Br. Rohtak
Up-gradation of Civil Hospital Bahadurgarh (Jhajjar) from 100 Bedded to 200 Bedded (Providing CCTV, LAN, EPABX, Fire Alram, Public Address, Information Display and Audio Video System only)
2021_HRY_200432_1
PWD/Electrical/212747
Open Tender
Electrical Works
Item-rate/Agreement basic
60 days
Jhajjar
Please refer to tender documents as per DNIT conditions.
3 documents required · 3 mandatory
₹5,000
₹2.0 L
Yes
18 Apr 2022
17 Dec 2021
7 Jan 2022
17 Dec 2021
6 Jan 2022
17 Dec 2021
Amount
FIRE ALRAM SYSTEM
SITC of Micro processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel (having nos. of loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80 LED Indicators. The Panel shall have 3 Serial Ports. The pane\l shall have a built in power supply and battery charger along with maintenance free 24 AH,2 x 12 volt SMF lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS/ as per specifications complete in all respect up to the entire satisfaction of Engineer - in – charge of work. Make: Bosch FPA 2000 / Cerberus by Siements / Edwards EST3 / Honeywell Morley ZXE Series
SITC of 6 watt ceiling / wall mounted speaker complete in all respect. Make:-Bosch / Honeywell / Morley ZXE
SITC of Analog Addressable type Active Repeater fire alarm panel with Backlit LCD Display, having controls for reset, mute, Accept, Silence alarms and self test conforming to BS5839 standards and Duly approved by EN54/UN54/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make :- Bosch / Siemens Cerberus / Honeywell / Edward
SITC of addressable multisensor detector with a combination of optical and thermal including base, auto addressing features as required. Detectors should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elemnets in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance wiht EFSG agreement EFSG/F/97/005. EMC safety for detector shall be 50 V/m. shall be EN54/VDS/UL certification. ((Detectors without inbuilt isolators may be considered with an additional isolator module after 20 devices) Make: Bosch 425-OT, Siemens Cerberus, Honeywell Morley, Edwards SIGA PHD
SITC of addressable Heat Detector wht fixed and rate of raise feature including mounting base with LED etc complete as required. Each detector should have 2 as per NFPA 72 style 7 wiring requirement (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to eletrmagnetic effects in accordance with EFSG agreement EFSG/F/97/005. Detector should monitor electromagnetic interfarence and report to the panel-current and average values, EMC safety for detector shall be 50 V/m. shall be EN54/VDS/U: certification. (Detectors without inbuilt isoaltors may be considered with an additional isolator module per detector. Make: Bosch, Siemensr Cerberus, Honeywell, Morley, Edwards
SITC of UL/EN54/LPCB listed and FM approved line isloating for isolation the section of circuit in case of short in the addressable loop wiring complete in all respect. (Make: Bosch / Siemens Cerberus / Morley / Edwards)
SITC of intelligent analog addressable type Manual Call point having surface or flush mounting option fully compliant to EN54 having rotary decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Make Siemens cerberus/ Morely/ Edwards / Bosch
SITC of addressable Loop powered hooter with strobe complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required complete the ob in all respect upto the entire satisfaction of Engineer - in - charge of work. Make Bosch/ Morley/ Siemens/ Cerberus/ Edward
SITC of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink sulphate as bare chemical class 1 material PSPA fixed on 3mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener incluing all accessories upto the entire satisfaction of Engineer-in-Charge of the work. Make:- GLOLITE / PEARL / DEVI
SITC of Intelligent Analog Addressable type Response Indicator with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in - Charge of work Make: Bosch / Siemens Cerberus / Morley / Edwards.
SITC of Addressable Control Relay Module with flexible network structures with a maximun switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification Makes :Bosch /Siemens Cerberus / Morley / Edwards
SITC of Intelligent Analog Addressable Type Monitor Modules having option of RAIL or Surface Mounting with Tri Color LED status indicator with Built in Short Circuit Isolators having Visible Rotary Decade Address Switch from 01-99 dully approved to GEA GEW1-082 conforming to BS5839 Standards and Duly approved by EN54 / LPCB / VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. Makes: Bosch, Siemens cerberus, Morley, Edwards
SITC of minimum 1000 Mtr. Range Kheraj / National make SIRON generator provided at the roof of the building with separate Power SITC, relay complete in all respect. Make National / Kheraj
Supply and Erection of Fire Extenguishers duly hang on wall with necessary hook complete in all respect. Make: Safex / Minimax / Cease Fire)
i) ABC dry Powder extinguisher 5 Kg Capacity
ii) CO2 type 4.5 Kg Capacity
Supply and erection of PVC unsheathed copper conductor cable two core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe and all other material required to complete the job in all respect to the entire satisfaction of Engineer -in-charge of the work Make :- Havells / Polycab / Finolex
i) Size 1.5 sq.mm
SITC of 5 KVA online UPS with external SMF batteries 12V of suitable AH battery for minimum 2 hour backup complete in all respect Make:- Microtek / EMERSON / Luminous / Libert
SITC of Booster amplifier 980 watts Frequency response: 60 Hz to 15 khz (+1/3db), Inputs :XLR & phone jack , Input 1, Input 2-4, Impendence :20kΩ, Sensitivity : 1 V balanced , S/N >: >85 dB complete in all respect Make /BOSCH/ Henrich/Honeywell
SITC of Horn Loudspeaker 15 watts. Max power 22.5 W, Rated power (PHC) 15 W (15, 7.5, 3.75 W), Sound pressure Level rated power 103dB (At 1kHz, Iw, Im), Effective frequency range (-10dB) 500Hz to 5KHz, Opening angle (at 1 kHz/4kHz,-6 dB), Rated voltage 100V. Rated impedance 667ohm. Ambient temperature range -25 to +55 C .Connection 4 wire cable, 50 cm long complete in all respect Make /BOSCH/ Henrich/Honeywell
Supply, installation, testing & commissioning of 17 U Standard rack to place all Av equipment and Complete in all respect. Make Valrack, Comrack, Hive Networks
Wiring for PA system with the following sizes of FRLS insulated copper conductor single core 1100 volts grade cables in existing surface/recessed M.S. conduit etc. as complete as required. Make Finolex/Havel/Plaza.
i) 2 x 1.5 sq.mm
CCTV SYSTEM
Supply Installation testing commissioning of lmage device/ Sensor - 1/3" Progressive Scan CCD / Progressive Scan CMOS or Better Dome camera Resolution - 2 Megapixel (1920 x 1080) or better Frame rate Up to 30 fps or better Lens Type - 3 to 9 mm auto varifocal lens Motorized IR Light & Distance - Ir Range upto 30 mtrs or better Signal to Noise Raio - >50db Minimum lllumination - 0.3Lx Color; lR LED ON 0 .0 Lux or better Day Night - Auto Day/Night with switchable IR cut filter Video Compression - H.265,H.264,M-JPEG Camera should have Multiple Streaming- Min. Triple Edge Based Analytics Storage - SD Card slot should be expandable up to 128 GB System Compatibitity - ONVlF Profite S&G Privacy Masking - Minimum 4 Privacy zones or higher Protocols - lPv4/lPv6, HTTP, HTTPS, TCP/lP, UDP, UPnP, ICMP, RTSP,RTP, SMTP, NTP, DHCP, DNS, DDNS Additional Features Noise Reduction - Digitat Noise Reduction on/off. WDR -120dB WDR Atarm Input/Output - 1 Alarm Input, 1 ALarm OutPut Audio Input/Output - 1 audio input/1 audio outPut
Operating Environment – lndoor/ Outdoor Operating Temperature -0C to 50 c lngress protection & vandaI resident standards - lP66 or better and IK10 or better UL, FCC, EN complete in all respect upto entire satisfaction Engineer in charge of works. Make: Axis / Bosch / Pelco / Mobotix / Avigilon /Honeywell
Supply, Installation, Testing & Commissioning of lmage device/ Sensor - 1/3" Progressive Scan CCD / Progressive Scan CMOS or Better Bullet cameraResolution - 2 Megapixel (1920 x 1080) or betterFrame rate Up to 30 fps or betterLens Type - 3 to 9 mm auto varifocal lens MotorizedIR Light & Distance - Ir Range upto 30 mtrs or betterSignal to Noise Raio - >50db Minimum lllumination - 0.3Lx Color; lR LED ON 0 .0 Lux or betterDay Night - Auto Day/Night with switchable IR cut filterVideo Compression - H.265,H.264,M-JPEG Camera should have Multiple Streaming- Min. TripleEdge Based Analytics Storage - SD Card slot should be expandable up to 128 GBSystem Compatibitity - ONVlF Profite S&GPrivacy Masking - Minimum 4 Privacy zones or higherProtocols - lPv4/lPv6, HTTP, HTTPS, TCP/lP, UDP, UPnP, ICMP, RTSP,RTP, SMTP, NTP, DHCP, DNS, DDNSAdditional FeaturesNoise Reduction - Digitat Noise Reduction on/off.WDR -120dB WDRAtarm Input/Output - 1 Alarm Input, 1 ALarm OutPutAudio Input/Output - 1 audio input/1 audio outPut
Environment Operating Environment – lndoor/ Outdoor Operating Temperature -0C to 50 c lngress protection & vandaI resident standards - lP66 or better and IK10 or better Certificates: UL, FCC, EN complete in all respect upto entire satisfaction Engineer in charge of works. Make: Axis / Bosch / Pelco / Sony / Mobotix / Avigilon / Honeywell
Supply Installation testing commissioing of IP IR PTZ DOME Camera POE enabled (High Definition) lmage device/Sensor - 1/3" Progressive Scan CCD/ Progressive scan CMOS or better PTZ camera Resotution - 2 Megapixel, 1080p (1920x1080) or better Optical Zoom 30X & Digital Zoom: 12X lR Light & Distance - lR range up to 150 Mtrs. Or better Signal to Noise Ratio - >_50 dB (AGC OFF ) PAN & Tilt travel - Pan 360 endless Tilt 0 to -90 (Auto Flip) Minimum lIIumination - 0.3Lx Color and B/W 0.01Lx Day Night - Auto Day/Night with Auto lR-CUT fitter with auto switch Encoding Video Compression - H.265 MJPEG Triple Stream encoding Frame Rate - Main Frame 30 FPS in all resolution or better Audio Compression - G.711/G.726 Edge Based Analytics Storage - SD Card shoutd be expandabte up to 128 GB Protocols - lPv4/lPv6, TCP/lP, UDP, RTP,RTSP, HTTP, HTTPS, ICMP,SMTP, NTP, DHCP, UPnP, IGMP,SNMP,IEEE 802.1 X System Compatibitity - ONVlF Profite S & G Privacy Zone - Minimum 4 Privacy zones or higher Additional Features Noise Reduction-Digitat Noise Reduction on/off . WDR -90dB True WDR or better Alarm Input,/ Alarm Output-1 Alarm Input, 1 Alarm Output
Audio Input,/ Audio Output-1 Audio Input, 1 Audio Output Environment- Operating Environment-Outdoor Operating Temoerature- 0'C to 50'C lngress protection lP66 or better. Certificates: UL, FCC, EN complete in all respect upto entire satisfaction Engineer in charge of works. Make: Axis / Bosch / Pelco / Sony / Mobotix / Avigilon / Honeywell
NVR / Server with VMS with 24 TB: 1. NVR: for upto 32 Channel, Server in case of more than 32 Channel for Important / Critieal Sites.2. NVR: In case of more than 32 + Cameras: Use RAID 53. NVR: Windows / Linux Based.4. NVR: Should support H.2655. NVR: Onvif profile S&G6. NVR: 32 Channel with min. 3 SATA slot or better, 32 Channel with min. 7 SATA or better.7. NVR: Should be UL, EN, FCC Certified 8. Min. 320 Mbps Total throughput.9. SERVER: Intel Xeon Processor, Min 8 GB RAM or Batter.10. Server: RAID 5/6.11. Server: Window OS12. VMS: Inbuilt MAPS Feature13. Server should have Anti - Virus14. VMS should profile S&G15. Min. 5 Client included16. VMS should be compatible and integrated with 3rd Party Cameras17. Should support H. 26518. VMS should be UL Complaint19. VMS should be compatible and integrated with Edge based Analytics Make: - Axis / Bosch / Pelco / Honewell
SITC of L2 switch with 24 x 1G Base T Port PoE+ with 2 RJ45/SFP combo port and 2 x 1/10G SFP+ .The switch must be stackable upto 4 Units SFP Should be from the same OEM .Switching Capacity should be 90 Gbps or more with not less than 135 Mpps Throughput Switch should have 1GB Flash and 1GB RAM The switch must support minimum 16K MAC address entries and 4K VLAN with latency of less than < 4 µs 802.1AB, LLDP-MED, NTP, DHCPv4 and DHCPv6, ISSU, 802.1D, 802.1W, PVST+, 802.3ad/802.1AX, MVRP Same switch should work with onpremise NMS and Cloud based NMS without change in software and hardware. It should also support automation using JSON, Restful web services and MIB Static Routing for IPv4 and IPv6, Support NAC solutions from all leading vendors, 802.1x, Captive portal, SSH with PKI, TACACS+, Radius, LDAP, ACL, BYOD onboarding using all leading vendors IGMP v1, v2 and v3 snooping with 1000 Multicast groups, UDLD, MLD Snooping, SPQ and WRR, Eight hardware based queues per port, ARP, Mac address lockdown & Learned port security, 370 watt or higher
The switch must support Web-based Management (GUI), SSH v2, SNMP v1, v2 and v3, File upload using TFTP, FTP, SFTP or SCP over Ipv4 and Ipv6 Should support Perpetual PoE to power IoT devices during restart with support for following standards - 802.3af, 802.3at and 802.3bt Switch shall conform to following standards- UL 60950-1 or IEC 60950-1 or CSA 60950-1 or EN 60950 - EN 55022, EN 55024:2010, EN61000-3-2, Class A/B or CISPR22 Class A/B or CE- IEC 62368-1:2018- Certified for EAL 2/NDPP or above Vendor to be present in Gartner Magic Quadrant 5 Years from OEM with Toll free number for support in India. Make: Cisco / Alcatel / Juniper / Netgear.
SITC of CAT6 UTP 24 AWG Patch Cord - 1 mtr with cross separator , Manufactured from stranded wires for longer flex-life , Minimum length of 1m, and maximum length of 5m onforming to the following standards like EN 50173, ISO/IEC 60603-7 & 11801/IEC 60332-1, UL VW-1 and complete in all respect. Make Dlink / Siemon / Systimax
SITC of 24-port 19" 1 U jack panel which Should Be made of sheet steel 1.5 mm, Should be 19" 1U straight Patch Panel, 24-port,Should have integral cable management Metal shelf, Should accept Shielded as well as Unshielded jacks, Should have rear cable management shelf metallic powder coated and complete in all respect. Make (Dlink/W-BOX/Seimon)
Supply Installation Testing & Commissioning of 42/43" LED Monitor, Full HD, 24x7 opration, HDMI Port, Component Video Inputs, 1 Digital Audio Out, VGA Port complete in all respect upto entire satisfaction Engineer in charge of works. (Make: Sony / Panasonic / Samsung)
Supply Installation Testing & Commissioning of three core power Cablea) 1.5 sq. mm (Makes: Finolex / Polycab /Havells)
SITC of CAT 6 UTP Cable. Transmission frequency of 250 MHz (Minimum),cable Should be 4 pair and Cable should be jacket FR PVC Lbp 69% required with certification report and complete in all respect. Make: R&M/AMP/Molex.
Supply installation, testing and commissioning of 1 KVA UPS Online minimum one hour Back up including cost of material wiring, cost of battery stand etc. complete in all respect upto entire satisfaction Engineer in charge of works. (Makes: - APC / Microtek / Libert.)
LAN & EPABX
Supply Installation Testing & Commissioning of 24 Port Switch
L2 switch with 24 x 1G Base T Port PoE+ with 2 RJ45/SFP combo port and 2 x 1/10G SFP+ .
The switch must be stackable upto 4 Units
SFP Should be from the same OEM .
Switching Capacity should be 90 Gbps or more with not less than 135 Mpps Throughput
Switch should have 1GB Flash and 1GB RAM
The switch must support minimum 16K MAC address entries and 4K VLAN with latency of less than < 4 µs
802.1AB, LLDP-MED, NTP, DHCPv4 and DHCPv6, ISSU, 802.1D, 802.1W, PVST+, 802.3ad/802.1AX, MVRP
Same switch should work with onpremise NMS and Cloud based NMS without change in software and hardware. It should also support automation using JSON, Restful web services and MIB
Static Routing for IPv4 and IPv6, Support NAC solutions from all leading vendors, 802.1x, Captive portal, SSH with PKI, TACACS+, Radius, LDAP, ACL, BYOD on boarding using all leading vendors
IGMP v1, v2 and v3 snooping with 1000 Multicast groups, UDLD, MLD Snooping, SPQ and WRR, Eight hardware based queues per port, ARP, Mac address lockdown & Learned port security
The switch must support Web-based Management (GUI), SSH v2, SNMP v1, v2 and v3, File upload using TFTP, FTP, SFTP or SCP over Ipv4 and Ipv6
Should support Perpetual PoE to power IoT devices during restart with support for following standards - 802.3af, 802.3at and 802.3bt
Switch shall conform to following standards - UL 60950-1 or IEC 60950-1 or CSA 60950-1 or EN 60950 - EN 55022, EN 55024:2010, EN61000-3-2, Class A/B or CISPR22 Class A/B or CE - IEC 62368-1:2018 - Certified for EAL 2/NDPP or above
Vendor to be present in Gartner Magic Quadrant Make: Cisco/Juniper/Alcatel/Netgear
5 Years from OEM with Toll free number for support in India
SITC of Layer-3 Switch specs24-Port Giga Managed switch with 4 SFP port802. 1Q VLAN on all ports with support for 4000 concurrent VLANs, and 802.1 AK for dynamic VLAN propagation Support for minimum 64 K MAC addresses System memory: 128 MBShould support Private VLAN , Vlan Q-in-Q and 802.1v upport for 16K OSPF IPv4 and 8K OSPF IPv6 L3 entries in routing table.Number of trunks: 64– Number of queues: 8– Number of static route: 32– Number of routed VLANs: 32– Number of ARP entries: 480– Number of ACL rules: 224– Jumbo frame support: up to 9 K Should support policy based routing, Quality of Service (QoS) FeaturesShould support Diffserv –RFC 2474, RFC 2475 RFC 2597 and RFC 2698Switch should support eight hardware queues per port. Security Features Command Line Interface (CLI) via console port (5 sessions)– Web-based management via embedded HTTP server protected with Secure Sockets Layer– (SSLv3) or Transport Layer Security (TLS v1)– Telnet remote login (5 sessions) securable with Secure Shell (SSH v1.5, v2) hould Support Authentication, Authorisation and Accounting (AAA), UDLD, Private VLANs,TACACS+ command authorisation Tri-authentication: MAC-based, web-based and IEEE 802.1x Should support SSH, SCP-2 and SFTP Management Features Should support CLI ,OOB ethernet management port and USB or External Compact Flash slot IEEE 802.3i 10BASE-T– IEEE 802.3u 100BASE-TX, 100BASE-FX– IEEE 802.3ab 1000BASE-T– IEEE 802.3z 1000BASE-X– IEEE 802.3x flow control Switch should be covered by 24 x 7 TAC support with India Make: Cisco, Juniper, Alcatel, Netgear
Supply Installation Testing & Commissioning of Cat6 UTP Information Outlet -Blue (Data). Should be PCB free and Tool less will be added advantage with halozn free. User Side. As per specification. Make & Model: R&M/AMP/Molex.
Supply Installation Testing & Commissioning of 2-port with dust cover faceplate including back box and all other accessories As per specification. Make & Model: R&M/AMP/Molex.
Supply Installation Testing & Commissioning of Cat6 Patch Cords - 1Mtr -Blue (Data Rack Side), As per specification. Make & Model: R&M/AMP/Molex.
Supply Installation Testing & Commissioning of Cat6 Patch Cords - 2Mtr -Blue ( Data Field Side), As per specification. Patch cord should have provision of lock with information outlet port. Make & Model: R&M/AMP/Molex.
Supply Installation, testing and commissioning of Indoor soft jelly filled SINGLE MODE 6 CORE - OS2 . Should be ISO.IEC 11801 type OS2 and ITU-T REC G 652D. Tube Idenification :Single tube. Fibre protection (Tube) : Polybutylene Terephthalate (PBT). Water Blocking :Thixotropic Gel (Tube) and Petroleum Jelly (Interstices) with cotton poly thread protective. Core Wrapping : Polyethylene Terephthalate with cotton paper guard protection : Corrugated Steel Tape Armour (ECCS Tape). Strength Member: soft protetective periphery /Central S. Sheath : UV Stabilized Polyethylene (HDPE). Maximum. Tensile Strength-Short Term : 400N or better. Mass (Nominal) : minimum 50 kg/km Optical fiber cable with jelly filled 6F Loose Tube ( Unitube ) Type CSTA SM FOR SERVER ROOM to Each Network Rack Backbone connectivity As per specification. Make & Model: R&M/AMP/Molex.
Supply Installation Testing & Commissioning of 12F, 1U, LC OM3, LIU Loaded with Pigtails, Splice tray, LIU have slider channel for rack mount. It has spindle with fiber management accessories. As per specification. Make & Model: R&M/SIMON/Molex.
Supply Installation, testing and commissioning of PATCH CORD LC-LC MM OS2 DUPLEX LENGTH- 2mtr. It has covered with metal outer sheath for antirodent protection As per specification. Make & Model: R&M/SIMON/Molex.
Supply Installation & Commissioning of 9U Rack for Network Switch with all necessary accessories, civil, electrical works & peripheral items and complete in all respect. Make & Model: Valrack/NN/Comrack.
Supply and erection of 1000-Base SM SFP fiber module of same OEM quoted for switch and complete in all respect
Splicing and testing of fiber core with digital report of OFC performance and complete in all respect.
EPABX Systems: Supply Installation Testing Commissioning of IP PBX with Configuration, User expandable upto 240 ports line with following configuration: 30 Analog Users 04 digital users Systems should support ISDN PRI 04 Analog Trunks 01 Operator Console a) Remote maintenance Facility b) Web Based Management Software c) Call Accoounting Software -01 d) DISA & DOSA Facility e) Wall / Rack Mountables System f) Call Control Server / Application should be equipped with Intel / Pentium Based Processor including cost of all material and Labour required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work. TEC Certification is required Make: Matrix / Cisco / Avaya / Siemens (Unify) / Alcatel
SITC of 24 Port Layer 2 POE Access Switch Make: Cisco/Alcatal/Juniper / Netgear.
Switch should have 24-port 10/100/1000 Base-T (Auto Uplink on all ports) and 1x USB port for external USB flash
Switch should have 4-Port 100/1000 SFP slots/Ports should work simultaneously along with 24 Nos of 1G Base T port
Switch should have Minimum 65Gbps Switching Capacity and 50 Mpps Forwarding rate.
Switch should support min 16K Mac address or More.
Switch should support min 2500 Active VLAN.
Switch should support IEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Fast Ethernet, IEEE 802.3ab 1000BASE-T Gigabit Ethernet, IEEE 802.3bz, IEEE 802.1ba, IEEE 802.3x full-duplex flow control, IEEE P802.1Qaz
Switch support IEEE 802.1D Spanning Tree Protocol, IEEE 802.1W Rapid Spanning Tree Protocol, IEEE 802.1S Multiple Spanning Tree Protocol, IEEE 802.3ad static or dynamic link aggregation (LACP), G.8032
Switch should have QOS and Q-in-Q from day 1.
Switch should have IGMP Snooping, , MLDV1/MLDv2, IGMPV1/v2/v3 from day 1.
Switch should support Jumbo Frame Support (up to 9 KB)
SNMP v1, v2c, v3,RFC 1643 Ethernet Interface MIB, RFC1493 Bridge MIB
IEEE 802.1Q Tag VLAN, IEEE 802.1v: VLAN classification by Protocol and Port, IEEE 802.1p (Class of Service), DiffServ, 8 Queue per port, Layer 2/3/4 Access Control Lists (ACLs)
Switch should support static routing and PBR from day 1.
Switch should support atleast 1000 Multicast entries and Ingress Access list Rules.
Switch should have MAC and 802.1 X based Login, Fallback to local authentication database (MAC and Web-based methods), Access Policies for Telnet/ SSH-2/SCP-2
Switch should support MAC Address based Lockdown and Limited Learning.
Switch should support DHCP client function,Port mirroring (many-to-one), Application Telemetry, Auto denial-of-service (DoS) prevention
Following in-band management methods shall be available: Web based management (On http or https), SSH based management (SSH v2).
Following out-of-band management methods shall be available: Console port and Out of Band Management Ethernet Port.
AAA using RADIUS/TACACS+ must be available
Syslog shall be supported with multiple syslog destinations for Log Management.
Shall support Netflow/ IPFIX/ sflow or equivalent for flow exports.
Time synchronization using Network time protocol must be available.
Switch Should support RMON 4 Group.
Mean time between failures (MTBF): 500,000 hours
Operating temperature: 32° to 113°F (0° to 45° C)
Storage temperature: -40° to 158°F (-40° to 70° C)
Operating humidity: 10% to 95% maximum relative humidity, non-condensing
Certifications:- FCC CFR 47 part 15 Class A, EN 55032 Class A, RoHS, WEEE, EN 55024, UL 60950-1, EN 60825-1Class 1, CE 2.0, IEC 61000-4-5 /EN 61000-4-5, IEC/EN 61000-4-11, EN 300386, IEC 62368-1
All the switches, the fiber modules should be from the same OEM for seamless integration with existing running network and infrastructure. The OEM should have 24x7 TAC center with L1, L2 and L3 Support.
OEM should have India toll free number reflected on official website.
Switch should have 2 Year NBD 24x7 Tac support.
SITC IP-Phone with 2 SIP lines support POE and required external POE adaptor for the same. Phone has caller ID screen with call forwarding feature and complete in all respect. Make Matrix/Alcatel/Unify.
SITC IP-Phone with 1 SIP lines support POE and required external POE adaptor for the same. Phone has caller ID screen with call forwarding feature and complete in all respect. Make Matrix/Alcatel/Unify.
Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall /ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work Make AKG / Kalinga / Diplast
i) 25 mm dia
INFROMATION DISPLAY
Supply Installation Testing & Commissioning of Professional Display 43" Diagonal Size 43 Panel Type Edge LED BLU Resolution UHD (3840 x 2160) Brightness 400unit Contrast Ratio 4000:1 Viewing Angle(H/V) 178:178 Response Time 8ms Display Colors 1.07 Billion Color Gamut 72% Dynamic C/R MEGA Audio Built in Speaker(10W + 10W) INPUT Type DVI-D,HDMI 2.0 X 2,USB 2.0 x 1 , Audio Input X 1 OUTPUT Type Stereo Mini Jack, HDMI X 1 Duty Cycle 24 x 7 Special features Anti Glare/ Haze 25%, Temperature Sensor, Pivot Display, IP5x Rating, Wireless Mirroring, 8GB internal memory Logo Should have Customized Logo when no signal is active File support Direct viewing of PPT, Word ,PDF, Images and video from pen drive Remote Controlling of device Laptop / Desktop Should be controlled remotely by external Keyboard and mouse through display EXTERNAL CONTROL RS232C(in) thru stereo jack, RJ45 Power Consumption 110 Standby Mode Power less than 0.5W VESA Mount 200*200mm Operating Temperature 0℃~ 40℃ Humidity 10~80%Safety CE, FCC, Energy Star 8.0, BIS. Make: Panasonic / Samsung / Sony.
Supply Installation Testing & Commissioning of Digital signage media player : CPU Octa-core amlogic S912 ARM Cortex-A53, GPU/ Graphics Mali T-820 MP3 OpenGL ES 3.2, OS Android 6.0.1, Memory 2GB DDR3, Storage 32 GB, Wi Fi 802.11/b/g/m with 2dB antena, Ethernet 10/100 Mbps, Bluetooth 4.0, O/P Ports HDMI 2.0,USB 2 USB 2.0 ports , SD SD card slot, support up to 32 GB, Resolution 3840 x 2160. Make: Sony/Samsung/Panasonic.
Supply Installation Testing & Commissioning of MS office software for media player and complete in all respect.
Supply Installation Testing & Commissioning of PC Client Intel i7 processor (for workstation) with clock speed- minimum 3.0GHz, RAM8 GB & Expandable. Window 8/10. Minimum 1TB (For Workstations)With Read & Write functions . LAN Interface 10/100 Mbps Ethernet. 2GB graphics card. Mouse Optical . USB port and complete in all respect. Make: HP, Dell, IBM.
Supply Installation Testing & Commissioning of Central Server MagicInfo Premium Server software for digital signage Content Pushing and complete in all respect.
Supply Installation Testing & Commissioning of 8 port 10/100/1000 non POE switch and complete in all respect. Make: D-link/Cisco/Extreme
Supply & laying of 1.5 m HDMI cable and complete in all respect. Make: Kramer/Extron/AMX
Supply, installation, testing and commissioning of Composite Audio Cable 14/38 multi Stranded 2 Core double insulated 3 Mtr and complete in all respect. Make:- CHETAN/ASIAN/DEEPCAB
SITC of 2 KVA UPS with 1 hour backup on line with Suitable AH batteries complete in all respect. Make: Microtek / Luminous / Emerson / Libert
Prime Computers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .