Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | Admitted-Finance |
| 2 | Admitted-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | Admitted-Finance |
| 3 | Admitted-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | Admitted-Finance |
| 4 | Admitted-Finance PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | Admitted-Finance |
| 5 | Not Admitted-Fee/PreQual/Technical 1170 BENGALI MOHALLA NEAR PRABHAKAR HOSPITAL AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | Not Admitted-Fee/PreQual/Technical Others-Not enlisted in required category |
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
16 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) FARIDABAD
Garrison Engineer (AF) Faridabad Dabua Colony Faridabad PIN-121005
REPAIR/MAINT OF COOLING APPLIANCES IN TECH AREA AND 415 OFFICER MESS BASANT NAGAR UNDER GE (AF) FARIDABAD (2ND CALL)
2022_MES_511580_2
GE(FBD)/AF-61/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF STN BASANT NAGAR
As per tender documents
10 documents required · 10 mandatory
₹500
GE (AF) FARIDABAD
₹14,000
14 Jun 2022
30 Mar 2022
18 Apr 2022
30 Mar 2022
16 Apr 2022
31 Mar 2022
60 days
Amount
Repair and Maintenance of split type AC's of capacity 1.5/2 TR comprising of the following tasks installed at different locations including testing complete all as specified and directed by Engineer-in-Charge.(a) Inspecting and checking the Indoor/outdoor units for noise free operation (b) Checking the electrical connection for tightness (c) Cleaning the condenser with cleaning agent followed with pressurized water and cleaning the cooling coil with air blower.(d) Greasing/Oiling of condenser fan motor and blower motor. (e)Checking for any refrigerant leakage. (f) Checking for serviceability of remote control unit.
Supply and fixing in replacement of starting capacitor 80-100/100-120 mfd for split type A/C's of capacity 2 TR complete all as specified and directed by Engineer-in-Charge. Make- (1) Tibcon (2) Tesla (3) Epcos
S/F in replacement of running capacitor 30/36 mfd for split type AC unit as required at Site and as directed by Engineer-in-Charge. Make- (1) Tibcon (2) Tesla (3) Epcos
Taking out burnt condenser fan motor and rewinding of condenser fan motor of split type AC units of capacity 1.5/2 TR including replacement of worn out bush and bearing complete all as specified and directed Engineer-in-Charge.
Taking out burnt blower motor and rewinding of blower motor of split type AC units of capacity1.5/ 2 TR including replacement of worn out bush and bearing complete all as specified and directed Engineer-in-Charge.
Disconnecting and taking down burnt compressor of capacity 2TR from split type AC unit and Supply and Fix new reciprocating type compressor with charging of refrigerent (R410A,R32,R134A)after dehydration testing and vaccumming one as per existing model complete including testing all as specified and directed by Engr-in-Charge. Make :- Kirloskar/Takemshah
Disconnecting and taking down burnt compressor of capacity 2TR from split type AC unit and Supply and Fix new rotary type compressor with charging of refrigerent after dehydration testing and vaccumming one as per existing model complete including testing all as specified and directed by Engr-in-Charge. Make :- Kirloskar/Takemshah
Disconnecting and taking down burnt compressor of capacity 1.5 TR with CFC free Refrigerent (R410a,R32) from split type AC unit and Supply and Fix new rotary/reciprocating type compressor with charging of refrigerent after dehydration testing and vaccumming one as per existing model complete including testing all as specified and directed by Engr-in-Charge.
M&L for repair to gas leakage of split type AC unit of capacity 1.5/2TR capacity including pressure testing, dehydration and gas charging complete all as specified and directed by Engr-in-Charge.
M&L for replacement of electronic remote control unit of split type A/C unit (cordless type) 1.5 Ton complete of existing make all as specified and directed by Engr-in-Charge.
M&L for replacement of electronic remote control unit of split type A/C unit (cordless type) 2.0 Ton complete of existing make all as specified and directed by Engr-in-Charge.
Taking out unserviceable PCB from 1.5 /2 TR split type A/C unit and refixing the serviceable PCB after repair from workshop complete testing all as specified & directed by Engineer-in-charge.
Taking out unserviceable PCB from 1.5 /2 TR inverter split type A/C unit and refixing the serviceable PCB after repair from workshop complete testing all as specified & directed by Engineer-in-charge.
M&L for replacement of unserviceable inverter type PCB from the existing inverter split type A/C unit 1.5/2.0 Ton complete of existing make ,testing all as specified and directed by Engr-in-Charge.
M&L for taking out unserviceable blower motor from split type A/C of capacity 1.5 /2 Ton unit complete and supply and fix new blower motor of the existing make complete all as specified and directed by Engineer-in-Chargee. Make:LG/Sidwal/Voltas
Material and Labour for providing insulation 9mm thick for dia 1/4",3/8",1/2",5/8",6/8" copper tubing’s from Indoor to outdoor units with foam insulation followed with clamps complete all as specified and directed by Engr-in-Charge.
Supply and charging Refrigerant(R410,R32,R134 and existing refrigerent) to any type of AC unit including CFC free and non CFC Free AC complete all as specified and directed by Engr-in-Charge.
M&L in replacement of copper tubing 10mm outer dia suitable for AC 2TR capacity complete all as specified and directed by Engr-in-Charge
M&L in replacement copper tubing 15mm outer dia complete all as specified and directed by Engr-in-Charge.
Repair & maintenance of water coolers of capacity 40/80/150 Ltrs comprising of the following tasks at different location complete all as specified and directed by Engineer-in-Charge. (a) Inspection, taking down, opening, dismantling, decaling, brushing cleaning of storage tanks (b) Examination water tightness, leak proof of storage tank after cleaning.(c) Carry out operation of all stop cock, push cock, float valve etc. (d) Inspect overflow and remove blockage if any. (e) Check and correct earth continuity of electric items (f) Check thermostat and test its functioning (g) Inspect drain pipe and remove blockage if any (h) Check and correct all electrical wiring & test its functioning (i) Testing of water cooler after repair
Supply & fixing in replacement of thermostat switch suitable for water cooler 40/80 as required at site complete all as specified and directed by Engr-in-Charge.
Supply and Fixing in replacement fan motor capacitor 2.5/3.15mfd. complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of starting relay as required at site for water coolers 40/80 Ltrs capacity complete including connecting, testing complete all as specified and directed by Engr-in-Charge.
Disconnecting & taking out compressor ('R type) from water cooler for any capacity and supply and fix the new compressor including flushing dehydration and gas charging complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair PVC insulated Sheathed, Copper conductor,6 sq mm ,3 core (flexible) cable,1100 Volts,complete all as specified and directed by Engineer-in-Charge.Make :-Plaza/Finolex/Polycab
Supply and fixing in repair PVC insulated Sheathed, Copper conductor,4 sq mm ,3 core (flexible) cable,1100 Volts,complete all as specified and directed by Engineer-in-Charge.Make :-Plaza/Finolex/Polycab
Taking down desert cooler of any size by disconnecting electrical supply, cleaning, oiling of all moving part of pump & exhaust fan/kit, Replacing PVC pipes, nozzles, distributors, pads, checking electrical connections complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of wood pads(set of three)as per sample complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement the new desert cooler pump. including testing for proper functioning complete all as specified and directed by Engr-in-Charge. Make-(1) Elpar (2) Khaitan (3) CG
Supply and fix new exhaust fan kit of desert cooler with super enameled copper wire complete all as specified and directed by Engineer-in-charge.
Repair and Maintenance of window type AC's of capacity 1.5 TR comprising of the following tasks at different locations including Refixing, commissioning and testing complete all as specified and directed by Engineer-in-Charge.(a) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil. (b) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts. (c) Inspecting the leakage in the system. d) Checking of the earth continuity of electrical parts. e) Checking the functioning of thermostat. f) Inspection of all electrical parts. g) Testing the machine for satisfactory operation.
S&F in replacement 'R' type compressor for Window type AC,1.5 TR as per existing make and including taking out old unserviceable one,flushing, dehydration and gas changing complete all as specified and directed by Engr-in-Charge.
S&F in replacement of copper condensor coil of window type AC 1.5 TR including after taking out old unserviceable coil and including dehydration ,charging complete all as specified and directed by Engr-in-Charge.
Repair & maintenance of Refrigerator of any capacity comprising of the following tasks at different location complete all as specified and directed by Engineer-in-Charge. a) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil. b) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts. c) Inspecting the leakage in the system. d) Checking of the earth continuity of electrical parts. (e) Checking the functioning of thermostat. f) Inspection of all electrical parts. g) Testing the machine for satisfactory operation. (h) Check and correct all electrical wiring & test its functioning (j) Testing of Refrigerator after repair.
Repair & maintenance of voltage stabilizer of capacity 5 KVA comprising of the following tasks at different location complete all as specified and directed by Engr-in-Charge. (a) Rewinding of Transformer copper coil with new copper wire as per existing gauge (b) Time delay relay-01 No. c) Cut out relay-01 No. (d) printed citcuit relay- 01 No.
Dismantling of Split type AC 1.5/2.0 TR capacity from position after including disconnecting all connections between indoor and out door units,shifting, backup refrigerant for reuse and install at a place where directed carefully,including cutting on wall,making hole and make good disturbed surface properly matching surface,inspecting,servicing and refilling refrigerant and testing complete all as directed by Engr-in-Charge.
M & L for the nitrogen pressure testing after installation of condenser coil of 5.5 TR split AC and complete pressure testing for the no leakage confirmation complete all as specified and directed by Engr-in-Charge.
M&L for gas leakgae detection including dehydration of complete 5.5 TR split AC and vaccuming the system with vaccume pump and recharging the suitable refrigerent complete all as specified and directed by Engr-in-Charge.
M&L in replacement of copper tubing 10mm outer dia suitable for 5.5 TR split AC capacity complete all as specified and directed by Engr-in-Charge.
Taking out the unserviceable condensor motor of 5.5 ton AC and S&F the new condenser motor of 5.5 TR split AC of existing make complete all as specified and as directed by Engineer-in-Charge
Disconnecting and taking down burnt compressor of capacity 5.5 TR from ductable split type unit and Supply and Fix new compressor of exsiting make with charging of refrigerent after dehydration testing and vaccumming one as per existing model complete including testing all as specified and directed by Engr-in-Charge.
Taking out unserviceable indoor unit and supply and fix the new indoor unit of 2 TR capacity split AC 230 Volts single phase including installing ,charging complete all as specified and directed by Engr-in-Charge. .Make : Hitachi/Blue star/LG
Supply and fix in repair single pole and netural enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20-32 amps complete all as specified and directed by Engr-in-Charge. .Make :- L&T/Havells/Indoasian
Supply and fix in repair outdoor unit fan blade for 5.5 TR split AC complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair outdoor unit fan blade for 2.0/1.5 TR split AC complete all as specified and directed by Engr-in-Charge.
Disconnecting and taking down burnt compressor of capacity 1.5TR from split type AC unit and Supply and Fix new inverter type compressor with charging of refrigerent (R410A,R32,R134A)after dehydration testing and vaccumming one as per existing model complete including testing all as specified and directed by Engr-in-Charge.
Disconnecting and taking down burnt compressor of capacity 2TR from split type AC unit and Supply and Fix new inverter type compressor with charging of refrigerent (R410A,R32,R134A)after dehydration testing and vaccumming one as per existing model complete including testing all as specified and directed by Engr-in-Charge.
Repair & maintenance of Deep Freezer 300 Ltrs capacity comprising of the following tasks at different location complete all as specified and directed by Engineer-in-Charge. a) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil. b) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts. c) Inspecting the leakage in the system. d) Checking of the earth continuity of electrical parts. (e) Checking the functioning of thermostat. f) Inspection of all electrical parts. g) Testing the machine for satisfactory operation. (h) Check and correct all electrical wiring & test its functioning .
J.P. Enterprises
Singh Associates
Akhil Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .