| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹24.9 L+₹1.4 L (5.88%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹24.9 L+₹1.4 L (5.88%)Rejected-Finance 266 UTTAMNAGAR NDA ROAD PUNE 411023 | PUNE | MAHARASHTRA | 411023 | L3 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
27 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I R AND D GIRINAGAR PUNE 25
GE I R AND D GIRINAGAR PUNE 25
PROVN OF OVERHEAD SHED FOR ARTILLARY AND AIR DEFENCE GUNS DISPLAYED NEAR BLDG NO P-232 AT MILIT GIRINAGAR AND RENOVATION TO ROOM NO 330 IN BLDG NO P74 AT MILIT GIRINAGAR PUNE
2023_MES_626272_1
GE I R AND D GNR TOKEN 69 OF 2023-24
Open Tender
Civil Works
Works
180 days
GE I R AND D GIRINAGAR PUNE 25
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D GIRINAGAR PUNE 25
₹54,000
Yes
4 Jan 2024
1 Nov 2023
29 Nov 2023
1 Nov 2023
27 Nov 2023
12 Nov 2023
1 Nov 2023 - 6 Nov 2023
Amount
PROVN OF OVERHEAD SHED FOR ARTILLERY AND AIR DEFENCE GUNS DISPLAYED NEAR BLDG. NO P-232 AT MILIT GIRINAGAR, PUNE (B/R PORTION) Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface as in soft/loose soil complete all as specifid and directed.
M&L for cement concrete1:2:4 type B2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed .
S & F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed by Engr-In- Charge.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-In- charge.
M&L for Two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces exc 10 cm width or girth etc complete all as specified and directed.
Supplying and laying of CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors 20mm dia with all fittings and complete all as specified & directed.
All as per item No 6.00 here in before but 16mm outer dia complete all as specified & directed.
S&F bib taps long body cast copper alloy chromium plated ,fancy type with capstan head, screwed down, screwed for CPVC/iron pipe or for brass ferrule 15 mm bore complete all as specified and directed.
S&F Wash hand basin, vitreous China coloured flat back of size 540mm x 360mm x 115mm to 150mm including brass waste coupling, CP bottle trap 32mm size with 250mm & 190mm long wall connection pipe & wall flange, 15mm dia fancy type swan neck pillar taps, cast copper alloy chromium plated fancy type fixed complete all as specified and directed.
S&F for 75 mm dia PVC ( SWR) floor trap with grating including jointing with solvent, PCC complete all as specified and directed.
S&F for PVC (SWR) waste and vent pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of size 75mm bore complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundations filling and mass concrete complete all as specified and directed.
M&L for precast cement concrete block masonry with solid blocks of PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) exc. 10 cm in width and setting in CM 1:6, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified & directed.
M&L for Rendering 15 mm thick on stone/brick/ cement concrete block masonary work/concrete surfaces in cement mortar 1:4 complete all as specified and directed.
Material & Labour for applying Two coats of cement based paint over a coat of primer over old/new surfaces including preparation of surfaces etc complete all as specified and directed.
(E/M PORTION) M & L Point wiring complete with 1.5 sqmm single core PVC insulated and unsheathed cable 1100 volts, FRLS grade with multistranded copper conductor ISI marked drawn through PVC concealed conduit in walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm stranded copper conductor cable as earth continuity conductor and connected to common earth dolly, including modular cover plates with frame and modular flush boxes for mounting for housing the switches, socket outlets, fan regulators etc, all as specified and directed. Note : The cost of cutting chases and making good the disturbed surface to match with existing finishes shall deemed to be included in quoted rates.
(a) One light point controlled by one way switch.
(b) One 3 pin switch socket outlet point 5 Amps on independent board.
All as per item No.19.00 above here in before but with copper conductor cable for one 3 pin socket outlet, 15 amp independent, with cable 2.5 sqmm size complete all as specified and directed.
S & Fix modular switch 1 way 6A, 1 module complete all as specified and directed.
S & Fix modular switch1 way 16A, 1 module complete all as specified and directed.
S & Fix modular socket out let 6A 2/3 on combined 2 module complete all as specified and directed.
S & Fix modular socket out let 6A/16A-2/3 pin combined 2 module complete all as specified and directed.
S & Fix Ceiling rose surface backlite 65x50mm 3 terminals complete all as specified and directed.
S & Fix Batten General purpose industrial compact batten suitable for single or twin LED Tubelight with integral LED driver, available in single / double side connection CRCA batten suitable for mount LED tube rod 1 x 18 watts including necessary electric connections 3 core 1 sqmm insulated copper wire from ceiling rose to tube light fitting complete all as specified and directed by Engineer-in-charge.
S & Fix LED Tubelight (single side connection) with very high efficiency suited for installation in existing tubelight luminaire with G13 lamp holders to give glare free light with necessary fixing arrangement etc complete all as specified and directed by Engineer-in-charge.
S & Fix 300 Watts LED Flood Light Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting. and including required items at site for fixing by growting in or on wall/roof /piller/boundary wall and PCC foundation as per site requirement complete all as specified and directed.
S&Fix MCB DB VTPN 4 ways,with metal double door ,IP -43 protection suitable for MCCB as incommer and MCB as out going, VTPN DB's 415 volt 3 phase complete with appropriate size copper bus bar and neutral link as required at site and including cutting chases to wall for fixing of DB and making good distrubed wall/surface all as required at site complete all as specified and directed by EIC.
Supply and fixing MCCB 4 pole, 100 amps, DPX 160, 25 KA in the DB complete all as specified and directed.
S & Fix of MCB single pole, 240 volts, 6 to 40 Ampere, rupturing capacity 10 KA, ‘C’ series complete all as specified and directed.
S & Fix Metal plug and socket DB's with MCB 20A SP complete all as specified and directed.
S & Fix sheet metal enclosure distribution board SPN DB's 2 way with MCB complete all as specified and directed.
M & L for submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable , multistranded on the surface through and including suitable size of PVC conduit with its accessories all as specified and directed by Engr-in -charge for the following :- (a) 2x2.5 sq mm and 1x2.5 sq mm as earth wire
S & F of Rigid non-metallic PVC conduit of size 20 mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed.
Supply and lay GI pipe 15mm dia “Medium grade” including all fittings complete all as specified and directed.
Supply and Laying in trenches LT underground cable ISI marked 25 Sqmm x 3.5 Core XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc, laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole,making hole in wall as per requirement at site complete all as directed by Eng-in-charge.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth and getting out in Hard / dense or any type of soil including forming bottom surface etc complete all as specified and directed.
Returning, filling in including spreading, levelling ,watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Supply & Laying 40 mm outside dia double wall corrugated pipe (DWC) of HDPE ISI Mark for enclosing cable below ground / road surface, to a required depth, including suitable size coplers for jointing of pipe all as per site requirement complete all as specified and directed.
M &L for GI pipe medium grade, for road crossing / on wall / on pole for cable protection of following size :- a) 40 mm dia
Supply, installation,commissioning & testing of Water cooler fully stainless steel, electric driven single phase having approx storage 80 litres and nominal cooling capacity 40 litres per hour including RO and including one additional suitable size pressure booster pump all as directed. Make : Blue Star / Voltas / Usha or equivalent & approved
M&L for 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass treaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. of size 16mm dia complete all as specified and directed.
Supply and fixing stop valves, cast copper alloy,secrewed down,high pressure with crutch or butter fly handle,fancy type ,screwed both ends for iron pipe or for unions and fixed of size 15mm dia bore complete all as specified and directed.
S & F hose pipe 25mm for drain of water cooler 1.5mtr long all as specified and directed.
Supply and fix PVC Connection 15mm dia 450mm long complete all as specified and directed.
M&L for PCC 1:2:4 type B-2 (using 20 mm graded stone aggregate) for caping of pole / transformer plateform including necessary form work and tiling work complete all as directed by EIC.
M & L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx06mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed. Note : Cost of earth lead and protection pipe upto 7.5 m shall deemed to be included in quoted rate.
RENOVATION TO ROOM NO 330 IN BLDG. NO P-74 AT MILIT GIRINAGAR, PUNE (B/R PORTION) Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets/AC boards, any thickness, including cover fillets complete all as specified and as directed.
S&F of mineral fibre acoustic suspended ceiling system with prima fine fissured tile with semi concealed grid , the tile should have humidity resistance (RH) of 99% , NRC upto 0.6, light reflectance> 83%, thermal conductivity K= 0.052 to 0.057 w/m, colour white fire performance class O/class 1 (BS476 part6 &7) in module sizeof 600x 600x16 mm with Bio block coating on the face of the tile, impact resistant and suitable for green bldg application, eith recycled content of 63 %. The tile shall be laid on semi concealed grid system with 15 mm white flange incorporating 6 mm central reveal in white/black colour and with web height of 38 mm and load carring capacity of minimum 11.68 kg/sqm.Silhouette. main runner and cross tees to have mitred ends & birdmouth notches to provide mitred cruciform junction. The T sections have galvanising of 120 gms/sqm and passed through 500 hrs of salt test. all as per manufacutrer's instructions complete all as specified and as directed. Make : Armstrong, saint Gobain as approved.
Dismantling plain or corrugated steel sheeting any gauge thickness including Nainital or similar pattern roof covering complete all as specified and directed.
S&F 0.63mm thick galvanised,corrugated mild steel sheeting (having 275 gms zinc coating per Sqm of Sheet area) with two corrugation side lap, fixed with L-type or J- type or cranked hook bolts and washers, in roofs, walls etc. complete all as specified and directed.
Taking down shutters of any description exc 1 Sqm but n exc. 2 Sqm each complete all as specified and as directed.
S&F 40 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type both sides (ISI marked) all with 6 mm thick teak wood edging all round complete all as specified and directed.
M&L for 0.9 mm thick decorative laminate type 1,of surface finish, colour and pattern as approved, fixed with approved adhesives as per manufacturer's instructions complete all as specifid and directed.
M&L for brass, sliding door bolt with sand or die cast brass hasp, staple (bolt type) length 300mm fixing bolt with rolled or drawn brass bolts and fixed complete all as specified and directed.
M&L for 200 mm long brass, skelton tower bolts with cast brass plate and staples and rolled or drawn brass bolt and fixed complete all as specified and directed.
M&L for 140 mm long door stopper of brass body and tongue with hard drawn steel spring complete all as specified and directed.
S&F 150mm long extruded brass handles, fabricated type polished complete all as specified and directed.
Demolition of cement concrete in ground floors and paving n. exe 15cm thick below or above GL all as directed & cleaning premises complete all as specified and as directed.
M&L 25mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in sub base of floor complete all as specified and directed.
M & L for double charge coloured vitrified tiles 10mm thick (square/rectangular) of colour and pattern as approved by GE, polished, area of each tile exc. 0.18 Sqm but not exc. 0.36 Sqm as in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of dark shade tiles, laid over and including 15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed.
M&L for double charged vitrified ceremic tiles 10 mm thick (square/rectangular) polished, area of each tile exc. 0.18 sqm not exceeding 0.36 sqm as in skirting/dado etc , laid over and including screed bed of 15 mm thick cement mortar (1:4) and jointed in neat cement slurry and pointed in white or coloured cement to match dark shade complete all as specified and directed.
Dismantling of single layer mangalore tiles roofing including ridges complete all as specified and as directed.
Dismantling the battens of any size incl tiling fillets spaced exc 15cm c/c complete all as specified and as directed.
M&L for second class hard wood clean sawn battens at 30cm centers to center, sectional area exc 5 & n exc 15 Sqcm complete all as specified and as directed.
All as per Item No. 67.00 above but fixing only complete all as specified and as directed.
Material and labour for 2nd class hard wood, clean sawn, in scantling timber work including dismantling work etc all as specified and as directed.
M&L for preparation of surfaces of wood and wood based material new or old of any description and girth and treated with creosote oil etc complete all as specified and as directed.
Material and labour for preparation of battens, any size and spacing and treated all over (measured overall on one side only, spaces not deducted) with two coats of creosote oil complete all as specified and as directed.
M&L for roof tiles, Mangalore pattern, interlocking at side joints, laid dry complete all as specified and as directed.
Laying only mangalore pattern tiles (obtained from taking down) complete all as specified and as directed.
M&L for ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and as directed.
Laying only ridge or hip type Mangalore pattern tiles (obtained from taking down) bedded and jointed in cement mortar 1:6 complete all as specified and as directed.
Taking down cement plaster from brick / concrete/ stone surfaces including racking out joint , hacking for key and scrubing down with water etc all as complete all as specified and directed.
M&L for rendering 10 mm thick on concrete surfaces or surfaces other than fair face of brick work in CM 1:6 finishing surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for Preparation of new/old distembered wall surfaces and applying two coat of oil bound distemper over a coat of approved primer all as specified and directed by Engr-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 sqm but not exc 4.00 Sqm each and removing from site complete all as specified and directed.
S&F three track sliding window with 4mm thick tinted glass in two shutter and one shutter using stainless steel wire cloth 0.36mm nominal dia & 1.18mm width aperture for mosquito proofing including good quality bearing handle, lock, rubber beading and glazing clips etc using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified and directed by Engr-in-Charge. Series of aluminium section as per Jindal is (a) Bottom frame - 20620 (b) Top frame & vertical - 20621 (c) Handle (side) - 20606 (d) Shutter inter lock - 20724 (e) Shutter top & Bottom - 20844 (f) Glazing clips - 19352.
S&F zebra venetion blends with design on inner/outer face alternate blinds, folding type made out of fibre cloth fixed, to wall with necessary Aluminium brackets, screws etc. including Aluminium frame for venition blinds etc. all as approved by Engr-in-Charge and all as specified and directed. Make;- Vista, Levador or equivalent in specified makes as approved.
(E/M PORTION) Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc. complete all as directed by Engineer-in-Charge
Taking down of old unserviceable sub main wiring of any type complete all as specified and as directed.
Taking down carefully unserviceable DBs any type/size With MCCBs/MCBs//Isolator etc and disconnecting and making good disturbed surfaces complete all as directed.
M&L Point wiring complete with 1.5 sqmm single core PVC insulated and unsheathed cable 1100 volts, FRLS grade with multistranded copper conductor ISI marked including PVC conduit and drawn through heavy duty PVC conduit duly concealed in walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm stranded copper conductor cable as earth continuity conductor and connected to common earth dolly, indluding cuttting and chasing, concealed modular flush boxes, modular cover plates with frame mounting for housing the switches, socket outlets etc, all as specified and directed. Note : The cost of cutting chases & maiking good the disturbed surface to match with existing finishes shall deemed to be included in quoted rates.
(a) One light point controlled by one way switch complete all as specified and directed.
(b) One fan/exhaust fan point controlled by one switch and one regulator complete all as specified and directed.
(c) One 3 pin switch socket outlet point 5 Amps on independent board complete all as specified and directed.
(d) One 3 pin switch socket outlet point 5 Amps on same board with other switch complete all as specified and directed.
All as per item above here in before but with copper conductor cable for one 3 pin socket outlet, 15 amp independent, with cable 2.5 sqmm size complete all as specified and directed.
S & Fix modular switch 1 way 6A, 1 module complete all as specified and directed.
S & Fix modular switch 1 way 16A, 1 module complete all as specified and directed.
S & Fix modular socket out let 6A 2/3 on combined 2 module complete all as specified and directed.
S & Fix modular socket out let 6A/16A-2/3 pin combined 2 module complete all as specified and directed.
S & Fix fan regulator electronic 2 modular type volts AC 50 HZ ,4 step complete all as directed.
S & Fix of recess mounted 2' x 2' square LED panel 36 watts, Ultra modern recess mounting luminaire with high performance LEDs, suitable for mounting with Armstrong/Grid ceiling including taking down old U/s light fittings of any type complete all as specified and directed.
Taking down the defective ceiling fan / Exhaust fan of any sweep and make after disconnecting electrically & mechanically and examine & carry out the servicing/overhauling the ceiling fan by thoroughly cleaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing including applying one coat of painting re-fixing, testing in all respect for smooth running complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Five star rated with brushless direct current motor (BLDC) and deposit the old fan to the store complete all as specified and directed.
S & Fix double door sheet metal enclosure distribution board SPN, 8 ways 240 volts, with 200 amps rated bus bar, with IP 43 protection and double door, suitable for mounting MCBs all as specified and as directed including taking down old MCB DB complete all as specified and directed.
S & Fix of MCB single pole and neutral, 240 volts, 6 to 40 Amps, rupturing capacity 10 KA, ‘C’ series includng taking down old U/s MCB of any capacity & type complete all as specified and directed.
S & Fix of MCB single pole, 240 volts, 6 to 40 Ampere, rupturing capacity 10 KA, ‘C’ series including taking down old U/s MCB of any capacity & type complete all as specified and directed.
M&L for submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable , multistranded on the surface through and including suitable size of PVC conduit with its accessories all as specified and directed by Engr-in -charge for the following :-
(a) 2x4.0 sq mm and 1x4 sq mm as earth wire
(b) 2x6.0 sq mm and 1x6 sq mm as earth wire
S & Fix Metal plug and socket DB's with MCB 20A SPN for AC complete all as specified and directed.
S & Fix LAN socket connector RJ 45 with socket with copper feed modular type complete all as specified and directed.
sagar construction
J.G.Goel
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .