Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.1 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹19.0 L+₹1,537.50 (0.08%)Rejected-AOC 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | L2 | Rejected-AOC Rejected being not L1 | |
| 3 | L3₹21.1 L+₹2.1 L (10.8%)Rejected-AOC NO 229 ANGAPPAN STREET MITTANAMALAI AVADI IAF CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | L3 | Rejected-AOC Rejected being not L1 | |
| 4 | L4₹21.5 L+₹2.5 L (13.0%)Rejected-AOC NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L4 | Rejected-AOC Rejected being not L1 |
Tender Value
₹22.4 L
EMD Value
₹44,700
Closing Date
25 Jul 2020, 6:00 pmClosed
Garrison Engineer Avadi
Garrison Engineer, Muthapudupet, Avadi, Chennai 600 055
SPECIAL REPAIRS TO STREET LIGHT AND ALLIED WORKS AND IMPROVEMENT TO ACCOUNT SECTION BLDG AND INTERNAL POINT WIRING AND MISC WORKS AT HQ BLDG AT 23ED AF STATION AVADI
2020_MES_356445_1
8754
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer, Muthapudupet, Avadi, Chennai
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer Avadi
₹44,700
Yes
21 Sept 2020
27 Jun 2020
1 Aug 2020
27 Jun 2020
25 Jul 2020
11 Jul 2020
27 Jun 2020 - 11 Jul 2020
Amount
Taking down old Unserviceable light fitting of any type and Supply and fix LED light fitting 60 W LED, CCT not less 6000K pressure die cast aluminium housing, heat resistance toughened glass with frame IP 66 protection LED lumen efficacy not less then 120 lumen/watt, reflector lenses for uniform light distribution on each LED complete fixed on existing / New bracket and making connections complete all as specified and as directed. Make LUKAR cat part No. LST60 or its equivalent in Philiphs/ Wipro
Taking down old Unserviceable light fitting of any type and Supply and fix LED light fitting 120 W LED, CCT not less 6000K pressure die cast aluminium housing ,heat resistance toughened glass with frame IP 66 protection LED lumen efficacy not less then 120 lumen/watt, reflector lenses for uniform light distribution on each LED complete fixed on existing / New bracket and making connections complete all as specified and directed by Engr-in-Charge.Make LUKAR cat part No. LST120 or its equivalent in Philiphs/ Wipro.
Taking down old Unserviceable Flood light fitting of any type and Supply and fix LED Flood Light 120 W LED, CCT not less 6000K pressure die cast aluminium housing, heat resistance toughened glass with frame IP 66 protection LED lumen efficacy not less then 120 lumen/watt, reflector lenses for uniform light distribution on each LED complete fixed on two nos of angle iron 50x50x6mm and 60cm long with suitable size of holes and nut, bolts and making connections complete all as specified and as directed. Make LUKAR cat part No.LFLSL120 or equivalent in Philiphs/ Wipro
Supply and fix three core copper conductor PVC insulated FR cable of size 1.5 sqmm multistranded 1100 volts grade on old pole from junction box to light fitting complete including taking down old cable all as specified and as directed.
Taking out old existing defective LT Cable of 10Sqmm any core from the trench/pole/wall along with bricks and sand complete removing from site and taken as credit all as specified and as directed. Note: Excavation in trenches for removing cable shall be measured and paid separately.
Material and Labour for XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 volts grade, of cross-sectional area 10 Sqmm, 2 core, laid in trenches/pole/wall complete all as specified and as directed.
Material and Labour for XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 volts grade, of cross-sectional area 10 Sqmm, 4 core laid in trenches/pole/wall complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m.wide and not exc 1.5m depth and getting out in soft/ loose soil for laying of cable etc., complete all as specified and as directed.
Returning ,fillling in including spreading ,levelling,watering and well ramming in layers not exceeding 25cm thick in trenches of soil complete all as specified and as directed.
Removing excavated material/ surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Supply, lay and spread in trenches, dry river sand, clean, including spreading, levelling, punning for cushioning of cables complete all as specified and as directed.
Supply lay in trenches common burnt clay building bricks/ fly ash bricks, old size sub class “B” for cable protection complete all as specified and as directed.
Supply and fix on pole/wall or lay in trenches under road/drain crossings etc for drawing cables and for brackets for fixing street light fitting etc., with GI pipe light grade 40mm dia ISI marked including necessary pipe fittings, clamps, bolts, nuts etc all as specified and as directed.
Taking down old Unserviceable street light timer of any type and Supply and fix Automatic street light timer switch single phase 3kW, 230 V Swadeep-02EC 3 kW1P model as a pole mountable SMC enclosure consisting of Nature Switch-02 as the controlling unit, Power Contactor(s) & MCBs 25 Amps (both Input-Output) of suitable power rating and Copper wiring (min.10 sq.mm.) with proper lugs & terminal blocks. The SMC enclosure comes complete with openable door and mounting clamps. The SINTEX make enclosure is made of UV stabilized, FR grade special moulding compound and it is Rust proof, Electric Shock proof, Termite proof, Outdoor mountable conforming to IP54 .Make : Swadeep-02EC 3 kW1P or its equivalent in Hager/ L&T all as directed.
Material and Labour for point wiring with two single core 4 Sq.mm size multistranded copper conductor FRLSH PVC insulated cables and one single core 4 Sq.mm size green colour FRLSH PVC insulated, multistranded copper conductor PVC cable as earth continuity conductor,1100 volts grade, complete drawn in and including rigid PVC CONDUIT and conduit accessories of size 25mm bore, confirming to IS specifications, Concealed in wall fixing on ceiling/trusses with suitable clamps, screws etc and its accessories including 1.22 mm thick MS terminal boxes with 3 mm thick plastic laminated sheet top cover fixed with cadmium plated iron screws for mounting switches, sockets, fan regulators etc.,including connecting up and testing , all as specified and as directed for one one industrial socket.
Supply and fix Single pole and Neutral enclosure with a two pin socket complete with one single pole MCB 20 Amp complete all as specified and directed.
Supply and Fix non-metallic rigid PVC conduit, 25mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and directed.
Supply and Fixing of Unplasticised PVC pipes of 40 mm bore of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors with connection accessories such as elbow, socket,tee, reducer any type of pipe with suitable clamps etc complete all as specified and directed.
Supply and Fixing of Unplasticised PVC pipes of 25 mm bore of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors with connection accessories such as elbow, socket,tee, reducer any type of pipe with suitable clamps etc complete all as specified and directed.
Cutting of road/Hard standing to a size of 30 cm in width and not exceeding 50 cm in depth for laying of protection pipe for cables, including returning, filling, spreading, levelling, watering and well rammining in layers and providing PCC 1:2:4 type B1 for the top 100 mm layer using 20 mm graded stone aggregate after the pipes/cables are laid complete all as specified and directed.
Supply and Fixing of High density polyethylene pipes (HDPE) of size size 50mm dia of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors with connection accessories such as elbow, socket, tee, reducer etc any type of pipe with suitable clamps etc., complete all as specified and directed.
Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored , electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 4 core complete all as specified and as directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm, 2 core nominal cross section in service connections complete all as specified and as directed.
Supply and fixing for MCCB 3 Pole, 415 V, fixed type, 160 Amps with breaking capacity 16 KA with G frame sheet metal enclosure and accessories complete all as specified. Make : Havells cat part No IHEGTP(enclosure) IHLGNT0160 or its equivalent in Indo Asain/Standard.
Supply and Fix Sub main wiring with two single core of 6 Sqmm and one single core of 6 sqmm as earth wire with multi stranded copper conductor cable PVC (FRLSH) insulated unsheathed cable 1100 volts grade drawn through in non metallic rigid (ISI Marked) PVC conduit of size 25 mm dia and the conduits accessories on wall/ ceiling/trusses etc., complete including making good the disturbed surface to match the existing surface complete all as specified and directed. Note: 2 runs of cable, 1 run of earth continuity conductor and one run of conduit shall be measures as one unit length.
Supply and Fix Sub main wiring with four single core of 10 Sqmm and two single core of 10 sqmm as earth wire with multi stranded copper conductor cable PVC (FRLSH) insulated unsheathed cable 1100 volts grade drawn through in non metallic rigid (ISI Marked) PVC conduit of size 32 mm dia and the conduits accessories on wal/ ceiling/trusses complete including making good the disturbed surface to match the existing surface complete all as specified and directed. Note: 4 runs of cable, 2 run of earth continuity conductor and one run of conduit shall be measures as one unit length.
Material and Labour for brick cutting chasis n exc 10 cm width or girth on exposed surfaces of brickwork such as in splays, chamfers, etc. including rubbed finish and making cement plastering and making good the disturbed surfaces finishng with existing surface all as specified and as directed.
Supply and Fix Distribution boards, sheet metal enclosure, for housing isolators/ MCB's, fixed on wall semi flush, Single Pole and Neutral 8 ways, 240 volts, with hinged type single door all as specified and as directed.
Supply and fix Load line vertical distribution Board, TPN 4 way double door, fixed on wall semi flush, loadline DB are fitted with Bus bars, neutral links, blanking plates, suitable for incoming MCCB TP 100 Amps, and outgoing MCBs all as specified and as directed. Note :- MCCB/MCB for incoming/out goings shall be measured and paid for separately under relevant items.
Supply and fix TPN 4 pole 63 Amps ,10KA, 415V complete all as specified and directed.
Supply and fix MCB single pole 6-40 Amps, 230V complete all as specified and directed.
Supply and fix MCCBs 100 Amps 415V, 16KA, 3 Pole complete all as specified and directed.
Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored , electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 4 core fixed on on wall/ through pipe/ceiling/trusses etc., complete all as specified and as directed.
RK ENTERPRISES
muthu constructions
PSK Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .