GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/REPLACEMENT INCLUDING MISC WORK OF WALK-IN-COOLER, LT PANEL, DEEP FREEZER ETC AT VARIOUS LOCATION IN THE AREA OF AGE E/M EXT (WS) UNDER GE E/M LUCKNOW
2020_MES_404750_1
GE/EM/LKO/EXT(WS)/T-73 OF 2020-2021
Open Tender
Miscellaneous Works
Item Rate
180 days
Lucknow
Class D or above category c (i)
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹85,000
Yes
10 Mar 2021
18 Dec 2020
18 Jan 2021
18 Dec 2020
16 Jan 2021
4 Jan 2021
Amount
Servicing and overhauling of walk in cooler of any make and of size 19950 litre make Blue star Model - PC 1950 with 10 Nos strainer steel product and with two condensing unit installed at any location in cantonment including cleaning and painting internally and externally with two coats of synthetic enamel paint ; reparing/ renewal/replacement of defective parts and component complete all as specified and as directed by Engineer-in-Charge. Parts renewed shall be measured and paid separately under appropriate items
Taking out unservieable blower motor of capacity 1/8 HP from walk in cooler and rewinding it with super enamelled copper wire of suitable size, testing and reassebling in position complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs Power contactor 3 TF 30 with NO & NC contact , of coil Volatge 220 V complete all as specified and as directed by Engineer-in-Charge. (Make:- L&T / Seimens)
S&F in repairs Power contactor 3 TF 32 with NO & NC contact , of coil Volatge 220 V complete all as specified and as directed by Engineer-in-Charge. (Make:- L&T / Seimens)
S&F in repairs Power contactor 3 TF 47 with NO & NC contact , of coil Volatge 220 V complete all as specified and as directed by Engineer-in-Charge. (Make:- L&T / Seimens)
Taking out the existing unserviceable high & low pressure cut - out switch and supply & fixing new high & low pressure cut-out switch type. MP - 15 complete all as specified and as directed by Engineer-in-Charge. (Make:- INDFOSS / RANUTROL)
Taking out the existing unserviceable low pressure cut - out switch and supply & fixing new low pressure cut-out switch type. MP - 1 complete all as specified and as directed by Engineer-in-Charge. (Make:- INDFOSS / RANUTROL)
S&F ( in repairs) single phase preventor to prevent against single phasing, reverse phasing with wiring & testing complete all as specified and as directed by Engineer-in-Charge. (Make:- Minilec / Electromed / L&T)
Supply only refrigerant gas Non CFC compatible to R-22/R-407/R-410/R-32 in returnable sealed cylinder complete all as specified and as directed by Engineer-in-Charge. (Make:- Floran / Mafron)
Supply & fixing in replacement of water temperature censor for compressor complete all as specified and as directed by Engineer-in-Charge. Make:-Blue Star, model No LCWR-1 - 075, 75 TR Capacity
M&L for renewal of defective water pressure gauge, 0-50 PSI complete all as specified and as directed by Engineer-in-Charge. (Make: Fiebig or as approved by G.E.)
S&F (in repairs) contactor ML-1.5, 3 pole , 415 / 440 volts 25 Amp (Cat No. SS-91851) complete all as specified and as directed by Engineer-in-Charge. (Make:- L&T)
S&F in repairs Contactor ML-3, 3 pole, 415 Volts ,45 Amps rating including necessary electrical connection complete all as specified and as directed by Engineer-in-Charge. Cat No. SS90721 of L&T or equivalent of other specified make..
S&F in repairs Contactor ML-2, 3 pole, 415 Volts ,40 Amps rating including necessary electrical connection complete all as specified and as directed by Engineer-in-Charge. Cat No. SS90701 of L&T or equivalent of other specified make..
S&F thermal overload relay range 10 - 14 amps complete all as specified and as directed by Engineer-in-Charge. (Make:-ABB / L&T)
S&F thermal overload relay range 14-29 amps complete all as specified and as directed by Engineer-in-Charge. (Make:-ABB / L&T)
Dismantling and taking out faulty analog type Ammeter from LT panel and supply and fixing three phase Ammeter digital type upto 0 to 400 Amps with suitable CT's ratio of size 96 mm x 96 mm of any range as required at site including necessary control wire connection and testing complete all as specified and as directed by Engineer-in-Charge. (Make:- Conzerv / L&T / NIPPAN)
Dismantling and taking out faulty analog type Voltmeter from LT panel and supply and fixing three phase Voltmeter digital type upto 0 to 500 Volts with suitable CT's ratio of size 96 mm x 96 mm of any range as required at site including necessary control wire connection and testing complete all as specified and as directed by Engineer-in-Charge. (Make:- Conzerv / L&T / NIPPAN)
Taking out defective Industrial thermometer from water line etc. including disconnecting connection and supply and fixing new thermometer complete with sensor complete all as specified and as directed by Engineer-in-Charge. (Make:- Suraj/Dimle as approved by G.E.)
S&F (in renewal) MCCB-63 Amp, microprocessor release having breaking capacity 10 kA 4 pole AC complete all as specified and as directed by Engineer-in-Charge. (make- L&T, Siemens,ABB C&S)
S&F (in renewal) MCCB-100 Amp, microprocessor release having breaking capacity 10 kA 4 pole AC complete all as specified and as directed by Engineer-in-Charge. (make- L&T, Siemens,ABB C&S)
S&F (in renewal) MCCB-160 Amp, microprocessor release having breaking capacity 25 kA 4 pole AC complete all as specified and as directed by Engineer-in-Charge. (make- L&T, Siemens,ABB C&S)
S&F (in renewal) MCCB-200 Amp, microprocessor release having breaking capacity 25 kA 4 pole AC ccomplete all as specified and as directed by Engineer-in-Charge. (make- L&T, Siemens,ABB C&S)
S&F (in renewal) MCCB- 400 Amp, microprocessor release having breaking capacity 36 kA 4 pole AC complete all as specified and as directed by Engineer-in-Charge. (make- L&T, Siemens,ABB C&S)
Supplying and fixing in replacement, connecting and testing onload change over switch 200 Amps, 4 Pole, 415Volts, AC, SS enclosure including necessary electrical connection of following capacities complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 25 above but 400 Amps, 4 pole, 415 Volts
Supply and fixing in replacement CT fan motor with aluminium alloy fan blade - 04 Nos with hub suitable for existing capacity and for 150 TR cooling tower complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement CT fan motor with aluminium alloy fan blade - 04 Nos with hub suitable for existing capacity and for 50 TR cooling tower complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in repairs PCB with Micro computer Control LCD display suitable for 25 TR Central Ac Plant complete all as specified and as directed by Engineer-in-Charge. Make- Blue Star
S&F (in renewal) MCCB-250 Amp, microprocessor release having breaking capacity 25 kA 4 pole AC complete all as specified and as directed by Engineer-in-Charge. (make- L&T, Siemens,ABB C&S)
Supply & fixing in repairs PCB with Micro computer Control LCD display suitable for 75 TR Central Ac Plant complete all as specified and as directed by Engineer-in-Charge. Make- Blue Star
Collection of unserviceable voltage stabilizers of any make of 4kVA/ 5kVA capacities from AGE store yard & transporting it to local workshop of the contractor, dismantling the stablizer for repairs of the defective parts/ spares & reassembling including repairs of defective screws, rubber shoes, testing & painting with two coats of synthetic enamelled paint after removing old paint and repairs body etc depositing back to MES stores yard complete all as specified and as directed by Engineer-in-Charge. (Note: Spares /parts renewed shall be paid for separately under respective items at appropriate rates).
All as per Item No 32 above but Stablizers of 0.5 KVA capacity.
S&F in repair Relay 25/30 Amps 24 Volt for 4 KVA/ 5 KVA voltage stablizers complete all as specified and as directed by Engineer-in-Charge. Make- Dunmag,Eaglemen,Powerman
S&F in repair Relay 6Amps 18 Volt for 0.5KVA voltage stablizers complete all as specified and as directed by Engineer-in-Charge. Make- Dunmag,Eaglemen,Powerman
Supply and fixing ( in repairs) Main PCB with high & low voltage cut off suiable for 4 KVA/ 5 KVA voltage stablizers of any make complete all as specified and as directed by Engineer-in-Charge. ( Make:- Blue birds/ Hitech)
Supply and fixing ( in repairs) Main PCB with high & low voltage cut off suiable for 0.5 KVA voltage stablizers of any make complete all as specified and as directed by Engineer-in-Charge. ( Make:- Blue birds/ Hitech) .
S&F ( in repairs) 2 Metre long copper conductor cable 3 core PVC insulated and sheathed 80 / 0.20 ( 2.5 sqmm)size duly fitted with 3 pin top, 20 Amps ( Cat No. 38637 of Anchor or any equivalent specified make complete all as specified and as directed by Engineer-in-Charge.
S&F ( in repairs) 2 Metre long copper conductor cable 3 core PVC insulated and sheathed 24 / 0.20 (0.75 sqmm)size duly fitted with 3 pin top, 20 Amps ( Cat No. 38637 of Anchor or any equivalent specified make complete all as specified and as directed by Engineer-in-Charge.
S&F (in repairs ) power transformer suitable for Voltage stabilizer of make Blue Bird / Vinitec / Servel suitable for 4kVA/ 5kVA capacity stabilizer duly winded with suitable size super enamelled copper wire and testing complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 40 above but 0.5 KVA.
S&F in repair AC volt meter, square/round type, 0-300 volts suitable for 8 KVA / 4 KVA / 5 KVA / 0.5 KVA single phase voltage stablizer complete all as specified and as directed by Engineer-in-Charge.
S&F (in repairs ) trigger transformer suitable for 4/5 KVA Voltage stabilizer of make Blue Bird / Vinitec / Servel duly winded with suitable size super enamelled copper wire and testing complete all as specified and as directed by Engineer-in-Charge.
Supply only connector for in - out supply of voltage stablizer, 15 Amp with earth connection complete all as specified and as directed by Engineer-in-Charge.
Taking out carefully 325 to 500 mm sweep desert cooler from its existing position from stand or pillar, removing the side panels, taking out cut wood pads or loose pads and disposed to a distance not exceeding 50 metres away as directed by EIC and spray painting with synthetic enamel paint of approved color (inside and outside) after preparation of old painted surfaces and reassembling and fixing in position including renewal of new wood pads complete all as specified and as directed by Engineer-in-Charge.
Repairing of leakage of tank by brazing/soldering of any size of desert cooler, testing the leakage water complete all as specified and as directed by Engineer-in-Charge.
Renewal of PVC front grill complete all as specified and as directed by Engineer-in-Charge. ( Make Orient/ Anchor or equivalent of other specified make)
Renewal of control switch/dimmer electronic 650 watt complete all as specified and as directed by Engineer-in-Charge. ( Make :- Anchor or other specified make)
Renewal of of control switch/slector switch suitable for desert cooler complete all as specified and as directed by Engineer-in-Charge. ( Make :- Anchor or other equivalent of Orient or specified make)
Renewal of set of panels made out of PGI sheet 22 gauge thick with wood wool pads, in required quantity duly filled complete all as specified and as directed by Engineer-in-Charge.
Renewal of sprinkle pipe, PVC heavy duty 15 mm dia with tee, elbow etc. for 24"/18" sweep desert cooler complete all as specified and as directed by Engineer-in-Charge.
Renewal of PVC distributor suitable for 15 mm dia PVC Pipe, PVC elbow & connection of PVC pipe from pump to distributor suitable for 18"/24" sweep desert cooler complete all as specified and as directed by Engineer-in-Charge.
Renewal of desert cooler body, suitable for 450 mm/500 mm sweep exhaust fan /kit, made out of 22 gauge PGI sheet with front grill and side panel with switch regulator and spray painting (double coat) with synthetic enamel paint of approved color (inside and outside) complete all as specified and as directed by Engineer-in-Charge. Make ;- Champion or equivalent of other specified make.
Renewal of Polycarbonate Plug top 3 pin16 A .Make :- Cat No.386237/3993of Anchor or other equivalent of specified make) complete all as specified and as directed by Engineer-in-Charge.
Renewal of Polycarbonate Plug top 3 pin 6 A .Make :- Cat No.386226/3982of Anchor or other equivalent of specified make) complete all as specified and as directed by Engineer-in-Charge.
M&L for renewal of vertical water lifting pump, single phase, 230 volt AC, 50 HZ 1/60 HP, 1.5 meter head complete all as specified and as directed by Engineer-in-Charge. (Make:- Jyoti / Champion / Summer Cool)
M&L for renewal of horizontal water lifting pump, single phase, 230 volt AC, 50 HZ, 1/40 HP, of 5 meter head complete all as specified and as directed by Engineer-in-Charge. (Make:- Jyoti / Champion / Summer Cool)
M&L for renewal of kit fan, motor, single phase, 230 volt AC, 1/3 HP, complete with blade arm 18" sweep size suitable for desert cooler complete all as specified and as directed by Engineer-in-Charge. (Make:- Jyoti / Champion / Summer Cool)
M&L renewal of exhaust fan motor, single phase, 230 volt AC, 1/3 HP, complete with blade arm 18"/20" sweep size suitable for desert cooler complete all as specified and as directed by Engineer-in-Charge. (Make:- Crompton / Khaitan /USHA/HAVELLS /ORIENT)
M&L renewal of capacitor Single Phase , 230 V, AC, of following capacities 2.5 MFD complete all as specified and as directed by Engineer-in-Charge.
All as per item No 60 above but 4.0 MFD.
Taking out defective burnt exhaust fan of following sweep and of any make and transporting to contactor's workshop, opening of exhaust fan/taking out rotor and cutting out the burnt winding and cleaning the slots and rewinding of the same with the existing size of super enameled copper winding wire including insulation varnishing, greasing, reassembling testing and fixing in position 18"/24" size (exhaust fan) complete all as specified and as directed by Engineer-in-Charge.
All as per item No 62 above but 18"/20" (Kit fan)
M&L for fabrication of mild steel stand made out of MS angle iron and flat grade Fe-290-Gde E-165 of size as directed suitable for positioning the desert cooler / stablisers including painting with two coat of (black) enameled paint over a coat of red oxide primer and installed at locations complete all as specified and as directed by Engineer-in-Charge.
M&L( in repairs) for PVC connection 15 mm dia with brass ferule both and length 450 mm complete all as specified and as directed by Engineer-in-Charge.
S&F( in repairs) PTMT float valve , 15 mm dia complete all as specified and as directed by Engineer-in-Charge. (Make Prayaga)
S&F (in repairs ) copper conductor twin core PVC insulated and sheathed cable size 1.50 sqmm ISI mark for pannel wring of desert cooler complete all as specified and as directed by Engineer-in-Charge.
S&F (in repairs ) copper conductor three core PVC insulated and sheathed cable size 1.50 sqmm ISI mark for pannel wring of desert cooler complete all as specified and as directed by Engineer-in-Charge.
M&L for PVC pipe heavy duty 15 mm dia for desert cooler pump to distributor complete all as specified and as directed by Engineer-in-Charge.
M&L for PVC pipe heavy duty 20 mm dia for desert cooler pump to distributor complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement submersible pump for desert cooler single phase, 1/40 HP, 230 volts complete all as specified and as directed by Engineer-in-Charge. Make- TULLU/KSB/JYOTI)
S& F in repair Exhaust fan blades 18"/20" sweep heavy duty (as per sample) complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Khus pad (As per sample) suitable for desert cooler 16" / 24" sweep complete all as specified and as directed by Engineer-in-Charge.
S&F in repair wood wool (As per sample) suitable for desert cooler 24" sweep complete all as specified and as directed by Engineer-in-Charge.
S&F (in repairs) wood wool pad (As per sample) suitable for desert cooler 325 mm to 500mm sweep complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs worn out wiremesh rectangular / square fitted with all the three side panels of desert cooler of 15"/24" any make made out of 24 SWG 10mm aperture including rivetting and renewing the cut wood pads complete all as specified and as directed by Engineer-in-Charge. (Renewal of Wood pads shall be measured and paid separately).
Disconnecting ACs,Water Coolers,Refrigerators,Deep freezers and Voltage stabilizers and fixing only spares required to make it fully functional in all respect and handing over the report from all units duly signed by the user by name to concern JE complete all as specified and as directed by Engineer-in-Charge. (Spare parts shall be measured and paid separately under appropriate items)
M&L for renewal of starting capacitor of 100-120 Mfd capacity mfd in plastic container complete all as specified and as directed by Engineer-in-Charge.
M&L for renewal of starting capacitor of 80-100 Mfd capacity mfd in plastic container complete all as specified and as directed by Engineer-in-Charge.
M&L for rewal running capacitor of capacity 36 Mfd in plastic container complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of running capacitor of capacity 50+5Mfd in plastic container complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of starting relay for 1.5 TR / 2 TR compressor complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of overload protector for 1.5 TR / 2 TR compressor complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of Air Censor for temperature control for 1.5 TR / 2 TR compressor complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs Thermostate switch for 1.5 TR / 2 TR Window type AC complete all as specified and as directed by Engineer-in-Charge. ( Make :- Carrier/ LG/Voltas/National/Casino type)
S&F in repairs Swing motor for 1.5 TR / 2 TR indoor unit of split type air conditioner complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs Swing motor for 1.5 TR / 2 TR window AC complete all as specified and as directed by Engineer-in-Charge. ( Make :- LG/Carrier/Voltas/LG).
S&F ( in repairs) suction copper pipe line heavy duty ½” dia with puff insulation and flair nuts from indoor to outdoor unit of spilt AC 1.5 / 2 TR capacity complete all as specified and as directed by Engineer-in-Charge.
S&F ( in repairs) suction copper pipe line heavy duty 1/4” dia with puff insulation and flair nuts from indoor to outdoor unit of spilt AC 1.5 / 2 TR capacity complete all as specified and as directed by Engineer-in-Charge.
S&F( in reapirs) discharge copper pipe line heavy duty 3/8"dia with puff insulation and flair nuts from indoor to outdoor unit of spilt AC 1.5 / 2 TR capacity complete all as specified and as directed by Engineer-in-Charge.
S & F( in repairs) PVC insulated three core stranded copper cable of size 80/0.20 ( 2.5 sqmm) complete all as specified and as directed by Engineer-in-Charge.
S & F ( in repairs) copper Gas filter for AC 1.5 TR / 2 TR capacity complete all as specified and as directed by Engineer-in-Charge.
Taking out defective blower motor from window type AC of cap 1.5/2.0 TR or outdoor unit of Split type AC of capacity 1.5 TR / 2 TR and transporting defective motor of any make & capacity from site to contractor workshop dismantling the burnt winding & rewinding of 1 / 5 to 1 / 8 HP blower motor with the required size of super enameled copper winding wire of suitable gauge including insulation, varnishing, greasing, testing complete and transporting to back to site and refixing complete all as specified and as directed by Engineer-in-Charge.
S & F( in repairs) PVC pipe nylon imbraided 15 mm dia for condensed water drain fitted with clamps/concealed in wall complete all as specified and as directed by Engineer-in-Charge.
Dismantling of existing window type AC. from any location and refixing after doing the following repairs wherever required and as directed by EIC. (a) Servicing & cleaning with liquid soap , cleaning of fins by means of air blower and water with pressure jet and changing of air filter complete with cleaning of Cooling & Condensing coil complete all as specified and as directed by Engineer-in-Charge. (b) M&L for painting of outer cage and front grill window type A/C with two coats of synthetic enameled paint of approved shade and tint including preparation of steel surface by emery paper including writing SM No. / MES No. etc with front of grill complete all as directed by EIC
Taking down old plywood and S&F plywood 6 mm thick,BWR, grade 1, one side decorative teak veneers and other side commercial veneered finished complete all as specified and as directed by Engineer-in-Charge.
Renewal of 2nd class HW (SAL) fillets, cross sectional area excd 3 and not excd 6 sqcm on all four sides of window type AC splayed or chamfered edge including polishing etc complete all as specified and as directed by Engineer-in-Charge.
Dismantling of defective indoor unit of 1.5 TR capacity split type AC and supply and fixing new indoor unit of the same capacity in working condition with blower motor, front grill and all other connected items and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with Non CFC refrigerant gas as required the unit in wall/ceiling mounted complete all as specified and as directed by Engineer-in-Charge. (Make:-Totaline/BlueStar/LG/Voltas/Daikin/Hitachi)
Dismantling of defective outdoor unit of 1.5 TR capacity split type AC and supply and fixing new outdoor unit of the same capacity in working condition with blower motor,fan, and condensing unit of copper, and cabinet and all other connected electricals and items for connecting with indoor unit and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with refrigerant gas as required with stand and installing the unit in wall/ceiling mounted complete all as specified and as directed by Engineer-in-Charge. (Make:-Totaline/BlueStar/LG/Voltas/Daikin/Hitachi)
Dismantling of defective condensing unit ( outdoor unit) of spilt type AC of 1.5 TR capacity and supply & fixing new condensing unit ( except compressor) complete with condensing coil, coil frame, wiring kit and running capacitor, relay, condensing motor with blade complete all as specified and as directed by Engineer-in-Charge. ( Make :- Totaline/ Bluestar/LG/Voltas/Daikin/Hitachi)
S & F ( in repairs) MCB SP -6 to 32 Amps rating to be housed in DBs catered here in after complete all as specified and as directed by Engineer-in-Charge.
S&F in repair plug and socket DBs with single pole MCB rated 32 Amps capacity with socket plug top 2 pin and earth plug complete all as specified including making niche in wall and mounted flush complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs Mettalic Plugs ( top) of AC box 20A, specified make , 2P+E and connecting complete all as specified and as directed by Engineer-in-Charge.
Dismantling of defective cooling coil of 1.5 TR window type AC of any make and S&F new cooling coil for AC, detecting the leakage with N2 Gas, reconnecting in to the system complete all as specified and as directed by Engineer-in-Charge.
Dismantling of burnt indoor motor of 1.5 TR/2.0 TR split AC double shaft ( indoor unit) and supply & fixing new blower motor Suitable for Carrier/Voltas/Blue star/LG/Samsung/Daikin/Hitachi)Make ACs as per sample complete all as specified and as directed by Engineer-in-Charge.
Dismantling of burnt outdoor motor of 1.5 TR/2.0TR split AC single shaft/double shaft (outdoor unit) and supply & fixing new outdoor fan motor Suitable for Carrier/Voltas/Blue star/LG/Samsung Make ACs as per sample complete all as specified and as directed by Engineer-in-Charge.
Dismantling of unserviceable compressors of 1.5 TR capacities including disconnecting suction / discharge copper tubing and S&F new compressor rotary type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as specified and as directed by Engineer-in-Charge. Note : (i)The electrical accessories required will be measured and paid for separately. (ii) The compressor of make – Emerson Model CR-22 / CR-30 or equivalent of Carrier/ Kirloskar/ Blue star
Dismantling of unserviceable compressors of 2 TR capacities including disconnecting suction / discharge copper tubing and S&F new compressor rotary type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as specified and as directed by Engineer-in-Charge. Note : (i)The electrical accessories required will be measured and paid for separately. (ii) The compressor of make – Emerson Model CR-22 / CR-30 or equivalent of Carrier/ Kirloskar/ Blue star
Dismantling of unserviceable compressors of 1.5 TR capacities of window/split type ACs including disconnecting suction / discharge copper tubing and S&F new compressor reciprocating type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as specified and as directed by Engineer-in-Charge. Note : (i)The electrical accessories required will be measured and paid for separately. (ii) The compressor of make – Emerson Model CR-22 / CR-30 or equivalent of Carrier/ Kirloskar/ Blue star
Dismantling of unserviceable compressors of 2 TR capacities of window/split type ACs including disconnecting suction / discharge copper tubing and S&F new compressor reciprocating type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as specified and as directed by Engineer-in-Charge. Note : (i)The electrical accessories required will be measured and paid for separately. (ii) The compressor of make – Emerson Model CR-22 / CR-30 or equivalent of Carrier/ Kirloskar/ Blue star
Servicing of IDU (Indoor unit) of ceiling mounted casset type split Air conditioner of 3/4 TR capacity comprising of Blower, blower motor ,water lifting motor, , & greasing of moving parts complete all as specified and as directed by Engineer-in-Charge.
Servicing of condensing unit comprising of condensing coil, condensing fan and tubing by cleaning condensing coil tighting nuts, bolts, screw and other petty repairs ceiling suspended split AC of capacity 3/4 TR complete all as specified and as directed by Engineer-in-Charge.
Renewal of remote hand set of window type air conditioner of cap 1.5/2.0 TR of existing make with and including pencil cells complete all as specified and as directed by Engineer-in-Charge. (Make:- LG / Samsung / Bluestar)
Renewal of remote hand set of Split type air conditioner of cap 1.5/2.0 TR of existing make with and including pencil cells complete all as specified and as directed by Engineer-in-Charge. (Make:- LG / Samsung / Bluestar)
S&F in repairs flare nuts size 3/8" complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs flare nuts size 1/4" complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs flare nuts size 1/2" complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs ML-1 contactor 240 volt, 25 Amp for split type AC complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs copper capillary of size 0.55/0.60 mm complete all as specified and as directed by Engineer-in-Charge.
S&F ( in repairs) Aluminium fan blade with gun metal bush of blower , Screw complete as per complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ( in repairs) PVC knob of window type AC complete all as specified and as directed by Engineer-in-Charge. (Make LG / Carrier/Voltas)
Supply and fixing in repairs front grill of superior quality for window AC of 1.5 TR/ 2 TR of Make National/ Casmo/LG/Carrier / Blue Star/Samsung complete all as specified and as directed by Engineer-in-Charge.
Dismantling of defective worn out wiring of indoor unit of split AC of capacity 1.5 TR / 2 TR including unserviceable corded electronic remote control, supply and fixing new control wiring and corded electronic remote control to suit / match the existing system complete all as specified and as directed by Engineer-in-Charge. (Make of AC and remote:- ITC / Carrier / Cool Air)
Dismantling of defective worn out wiring of indoor unit of split AC of capacity 1.5 TR / 2 TR including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plate and cordless remote hand set to suit / match the existing system complete all as specified and as directed by Engineer-in-Charge. (Make of AC and remote:-Carrier / LG- HI- SERIES)
Dismantling of defective worn out wiring of indoor unit of split AC of capacity 1.5 TR / 2 TR ( heating and cooling type) including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plate and cordless remote hand set to suit / match the existing system complete all as specified and as directed by Engineer-in-Charge. (Make of AC and remote:-Carrier / LG- HI- SERIES)
Dismantling of defective worn out wiring of window AC/Split ac of capacity 1.5 TR / 2 /3 TR ( Heating/ cooling type) including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plate and cordless remote hand set to suit / match the existing system complete all as specified and as directed by Engineer-in-Charge. (Make of AC and remote:-Carrier / LG- HI- SERIES).
Dismantling of defective worn out wiring of CASSETE Type AC of capacity 3 TR ( Heating/ cooling type) including unserviceable cordless electronic remote control and sensor supply and fixingNEW PCB (Printed circuit Board) & Visual Eye demo plate and cordless remote hand set to suit / match the existing system complete all as specified and as directed by Engineer-in-Charge. (Make of AC and remote:-Carrier / LG- HI- SERIES).
Dismantling of defective worn out wiring of CASSETE Type AC of capacity 4 TR ( Heating/ cooling type) including unserviceable cordless electronic remote control, supply and fixingNEW PCB (Printed circuit Board) & Visual Eye demo plate and cordless remote hand set to suit / match the existing system complete all as specified and as directed by Engineer-in-Charge. (Make of AC and remote:-Carrier / LG- HI- SERIES).
S&F of New Water pump for CASSETE Type AC of capacity 3 TR/4TR including Floate valve and connected items complete all as specified and as directed by Engineer-in-Charge.
M&L for dismantling of defective PCB of 1.5/2.0 TR capacity SplitAC of any make &(cooling only/hot& cold type) from indoor unit and transporting to contractors workshop for repair of the same,transporting back to site & refixing to indoor unit to ensure proper functioning of the AC complete all as specified and as directed by Engineer-in-Charge.
All as per item No 130 above but for 1.5/2.0 TR WINDOW AC
All as per item No 130 above but for 3.0/4.0 TR cassette type AC
Dismantling carefully front cover of indoor unit split type AC of any make & model of capacity 1.5 / 2 TR and disconnecting the water drain pipe for cleaning sludge etc refixing the water drain pipe at its original position of indoor unit including provision of necessary accessories for fixing of drain pipe and testing complete for proper functioning of indoor unit and refixing of front cover complete all as specified and as directed by Engineer-in-Charge.
M & L for servicing of Indoor unit and outdoor unit by means of electric blower & water under pressure ,cleaning & washing of cooling/condencing coil by soap solution or recommended chemical ,, & greasing of moving parts such as blower motor etc complete of 1.5 TR capacity complete all as specified and as directed by Engineer-in-Charge.
M & L for servicing of Indoor unit and outdoor unit by means of electric blower & water under pressure ,cleaning & washing of cooling/condencing coil by soap solution or recommended chemical ,, & greasing of moving parts such as blower motor etc complete of 2 TR capacity complete all as specified and as directed by Engineer-in-Charge.
M & L for Nitrogen pressure testing,flushing out the system by Nitrogen ,vacumrnation and charging of refrigerant gas R-22/R-32/R-410 into the system for 1.5 TR capacity split type AC complete all as specified and as directed by Engineer-in-Charge. (The refrigerant gas R-22 will be provided by Contractor)
M & L for Nitrogen pressure testing,flushing out the system by Nitrogen ,vacumrnation and charging of refrigerant gas R-22/R-32/R-410 into the system for 1.5/2 TR capacity split type AC complete all as specified and as directed by Engineer-in-Charge. (The refrigerant gas R-22 will be provided by Contractor)
M & L for Nitrogen pressure testing Flushing out the system by Nitrogen ,vacumrnation and charging of refrigerant gas R-22/R-32/R-410 into the system for 1.5 TR/ 2 TR capacity Window type AC complete all as specified and as directed by Engineer-in-Charge. (The refrigerant gas R-22 will be provided by Contractor)
Supply & Charging (Top up) the AC unit of 1.5 TR / 2 TR split type AC unit with refrigerant gas R-22/R-32/R-410 in required Qty complete all as specified and as directed by Engineer-in-Charge.
S&F ( in repairs) PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 of size 3 core 6sqmm complete all as specified and as directed by Engineer-in-Charge. Make-Havells or equivalent.
S&F reverse cycle solenoid valve in split type AC 1.5 / 2 TR capacity with necessary extension to suction/ discharge copper tubing & toggle switch complete all as specified and as directed by Engineer-in-Charge.
M&L for Converting the existing AC (window / split) type from cooling system to heating system of the existing AC by using necessary items/ equipments/toggle switch etc. from window/split type of any capacity complete all as specified and as directed by Engineer-in-Charge. ( Excluding reverse cycle valve, which shall be measured separately if required).
Dismantling of wornout base of water cooler fan blower motor of water cooler and S&F new base made out of 450mmx450mm sheet of 16 gauge including welding, rivetting and reinstalling the motor after repairs complete all as specified and as directed by Engineer-in-Charge.
Taking out compressor from water cooler of any make by cutting of suction and discharge lines for carrying out necessary repairs to the water cooler base such as renewal of MS angle iron , base plate, nuts , washers, bolts,compressor rubber grooves and refixing it including N2 flashing and charging of refrigerent with non CFC refrigerant gas matching with R-22 in required quantities and testing of 120/150 litres capacities of water coolers complete all as specified and as directed by Engineer-in-Charge.
All as per item No 145 above but for 40 / 80 Litres capacities of water coolers
Dismantling of unserviceable compressor of any make/brand from water cooler including disconnecting suction / Discharge copper tubing and supply & fixing new compressor (sealed unit) with nuts, bolts, rubbers grommet and washer, connecting copper tubing by welding flare nuts, detecting leak and repairs if any flushing and pressure testing by nitrogen & etc. vacuumising, charging with non CFC refrigerant gas matching with R-22, of 1 TR Capacity ( Make Emmerson Model HR-13) or equivalent of other specified make & Model complete all as specified and as directed by Engineer-in-Charge.
All as per item No 147 above but 1/3 TR capacity Compressor Model No. CAJ 34 G-DE1( KCJ-444HAG-B220 of Emerson)or equivalent of other specified make & Model
Taking out defective blower motor with blade and supply & fixing new blower motor AC 240 volts, 50 HZ single phase, of 1/10 HP capaciites complete all as specified and as directed by Engineer-in-Charge.
All as per item No 149 above but for 1/16 HP capacity
All as per item No 149 above but for 1/8 HP capacity
Taking down and S&F aluminium fan blade of blower motor of 1/16 HP complete all as specified and as directed by Engineer-in-Charge.
Taking down and S&F PVC fan blade of blower motor of 1/8 HP complete all as specified and as directed by Engineer-in-Charge.
Taking down and S&F PVC fan blade of blower motor of 1/10 HP complete all as specified and as directed by Engineer-in-Charge.
Renewal of condensing coil for 150 litres Capacity water cooler of any make complete all as specified and as directed by Engineer-in-Charge.
Renewal of front panel of 60 / 80 litres capacity of water cooler made out of 22 gauge MS sheet of shape and size and providing two coats of spray painting with synthetic enamel paint over a coat of pink primer on all the surfaces of panel including discconeccting required parts and reconecting complete all as specified and as directed by Engineer-in-Charge.
All as above in Item No 156 above but for 150 Ltrs capacity water coolers.
M&L for disconnecting of water cooler of 150 litres capacities from its position, taking out water from its water tank, cleaning of water tank by washing with washing powder and with fresh water externally and internally and spray painting with synthetic enamel paint of approved tint/colour to all painted surface of water cooler of following capacities after preparation of old painted surfaces without disturbing the components & wiring etc. complete and reconnceting complete all as specified and as directed by Engineer-in-Charge.
All as per item No 158 above but for 40 / 80 Litres capacities of water coolers
All as per item No 158 above but for 60 / 120 Litres capacities of water coolers
Checking of leakage in refrigerant system of water cooler of 150 litres capacity by putting nitrogen under pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuumising the system including charging refrigerant gas Non CFC in required quantity complete all as specified and as directed by Engineer-in-Charge.
All as per item No 161 above but for 40 / 80 and 60/120 Litres capacities of water coolers
Supply & fixing (in repairs) starting relay for 1/1/3TR water cooler complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing (in repairs) running capacitor (conforming to IS:2993 - 1975) AC 440 volts in plastic container of 15mfd capacities complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing (in repairs) overload protector for 1.00/1/3 TR compressor complete all as specified and as directed by Engineer-in-Charge.
S & F Thermostat long tail/short tail for water cooler complete all as specified and as directed by Engineer-in-Charge.
Renewal of capacitor for blower motor of water cooler of 2.5/4.00Mfd capacity complete all as specified and as directed by Engineer-in-Charge.
Transporting defective blower motor of 1/ 16 HP capacities from AGE E/M yard to contractor's workshop, dismantling the burnt winding & rewinding of blower motor with the existing size super enameled copper winding wire including insulation, varnishing, greasing, testing and transporting back to AGE E/M yard for refixing at the site complete all as specified and as directed by Engineer-in-Charge.
All as per item No 168 above but for capacity of1/8 HP
Taking down and S&F PVC insulated , copper conductor cable, 3 core of size 48/20 (1.5 sqmm) complete all as specified and as directed by Engineer-in-Charge.
Taking down unsv compressor from the regrigerator and Supply and fixing new sealed unit compressor suitable for 165/190/195 litres refrigerator ( 1/8 TR) capacities , charging with gas and making connections and testing complete all as specified and as directed by Engineer-in-Charge. Make- LG/Whirlpool/Samsung/Godrej)
All as per item No 171 above but for capacity of 286/300/310 ltrs (1/6 TR) refrigrators.(Make-LG/Whirlpool/Samsung/Godrej)
S&F cooling coil of 165/190/195 litres capacities refrigerator after disconnecting the cooling coil from refrigerator, Nitrogen gas pressure testing and flushing out the system and charging of Non CFC gas as per required quantity and testing complete all as specified and as directed by Engineer-in-Charge.
All as per item no 173 above but for capacity of 286/300/310 ltrs (1/6 TR) refrigrators
S&F( in repairs) condensing coil of 165/190/195 litres capacities refrigerator by disconnecting condensing coil from refrigerator, N2 pressure testing and flushing out the system and charging of Non CFC gas as per required quantity and testing complete all as specified and as directed by Engineer-in-Charge.
All as per item 175 above but for capacity of 286/300/310 ltrs (1/6 TR) refrigrators
Checking of leakage in refrigerant system of refrigerator of 165/190/195 litres capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity complete all as specified and as directed by Engineer-in-Charge.
Checking of leakage in refrigerant system of refrigerator of 286 /300/310 litres capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs starting relay, open type for refrigerator of capacity 165/300/310 litres complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs thermostat defrost type for refrigerator complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs thermostat non defrost type for refrigerator complete all as specified and as directed by Engineer-in-Charge.
S&F New PCB for 300/310 ltr refrigerators complete all as specified and as directed by Engineer-in-Charge. (Make-Samsung/LG or others as required)
Dismantling of existing repairable deep freezers of any make and capacity from its position after disconnecting electric connections, transporting from site to Contractor's workshop for carrying out repairs and renewal/ replacements of Parts, reassembling and transporting back to the site including installation of the same on same location and making electric connection etc. complete all as specified and as directed by Engineer-in-Charge. (Note :- Parts renewed shall be measured and paid separately under appropriate item(s) listed herebelow.
Taking down and S&F starting relay for 200/300 Ltr. Capacity deep freezer complete all as specified and as directed by Engineer-in-Charge.
Taking down and S&F over load protector suitable for 200/300 Ltr deep freezer complete all as specified and as directed by Engineer-in-Charge.
Taking down and S&F running capacitor for 200/300 Ltr capacity deep freezer complete all as specified and as directed by Engineer-in-Charge.
Taking down and S&F thermostate suitable for 200/300 Ltr. Capacity deep freezer complete all as specified and as directed by Engineer-in-Charge.
Taking down defective compressor of following capacity of deep freezer of any Make and depositing same in AGE E/M EXT(WS) yard and Supplying and fixing sealed unit compressor as specified here under including brazing and with necessary nuts and bolts, copper filter, capalary and supply & charging of refgn Gas Non CFC in required Qty and testing 200 Litres capacity deep freezer compressor Model No. KCN 372 of Kirloskar complete all as specified and as directed by Engineer-in-Charge.
All as per item No 188 above but 300 Litres capacity deep freezer compressor Model No. KCN 411 of Kirloskar
Checking of leakage in refrigerant system of deep freezer of 200 / 300 litres capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity complete all as specified and as directed by Engineer-in-Charge.
Renewal of Fan Motor with blade of deep freezer, 230Volts rating, AC, Single Phase, 50 Hz including disconnection and reconnecting and testing complete all as specified and as directed by Engineer-in-Charge.
S&F New PCB for 1.5/2.0 TR Split AC Inverter type( hot & cold) complete all as specified and as directed by Engineer-in-Charge. (Make-Samsung/LG or others as required)
M&L for dismantling of defective PCB of 1.5/2.0 TR capacity Split AC inverter type of any make &(hot& cold type) from indoor unit and transporting to contractors workshop for repair of the same,transporting back to site & refixing to indoor unit to ensure proper functioning of the AC complete all as specified and as directed by Engineer-in-Charge.
Shree Tirupati Associates
Ajanta Associates
LUCKNOW REFRIGERATION CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .